• Title/Summary/Keyword: Plasma-Solution System

Search Result 122, Processing Time 0.03 seconds

General Pharmacology of Recombinant Erythropoietin (LB-00014) (유전자 재조합 Erythropoietin (LB-00014)의 일반약리작용)

  • 이은방;이향주;천선아;조성익;손지영
    • Biomolecules & Therapeutics
    • /
    • v.4 no.2
    • /
    • pp.154-161
    • /
    • 1996
  • General pharmacological properties of LB-00014, an erythropoietin which was produced by recombinant DNA technique in Biotech Research Institute, LG Chemical Ltd. were examined. The administration of LB-00014 (60, 600, 6000 IU/kg, iv) in mice had no effect in general behavior and central nervous system, and no influences on normal body temperature, writhing syndromes induced by 0.7% acetic acid solution and chemoshock produced by strychnine and pentetrazole solution. LB-00014 (60, 600, 6000 IU/kg, iv) given to anesthetized rabbits showed no effect on blood pressure of carotid artery and respiration rates, and it did not influence the responses produced by injection of acetylcholine or epinephme. The administration of LB-00014 (601, 600, 6000 IU/kg, iv) in rats had no effect on the plasma prothrombin time, activated partial thromboplastin time and hemolytic action. The platelet aggregation induced by collagen in human plasma was not influenced by LB-00014 (10, 100, 1000 lU/kg, iv). It showed no direct effect at 100 and 1000IU/m1 in isolated stomach fundus and uterus of rats and ileum of guinea-pig, and it also had no inhibition of contraction produced by acetylcholine, oxytocin, serotonin and histamine in the above-mentioned preparations. It did not influence gastric secretion, pH and acid output at 6000 IU/kg, iv in rats, but showed a significant increase in intestinal propulsion of mice at 6000 IU/kg, iv. Its administration (60, 600, 6000 lU/kg, iv) caused no effect on urine and electrolyte excretion in rats. These results indicate that LB-00014 does not exsert any of serious pharmacological effects.

  • PDF

An Intravenous Replenishment of Salivary Components and Dry Forage Intake in Freely Drinking Large-type Goats

  • Sunagawa, K.;Hashimoto, T.;Izuno, M.;Hashizume, N.;Okano, M.;Nagamine, I.;Hirata, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.4
    • /
    • pp.538-546
    • /
    • 2008
  • Large-type goats eating dry forage secreted large volumes of saliva which resulted in the loss of $NaHCO_3$ from the blood and decreased plasma volume (hypovolemia). This research investigated whether or not the loss of $NaHCO_3$ from the blood and hypovolemia brought about by dry forage feeding actually depresses feed intake in large-type goats under free drinking conditions. The present experiment consisted of three treatments (NI, ASI, MI). All treatments in this experiment were carried out under free drinking conditions. In the NI control (NI), a solution was not infused. In the ASI treatment, i.v. infusion of artificial saliva was initiated 2 h before feeding and was continued for a total of 3 h concluding 1 h after the commencement of the feeding perod. In the MI treatment, mannitol solution was infused to replenish only water lost from the blood in the form of saliva. The hematocrit and plasma total protein concentrations during feeding in the NI control were observed to be higher than pre-feeding levels. This indicated that dry forage feeding-induced hypovolemia was caused by the accelerated secretion of saliva during the initial stages of feeding in freely drinking large-type goats. Increases in hematocrit and plasma total protein concentrations due to dry forage feeding were significantly suppressed by the ASI treatment. While hematocrit during feeding in the MI treatment was significantly lower than the NI control, plasma total protein concentrations were not different. From these results, it is clear that the MI treatment was less effective than the ASI treatment in mitigating the decreases in plasma volume brought about by dry forage feeding. This indicates that plasma volume increased during dry forage feeding in the ASI treatment which inhibited production of angiotensin II in the blood. The ASI treatment lessened the levels of suppression on dry forage feeding, but the MI treatment had no effect on it under free drinking conditions. The results indicate that despite the free drinking conditions, increases in saliva secretion during the initial stages of dry forage feeding in large-type goats caused $NaHCO_3$ to be lost from the blood into the rumen which in turn caused a decrease in circulating plasma volume and resulted in activation of the renin-angiotensin system and thus feeding was suppressed.

Response Characteristics of the Scattered Signal of a Microwave Reflectometry (마이크로파 Reflectometry의 산란 신호 응답 특성)

  • Baang, Sung-Keun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.5
    • /
    • pp.556-561
    • /
    • 2008
  • The characteristics of microwave reflectometry, which is based on the technologies of FM radar and is applied as a non-invasive method to examine the properties including density distribution of inhomogeneous media, is investigated. The microwave reflectometry system requires not only an optimized system hardware but as well as the understanding of system response from the media under test in order to provide the system solution describing the object under test quantitatively. The introduction of microwave reflectometry especially in the area of applied plasma physics has been relatively new and the number of usage is found to be increasing gradually. The experimental method to characterize the microwave system as a device to examine the properties of plasma is explained. The microwave reflectometry signals consist of the cutoff signals which originate from the region where most of the reflected power comes from and the scattered signals which result as an interaction of the microwave and the density perturbations. This paper describes the experimental results of the scattered signal from the microwave reflectometry, such as the wavenumber dependence and the sensitivity on density perturbation, and the comparison of the characteristics with those from the numerical simulations and those from the cutoff signals.

Representation of fundamental solution and vibration of waves in photothermoelastic under MGTE model

  • Rajneesh Kumar;Nidhi Sharma;Supriya Chopra;Anil K. Vashishth
    • Ocean Systems Engineering
    • /
    • v.13 no.2
    • /
    • pp.123-146
    • /
    • 2023
  • In this paper, Moore-Gibson-Thompson theory of thermoelasticity is considered to investigate the fundamental solution and vibration of plane wave in an isotropic photothermoelastic solid. The governing equations are made dimensionless for further investigation. The dimensionless equations are expressed in terms of elementary functions by assuming time harmonic variation of the field variables (displacement, temperature distribution and carrier density distribution). Fundamental solutions are constructed for the system of equations for steady oscillation. Also some preliminary properties of the solution are explored. In the second part, the vibration of plane waves are examined by expressing the governing equation for two dimensional case. It is found that for the non-trivial solution of the equation yield that there exist three longitudinal waves which advance with the distinct speed, and one transverse wave which is free from thermal and carrier density response. The impact of various models (i)Moore-Gibson-Thomson thermoelastic (MGTE)(2019), (ii) Lord and Shulman's (LS)(1967) , (iii) Green and Naghdi type-II(GN-II)(1993) and (iv) Green and Naghdi type-III(GN-III)(1992) on the attributes of waves i.e., phase velocity, attenuation coefficient, specific loss and penetration depth are elaborated by plotting various figures of physical quantities. Various particular cases of interest are also deduced from the present investigations. The results obtained can be used to delineate various semiconductor elements during the coupled thermal, plasma and elastic wave and also find the application in the material and engineering sciences.

Optimization of Reverse Engineering Processes for Cu Interconnected Devices

  • Koh, Jin Won;Yang, Jun Mo;Lee, Hyung Gyoo;Park, Keun Hyung
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.6
    • /
    • pp.304-307
    • /
    • 2013
  • Reverse engineering of semiconductor devices utilizes delayering processes, in order to identify how the interconnection lines are stacked over transistor gates. Cu metal has been used in recent fabrication technologies, and de-processes becomes more difficult with the shrinking device dimensions. In this article, reverse engineering technologies to reveal the Cu interconnection lines and Cu via-plugs embedded in dielectric layers are investigated. Stacked dielectric layers are removed by $CF_4$ plasma etching, then the exposed planar Cu metal lines and via-plugs are selectively delineated by wet chemical solution, instead of the commonly used plasma-based dry etch. As a result, we have been successful in extracting the layouts of multiple layers within a system IC, and this technique can be applicable to other logic IC, analog IC, and CMOS IC, etc.

Study of PSII-treated PMMA, PHEMA, and PHPMA ; Investigation of Their Surface Stabilities

  • Hyuneui Lim;Lee, Yeonhee;Seunghee Han;Jeonghee Cho;Moojin suh;Kem, Kang-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.204-204
    • /
    • 1999
  • The plasma source ion implantation(PSII) technique which is a method using high negative voltage pulse in plasma system has the potential to change the surface properties of polymer. PSII technique increase the surface free energy by introducing polar functional groups on the surface so that it improves reactivity, hydrophilicity, adhension, biocompatability, etc. However, the mobility of polymer chains enables the modified surface layers to adapt their composition to interfacial force. This hydrophobic recovery interrupts the stability of modified surfaces to keep for the long time. In this study, poly(methyl methacrylate)(PMMA), poly(2-hydroxyethyl methacrylate)(PHEMA), and polu(2-hydroxypropyl methacylate)(PHPMA) for contact lens application, were modified to improve the wettability with PSII technique and were investigated the surface stabilities. Polymer film was prepared with solution casting(3 wt.% solution) and was annealed at 11$0^{\circ}C$ under vacuum oven to remove solvent completely and to eliminate physical ageing. The thickness of the film measured by scanning electron microscopy (SEM) and surface profilometer was about 10${\mu}{\textrm}{m}$. Polymers were treated with different kinds of gases, pulse frequency, pulse with, pulse voltage, and treatment time. Even though PMMA, PHEMA, and PHPMA have similar repeat unit structure, the optimal treatment conditions and the tendency to hydrophobic recovery were different. PHPMA, more hydrophilic polymer than PMMA and PHEMA showd better wettability and stability after mild treatment. Surface tensions were obtained by water and diiodomethane contact angle measurements to monitor the relation between hydrophobic recovery and polymer structure. Different ion species in plasma change the polar component and dispersion component of polymer surface. For better wettability surface, the increase of polar component was a dominant factor. We also characterized modified polymer surfaces using x-ray photoelectron spectroscopy(XPS), secondary ion mass spectrometry(SIMS), Fourier Transform infrared spectroscopy(FT-IR), and SEM.

  • PDF

Characteristic Feature of Inductively Coupled Plasma Atomic Emission Spectrometer/Shielding System and Evaluation of Its Applicability to Analysis of Radioactive Materials (유도 결합 플라스마 원자방출분광기/차폐 시스템의 특성 및 방사성 물질 분석에 대한 적용성 평가)

  • Lee, Chang Heon;Suh, Moo Yul;Choi, Kae Chun;Park, Yang Soon;Jee, Kwang Yong;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.474-483
    • /
    • 2000
  • An inductively coupled plasma atomic emission spectrometer/shielding system was specially designed and built for the analysis of radioactive materials. Both of an inductively coupled plasma source and a sample transfer system to be contacted with radioactive materials was installed in a stainless steel glove box. In terms of analytical capability and radiation safety, characteristic feature of the system was investigated. Its applicability to the determination of fission products and corrosion products in the radioactive materials such as spent fuel dissolver solution and the primary coolant of nuclear power reactors was evaluated. In the concentration range $0.01-0.1mgL^{-1}$, the relative standard deviation was found to be less than 5%.

  • PDF

Microstructure Characterization of Nb-Si-B alloys Prepared by Spark Plasma Sintering Process (방전 플라즈마 소결(Spark Plasma Sintering) 방법에 의해 제조된 Nb-Si-B계 합금의 미세조직 특성)

  • Kim, Sang-Hwan;Kim, Nam-Woo;Jeong, Young-Keun;Oh, Sung-Tag;Kim, Young Do;Lee, Seong;Suk, Myung Jin
    • Journal of Powder Materials
    • /
    • v.22 no.6
    • /
    • pp.426-431
    • /
    • 2015
  • Microstructural examination of the Nb-Si-B alloys at Nb-rich compositions is performed. The Nb-rich corner of the Nb-Si-B system is favorable in that the constituent phases are Nb (ductile and tough phase with high melting temperature) and $T_2$ phase (very hard intermetallic compound with favorable oxidation resistance) which are good combination for high temperature structural materials. The samples containing compositions near Nb-rich corner of the Nb-Si-B ternary system are prepared by spark plasma sintering (SPS) process using $T_2$ and Nb powders. $T_2$ bulk phase is made in arc furnace by melting the Nb slug and the Si-B powder compact. The $T_2$ bulk phase was subsequently ball-milled to powders. SPS is performed at $1300^{\circ}C$ and $1400^{\circ}C$, depending on the composition, under 30 MPa for 600s, to produce disc-shaped specimen with 15 mm in diameter and 3 mm high. Hardness tests (Rockwell A-scale and micro Vickers) are carried out to estimate the mechanical property.

Atmospheric Pressure Plasma를 이용한 Oxide Thin Film Transistor의 특성 개선 연구

  • Mun, Mu-Gyeom;Kim, Ga-Yeong;Yeom, Geun-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.582-582
    • /
    • 2013
  • Oxide TFT (thin film transistor) active channel layer에 대한 저온 열처리 공정은 투명하고 flexibility을 기반으로하는 display 산업과 AMOLED (active matrix organic light emitting diode) 분야 등 다양한 분야에서 필요로 하는 기술로서 많은 연구가 이루어지고 있다. 과거 active layer는 ALD (atomic layer deposition), CVD (chemical vapor deposition), pulse laser deposition, radio frequency-dc (RF-dc) magnetron sputtering 등과 같은 고가의 진공 장비를 이용하여 증착 되어져 왔으나 현재에는 진공 장비 없이 spin-coating 후 열처리 하는 저가의 공정이 주로 연구되어 지고 있다. Flexible 기판들은 일반적인 OTFT (oxide thin films Transistor)에 적용되는 열처리 온도로 공정 진행시 열에 의한 기판의 손상이 발생한다. Flexible substrate의 열에 의한 기판 손상을 막기 위해 저온 열처리 공정이 연구되고 있지만 기존 열처리와 비교하여 소자의 특성 저하가 동반 되었다. 본 연구에서는 Si 기판위에 SiO2 (100)를 절연층으로 증착하고 그 위에 IZO (indium zinc oxide) solution을 spin-coating 한뒤 $250^{\circ}C$ 이하의 온도에서 열처리하였다. 저온 공정으로 인하여 소자의 특성 저하가 동반 되었으므로 소자의 저하된 특성 복원하고자 post-treatment로 고가의 진공장비가 필요 없고 roll-to roll system 적용이 수월한 remote-type의 APP (atmospheric pressure plasma) 처리를 하였다. Post-treatment로 APP를 이용하여 $250^{\circ}C$ 이하에서 소자에 적용 가능한 on/off ratio를 얻을 수 있었다.

  • PDF

The removal characteristics of No, SOx for plasma reactor separated flue gas duct from discharge domain (연소가스관로와 방전영역 분리형 플라즈마 반응기에서 Nox, SOx 제거특성)

  • Park, J.Y.;Koh, Y.S.;Lee, J.D.;Song, W.S.;Park, S.H.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2007-2009
    • /
    • 1999
  • In this paper, discharge domain of wire-cylindrical plasma reactor was separated from a gas flow duct to avoid unstable discharge by aerosol particle deposited on discharge electrode and grounded electrode. The NOx, SOx removal was experimentally investigated by a reaction induced to ammonium nitrate, ammonium sulfate using a low price of aqueous NaOH solution and a small quantity of ammonia. Volume percentage of aqueous NaOH solution used was 20% and $N_2$ flow rate was 2.5[$\ell$/min] for bubbling aqueous NaOH solution. Ammonia gas(14.82%) balanced by argon was diluted by air and was introduced to a main simulated flue gas duct through $NH_3$ injection system which was in downstream of reactor. The $NH_3$ molecular ratio[MR] was determined based on $NH_3$ to [NO+$SO_2$]. MR is 1.5. The NOx removal rates increased in the order of DC, AC and pulse, but SOx removal rates was not significantly effected by source of electricity. The NOx removal rate slightly decreased with increasing initial concentration but SOx removal rate was not significantly effect by initial concentration, and NOx, SOx removal rates decreased with increasing gas flow rate.

  • PDF