• Title/Summary/Keyword: Plasma Diagnosis

Search Result 340, Processing Time 0.032 seconds

Establishment for Improving Productivity of Cattle by Fecal Steroid and Milk Urea Nitrogen analysis - II. Application of Early Pregnancy Diagnosis and Monitoring Postpartum Ovarian Activity

  • Kang, Chung-Boo;Ha, Woo-Song;Kwon, Ji-In;Yu, Young-Sang;Kim, Chul-Ho;Kwak, Soo-Dong
    • Biomedical Science Letters
    • /
    • v.9 no.1
    • /
    • pp.29-36
    • /
    • 2003
  • Progesterone levels in the blood plasma or skim milk of cows are considered to be very useful indicator fur the detection of estrus cycle and early pregnancy diagnosis. During 13 to 14 days after estrus the level of progesterone in plasma or skim milk were not different between the inseminated arid non-inseminated cows. In the pregnant cows the peak level of progesterone reached on 14th day after artificial insemination (AI), but in the absence of conceptus the level declines after the 14th day slowly, and then very rapidly towards the basal level after the 17th day. This low level persists about 4 days, including those of estrus and ovulation a highly characteristic pattern which differs so markedly from that in the pregnant cows. Progesterone levels in blood plasma or skim milk can provided a reliable diagnosis of early pregnancy and monitoring ovarian activity in cows. The mean $\pm$ standard deviation of milk urea nitrogen(MUN) and protein concentration in the cows at 9 herds were 17.7$\pm$2.35 mg/dL and 3.2$\pm$0.17%, respectively. The days of nonpregnant after parturition was shorter in the cows in which the lower level of MUN than higher level of MUN concentration.

  • PDF

Diagnosis Value of Membrane Glycolipids Biochemistry Index in Intracranial and Gastrointestinal Tumors

  • Lv, Jun;Lv, Can-Qun;Mei, Ping;Qi, Shi-Mei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.7
    • /
    • pp.2693-2696
    • /
    • 2015
  • The diagnostic value of membrane glycolipid biochemistry index, the lipid-bound sialic acid (LSA) and total sialic acid (TSA) in cerebrospinal fluid (CSF) was evaluated in 30 intracranial and 65 gastrointestinal tumors. The plasma LSA, TSA and red cell membrane sialic acid (R-SA) in were determined according to the method of Sevenmerhulm. Our results showed that the levels of LSA and TSA in CSF of intracranial tumor patients was higher than that of normal group(p<0.01). The concentration of TSA and LSA in patients with malignant glioma was higher than that of benign meningioma patients(P<0.01). No significance was found between intracranial halmatoma patients and normal control group for levels of membrane glycolipids (p>0.05). Results also found that the plasma LSA, TSA and R-SA of gastric carcinoma were significantly higher than those of control group (p<0.05); while no significant difference was found in the plasma LSA, TSA and R-SA levels between chronic gastritis, gastrohelcoma and normal control group (p>0.05). Plasma LSA, TSA and R-SA levels of gastric carcinoma patient were significantly higher than those of chronic gastritis patients and gastrohelcoma patients(p<0.05). It was also found that plasma LSA, TSA and R-SA contents were significantly higher in large intestine carcinoma patients than in benign in stestine tumor patients (p<0.05) while no significant difference was found between intestine benign tumor and normal control group (p>0.05). The levels of LSA, TSA and R-SA were obviously higher in the patients with metastasis than in the ones without (p<0.05.) The membrane glycolipid biochemistry index LSA and TSA in CSF are sensive markers for diagnosing intracranial tumors. For gastrointestinal malignant tumors the plasma LSA TSA and red blood cell membrane SA may be considered as auxiliary indicators for diagnosis. They can be used for distinguishing benign from malignant tumors.

A study on the early pregnancy diagnosis by changing of plasma progesterone concentration and morphology of ovary in pregnancy and non -pregnancy cows (소에서 비임신 및 임신 상태의 난소 형태와 혈중 progesterone 농도 변화에 의한 조기 임신진단)

  • Kim, Cheol-Ho;Bhak, Jong-Sik;Shin, Jung-Sub;Kang, Chung-Bo
    • Korean Journal of Veterinary Service
    • /
    • v.31 no.3
    • /
    • pp.397-414
    • /
    • 2008
  • In order to evaluate conception rate of Hanwoo in northwestern region of Gyeongsang-nam-do, we investigated conception rate and reduction of reproductive disorder rate after artificial insemination (AI) in 1,000 heads of breeding cows, This study showed that 80.9% of cows were classified as fertility after 1st and 2nd AI. For a accurate pregnancy diagnosis with practicing ovariectomy and histeotomy, we comparatively investigated each of 80 slaughtered cows, including 30 of non-pregnancy, and used enzyme-linked immunosorbent assay (ELISA) for estimation of plasma progesterone concentration and serum luteal hormone. The mean diameter of non-pregnant corpus luteum is $18.9{\pm}4.2{\times}15.6{\pm}3.6 mm$ and that of pregnant corpus luteum is $22.5{\pm}2.7{\times}18.7{\pm}2.9 mm$. This indicates that corpus luteum is more developed in the ovary of pregnant than non-pregnant cows (P<0.05). The diameter of pregnant corpus luteum according to the stage of pregnancy showed $21.3{\pm}2.4{\pm}18.4{\pm}2.6 mm$ in early stage (1-3 month), $23.4{\pm}2.8{\times}19.1{\pm}2.7 mm$ in middle stage (4-6 month) and $22.8{\pm}3.0{\times}18.8{\pm}2.4mm$, in last stage (7-9 month). This indicates that corpus luteum in middle and last stage is more significantly developed than that of early stage(P<0.05). The mean plasma progesterone concentration of cows showing size of non-pregnant corpus luteum was $4.58{\pm}0.92ng/ml$ and that of pregnant corpus luteum $8.26{\pm}0.98ng/ml$. Thus, it was more significantly increased in pregnant corpus luteum(P<0.02).. However, it was low to $0.58{\pm}0.39ng/ml$. in estrus (corpus albicans). The plasma progesterone concentration according to gestation period was high in proportion to the degree of development in corpus luteum and more significantly increased (P<0.05) and maintained in middle and last state than early state. The concentration was sharply decreased to $0.56{\pm}0.32ng/ml$ at parturition. As a consequence, we can practice the early pregnancy diagnosis by confirming non-pregnancy when the mean plasma progesterone concentration is below 1ng/ml 19 to 22 days after AI and this can be available to diagnose reproductive disorder.

Fabrication and Simulation of Fluid Wing Structure for Microfluidic Blood Plasma Separation

  • Choe, Jeongun;Park, Jiyun;Lee, Jihye;Yeo, Jong-Souk
    • Applied Science and Convergence Technology
    • /
    • v.24 no.5
    • /
    • pp.196-202
    • /
    • 2015
  • Human blood consists of 55% of plasma and 45% of blood cells such as white blood cell (WBC) and red blood cell (RBC). In plasma, there are many kinds of promising biomarkers, which can be used for the diagnosis of various diseases and biological analysis. For diagnostic tools such as a lab-on-a-chip (LOC), blood plasma separation is a fundamental step for accomplishing a high performance in the detection of a disease. Highly efficient separators can increase the sensitivity and selectivity of biosensors and reduce diagnostic time. In order to achieve a higher yield in blood plasma separation, we propose a novel fluid wing structure that is optimized by COMSOL simulations by varying the fluidic channel width and the angle of the bifurcation. The fluid wing structure is inspired by the inertial particle separator system in helicopters where sand particles are prevented from following the air flow to an engine. The structure is ameliorated in order to satisfy biological and fluidic requirements at the micro scale to achieve high plasma yield and separation efficiency. In this study, we fabricated the fluid wing structure for the efficient microfluidic blood plasma separation. The high plasma yield of 67% is achieved with a channel width of $20{\mu}m$ in the fabricated fluidic chip and the result was not affected by the angle of the bifurcation.

Evaluation of Plasma Characteristics for Hg-Ar Using LIF (LIF를 이용한 Hg-Ar 플라즈마 특성 평가)

  • Moon, Jong-Dae
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.79-83
    • /
    • 2008
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. Due to this generation, the extinction of atoms in a metastable state occurred through collision, ionization, and excitation between plasma particles. The density and distribution of the metastable state depended on the energy and density of plasma particles, intensely. This highlights the importance of measuring density distribution in plasma electric discharge mechanism study. The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength. change, and also confirmed that the largest fluorescent signal in 436nm, and that the density of atoms in 546.2nm ($6^3S_1{\to}6^3P_2$) were larger than 404.8nm ($6^3S_1{\to}6^3P_2$). According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the LIF signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

Non-Invasive Plasma Monitoring Tools and Multivariate Analysis Techniques for Sensitivity Improvement

  • Jang, Haegyu;Lee, Hak-Seung;Lee, Honyoung;Chae, Heeyeop
    • Applied Science and Convergence Technology
    • /
    • v.23 no.6
    • /
    • pp.328-339
    • /
    • 2014
  • In this article, plasma monitoring tools and mulivariate analysis techniques were reviewed. Optical emission spectroscopy was reviewed for a chemical composition analysis tool and RF V-I probe for a physical analysis tool for plasma monitoring. Multivariate analysis techniques are discussed to the sensitivity improvement. Principal component analysis (PCA) is one of the widely adopted multivariate analysis techniques and its application to end-point detection of plasma etching process is discussed.

Comparison of Li-heparinized Versus Na-fluorinated Plasma for Routine Blood Glucose Determination Using Hexokinase Procedure (Hexokinase 방법을 이용한 Heparin 혈장과 NaF 혈장 시료의 혈당 분석치 비교)

  • Moon, In-Kyung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.1
    • /
    • pp.25-30
    • /
    • 2007
  • In this study, the two sampling methods for blood glucose measurement were evaluated in order to reduce pre-analytical error. For this purpose, glucose levels of Li-heparinized plasma (LHP) and Na-fluorinated plasma (NFP) in blood collected from healthy volunteers were determined by using routine hexokinase procedures. The percentage range of pre-analytical error was quantitated by comparing LHP glucose values with NFP glucose values according to delaying analytical time (0, 60, and 120 min). LHP glucose values were decreased by 6.6% in 60 min., 17.7% in 120 min, whereas NFP glucose values decreased by 1.1% in 60 min, 2.0% in 120 min. Therefore it may be recommended that the NFP sampling method should be used for routine blood glucose determination in diabetes mellitus diagnosis.

  • PDF

Nerve Growth Factor and Sensory Neuropeptide Levels in Plasma and Saliva of Various Orofacial Pain Patients (다양한 구강안면통증환자의 혈장 및 타액에서의 신경성장인자와 감각성 신경펩티드 농도에 관한 연구)

  • Jang, Min-Uk;Chung, Sung-Chang;Chung, Jin-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.4
    • /
    • pp.387-395
    • /
    • 2009
  • Nerve growth factor (NGF) and sensory neuropeptides are involved in the process of nociception at peripheral nerve fibers and wide spread in central nervous system. The aims of this study were to investigate NGF and sensory neuropeptides (substance P [SP] and calcitonin gene-related peptide [CGRP]) levels in human plasma and saliva, and the associations between these sensory neuropeptides levels and chronic orofacial pain symptoms. NGF, SP, and CGRP levels in plasma and resting whole saliva samples collected from 67 orofacial pain patients (joint pain, dental or periodontal pain, mucosal pain) and 36 pain free control subjects were measured by enzyme immunoassay. The characteristic pain intensity of each subject was measured using the Graded Chronic Pain Scale and the flow rate of resting whole saliva was measured. Joint pain patients group showed significantly higher plasma NGF level compared to each of dental pain patients (p<0.01), mucosal pain patients (p<0.01), and control group (p<0.01). Plasma NGF level of dental pain patients group was significantly higher than that of control group (p<0.01). Saliva SP level of dental pain patients group (p<0.05) and saliva CGRP level of mucosal pain group (p<0.05) were significantly higher than that of control group. Plasma and saliva SP levels of joint pain patients was significantly associated with pain intensity (plasma: standardized coefficient=0.599, p<0.01, saliva: standardized coefficient=0.504, p=0.05). In dental pain patients group, plasma SP (standardized coefficient=0.559, p<0.01), saliva SP (standardized coefficient=0.520, p<0.01) and saliva CGRP (standardized coefficient=0.599, p<0.01) levels were significantly associated with age. In mucosal pain patients group, plasma SP (standardized coefficient=0.495, p<0.05), saliva SP (standardized coefficient=0.500, p<0.05), and saliva CGRP (standardized coefficient=0.717, p<0.01) levels were significantly associated with age. NGF and neuropeptides may play a role in the maintenance of various orofacial pain symptoms. The examination of those levels in plasma and saliva helps understanding the mechanism of orofacial pain, and furthermore, can be applied to the diagnosis and therapy of orofacial pain.

Optical In-Situ Plasma Process Monitoring Technique for Detection of Abnormal Plasma Discharge

  • Hong, Sang Jeen;Ahn, Jong Hwan;Park, Won Taek;May, Gary S.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.2
    • /
    • pp.71-77
    • /
    • 2013
  • Advanced semiconductor manufacturing technology requires methods to maximize tool efficiency and improve product quality by reducing process variability. Real-time plasma process monitoring and diagnosis have become crucial for fault detection and classification (FDC) and advanced process control (APC). Additional sensors may increase the accuracy of detection of process anomalies, and optical monitoring methods are non-invasive. In this paper, we propose the use of a chromatic data acquisition system for real-time in-situ plasma process monitoring called the Plasma Eyes Chromatic System (PECS). The proposed system was initially tested in a six-inch research tool, and it was then further evaluated for its potential to detect process anomalies in an eight-inch production tool for etching blanket oxide films. Chromatic representation of the PECS output shows a clear correlation with small changes in process parameters, such as RF power, pressure, and gas flow. We also present how the PECS may be adapted as an in-situ plasma arc detector. The proposed system can provide useful indications of a faulty process in a timely and non-invasive manner for successful run-to-run (R2R) control and FDC.