• Title/Summary/Keyword: Piezo1

Search Result 207, Processing Time 0.031 seconds

Design and Performance Evaluation of Mini-Lightweight Piezo-Composite Actuators

  • Tran, Anh Kim;Yoon, Kwang-Joon
    • Advanced Composite Materials
    • /
    • v.18 no.4
    • /
    • pp.327-338
    • /
    • 2009
  • In this paper, through an evaluation process conducted on several designs of mini-LIPCA (Lightweight Piezo-Composite curved Actuator), an optimal design of a mini-LIPCA has been proposed. Comparing with the LIPCA-C2, the design of the mini-LIPCA comes with reduced overall size and a thinner active layer. Since a variation in the number and lay-up of fiber composite layers may strongly affect the performance of the device, one is able to configure several designs of mini-LIPCA. The evaluation process is then followed in order to determine a configuration which characterizes the possibly optimal performance. That is, a design of a mini-LIPCA is said to be optimal if it is capable of producing a maximum out-of-plane displacement. The size of the LIPCA to be investigated was selected to be $10\;mm\;{\times}\;20\;mm$ in which the thickness of PZT plate is about 0.1 mm. The thickness of glass/epoxy and carbon/epoxy are about 0.09 mm and 0.1 mm, respectively. The evaluation process has been conducted thoroughly, i.e., analytical estimation, numerical approximation and the experimental measurement are all involved. Firstly, the design equation was used to calculate essential parameters of proposed lay-up configurations. Secondly, ANSYS, a commercial FEA package, was utilized to estimate displacement outputs of the actuators upon being excited. Finally, experimental measurements were able to verify the predicted results.

Development of a Shear Testing Machine for a Miniature Single Solder Ball Joint using Piezoelectric Loading Device (피에조를 이용한 초소형 단일 솔더볼 연결부의 전단 시험장치 개발)

  • Kwon, Yong-Sang;Ko, Guk-Jong;Kim, Ho-Gyeong
    • Tribology and Lubricants
    • /
    • v.26 no.1
    • /
    • pp.44-51
    • /
    • 2010
  • A miniature shear testing machine was designed and developed, adopting a piezoelectric actuator with mechanical advantage using 4 levers in order to investigate shear behavior of a small solder ball. The final output displacement was initially expected to be 2.88 mm without load resistance, considering the lever ratio of 24 and the piezo displacement of 0.12 mm with an exciting voltage of 10 V. However, the final plunger displacement ${\Delta}{\upsilon}$ can be expected as ${\Delta}{\upsilon}=2.88-3.04{\times}10^{-4}F$ as a function of piezoelectric force F due to the stiffness of various levers and connectors and piezo actuator. The shear behavior of lead-free solder ball in diameter of $760{\mu}m$ was successfully investigated in a speed range of 2 mm/s~0.0035 mm/s using this designed device.

Electro-Fluid-Structural Interaction Simulation of a Valveless Micropump (시뮬레이션을 통한 무밸브 마이크로 펌프의 전기-유체-구조 상호작용에 대한 연구)

  • Li, Guang-Zhe;Goo, Nam-Seo;Han, Cheol-Heui
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.1
    • /
    • pp.7-13
    • /
    • 2008
  • In this paper, the pumping performance of a piezoelectric valveless micropump is simulated with a commercial finite element analysis software, COMSOL Multiphysics. The micropump developed in the previous work is composed of a 4-layer lightweight piezo-composite actuator (LIPCA), a polydimethylsiloxane (PDMS) pump chamber, and two diffusers. The piezoelectric domain, structural domain and fluid domain are coupled in the simulation. Water flow rates are numerically predicted for geometric parameters of the micropump. Based on this study, the micropump is optimally designed to obtain its highest pumping performance.

Fall detection of the elderly through floor vibrations (바닥 진동을 통한 노인 낙상 검출)

  • Kim, Dong-Wan;Ryu, Jong-Hyun;Beack, Seung-Hwa
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.134-139
    • /
    • 2014
  • According to survey, more than 57.2% of the fall which is the most frequent safety accident of the elders takes place at home. This research aims to verify the fall by measuring and analyzing the floor vibration. And the vibration sensor module was designed with piezo film sensor and operation amplifier. The vibration signals are converted to digital signals through the data acquisition device and vibration sensor module. And then modified the signals into frequency domain to obtain characteristic vibration data. The characteristic signals are verified by K-Nearest Neighbor verification, and experimental results shows the recognition rate 93.6%. Also the fall detection sensor module is useful for extract the meaningful data for fall detection. 10 persons are participated for this experiment.

Modeling and analysis of a cliff-mounted piezoelectric sea-wave energy absorption system

  • Athanassoulis, G.A.;Mamis, K.I.
    • Coupled systems mechanics
    • /
    • v.2 no.1
    • /
    • pp.53-83
    • /
    • 2013
  • Sea waves induce significant pressures on coastal surfaces, especially on rocky vertical cliffs or breakwater structures (Peregrine 2003). In the present work, this hydrodynamic pressure is considered as the excitation acting on a piezoelectric material sheet, installed on a vertical cliff, and connected to an external electric circuit (on land). The whole hydro/piezo/electric system is modeled in the context of linear wave theory. The piezoelectric elements are assumed to be small plates, possibly of stack configuration, under a specific wiring. They are connected with an external circuit, modeled by a complex impedance, as usually happens in preliminary studies (Liang and Liao 2011). The piezoelectric elements are subjected to thickness-mode vibrations under the influence of incident harmonic water waves. Full, kinematic and dynamic, coupling is implemented along the water-solid interface, using propagation and evanescent modes (Athanassoulis and Belibassakis 1999). For most energetically interesting conditions the long-wave theory is valid, making the effect of evanescent modes negligible, and permitting us to calculate a closed-form solution for the efficiency of the energy harvesting system. It is found that the efficiency is dependent on two dimensionless hydro/piezo/electric parameters, and may become significant (as high as 30 - 50%) for appropriate combinations of parameter values, which, however, corresponds to exotically flexible piezoelectric materials. The existence or the possibility of constructing such kind of materials formulates a question to material scientists.

그래핀을 이용한 투명 변형율 센서

  • Bae, Sang-Hun;Lee, Yeong-Bin;Kim, Jae-Hyeon;An, Jong-Hyeon
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2012.05a
    • /
    • pp.91.1-91.1
    • /
    • 2012
  • 그래핀의 우수한 기계적 물성에 관한 연구가 보고된 이후 그래핀의 기계적 특성을 이용한 다양한 어플리케이션에 관한 연구가 진행되고 있다. 기계적 특성을 이용한 다양한 어플리케이션 중 가장 대표적인 것은 발생한 스트레인을 측정하는 스트레인 게이지일 것이다. 때문에 본 연구에서는 다양한 기계적 활용 방안 중 스트레인 게이지를 목표로 그래핀을 이용한 스트레인 게이지의 가능성에 관한 실험을 진행하였다. 먼저 그래핀 내에서의 Piezo-resistive 효과에 관한 기초 테스트를 진행을 통해 그래핀의 gauge factor 수치가 2.5가량이 나옴을 확인하였다. 이 때 사용된 그래핀의 경우 Ni 촉매층을 이용하여 CVD 장비를 이용하여 사용되었고 7%의 투과도를 보였다. 추가적으로 이 같은 그래핀의 Piezo-resistive 특성을 이용하여 우리는 두 종류의 변형률 센서를 제작하였다. 한 가지는 기존의 단일 게이지의 경우 미리 지정된 방향의 변형률 정도만을 측정할 수 있다는 단점을 극복하기 위한 rosette 형태의 스트레인 게이지를 제작함으로써 변형률 뿐만 아니라 표면에서 발생하는 주변형률의 방향을 측정할 수 있었다. 또한 제작된 스트레인 센서를 장갑위에 부착 함으로써 다가올 입는 형태의 전사소자에 응용이 가능한 모양의 변형률 센서 제작에 성공하였다.

  • PDF

Using multi-sensor for Development of Multiple Occupants' Activities Classification Model Based on LSTM (다중센서를 활용한 LSTM 기반 재실자 행동 분류 모델 개발)

  • Jin Su Park;Chul Seung Yang;Kyung-Ho Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.1065-1071
    • /
    • 2023
  • In this paper discuss with research developing an LSTM model for classifying the behavior of occupants within a residence. The multi-sensor consists of an IAQ (Indoor Air Quality) sensor that measures indoor air quality, a UWB radar that tracks occupancy detection and location, and a Piezo sensor to measure occupants' biometric information, and collects occupant behavior data such as going out, staying, cooking, cleaning, exercise, and sleep by constructed an experimental environment similar to the actual residential environment. After the data with removed outliers and missing, the LSTM model is used to calculate accuracy, sensitivity, specificity of the occupant behavior classification model, T1 score.

Traffic Correction System Using Vehicle Axles Counts of Piezo Sensors (피에조센서의 차량 축 카운트를 활용한 교통량보정시스템)

  • Jung, Seung-Weon;Oh, Ju-Sam
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.1
    • /
    • pp.277-283
    • /
    • 2021
  • Traffic data by vehicle classification are important data used as basic data in various fields such as road and traffic design. Traffic data is collected through permanent and temporary surveys and is provided as an annual average daily traffic (AATD) in the statistical yearbook of road traffic. permanent surveys are collected through traffic collection equipment (AVC), and the AVC consists of a loop sensor that detects traffic volume and a piezo sensor that detects the number of axes. Due to the nature of the buried type of traffic collection equipment, missing data is generated due to failure of detection equipment. In the existing method, it is corrected through historical data and the trend of traffic around the point. However, this method has a disadvantage in that it does not reflect temporal and spatial characteristics and that the existing data used for correction may also be a correction value. In this study, we proposed a method to correct the missing traffic volume by calculating the axis correction coefficient through the accumulated number of axes acquired by using a piezo sensor that can detect the axis of the vehicle. This has the advantage of being able to reflect temporal and spatial characteristics, which are the limitations of the existing methods, and as a result of comparative evaluation, the error rate was derived lower than that of the existing methods. The traffic volume correction system using axis count is judged as a correction method applicable to the field system with a simple algorithm.

Stress-Sensors with High-Sensitivity Using the Combined Meandering-Patterns

  • Cho, Chun-Hyung;Cha, Ho-Young
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • In this work, the combined meandering-pattern stress-sensors were presented in order to achieve the high sensitivity of stress sensors. Compared to the previous works, which have been using the single meandering-pattern stress-sensors, the sensitivity was approximately observed to increase by 30%~70%. Also, in this paper, more simple and convenient stress-measurement method was presented.

Measurement of Ultrasonic Field Propagation Characteristics in Biological Tissues Using a Two-dimensional Array Hydrophone (2차원 배열 수중청음기를 이용한 생체조직에서의 초음파 음장 전파특성 측정)

  • ;;;;Xiu-Fen Gong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.76-82
    • /
    • 2001
  • Because the biological tissue with inhomogeneous acoustic properties does not keep a particular shape, the measurement of propagation characteristics of ultrasonic fields by the conventional scanning method with a miniature hydrophone is difficult. In this study, a two-dimensional may hydrophone was fabricated using the PVDF (Polyvinylidene fluoride) piezo-electric film and a ultrasonic field measurement system with it was established. For the acoustic field produced by a circular plan transducer with center frequency of 2.25㎒ and 13㎜ in diameter, it was possible to make a fairly accurate field measurement using the hydrophone system. The attenuation coefficients at 2.25 ㎒ for biological tissues were 0.7∼1.3 dB/cm(average; 1.0 dB/cm) in bovine liver, 1.0∼1.8 dB/cm (average; 1.6 dB/cm) in pig liver, 0.9∼2,9 dB/cm(average: 2.1 dB/cm) in bovine muscles, 1.7∼3.3 dB/cm (average; 2.5 dB/cm) in pig muscles.

  • PDF