• Title/Summary/Keyword: Pier protection

Search Result 29, Processing Time 0.03 seconds

Application of Fiber Stone for Bridge Pier Scour Protection (교각 세굴방지를 위한 섬유돌망태의 적용성)

  • Kim, Seong-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.337-340
    • /
    • 2011
  • In this study, qualitative and quantitative evaluations are performed using the hydraulic analysis of fiber stone for bridge pier scour protection. We can consider that the effective scour protection should be suggested from the side of hydraulic stability, structure stability, and permissible tractive force. The perfect verification, however, on the fiber stone for bridge pier scour protection is not sufficient because of short literatures and experiments on the field study. The continuous research, therefore, will be needed to establish reliable verification using literatures investigation and the various experiments on the fiber stone for bridge pier scour protection.

  • PDF

The study of method local scour protection to the existing piers bridge (기존 교각주변의 국부세굴 방지공법에 관한 연구)

  • Park, Sang-Kil;Chang, Tae-Rae;Park, Byung-Yul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.598-602
    • /
    • 2006
  • Local scour is associate with particular local types of vortex around bridge piers. This paper is method of protection local scour for the existing Busan City subway 3 Line bridge piers and Gupo large bridge piers. In order to take design of protection of local scour this bridge piers, We calculate the local scour hole of depth , scour width, riprap construction , filter construction by formulas. We had experimental hydraulic model test for this bridge piers in order to take proof for the calculation of local scour. We knew that the vortex intensifies the local flow velocities and acts to erode sediment from the scour hole and transport it downstream. As the result of hydraulic model test, we could suggest three types method of protection local scour this bridges. We knew that FHWA HEC-18(Richardson et al. 2001: Modified CSU) Formula is useful to checking calculation as application of field. One is pier protection using the sheet piles and riprap, the others are pier protection using the riprap with filter and to make renew Wall-caisson. The best method of protection for the existing Busan City subway 3 Line bridge piers and Gupo large bridge piers is pier protection using the sheet piles and riprap.

  • PDF

Bridge Foundation and Scour (교량기초와 세굴)

  • 곽기석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.11a
    • /
    • pp.168-187
    • /
    • 2002
  • Scour is the physical or chemical attack of flowing water which excavates and carries away material from stream beds and banks. Especially, hydraulic structures such as bridge piers and abutments placed in the channel causes the changes of the flow pattern like acceleration, the formation of vortices, and scour around the structures. Channel scour, especially bridge pier scour is the leading cause of bridge failures. It is very important to apply appropriate methods for both of scour analysis and protection. In this paper, several methods world-widely used for bridge scour analysis and protection are introduced and compared.

  • PDF

The effect of cathodic protection system by means of zinc sacrificial anode on pier in Korea

  • Jeong, Jin-A;Jin, Chung-Kuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1206-1211
    • /
    • 2014
  • This study has been conducted to confirm the effect of sacrificial anode cathodic protection system for 90 days to protect corrosion on pier that is located in Korea. The cathodically protected structure was a slab and a pile cap. Before the construction of cathodic protection system, the macrography was carried out. As a result of the macrography, many corrosion traces were confirmed in this structure. The trace was mainly focused on joint and zones that concrete cover was eliminated. To apply the cathodic protection system, many onsite techniques have been adopted. In addition, to confirm the inner state of steel in concrete properly, a corrosion monitoring sensor (DMS-100, Conclinic Co. Ltd) has been applied. Test factors were corrosion & cathodic protection potential, 4 hour depolarization potential, resistivity and current density. After 90 days from the installation of cathodic protection system, it could confirm that proper corrosion protection effect was obtained by considering the result of tests.

Pier-Scour Characteristics of the Marine Bridge with Ship Impact Protection - Incheon Bridge Case - (선박충돌방지공이 설치된 해상교량의 교각 세굴 특성 분석 - 인천대교를 대상으로 -)

  • Yeo, Woon-Kwang;Ji, Un;Kim, Chang-Sung;Lim, Jong-Chul
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.2
    • /
    • pp.203-211
    • /
    • 2008
  • More recently, the massive marine bridges in a ship passage have been constructed on the sea. Therefore, the ship impact protection for the bridge-piers are installed to consider the possibility of vessel collision danger. Due to the ship impact protection, the pier-scour characteristics are changed in comparison with the condition without the ship impact protection (SIP). In this study, the physical modeling for the Incheon Sea-Crossing Bridge was performed to analyze the pier-scour characteristics with respect to the vessel collision protection. The rigid and movable bed tests were conducted to evaluate the flow pattern, scour depth, and scourhole with and without the ship impact protection. The experimental results for the maximum scour depth is increased 0.24 m in W1 pier at the same location and 2.4 m in W2+3+4 piers due to the SIP installation. Especially, the maximum scour depth in W2+3+4 piers was occurred around the SIP.

Seismic behavior of thin-walled CFST pier-to-base connections with tube confined RC encasement

  • Xuanding Wang;Yue Liao;Jiepeng Liu;Ligui Yang;Xuhong Zhou
    • Steel and Composite Structures
    • /
    • v.50 no.2
    • /
    • pp.217-235
    • /
    • 2024
  • Concrete-filled steel tubes (CFSTs) nowadays are widely used as the main parts of momentous structures, and its connection has gained increasing attention as the complexity in configuration and load transfer mechanism. This paper proposes a novel CFST pier-to-footing incorporating tube-confined RC encasement. Such an innovative approach offers several benefits, including expedited on-site assembly, effective confinement, and collision resistance and corrosion resistance. The seismic behavior of such CFST pier-to-footing connection was studied by testing eight specimens under quasi-static cyclic lateral load. In the experimental research, the influences on the seismic behavior and the order of plastic hinge formation were discussed in detail by changing the footing height, axial compression ratio, number and length of anchored bars, and type of confining tube. All the specimens showed sufficient ductility and energy dissipation, without significant strength degradation. There is no obvious failure in the confined footing, while local buckling can be found in the critical section of the pier. It suggests that the footing provides satisfactory strength protection for the connection.

Analysis of Tidal Stream around Ship Impact Protection of Incheon Bridge Using CFD (CFD를 사용한 인천대교 충돌방지공 주변의 조류 흐름장 해석)

  • Kim, Gunwoo;Oh, Sang Ho;Yi, Jin-Hak;Kwon, Ohjung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.169.2-169.2
    • /
    • 2010
  • Recently, the massive offshore bridges in a ship passage have been constructed on the sea. Therefore, the ship impact protection for the bridge-piers are installed to consider the possibility of vessel collision danger. Due to the ship impact protection, the flow-field characteristics are changed in comparison with the condition without the ship impact protection. Especially, the fluid velocity between the pier and the ship impact protection is possible to increase due to the contraction of the cross sectional area of flow. In this study, the tidal energy magnitude around the ship impact protection of Incheon bridge is assessed by simulating the flow-field by using FLOW-3D software.

  • PDF

Experimental Study for Protection of Local Scouring around Bridge Pier in a Curved Channel (만곡부에 위치한 교각주위의 국부세굴 보호공에 관한 실험적 연구)

  • Choe, In-Ho;Park, Yeong-Jin;Song, Jae-Woo
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.3
    • /
    • pp.269-277
    • /
    • 1998
  • Laboratory flume experiments to investigate the characteristics of the flows and local scour around circular bridge pier in a curved channel are performed. In this study, the effect of a circular collar device for controlling the depth of scour is examined. The scour depth with a collar is about 40% of the scour depth without collar in the straight course of the flume while it is about 44% of the scour depth without collar at the location of 150' in the curved channel. As the results of experiments using the collar of which diameter is twice of pier, the reduction of scour depth is the most effective in a straight channel when the location of collar is 0.2h( h:depth) below the channel bottom. And, the reduction of scour depth is the most effective in a curved channel when the location of collar is 0.1h below the channel bottom.

  • PDF