• 제목/요약/키워드: Placement Temperature

검색결과 129건 처리시간 0.031초

와동 형태와 충전 방법에 따른 Class V 복합 레진 수복치의 유한요소법적 응력 분석 (FINITE ELEMENT STRESS ANALYSIS OF CLASS V COMPOSITE RESIN RESTORATION SUBJECTED TO CAVITY FORMS AND PLACEMENT METHODS)

  • 손윤희;조병훈;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.91-108
    • /
    • 2000
  • Most of cervical abrasion and erosion lesions show gingival margin where the cavosurface angle is on cementum or dentin. Composite resin restoration of cervical lesion shrink toward enamel margin due to polymerization contraction. This shrinkage has clinical problem such as microleakage and secondary caries. Several methods to diminish contraction stress of composite resin restoration, such as modifying cavity form and building up restorations in several increments have been attempted. The purpose of this study was to compare polymerization contraction stress of composite resin in Class V cavity subjected to cavity forms and placement methods. In this study, finite element model of 5 types of Class V cavity was developed on computer tomogram of maxillary central incisor. The types are : 1) Box cavity 2) Box cavity with incisal bevel 3) V shape cavity 4) V shape cavity with incisal bevel 5) Saucer shape cavity. The placement methods are 1) Incisal first oblique incremental curing 2) Bulk curing. An FEM based program for light activated polymerization is not available. For simulation of curing dynamics, time dependent transient thermal conduction analysis was conducted on each cavity and each placement method. For simulation of polymerization shrinkage, thermal stress analysis was performed with each cavity and each placement method. The time-temperature dependent volume shrinkage rate, elastic modulus, and Poisson's ratio were determined in thermal conduction data. The results were as follows : 1. With all five Class V cavifies, the highest Von Mises stress at the composite-tooth interface occurred at gingival margin. 2. With box cavity, V shape cavity and saucer cavity, Von Mises stress at gingival margin of V shape cavity was lower than the others. And that of box cavity was lower than that of saucer cavity. 3. Preparing bevel at incisal cavosurface margin decreased the rate of stress development in early polymerization stage. 4. Preparing bevel at incisal cavosurface margin of V shape cavity increased the Von Mises stress at gingival margin, but decreased at incisal margin. 5. At incisal margin, stress development by bulk curing method was rapid at early stage. Stress development by first increment of incremental curing method was also rapid but lower than that by bulk curing method, however after second increment curing final stress was the same for two placement methods. 6. At gingival margin, stress development by incremental curing method was suddenly rapid at early stage of second increment curing, but final stress was the same for two placement methods.

  • PDF

초기재령 콘크리트의 역학적 특성 및 온·습도 거동 특성 분석 (Mechanical Behavior and Characteristics of Internal Temperature and Relative Humidity of Concrete at Early Age)

  • 박철우;이봉학;홍성기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권6호
    • /
    • pp.184-194
    • /
    • 2011
  • 이 연구에서는 콘크리트 초기재령시의 역학적 특성을 분석하고 수화반응 및 발열반응으로 인한 콘크리트 내부에서 발생하는 온도 및 상대습도의 변화에 대한 분석을 실시하고자 하였다. 세 가지의 다른 단위시멘트량을 실험변수로 하였으며, 타설 직후부터 콘크리트 내부의 온도 및 상대습도의 변화 계측하기 위하여 새로운 계측시스템을 개발하였다. 단위시멘트량에 압축, 인장 및 휨강도의 변화는 크지 않았으며, 재령 7일 이후에는 증가가 많지 않았다. 각 측정부위별 최고 온도는 타설 후 약 11시간 정도 경과시에 발생되었으며 이후 점차 온도가 낮아지다가 양생 1일 경과 후 거푸집 탈형 이후부터 온도가 하강하기 시작했다. 각 측정부위별, 온도감소 분석 결과, 콘크리트 구조물의 위치 및 노출조건에 따라 온도의 변화가 굉장히 다른 것으로 분석되었으며, 초기재령에서 콘크리트 내부의 상대습도의 변화는 수화반응에 영향을 미치는 단위시멘트량 보다는 외부에 노출된 상태가 더 큰 영향을 미칠 수 있는 것으로 분석되었다.

응결시간제어용 배합과 수평분할을 고려한 고강도 매스콘크리트의 적용성 평가 (Applicability of High-strength Mass Concrete through Setting Time and Horizontally-divided Placement)

  • 조승호;백인관;이동하;노영숙
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권2호
    • /
    • pp.103-113
    • /
    • 2017
  • 고강도 콘크리트를 사용한 기초 부재의 수화열 제어를 위하여 지연형과 표준형 콘크리트 배합설계를 제안하고, 합리적인 타설 높이 구현이 가능하도록 유한요소해석을 실시하였다. 또한, 실물 실험을 통하여 해석결과와 비교하여 온도응력 저감 효과를 평가하였다. $6.5m{\times}6.5m{\times}3.5m$ 크기의 대형 부재에 지연형 및 표준형 콘크리트를 수평분할 타설한 결과, 최고온도 $77^{\circ}C$에서 중심부와 표면부의 온도차를 $25^{\circ}C$ 이내로 관리가 가능한 것으로 나타났다. 또한, 유한요소해석에 의한 온도균열지수가 1.49로 나타나 온도균열에 발생하지 않는 것으로 예측되었다. 지연형 및 표준형 콘크리트의 수평분할 타설이 고강도 매스콘크리트의 수화열에 의한 온도 응력 해소에 효과가 있는 것으로 나타났다.

외부영향요인을 고려한 콘크리트 강도예측 뉴럴 네트워크 모델 (Concrete Strength Prediction Neural Network Model Considering External Factors)

  • 최현욱;이성행;문성우
    • 한국산학기술학회논문지
    • /
    • 제19권12호
    • /
    • pp.7-13
    • /
    • 2018
  • 콘크리트 강도는 시멘트, 물, 자갈, 모래 그리고 혼화재 등 내부영향요인뿐만 아니라 실제 현장에서 발생하는 현장기온과 타설지연시간 등 외부영향요인의 영향을 받게 된다. 본 연구의 목적은 콘크리트 배합설계 시 내부영향요인과 외부영향요인을 고려하여 현장 콘크리트 타설시 최적의 콘크리트 강도를 확보하는 것이다. 본 연구에서는 내부영향요인과 외부영향요인에 대한 수준을 정의하고, 모두 24개의 조합에 대한 콘크리트 강도 테스트를 한 후 콘크리트 강도예측 뉴럴 네트워크 모델을 개발했다. 본 콘크리트 강도예측 뉴럴 네트워크 모델은 현장 콘크리트 타설 시 현장기온과 타설지연시간을 고려하여 콘크리트 강도를 예측하는 기능을 제공한다. 본 콘크리트 강도예측 뉴럴 네트워크 모델은 내부영향요인과 외부영향요인을 분석하고 실제 현장에서 콘크리트를 타설할 때 양생온도와 타설지연시간을 뉴럴 네트워크 입력변수로 처리하여 콘크리트 강도를 예측하는 기능을 제공한다. 시공사는 콘크리트 강도예측 결과를 활용하여 콘크리트 배합을 조정함으로써 현장타설 콘크리트 강도를 관리할 수 있을 것이다.

양생직후 초기재령의 콘크리트 내부 온도와 상대습도의 측정 및 분석 (Investigation of Internal Temperature and Relative Humidity of Concrete Immediately After Mix and Placement)

  • 박철우;박영훈;박용걸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1065-1068
    • /
    • 2008
  • Concrete is still one most common construction materials even in railway structures. As structures become massive and mega-sized, the importance of early age concrete quality control becomes more significant. Among various factors, relative humidity and temperature are the primary factors governing the early age quality. Temperature raise due to cement hydration causes stress, which can develop to cracking with internal and/or external restraints. Exposure conditions including ambient temperature, humidity and wind also significantly affect the cracking behavior of early age concrete. Among many of studies on the early age concrete behavior, investigation on the variation of temperature and relative humidity internal of concrete is not common. That is in part because the difficulties in measuring the relative humidity and temperature inside the concrete. This study used a digital sensor with an appropriate logger to measure internal temperature and relative humidity. This direct measuring method is expected to provide more reliable and comprehensive data acquisition on the early age behavior of concrete.

  • PDF

Effects of a Lift Height on the Thermal Cracking in Wall Structures

  • Kim, Sang-Chel
    • KCI Concrete Journal
    • /
    • 제12권1호
    • /
    • pp.47-56
    • /
    • 2000
  • Once a structure fabricated with mass concrete is in a form of wall such as retaining wall, side walls of a concrete caisson and so on, cracks induced by hydration heat have been known to be governed by exterior restraints which are mainly related to the boundary conditions of the structure. However, it is thought that the degree of restraints can be alleviated considerably only if a lift height of concrete placement or a panel size of the wall is selected properly before construction. As a way of minimizing thermal cracking commonly observed in massive wall-typed structure, this study aimed at evaluating effects of geometrical configuration on the temperature rise and thermal stress through parametric study. Evaluation of the effect was also performed for cement types using anti-sulphate cement, blast furnace slag cement and cement blended with two mineral admixture and one ordinary Portland Cement. so called ternary blended cement. As a result of analytical study, it was found that a lift height of concrete placement is the most important factor in controlling thermal cracking in massive wall, and the increase of a lift height is not always positive to the crack occurrence as not expected.

  • PDF

타설온도 및 혼화재 치환에 따른 고강도콘크리트의 단열온도상승에 관한 연구 (Study on the Adiabatic Temperature Rise of High Strength Concrete with Design Compressive Strength and Mixing Temperature)

  • 이병천;김규용;구경모;남정수;함은영;이보경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.101-102
    • /
    • 2012
  • In this study, it was evaluated about hydration heat reduction under hot weather condition. Placement temperature set 25℃ and 35℃, For hydration heat reduction was applied such as FA and BFS. As a results, mixture of BFS70% is the most effective hydration temperature reduction.

  • PDF

Characteristics Analysis of the Heat Exchange Rate according to Soil Temperature and Grout Material using Numerical Simulation

  • Oh, Jin Hwan;Nam, Yu Jin
    • KIEAE Journal
    • /
    • 제14권2호
    • /
    • pp.29-36
    • /
    • 2014
  • The ground source heat pump (GSHP) system has attracted much of attention, because of its stability of heat production and the high efficiency of the system. Performance of the heat exchanger is dependent on the soil temperature, the ground thermal conductivity, the operation schedule, the pipe placement and the design temperature. However, in spite of the many variables of these systems, there have been few research on the effect of the systems on system performance. In this study, analysis of the heat exchange rate according to soil temperature and grout material was conducted by numerical simulation. Furthermore, the heat distribution around the ground heat exchanger was presented on the different conditions of grout and underground temperature by the simulation.

콘크리트 포장의 포설시기가 시공초기의 균열 발생 패턴에 미치는 영향 (Effects of the Placement Time on the Early-Age Crack Patterns of Concrete Pavements)

  • 서영찬
    • 대한토목학회논문집
    • /
    • 제13권2호
    • /
    • pp.135-139
    • /
    • 1993
  • 최근 미국 휴스턴에서 실시된 대규모 시험포장에서 포설계절이 콘크리트포장의 시공초기의 균열발생 패턴에 큰 영향을 준다는 사실이 발견되었는데, 그 내용은 더운계절 시공은 선선한 계절의 시공보다 훨씬 많은 초기균열을 유발시키며, 더운계절시공의 경우 아침일찍 포설한 부분이 오후에 포설한 부분보다 훨씬 많은 초기균열을 유발시킨다는 것이다. 여기서 초기 균열이라 함은 포설후 며칠 이내에 발생하는 균열을 말하며, 대체로 균열틈이 과도하게 벌어지고 균열모양도 구불구불하여 결과적으로 콘크리트 포장 수명단축의 원인이 되는 균열들을 말한다. 본 연구의 목적은 콘크리트 포장의 시공에 있어서 어느 계절에 포설했는지 또는 하루중 몇시쯤에 포설했는지 하는등 포설시기가 콘크리트포장의 초기 균열 발생에 미치는 영향을 파악하고 그 원인을 규명하는데 있다. 본 연구에서는 이러한 포설 시기의 영향을 시멘트의 수화작용(hydration)과 외부온도 조건간의 상호 작용을 규명함으로써 설명하였다.

  • PDF

설계변수가 수직밀폐형 지중열교환기 설계길이에 미치는 영향 (Effect of the Design Parameters of Geothermal Heat Exchanger Design Length)

  • 민경천;최재호
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권2호
    • /
    • pp.10-15
    • /
    • 2011
  • A ground loop heat exchanger for the ground source heat pump system is the core equipment determining the thermal performance and initial cost of the system The length and performance of the heat exchanger is dependent on the ground thermal conductivity, the operation hours, the ground loop diameter, the grout, the ground loop arrangement, the pipe placement and the design temperature. The result of this simulation shows that higher thermal conductivity of grouting materials leads to the decrease length of geothermal heat exchanger from 100.0 to 84.4%.