• 제목/요약/키워드: Pipe Construction

검색결과 714건 처리시간 0.027초

재사용 파이프서포트(V2)의 품질관리 향상에 관한 연구 (A Study on Quality Management Improvement of Used Pipe Support(V2))

  • 박종근;최명기
    • 한국안전학회지
    • /
    • 제34권3호
    • /
    • pp.36-41
    • /
    • 2019
  • As the prefabricated shoring system structure, which is a temporary structure, is often collapsed due to various reasons during concrete pouring, and directly affects not only the safety of the workers but also the quality of the final building, it is necessary to ensure the safety. It is considered that the pipe supports which are widely used as the prefabricated shoring materials in the construction site do not satisfy the performance criteria in many cases. Therefore, this study investigated the detailed conditions for satisfying the performance criteria and suggested the factors for improving the quality control level in order to prevent collapse accidents due to pipe supports reused at the construction site, As the results of test in order to understand the effect of the pipe supports (V2), which are being reused in the field, on the performance by factor, the performance was evaluated to be high in case of the small female screw clearance and the supporting pin with 12mm in diameter or larger.

진동형 히트 파이프를 이용한 하계 매스 콘크리트의 수화열 냉각에 관한 실험적 고찰 (An Experimental Study on Cooling of Hydration Heat of Mass Concrete Structure using Pulsating Heat Pipe in Summer Season)

  • 양태진;김정훈;김종수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권1호
    • /
    • pp.51-57
    • /
    • 2007
  • In process of reinforced concrete (RC) box structure. the heat of hydration may cause serious thermal cracking. In order to eliminate hydration heat of mass concrete. this paper reports results of hydration heat control in mass concrete structure using the pulsating heat pipe. There were three RC box molds($1.2{\times}l.8{\times}2.4m^3$) which shows a difference as compared with each other. One was not equipped with pulsating heat pipe. The others were equipped with pulsating heat pipe. All of them were cooled with natural air convection. The pulsating heat pipe was composed of serpentine type copper pipe with 10 turns (outer diameter: 4mm. inner diameter: 2.8mm). The working fluid was R-22 and its charging ratio was 40% by volume. The conditions such as the number of turns. the length and the pitch of the pulsating heat pipe and the size of concrete structure were changed. Based on these experiments, it was confirmed that this construction method using pulsating heat pipe was effective to remove hydration heat of mass concrete structure and thus it was possible to prevent harmful thermal crack and construction Period and costs of concrete structure would be cut down.

각형강관을 이용한 슬림플로어 시스템의 층고절감효과 비교 (Comparing floor height reduction effect of slim floor system with square steel pipe)

  • 조윤진;임홍철;김대유;류승일;김도균
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.56-57
    • /
    • 2017
  • In recent years, new construction methods have been required to reduce the construction cost and increase the available area in an environment where construction work is frequently performed in a narrow urban area like Korea. As a result of these studies, slim floor composite beam has been suggested. Slim floor composite beam can reduce required depth because web of steel beam is embedded in the slab, so it is effective to reduce floor height and increase the available area. The purpose of this study is the floor height reduction evaluation by comparing system consisting of reinforced concrete, steel, and slim floor using square-shape steel pipe. After doing structural design for a typical plan, checked effectiveness by comparing each design plan. It is proven that slim floor composite beam can reduce required depth effectively comparing required materials of other system.

  • PDF

사각형 강관을 이용한 비개착 시공에 따른 지반거동의 분석: 수치해석 (A numerical study on the three-dimensional ground movement by the trenchless construction method of concrete box by a square steel pipe supporting system)

  • 최순욱;박영택;장수호;배규진;이기택;백용기
    • 한국터널지하공간학회 논문집
    • /
    • 제14권5호
    • /
    • pp.469-484
    • /
    • 2012
  • 본 연구에서는 기존 도로나 철도 하부에 비개착 공법을 적용하여 입체교차 구조물을 시공할 경우, 비개착공법에 사용되는 사각형 강관의 1개 관입과 전체 강관들의 관입에 따른 상부 지반의 침하와 강관 주변의 변위를 3차원 수치해석으로 분석하여 비개착공사에 따른 지상의 안정성을 파악하고자 하였다. 이상의 수치해석 결과, 사각형 강관 관입에 의한 주변지반의 거동은 수평방향보다 연직방향의 변위에 크게 좌우되며, 토피고가 낮을수록 침하량이 보다 커지는 것으로 파악되었다. 강관 전체를 추진하는 해석에서는 강관들의 추진순서에 따라 침하량이 다소 다르게 나타났으며, 상부에 위치한 사각형 강관들 추진에 의해 발생하는 침하량이 총 침하량의 약 75%를 차지하는 것으로 나타나, 상부 강관 추진 시에 주의 깊은 시공관리가 필요할 것으로 판단되었다.

동절기 수압시험을 대체하는 공기압시험의 적정압력 비교분석에 관한 연구 (Winter to replace the hydraulic test and pneumatic test comparative analysis of study on the optimal pressure)

  • 권영희;황동환;김태길;강경식
    • 대한안전경영과학회지
    • /
    • 제16권2호
    • /
    • pp.211-216
    • /
    • 2014
  • Using a high-rise building water piping after hydrostatic test of the reliability of the leak to be completed if the pressure is maintained until the leak is not commercially available considered. Due to the nature of high-rise buildings and the construction period will take several years from the lower levels of use of the water supply and fire fighting water pipe construction is in progress, the order of which I do most of the first pipe to the construction and more than three years. So kind of riser pipe is complete, install the valve in the basement by installing an automatic pump to maintain a constant pressure after hydrostatic test and after each floor plumbing piping is complete, the progress of the hydrostatic test without undergoing a separate branch pipe the valve is opened automatically when the number of the pressing pressure of the structure. I kind of do and keep working pressure of pipe until the completion of the construction work to keep the damage to human error when it is intended to prepare. In winter, the frost protection and an alternative to drainage water pipe is damaged or deformed, even if unaware of the finishing work to the building, the use of the damage caused by a leak in a after construction of finish work to be expected. Alternative to reduce this damage if the pressure test without fear of freezing to help maintain long-term commercial pressures may be considered.

고강도콘크리트의 고속펌핑을 위한 압송성평가 및 예측모델에 관한 연구 (Development of Evaluation and Prediction Model for Concrete High Speed Pumping)

  • 김형래;조호규;정웅택
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.201-203
    • /
    • 2012
  • The establishment of the technology for evaluating friction resistance and pipe pressure and the relation of the fluid characteristics and pumpability of concrete is essential for the evaluation of concrete pumping performance for high speed construction of super-tall building. So, this study focuses on quantitative evaluation of concrete fluid characteristics and surface friction resistance under the change of concrete mix proportion and pumping condition. In this study, we measured the rheology of concrete and pipe pressure and surface friction characteristics when pumping. And, relations between the rheology characteristics of concrete and pumping performance was investigated by experiment. As the result of the experiment, high regression between the surface friction and pressure gradient was confirmed. And, prediction model to evaluate the friction resistance coefficient and pipe pressure reduction coefficient was suggested.

  • PDF

매설조건에 따른 연성관의 변형특성 (Deformation Characteristics of Flexible Pipe with Variation of Buried Conditions)

  • 이봉직
    • 한국지반환경공학회 논문집
    • /
    • 제15권10호
    • /
    • pp.53-62
    • /
    • 2014
  • 국내의 경우 하수관으로 많이 사용되어 온 관종은 콘크리트 흄관으로 대표되는 강성관이 주를 이루고 있으나, 시간 경과에 따른 관 부식 및 수밀성 부족 등의 이유로 사용이 급격히 감소하고 있다. 반면에 연성관은 부식에 강할 뿐만 아니라 자재의 무게가 경량이어서 시공성이 우수한 장점이 있어 사용이 증가하고 있는 실정이다. 그러나 연성관에 대한 시장의 신뢰성 부족과 미흡한 다짐관리로 인한 국부적인 파손사례가 발생하고 있어 이에 대한 원인분석 및 관리방안이 필요한 실정이다. 이에 본 연구에서는 시공순서, 관의 강성, 관 하부 콘크리트 기초의 강도, 관 하부 모래기초의 다짐도, 관 주변 모래의 다짐도 및 관 상단 되메움재의 다짐도 등을 변화시켜 가며 각각의 조건에 따른 관의 변형특성을 수치해석을 통하여 평가하였다. 평가결과 각 인자에 대한 영향을 확인할 수 있었으며 특히 연성관의 경우 관 주변 모래의 품질관리가 중요한 것으로 나타났다.

비개착 강관압입공법의 지표침하 예측방법 연구 (A Study on Surface Settlement Prediction Method of Trenchless Technology Pipe Jacking Method)

  • 정지승;이규영
    • 한국지반환경공학회 논문집
    • /
    • 제16권11호
    • /
    • pp.29-37
    • /
    • 2015
  • 최근 급격한 도시화로 인한 신도시, 택지개발지구 등의 증가로 기존 구조물 하부를 통과하는 비개착 강관압입공법의 적용이 증가하는 추세이다. 비개착공법은 시공 중 기존구조물의 정상적인 운영 안정성이 확보되어야 하므로 강관압입에 의한 지표침하의 정밀한 예측이 필수적으로 필요한 공법이다. 강관압입 시 침하를 발생시키는 원인은 강관 선단과 강관과의 직경차에 의한 공극, 원활한 강관압입을 위한 과굴착, 강관과 지반과의 마찰에 의한 공극 발생 등이 있으며, 이는 Shield TBM 시공 시 발생하는 침하 원인과 유사하다. 본 연구에서는 Shield TBM의 침하 예측방법인 Gap Parameter Method와 Volume Loss Method를 이용하여 강관압입 시 침하를 예측하였으며, 현장시험을 통하여 예측방법에 대한 비교 분석을 수행하였다. 그 결과 Volume Loss 예측방법이 현장시험과 가장 유사한 결과로 나타났으나, 추후 예측방법의 Factor 결정 및 비개착공법 전체 침하예측을 위한 적용성 등 추가적인 연구가 필요할 것으로 판단된다.

재사용 V4 강재 파이프 서포트의 성능향상 요인에 관한 실험적 연구 (A Experimental Study on Performance Improvement Factors of Used V4 Steel Pipe Support)

  • 최명기;박종근
    • 한국안전학회지
    • /
    • 제35권3호
    • /
    • pp.43-48
    • /
    • 2020
  • It is considered that most of reusable pipe supports, which are used as formwork support posting at construction sites, do not meet the performance standard. Due to the use of reusable pipe supports that do not meet such performance standard the potential risk of collapse accident is increasing. Therefore, this study identifies the status of compliance with performance standard, and presents the requirements for improving quality control to prevent the collapse of pipe supports reused at the construction site. First, if the female thread of the product with no clearance and new support pin with the diameter of 12mm are replaced at the same time for use, it is considered that the performance will be improved. Second, as the quality performance during use can be improved in the case of larger thickness of inner diameter compared to the case of larger thickness of outer diameter, it is necessary to increase the inner pipe thickness greatly than the current thickness. Based on the results of this study, it is expected that the performance the reusable pipe support (V4) can be improved, if the diameter of the support pin is 12mm, the female thread has a small clearance, and the inner tube thickness is 2.3 ~ 2.7mm. In addition, it is considered that other performance improvement factors included in the study results could be used as important data for improving the performance of reusable pipe support.

UHF RFID기반 이동형 파이프 스풀 위치 인식 시스템 개발 (Development Portable Pipe Spool Location-Confirm System Based UHF RFID)

  • 김진석;신용태
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제3권10호
    • /
    • pp.329-336
    • /
    • 2014
  • 플랜트 공사 현장에서 파이프 스풀은 플랜트 설비의 가장 중요한 요소이다. 현재 플랜트 공사장에서 파이프 스풀 관리는 수기 작성을 통해 적재 위치 및 작업 내역을 관리하고 있다. 그러나 현재 현장에서는 작업자의 임의적인 파이프 스풀의 이동과 제작 또는 설치해야 할 파이프 스풀을 찾지 못했을 경우 비슷한 파이프 스풀을 가지고 와 다시 제작하는 현상이 발생하고 있다. 이에 파이프 스풀의 위치를 정확하게 알 수 없기 때문에 파이프 스풀을 찾기 위한 인건비와 시간이 소요되며, 분실에 대한 관리가 되지 않는 상황이다. 이에 파이프 스풀에 UHF RFID 태그를 부착하고 차량에 UHF RFID 리더 및 안테나를 장착하여 파이프 스풀의 위치를 찾을 수 있는 시스템을 제안한다. 제안된 시스템을 활용하여 현장 테스트를 진행한 결과 98% 이상의 위치 정보 인식이 가능했으며, 손실된 2%의 미 인식 태그는 작업자에 의한 보정을 통해 100%의 관리가 가능함을 확인할 수 있었다. 향후 제안된 시스템 도입으로 인건비와 분실 파이프에 대한 관리가 원활하게 이루어질 뿐만 아니라 특정 공간에 적재되어있는 물품관리에도 활용될 것으로 전망한다.