• 제목/요약/키워드: Pipe Flow Analysis

검색결과 637건 처리시간 0.032초

Improvement of the CCFL Model of the RELAP5/MOD3.2.2B Code in a Horizontal Pipe

  • Heo, Sun;No, Hee-Cheon;Chang, Kyung-Sung;Ha, Sang-Jun
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1999년도 춘계학술발표회요약집
    • /
    • pp.115-115
    • /
    • 1999
  • To demonstrate the applicability of RELAP5 to the prediction of the onset offlooding in the hot leg at the reflux condensation phase during mid-loop operation, numerical analysis is performed for the counter-current flow in a horizontal pipe with the inclined riser using the RELAP5/MOD3.2.2b code. It is found that the RELAP5, simulating the CCFL phenomena using interfacial friction along with the flow regime map in the horizontal pipe, produces unsatisfactory results. Under the CCFL condition, it is observed that large oscillation exists in the flow rate, void fraction, and etc. and the liquid flow rate is much lower than that predicted by the CCFL model measured in the experiment. The CCFL model of RELAP5 for the vertical volume is extended to the model for the horizontal and inclined volumes. The horizontal volume flow regime map and interfacial friction model coupled to the CCFL model are modified. And a new correlation developed from Kang's experiment is implemented to the CCFL model of RELAP5. With this modified RELAP5, the analysis of CCFL phenomena in the horizontal pipe and hot leg geometry is performed, and produces reasonable results in comparison with experimental data.

  • PDF

하나로 유동모의 설비의 유체순환계통 해석 (The Analysis of Flow Circulation System for HANARO Flow Simulated Test Facility)

  • 박용철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.419-424
    • /
    • 2002
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality In February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulation facility is being developed for the endurance test of reactivity control units for extended life times and the verification of structural integrity of those experimental facilities prior to loading in the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The flow circulation system is composed of a circulation pump, a core flow pipe, a core bypass flow pipe and instruments. The system is to be filled with de-mineralized water and the flow should be met the design flow to simulate similar flow characteristics in the core channel of the half-core test facility to the HANARO. This paper, therefore, describes an analytical analysis to study the flow behavior of the system. The computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with standard k-$\epsilon$ turbulence model and for the verification of the structural piping integrity through the finite element method. The results of the analysis are satisfied the design requirements and structural piping integrity of flow circulation system.

  • PDF

원자로배수탱크내 Sparger에 대한 유동특성 및 최적설계 (Flow Characteristics and Optimal Design for RDT Sparger)

  • 김광추;박만홍;박경식;이종원
    • 대한기계학회논문집B
    • /
    • 제23권11호
    • /
    • pp.1390-1398
    • /
    • 1999
  • A numerical analysis for ROT sparger of PWR(Pressurized Water Reactor) is carried out. Computation is performed to investigate the flow characteristics as the change of design factor. As the result of this study, RDT sparger's flow resistance coefficient is K=3.53 at the present design condition if engineering mar&in is considered with 20%, and flow ratio into branch pipe is $Q_s/Q_i=0.41$. Velocity distribution at exit is not uniform because of separation in branch pipe. In the change of inlet flow rate and section area ratio of branch pipe for main pipe, flow resistance coefficient is increased as $Q_s/Q_i$ decreasing, but in the change of branch angle and outlet nozzle diameter of main pipe, flow resistance coefficient is decreased as $Q_s/Q_i$ decreasing. As the change rate of $Q_s/Q_i$ is the larger, the change rate of flow resistance coefficient is the larger. The change rate of pressure loss is the largest change as section area ratio changing. The optimal design condition of sparger is estimated as the outlet nozzle diameter ratio of main pipe is $D_s/D_i=0.333$, the section area ratio is $A_s/A_i=0.2$ and the branch angle is ${\alpha}=55^{\circ}$.

가압기 밀림관 수평배관 외부 가열에 의한 열성층 유동 완화 수치해석 (Numerical analysis for mitigating thermal stratification flow of pressurizer surge horizontal pipe by outside heating)

  • 정일석;김유
    • 대한기계학회논문집B
    • /
    • 제21권5호
    • /
    • pp.670-678
    • /
    • 1997
  • A method to mitigate the thermal stratification phenomenon of pressurizer surge line is proposed by heating bottom outside of horizontal pipe. Unsteady two dimensional model has been used to numerically investigate an effect of heating the bottom of pipe. The dimensionless governing equations are solved by using the control volume formulation and SIMPLE algorithm. Temperature and streamline profiles of fluids and pipe walls with time are compared with the previous study result. The numerical result of this study shows that the outside heating can relaxate the thermal stratification flow of the pressurizer surge line. Maximum dimensionless temperature difference between hot and cold sections of the pipe inner wall which causes thermal stratification was reduced from 0.514 to 0.424 at dimensionless time 1, 632 and 1, 500 respectively.

전기저항 용접강관의 홈부식에 미치는 유동 해석 (Analysis of Flow on Grooving Corrosion at the Weld of a Carbon Steel pipe made by Electrical Resistance Welding)

  • 김용;장혁;류덕희;김재성;이보영;부준홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1-6
    • /
    • 2004
  • Lots of researches were gone already about grooving corrosion mechanism of ERW carbon steel pipe. But there is seldom study for water hammer happened by fluid and acceleration of corrosion rate by incresed flow velocity. Therefore, in this study carried out the analysis based on hydrodynamic and fracture mechanics. Analyzed stress that act on a pipe using ANSYS as a program, and also FLUENT and STAR-CD were used for flow phenomenon confirmation. As the result, fatigue failure is happened by water hammer and corrosion rate was increased because of turbulent flow.

  • PDF

난류모형을 적용한 장애물이 있는 파이프내의 유동장 수치시뮬레이션 (Numerical Simulation of Pipe Flow with an Obstacle by applying Turbulent Models)

  • 곽승현
    • 한국항해항만학회지
    • /
    • 제29권6호
    • /
    • pp.523-528
    • /
    • 2005
  • 장애물이 있는 배관속의 점성유동을 다양한 난류모형을 적용하여 해석하였다. 적용한 난류모형은 k-$\epsilon$, k-$\omega$, Spalart-Allmaras, Reynolds stress 이고, 배관내의 격자는 구조격자(structured grid) 이다. 속도벡터, 압력분포 반복계산(iteration)에 의한 잔류치(residual), 양정(dynamic head) 등을 모사하였다. 4개의 난류모형을 배관유동에 적용하였고 상용 프로그램을 사용하여 해석을 수행하였다.

CFD를 이용한 고압파이프 파단 시 초음속제트의 압축성유동 특성에 관한 수치해석 (Numerical Analysis on the Compressible Flow Characteristics of Supersonic Jet Caused by High-Pressure Pipe Rupture Using CFD)

  • 정종길;김광추;윤준규
    • 대한기계학회논문집B
    • /
    • 제41권10호
    • /
    • pp.649-657
    • /
    • 2017
  • 고압의 파이프 파단 시 파이프 내에 있던 유체가 고속으로 대기로 분출될 때 압축성유동을 동반하는 초음속제트가 발생한다. 이러한 초음속제트는 일반적으로 복잡한 비정상거동을 보여줄 수 있다. 본 연구는 이러한 고압파이프에서 분출되는 초음속제트에 의해 생성되는 압축성유동을 고찰하기 위하여 전산유체역학 해석이 수행되었다. 분출기체의 종류 및 파이프직경 변화에 따른 비정상유동 특성을 해석하기 위해 SST $k-{\omega}$ 난류모델이 채택되었다. 전산해석 시 기본 경계조건은 파이프직경 10 cm, 제트 압력비 5, 기체온도 300 K로 가정하였다. 그 해석결과로 초음속제트로 인해 생성되는 충격파의 거동이 관찰되었고, 간접적인 영향으로 폭풍파도 발생됨을 알 수 있었다. 기체의 분자량이 가장 작은 $H_2$의 압력파 특성은 안전영역까지의 거리가 가장 짧았으며, 분자량이 비슷한 $N_2$, 공기 및 $O_2$는 큰 차이가 없었다. 또한 파이프직경이 커져 제트에 의한 영향범위도 더욱 증대됨을 알 수 있었다.

관내 유동 해석을 위한 웹기반 자바 프로그램 개발 (DEVELOPMENT OF WEB-BASED JAVA PROGRAM FOR NUMERICAL ANALYSIS OF PIPE FLOW)

  • 김경성;박종천
    • 한국전산유체공학회지
    • /
    • 제15권1호
    • /
    • pp.88-94
    • /
    • 2010
  • In general, flow analysis programs have been built in not JAVA language but such as Fortran, C or C++ because of a merit in performance of computation. However, most developer of those languages are not free for use. User should purchase the development tools of programs, and install it on their own computer. Fortunately, JAVA is a free software, and can be used to develop WEB-based programs. It is well known that the JAVA language is time consuming for calculating. However, the performance of computer power has been increased continuously, so it is sure that the former states can be overcome. In the present study, a flow analysis program, which is interactive with Graphics, using the Web-based programing language, JAVA, has been developed for solving the two-dimensional flow motion.

기존 합류식 하수관거에 CSO 제어를 위한 하수분리관의 설치에 관한 연구 (A Study on the Installation of a Sewage Separator Pipe inside an Existing Combined Sewer System for CSO Control)

  • 게라 하이디;김영철
    • 한국습지학회지
    • /
    • 제23권1호
    • /
    • pp.85-93
    • /
    • 2021
  • 유역으로부터 발생되는 강우유출수가 하수관거로 유입되는 것을 방지하기 위하여 별도의 우수전용관을 설치하는 것은 많은 비용이 수반되며 현장 시공여건에 따라 대단히 어려운 경우가 있다. 본 논문에서는 교통 및 도로 여건상 시공이 어려운 곳에 경제적인 접근방법으로 기존의 하수관거에 별도의 하수분리관을 설치하는 단순하면서 혁신적인 방안에 관한 연구결과를 제시하였다. 실험실 규모의 하수관거 실험장치를 통하여 얻은 결과에 따르면 기존의 관거를 하수 및 우수전용 공간으로 분리할 경우 관내유속을 증가시켜TSS, TCOD, TN, TP 퇴적율을 각각 74-88%, 79-90%, 75%, and 67-90%, 정도 감소시킬 수 있는 것으로 나타났다. 또한 3차원 수리유동 모의결과 하수분리관의 설치가 직선구간, 접속구간, 곡선 및 낙차구간에서 하수의 흐름 및 유속분포에 미치는 영향이 미미한 것으로 분석되었다. 그러나 접속구간에 분리관을 설치할 경우 접속면 지역은 유입되는 강우유출수의 운동에너지에 의한 구조물 훼손을 방지하기 위하여 보강해야 할 것으로 판단된다. 또한 곡선부에서 분리관은 곡선부의 안쪽보다는 외곽쪽에 설치하는 것이 구조적으로 안정 적인 것으로 분석된다. 이와 같은 연구결과를 바탕으로 폭 3 m 제원을 갖는 하수관거에는 약 0.4 m × 0.4 m 분리관 설치가 적합한 것으로 나타났다.

경계조건변화에 따른 동력전달관로의 동특성 (Dynamic Characteristics of Pressure Propagation According to Boundary Condition Changes in a Transmission Line)

  • 나기대;유영태;김지환
    • 한국공작기계학회논문집
    • /
    • 제11권6호
    • /
    • pp.75-82
    • /
    • 2002
  • Design for a quiet operation of fluid power system requires the understanding of noise and vibration characteristics of the system. It's not easy to analyze noise problem in hydraulic cylinder used in typical actuator Because they've got complex fluid dynamics. One of the fundamental problems associated with the hydraulic system is the pulsating flow in pipe lines, which can be tackled by the analysis under simplifying assumptions. The present study focuses on theoretic analysis and experimental study on the dynamics of laminar pulsating flow in a circular pipe. We analyze the propagation characteristics of the pressure pulse within a hydraulic pipe line taking into account the pulsating flow frequency variation. We also measure instantaneous pressure pulses within pipe line to identify the transfer functions. We conduct series of experiments to investigate the propagation characteristics of pressure pulse for various pressure of pulsating flow. The working fluid of the present study is ISO VG46 and the temperature ranges from 20 to $60^{\circ}$ with normal pressure at 4000kPa. The flow rate is measured by using an ultrasonic flow meter. Pressures at fixed upstream and downstream positions are measured concurrently. The electric signals of the pressure sensor are stored and analyzed using a system analyzer(PKE 983 series). The frequency is varied in the range of 10~500Hz. The Reynolds number is kept below 2,000. In the present study, boundary condition was varied by installing a surge tank and an orifice at the end of pipe. Experimental and theoretical results were compared each other under various boundary conditions.