• 제목/요약/키워드: Pitting Corrosion

검색결과 351건 처리시간 0.027초

Nimonic 80A 초내열합금의 경도와 전기화학적부식에 미치는 시효열처리의 효과 (The Effects of Aging Heat Treatments on the Hardness and Electrocemical Corrosion for the Nimonic 80A Superalloy)

  • 나은영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권5호
    • /
    • pp.660-669
    • /
    • 1998
  • In this paper the Hardness and Electro-chemical corrosion of the Nimonic 80A superalloy were studied. It aging heat treatments was carried out at $650^{\circ}C$, $700^{\circ}C$, $750^{\circ}C$,$800^{\circ}C$ and $850^{\circ}C$ with different time of 20min , 30min 1hour, 2hours, 4hours, and 16hours additionally 64hours and 128hours at $650^{\circ}C$. The obtained results were as follows; 1. As aging temperature increased the time for the maximum hardness was reduced from 128hours at $650^{\circ}C$ to 30min at $850^{\circ}C$ whereas the highest hardness was reduced from Hv 381 at $650^{\circ}C$ to Hv 321 at $850^{\circ}C$. 2. In the Electro-chemical corrosion test as a function of aging heat treatment time and tem-perature the corrosion potential was reversely proportional to Hardness which indicated the effects of ${\gamma}/{\gamma}'$ coherency of base material and precipitate. 3. Initiation point of the pitting was observed at grain boundary twin boundary and near${\gamma}'$ pre-cipitates. The results of composition analysis by EDS at this point indicated that sulphur originat-ed from 1N $H_2SO_4$ solution was found in depletion at the grain boundaries and the pit which arouse in the near precipitates were lack of Al Ti and Ni which are the main element of ${\gamma}'$ The depletion of such element was cause breakdown of passive film.

  • PDF

Relationship between the Applied Torque and CCT to obtain the Same Corrosion Resistance for the Plate and Cylindrical Shape Stainless Steels

  • Chang, Hyun Young;Kim, Ki Tae;Kim, Nam In;Kim, Young Sik
    • Corrosion Science and Technology
    • /
    • 제15권2호
    • /
    • pp.58-68
    • /
    • 2016
  • Many industries need the universal standard or technique to obtain the identical CCT regardless of specimen geometries. This study aimed to determine an appropriate applied torque to the cylindrical specimen defining the apparatus and the procedure to measure the temperature of initiating crevice corrosion in tubular shape products such as pipes, tubes and round rods etc; the test method also proved applicable to the plate type specimen. A series of experiments for CCT measurements with the plate type and cylindrical stainless steel specimens of various diameters with different microstructures (austenitic and duplex) and PRENs were conducted to determine the relationship among geometries on CCT. Thus, the apparatus that could measure the CCT of stainless steels with both plate and cylindrical geometries was newly designed. The use of the apparatus facilitated the same CCT value for both geometries only if the specimens were made of the same alloy. The applied torque can be calculated for various diameters of the cylindrical specimens using the following relation; Applied torque, $Nm=-0.0012D^2+0.019D+2.4463$ (D; the diameter of cylindrical specimen, mm). However, upwards of 35 mm diameter cylindrical specimens require 1.58Nm, which is the same torque for the plate type specimen; in addition, this test method cannot be used for cylindrical specimens of less than 15 mm diameter.

중탄산소듐 용액에서 납의 부식방지제인 자연산물질들 (Natural Occurring Substances as Corrosion Inhibitors for Tin inSodium Bicarbonate Solutions)

  • Abdallah, M.;El-Etre, A. Y.;Abdallah, E.;Eid, Salah
    • 대한화학회지
    • /
    • 제53권5호
    • /
    • pp.485-490
    • /
    • 2009
  • 0.1 M 중탄산소듐 용액에서 납전극부식에 대한 로소니아, 감초뿌리 및 카로브 추출물수용액의 부식방지작용에 대한것을 정전류극성방법을 사용해 연구하였다. 이들 물질들의 부식방지작용을 지적해주는 것으로 이들 물질들이 존재할 때 부식속도가 감소하는 것이 발견되었다. 부식방지효율은 추출물농도가 증가하면 증가한다. 이들 추출물의 부식방지작용은 납표면에 이들 추출물이 흡착되어 물질 및 하전이동의 장벽을 만들어 나타내는 것으로 설명되었다. 이들 추출물의 납표면에 흡착은 자발적으로 일어나며, Freundlich 등온흡착을 따르는 것으로 발견되었다. 또한, 변전위양극분극법을 사용해 이들 추출물은 염소를 포함한 용액에서 납의 움푹패이게 하는 부식으로부터 잘 보호해주는 것이 발견되었다.

에어로졸 증착법에 의한 YSZ 코팅된 AA1050 알루미늄 합금의 전기화학적 부식 특성 (Electrochemical Corrosion Properties of YSZ Coated AA1050 Aluminium Alloys Prepared by Aerosol Deposition)

  • 유현삼;임태섭;류정호;박동수;홍성현
    • 한국세라믹학회지
    • /
    • 제48권5호
    • /
    • pp.439-446
    • /
    • 2011
  • Yttria stabilized zirconia (YSZ) coating was formed on AA1050 Al alloys by aerosol deposition (AD), and its electrochemical corrosion properties were investigated in 3.5 wt% NaCl and 0.5M $H_2SO_4$ solutions. The crack-free, dense, and ~5 ${\mu}m$ thick YSZ coating was successfully obtained by AD. The as-deposited coating was composed of cubic-YSZ nanocrystallites of ~10 nm size. The potentiodynamic test indicated that the YSZ coated Al alloy had much lower corrosion current densities (2 nA/$cm^2$) by comparison to uncoated sample and exhibited a passive behavior in anodic branch. Particularly, a pitting breakdown potential could not be identified in $H_2SO_4$. EIS tests revealed that the impedance of YSZ coated sample was ${\sim}10^6{\Omega}cm^2$ in NaCl and ${\sim}10^7{\Omega}cm^2$ in $H_2SO_4$, which was about 3 or 4 orders of magnitude higher than that of uncoated sample. Consequently, the corrosion resistance of Al alloy had been significantly enhanced by the YSZ coating.

이온질화된 공구강 표면의 산화 및 공식거동 (Corrosion and Oxidation Behaviors of ion-nitrided tool Steels)

  • 최한철;이호종;정용운
    • 한국표면공학회지
    • /
    • 제38권3호
    • /
    • pp.126-135
    • /
    • 2005
  • SKD 11 steel has been widely used for tools, metallic mold and die for press working because of its favorable mechanical properties such as high toughness and creep strength as well as excellent oxidation resistance. The ion nitrided tool steel containing Mo results in improvement of corrosion resistance, strength at high temperature and pitting resistance, especially in $Cl^-$ contained environment. But the Mo addition causes a disadvantage such as lower oxidation resistance at elevated temperature. In this study, several effects of ion-disadvantage on the oxidation characteristics for SKD 11 steel with various oxidation temperature were investigated. SKD 11 steels were manufactured by using vacuum furnace and solutionized for 1 hr at $1,050^{\circ}C$. Steel surface was ion nitrided at $500^{\circ}C$ for 1 hr and 5 hr by ion nitriding equipment. ion nitrided specimen were investigated by SEM, OM and hardness tester. Oxidation was carried out by using muffle furnace in air at $500^{\circ}C,\;700^{\circ}C\;and\;900^{\circ}C$ for 1hr, respectively. Oxidation behavior of the ion nitrided specimen was investigated by SEM, EDX and surface roughness tester. The conclusions of this study are as follows: It was found that plasma nitriding for 5 hr at $500^{\circ}C$, compared with ion nitriding for 1 hr at $500^{\circ}C$, had a thick nitrided layer and produced a layer with good wear, corrosion resistance and hardness as nitriding time increased. Nitrided SKD 11 alloy for 1hr showed that wear resistance and hardness decreased, whereas surface roughness increased, compared with nitrided SKD 11 alloy for 5 hr. The oxidation surface at $900^{\circ}C$ showed a good corrosion resistance.

Automated detection of corrosion in used nuclear fuel dry storage canisters using residual neural networks

  • Papamarkou, Theodore;Guy, Hayley;Kroencke, Bryce;Miller, Jordan;Robinette, Preston;Schultz, Daniel;Hinkle, Jacob;Pullum, Laura;Schuman, Catherine;Renshaw, Jeremy;Chatzidakis, Stylianos
    • Nuclear Engineering and Technology
    • /
    • 제53권2호
    • /
    • pp.657-665
    • /
    • 2021
  • Nondestructive evaluation methods play an important role in ensuring component integrity and safety in many industries. Operator fatigue can play a critical role in the reliability of such methods. This is important for inspecting high value assets or assets with a high consequence of failure, such as aerospace and nuclear components. Recent advances in convolution neural networks can support and automate these inspection efforts. This paper proposes using residual neural networks (ResNets) for real-time detection of corrosion, including iron oxide discoloration, pitting and stress corrosion cracking, in dry storage stainless steel canisters housing used nuclear fuel. The proposed approach crops nuclear canister images into smaller tiles, trains a ResNet on these tiles, and classifies images as corroded or intact using the per-image count of tiles predicted as corroded by the ResNet. The results demonstrate that such a deep learning approach allows to detect the locus of corrosion via smaller tiles, and at the same time to infer with high accuracy whether an image comes from a corroded canister. Thereby, the proposed approach holds promise to automate and speed up nuclear fuel canister inspections, to minimize inspection costs, and to partially replace human-conducted onsite inspections, thus reducing radiation doses to personnel.

Effect of Pseudomonas aeruginosa Strain ZK Biofilm on the Mechanical and Corrosion Behavior of 316L Stainless Steel and α-brass

  • Farooq, A.;Zubair, M.;Wadood, H.Z.;Deen, K.M.
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권4호
    • /
    • pp.431-439
    • /
    • 2021
  • This research work aims to investigate the effect of the aerobic bacterium, Pseudomonas aeruginosa on the mechanical and electrochemical properties of the 316L stainless steel and α-brass. These properties of both the alloys were determined after 7 days of exposure to the controlled and inoculated media at 37℃. The microstructural and electrochemical test results revealed the deleterious effects of Pseudomonas aeruginosa. After exposure to the inoculated medium, the scanning electron microscopy (SEM) results showed the larger pitting and formation of relatively dense biofilm on α-brass compared to 316L stainless steel. The tensile strength and hardness of 316L stainless steel were slightly affected after exposure to the controlled and inoculated media. After exposure to the controlled medium and inoculated media, the tensile strength of the α-brass was least affected but a significant decrease in the hardness (from 165 HV to 124 HV) was observed due to the severe attack induced by the Pseudomonas aeruginosa. Similarly, the open-circuit potential of the 316L stainless steel in the inoculated medium was measured to be less active (-410 mV vs Ag/AgCl) than α-brass (-550 mV vs Ag/AgCl). In the inoculated medium, potentiodynamic polarization curves confirmed the severe attack of Pseudomonas aeruginosa on α-brass (7.15 × 10-2 mm/year) compared to 316L stainless steel which registered a corrosion rate of 5.14 × 10-4 mm/year.

TiN 피막 처리된 스테인레스강 교정용 장치물의 금속 유리에 대한 연구 (A STUDY ON METAL RELEASE OF TIN ION-PLATED STAINLESS STEEL ORTHODONTIC APPLIANCES)

  • 김명숙;성재현;권오원
    • 대한치과교정학회지
    • /
    • 제25권1호
    • /
    • pp.43-54
    • /
    • 1995
  • TiN 피막 처리된 스테인레스강 교정용 장치물이, 전해질이 있는 구강내에 장기간 장착될 때 발생할 수 있는 금속 유리 정도를 파악하기 위해 상악 편측에 해당하는 모조 교정 장치를 제작하였다. welding을 실시하고 TiN 피막 처리한 시편을 제1군으로, welding을 실시하지 않고 TiN피 막 처리한 시편을 제2군으로, welding을 실시하고 TiN 피막 처리를 하지 않은 시편을 제3군으로 welding과 TiN 피막 처리를 실시하지 않은 시편을 제4군으로 하여 각 군당 10개씩의 시편을 준비하였다. 각 시편을 인공 타액내에 15일간 침적하여 용액 속에 유리되어 용해된 니켈과 크롬의 누계와 침전물 형태로 존재하는 니켈과 크롬의 양을 측정하여 총량의 차이를 TiN 피막 처리 유무와 welding 유무에 따라 t-test로 검정한 결과, welding을 실시한 두 군중 TiN 피막 처리 한 군에서 금속 유리량이 더 적었으며 , TiN 피막 처리한 두 군중 welding을 실시하지 않은 군에서 금속 유리량이 더 적은 것으로 나타났다. 표면 조직 관찰시 welding을 실시한 두 군에서 수많은 침전물과 Pitting corrosion이 보였으며 이 중 TiN 피막 처리한 군에서 그 정도가 낮았다. 본 실험을 통하여 스테인레스강 교정용 장치물에 TiN 피막 처리시 심미성 및 각종 물성의 개선 이외에도 금속 유리의 정량적인 분석 결과 내식성이 현저히 개선됨을 알 수 있었다.

  • PDF

알루미늄합금 재료의 부식피로거동에 미치는 쇼트피닝 효과에 대한 미시적 분석 (Microscopic Analysis of Effect of Shot Peening on Corrosion Fatigue Behavior of Aluminum Alloy)

  • 김종천;정성균
    • 대한기계학회논문집A
    • /
    • 제36권11호
    • /
    • pp.1381-1389
    • /
    • 2012
  • 본 논문에서는 쇼트피닝 가공한 알루미늄 7075-T6 재료의 부식피로향상에 대한 연구를 하였다. 사용된 알루미늄 금속은 상대적으로 가볍고 강한 재료의 특성으로 항공기 주요부품의 재료로 사용되고 있으며, 많은 연구를 통해 알루미늄을 사용하면 약 50%의 무게 감소효과를 낼 수 있다고 한다. 재료의 부식은 인장환경에서 재료의 파단시점을 앞당기고 구조물의 수명을 심각하게 감소시킨다. 따라서 알루미늄 금속의 부식 환경에서의 재료의 부식저항을 향상 시킬 수 있는 연구가 요구된다. 쇼트피닝 가공은 재료 표면에 압축잔류응력을 인가하여 재료의 피로수명을 늘리고 나아가 재료의 신뢰성을 확보하는 기술로 반복하중을 받는 많은 부품들에 이미 적용되어 사용되고 있다. 부식 환경에서는 가공 후 거칠어진 표면으로 인해 공식부식을 야기하지만, 피닝가공에 의한 표면 직하에 압축잔류응력이 부식을 억제하여 부식저항을 증가시킨다. 본 연구에서의 쇼트피닝가공된 시험편에 대한 실험결과와 선행연구에서의 쇼트피닝 가공하지 않은 알루미늄 합금 재료의 부식피로특성을 비교하였다. 실험 결과 쇼트피닝 가공은 알루미늄합금의 피로수명향상에 영향을 미치고, 압축잔류응력은 부식피로수명을 증가시킴을 알 수 있었다.

수종 임플랜트 금속의 내식성에 관한 전기화학적 연구 (AN ELECTROCHEMICAL STUDY ON THE CORROSION RESISTANCE OF THE VARIOUS IMPLANT METALS)

  • 전진영;김영수
    • 대한치과보철학회지
    • /
    • 제31권3호
    • /
    • pp.423-446
    • /
    • 1993
  • Titanium and its alloys are finding increasing use in medical devices and dental implants. The strong selling point of titanium is its resistance to the highly corrosive body fluids in which an implant must survive. This corrosion resistance is due to a tenacious passive oxide or film which exists on the metal's surface and renders it passive. Potentiodynamic polarization measurement is one of the most commonly used electro-chemical methods that have been applied to measure corrosion rates. And the potentiodynamic polarization test supplies detailed information such as open circuit, rupture, and passivation potential. Furthermore, it indicates the passive range and sensitivity to pitting corrosion. This study was designed to compare the corrosion resistance of the commonly used dental implant materials such as CP Ti, Ti-6A1-4V, Co-Cr-Mo alloy, and 316L stainless steel. And the effects of galvanic couples between titanium and the dental alloys were assessed for their useful-ness-as. materials for superstructure. The working electrode is the specimen , the reference electrode is a saturated calomel electrode (SCE), and the counter electrode is made of carbon. In $N_2-saturated$ 0.9% NaCl solutions, the potential scanning was performed starting from -800mV (SCE) and the scan rate was 1 mV/sec. At least three different polarization measurements were carried out for each material on separate specimen. The galvanic corrosion measurements were conducted in the zero-shunt ammeter with an implant supraconstruction surface ratio of 1:1. The contact current density was recorded over a 24-hour period. The results were as follows : 1. In potential-time curve, all specimens became increasingly more noble after immersion in the test solution and reached between -70mV and 50mV (SCE) respectively after 12 hours. 2. The Ti and Ti alloy in the saline solution were most resistant to corrosion. They showed the typical passive behavior which was exhibited over the entire experimental range. Therefore no breakdown potentials were observed. 3. Comparing the rupture potentials, Ti and Ti alloy had the high(:st value (because their break-down potentials were not observed in this study potential range ) followed by Co-Cr-Mo alloy and stainless steel (316L). So , the corrosion resistance of titanium was cecellent, Co-Cr-Mo alloy slightly inferior and stainless steel (316L) much less. 4. The contact current density sinks faster than any other galvanic couple in the case of Ti/gold alloy. 5. Ag-Pd alloy coupled with Ti yielded high current density in the early stage. Furthermore, Ti became anodic. 6. Ti/Ni-Cr alloy showed a relatively high galvanic current and a tendency to increase.

  • PDF