• Title/Summary/Keyword: Plant operating state

Search Result 105, Processing Time 0.035 seconds

NUMERICAL ANALYSIS FOR FLOW CHARACTERISTICS WITH GEOMETRIC SHAPE AND CONTROL CONDITIONS IN SUBSEA BY-PASS VALVE (심해저 바이패스 밸브의 기하학적 형상과 제어조건에 따른 유동특성에 관한 수치해석적 연구)

  • Lee, J.H.;Min, C.H.;Oh, J.W.;Cho, S.;Kim, H.W.
    • Journal of computational fluids engineering
    • /
    • v.21 no.2
    • /
    • pp.99-105
    • /
    • 2016
  • The present study has been carried out to analyze the flow characteristics with geometric shape and control conditions in subsea by-pass valve. The function of by-pass valve is to prevent reverse flow. In this study, the static analysis has been perform for analyzing fluid flow in open state. In order to consider the turbulent effect, the standard ${\kappa}-{\varepsilon}$ model was used. A variety of parametric studies, such as by-pass valve type or size, volume flow rate, leakage hole size, leakage hole position, block type, block shape, were performed. The pressure difference across the valve in the model broadened the flow channel cross-sectional area was greater than the base model for the same operating conditions. As the pipe diameter in the block decreases the pressure difference is greatly increased. The pressure difference according to block shape such as edge type and round was almost negligible. For the same Reynolds number the pressure difference was little changed according to the size of the valve.

Plant Growth and Morphogenesis Control in Transplant Production System using Light-emitting Diodes(LEDs) as Artificial Light Source - Spectral Characteristics and Light Intensity of LEDs - (인공광원으로 발광다이오우드를 이용한 묘생산 시스템에서 식물생장 및 형태형성 제어 - 발광다이오우드의 분광 특성 및 광강도 -)

  • 김용현
    • Journal of Biosystems Engineering
    • /
    • v.24 no.2
    • /
    • pp.115-122
    • /
    • 1999
  • Because of their small mass, volume, solid state construction and long life, light-emitting diodes(LEDs) hold promises as a lighting source for intensive plant production system. Spectral characteristics and light intensity of LEDs were tested to investigate their feasibility as artificial lighting sources for growth and morphogenesis control in transplant production system. Blue, green, and red LEDs had a peak-emission wavelength at 442nm, 522nm, and 673nm, respectively. Their half width defined as the difference between upper and lower wavelength in the intensity equivalent to 50% of the maximum intensity showed 26nm, 41nm, and 74nm, respectively. Photosynthetic photon flux(PPE) at the distance of 9cm under the LEDs array was measured as $235{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ for red, $109{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ for green, and $75{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ for blue LEDs. At the same distance, green LEDs had the illuminance of 13,0001x, nine to ten times higher than those of red and blue LEDs. Red, green, and blue LEDs at a distance of 9cm had the irradiance of $46W{\cdot}m^{-2},\;19W{\cdot}m^{-2},\;8W{\cdot}m^{-2}$, respectively. Light intensity of blue, green, and red LEDs increased linearly in proportion to the magnitude of the current applied to the operating circuit. Thus the light intensity of LEDs was controlled by the applied current in operating circuit.

  • PDF

Advanced New Process Development of Two-Stage Swirl Calciner

  • Suh, Hyung-Suhk;Park, Choon-Keun;Ryu, Jae-Sang;Kwak, Hong-Bae
    • The Korean Journal of Ceramics
    • /
    • v.5 no.3
    • /
    • pp.296-302
    • /
    • 1999
  • The state of the art of the 2-stage swirl calciner is to make 2-stage counter gas flow in a calciner with cooler hot air. Gas flow in the calciner increases retention time of raw mix particles. Simple structure of the 2-stage swirl calciner operated optimally the rotary cement kiln. In this study, in order to decide the entrance type of the cooler air of the optimal calciner model, an entrance cooler air velocity, the input points of raw mix were analyzed in many aspects with cold model experiment and computational fluidized dynamic simulation. It was found that the entrance type of cooler air fully splite 2-stage for the optimal condition of the cold model calciner. The operation conditions were that the input feeding, the cooler air velocity and the air velocity of throat were 0.33kg/$\textrm m$3$, 15m/s and 20m/s respectively. The performance of 150 t/d the pilot plant connected with the kiln rising duct was that volume capacity of the calciner is over 430 kg/$\textrm m$3$-h, decarbonation rate of raw mix apparently 90%, heat consumption 950 kcal/kg-cli and retention time of raw mix 2.4 sec. Its the best operating condition is cooler air velocity 18m/s, the gas velocity of throat 25m/s, feeding rate of raw mix 10t/h. The operating experience of the pilot plant confirmed the success of scale up for over 3000 t-cli/d.

  • PDF

A Study on the Learning Curve and Productivity (한국 정유산업의 학습곡선과 생산성에 관한 연구)

  • 이종철;강규철
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.43
    • /
    • pp.175-195
    • /
    • 1997
  • The learning curve has an important effect the growth of corporation. But, in Korea, the study and inference on the learning rate of each industry are unprepared, and so, Korean industires have difficult in productivity and cost. At this point, this study infers the learning rate of the oil industries and investigates the productivity and growth of them. In conclusion, this study presents the direction of the oil industries' development. With the intention of this objects, this study seizes the status which is concerned the total quantity, the operating rate, the plant capacity, the indicators concerning productivity, the investment of R & D and the scales, and then, infers and verifies the relevancy in connection with the learning rate. In the oil industry, the average rate of learning is 65.96% from 1982 to 1994 which the total quantity and the average operation time are used to infer the rate. To observe the low rate within a same period of time, this study takes the consequences that the learning rate is almost indentical with them each year. This steady state is caused by a difference between the employee and the decision maker about the acquirement and assimiliated of technology. When the high-quality technologies posses the environment to applicate in the scene of labor with them, this technology applies to the productivities. As the learning rate increases, the productivity has more effectiveness. The result of analysis about the effectiveness of the learning rate follows that the R & D unfoldes to exist and does not contribute to the growth of the oil industry. To analyze the variables of the growth, such as the learning rate, the investement of R & D, the operating rate and the gross value added to property, plant and equipment, the model is established and examined. The business strategy in the oil industry must be developed to achive the internal growth as well as the external.

  • PDF

Prediction of Internal Tube Bundle Failure in High Pressure Feedwater Heater for a Power Generation Boiler by the Operating Record Monitoring (운전기록 모니터링에 의한 발전보일러용 고압 급수가열기 내부 튜브의 파손예측)

  • Kim, Kyeong-seob;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.2
    • /
    • pp.56-61
    • /
    • 2019
  • In this study, the failure analysis of the internal tube occurred in the high pressure feedwater heater for power generation boiler of 500 MW supercritical pressure coal fired power plant was investigated. I suggested a prediction model that can diagnose internal tube failure by changing the position of level control valve on the shell side and the suction flow rate of the boiler feedwater pump. The suggested prediction model is demonstrated through additional cases of feedwater system unbalance. The simultaneous comparison of the shell side level control valve position and the suction flow rate of the boiler feedwater pump compared to the normal operating state value, even in the case of the high pressure feedwater heater for the power boiler, It can be a powerful prediction diagnosis.

Smart Monitoring System to Improve Solar Power System Efficiency (태양광 발전시스템 효율향상을 위한 스마트 모니터링 시스템)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.219-224
    • /
    • 2019
  • The number of solar power installation companies including domestic small scale (50kW or less) is increasing rapidly, but the efficient operation system and management are insufficient. Therefore, a new type of operating system is needed as a maintenance management aspect to maximize the generation amount in the current state rather than the additional function which causes the increase of the generation cost. In this paper, we utilize Big Data and sensor network to maximize the operating efficiency of solar power plant and analyze the expert system to develop power generation prediction technology, module unit fault detection technology, life prediction of inverter components and report technology, maintenance optimization And to develop a smart monitoring system that enables optimal operation of photovoltaic power plants such as development of algorithms and economic analysis.

Study on Local Buckling of District Heating Pipes Using Limit State Design (한계상태 설계법을 이용한 지역난방 열배관의 국부좌굴 연구)

  • Kim, Joo-Yong;Lee, Sang-Youn;Ko, Hyun-Il;Cho, Chong-Du
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.12
    • /
    • pp.1829-1836
    • /
    • 2010
  • The district heating system distributes the heat generated from a cogeneration plant to wider locations. In this process, the district heating pipe (DHP) is subjected to internal and external loadings. The internal loadings are generally caused by the operating conditions such as water temperature and internal pressure. Frictional interactions between the pipes and the soil contribute to the external loadings. Thus, investigation of the mechanisms of failure of DHPs will help to guarantee both mechanical stability and heating efficiency. In this study, we investigate the local buckling of DHPs using limit state design (LSD). Two methods are considered: the use of the limit state for the width-thickness ratio and the use of the limit state for the strain. The results are used to confirm that the DHP is stable under local buckling. Finally, we suggest a minimum preheating temperature for avoiding local buckling.

Facility to study neutronic properties of a hybrid thorium reactor with a source of thermonuclear neutrons based on a magnetic trap

  • Arzhannikov, Andrey V.;Shmakov, Vladimir M.;Modestov, Dmitry G.;Bedenko, Sergey V.;Prikhodko, Vadim V.;Lutsik, Igor O.;Shamanin, Igor V.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2460-2470
    • /
    • 2020
  • To study the thermophysical and neutronic properties of thorium-plutonium fuel, a conceptual design of a hybrid facility consisting of a subcritical Th-Pu reactor core and a source of additional D-D neutrons that places on the axis of the core is proposed. The source of such neutrons is a column of high-temperature plasma held in a long magnetic trap for D-D fusionreactions. This article presents computer simulation results of generation of thermonuclear neutrons in the plasma, facility neutronic properties and the evolution of a fuel nuclide composition in the reactor core. Simulations were performed for an axis-symmetric radially profiled reactor core consisting of zones with various nuclear fuel composition. Such reactor core containing a continuously operating stationary D-D neutron source with a yield intensity of Y = 2 × 1016 neutrons per second can operate as a nuclear hybrid system at its effective coefficient of neutron multiplication 0.95-0.99. Options are proposed for optimizing plasma parameters to increase the neutron yield in order to compensate the effective multiplication factor decreasing and plant power in a long operating cycle (3000-day duration). The obtained simulation results demonstrate the possibility of organizing the stable operation of the proposed hybrid 'fusion-fission' facility.

A Study on Advanced Municipal Wastewater Treatement by Daewoo Nutrients Removal (DNR) System (DNR 시스템에 의한 하수(下水)의 고도처리(高度處理)에 관한 연구(硏究))

  • Park, Myung-Gyun;Chang, Yun-Seok;Park, Chul-Hwi;Park, Chil-Lim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.4
    • /
    • pp.115-123
    • /
    • 1995
  • The purpose of this study is to investigate the characteristics and performance of nitrogen and phosphorus removal system, Daewoo Nutrients Removal(DNR) system, and to find out the operating parameter for the system. During the study, $10m^3$ pilot plant was operated for the demonstration experiment and the primary effluent was taken from K domestic sewage treatment plant. The TN in the influent had been removed to approximately 70% through the nitrfication in the oxic tank and the denitrfication in the anoxic tank and the $PO_4-P$ and TP in the influent had been removed to 85% and 83% through anaerobic reaction and oxic reaction. The BOD and SS removal rate were 85 to 95% through the system. As the results, the values of effluent BOD, SS and slouble phosphorus were lower than A/O and $A^2/O$ processes. The SPRR (specific phosphorus release rate) at the anaerobic state of DNR system was ranged from 2.2 to 2.6mg SP/g VSS/h. The nutrient removal efficieny of the DNR system in view of the characteristics of the domestic sewage was higher than the pre-established A/O and $A^2/O$ processes. Finally, we believe that the DNR system was superior to the processes deveolped recently.

  • PDF

A Novel Noise Reduction Method for Measuring Partial Discharge in High Voltage Electric Machinery (고압 전기설비 부분방전시험을 위한 노이즈 저감방안)

  • Lee, Young-Jun;Park, Kwang-Ha;Choi, Hyung-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2021_2022
    • /
    • 2009
  • Partial discharges(PD) is a important factor to evaluate the insulation state in high voltage electric machinery. However, measuring PD under the circumstances of power plant is occasionally impossible due to the relatively high magnitude of noise which is emanated from the operating machinery. In some case, the instrument measuring PD can not even perform a calibration that initializes tools and enhance the accuracy. This paper presents that we devised a noise reduction method and demonstrated the usefulness in acquiring reliable PD signals. We attached a series of filter and transformer at the input of power source of the instruments which refrains high noise signals from incoming to the instruments. We experimented the efficiency of noise reduction applying the device into the Dangjin Power Plant and Factory. As a result of testing with the filter and transformer, we can easily calibrate the PD signal compared to the case without the device. Additionally, we can detect the small PD signal which was unperceived with a normal device.

  • PDF