• Title/Summary/Keyword: Physiological Signals

Search Result 263, Processing Time 0.034 seconds

Canonical Correlation of 3D Visual Fatigue between Subjective and Physiological Measures

  • Won, Myeung Ju;Park, Sang In;Whang, Mincheol
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.6
    • /
    • pp.785-791
    • /
    • 2012
  • Objective: The aim of this study was to investigate the correlation between 3D visual fatigue and physiological measures by canonical correlation analysis enabling to categorical correlation. Background: Few studies have been conducted to investigate the physiological mechanism underlying the visual fatigue caused by processing 3D information which may make the cognitive mechanism overloaded. However, even the previous studies lack validation in terms of the correlation between physiological variables and the visual fatigue. Method: 9 Female and 6 male subjects with a mean age of $22.53{\pm}2.55$ voluntarily participated in this experiment. All participants were asked to report how they felt about their health sate at after viewing 3D. In addition, Low & Hybrid measurement test(Event Related Potential, Steady-state Visual Evoked Potential) and for evaluating cognitive fatigue before and after viewing 3D were performed. The physiological signal were measured with subjective fatigue evaluation before and after in watching the 3D content. For this study suggesting categorical correlation, all measures were categorized into three sets such as included Visual Fatigue set(response time, subjective evaluation), Autonomic Nervous System set(PPG frequency, PPG amplitude, HF/LF ratio), Central Nervous System set(ERP amplitude P4, O1, O2, ERP latency P4, O1, O2, SSVEP S/N ratio P4, O1, O2). Then the correlation of three variables sets, canonical correlation analysis was conducted. Results: The results showed a significant correlation between visual fatigue and physiological measures. However, different variables of visual fatigue were highly correlated to respective HF/LF ratio and to ERP latency(O2). Conclusion: Response time was highly correlated to ERP latency(O2) while the subjective evaluation was to HF/LF ratio. Application: This study may provide the most significant variables for the quantitative evaluation of visual fatigue using HF/LF ratio and ERP latency based human performance and subjective fatigue.

Design and Implementation of Optimal LED Emotional-Lighting Control System (최적의 LED 감성조명 제어 시스템 설계 및 구현)

  • Yun, Su-Jeong;Lin, Chi-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.8
    • /
    • pp.1637-1642
    • /
    • 2015
  • Next-generation applications using technology IT fused to biological signals from the emotional state to extract a lot of research has been, and the sensitivity of the human sensory functions influences the physiological condition known to be the fact that. In this paper, Propose an Emotional-lighting control algorithm using bio-signals. LED lighting for Emotion light is environmentally friendly and has a high efficiency and long life. In particular, LED lights are different colors represent the possible single light sphere advantages. And, Human sensitivity for determining a more accurate biological signals using EEG was collected using EEG equipment sensitivity was determined to analyze the EEG.

Measurement and Analysis of Rodent Biological Signals using Telemetry System (원격측정장치를 이용한 설치류의 생체신호 측정 및 분석)

  • Kim, Chang-Hwan;Hur, Gyeong-Haeng
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.1159-1165
    • /
    • 2011
  • Telemetry techniques of rats have been used for assessing safety pharmacology of drugs and chemicals. Biological signals including blood pressure and heart rate measured under anesthesia were significantly different from those obtained under normal conditions. The stress of restraint in awake animals can also affect the accuracy of physiological evaluation. This paper details the surgery required to allow key cardiovascular parameters to be determined. The telemetric measurement of cardiovascular parameters such as blood pressure, heart rate, electrocardiograph(ECG) established. We carried out the continuous monitoring of cardiovascular parameters using the telemetry system in F344 rats. During the measurement, no significant changes were observed in the heart rate and blood pressure. ECG signals and body temperature were also constant during the measurement of biological signals. With the results of this study, we conclude that this telemetry system can be applied usefully for the assesment of biological parameters in the rats.

A Study for the Analysis of EEG Signals Evoked by Auditory Stimulus using Wavelet Transformations (Wavelet변환을 이용한 청각자극에 의해 유발되는 뇌파의 분석에 관한 연구)

  • Kim, J.H.;Yoo, I.H.;Shin, J.W.;Im, J.J.;Whang, M.C.;Kim, C.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.233-236
    • /
    • 1996
  • We are exposed to the various external stimuli input from the environment, which cause emotional changes based on the characteristics of the stimuli. Unfortunately, there are no quantitative results on relationship between human sensibility and the characteristics of physiological signals. The objective of this study was to quantify EEG signals evoked by auditory stimulation based on the assumption that the analysis of the variability on the characteristics of the EEG waveform may provide the significant information regarding changes in psychological states of the subject. The experiment was devised with seven experimental conditions, which are control and six different types of auditory stimulation. Twenty subjects were used to obtain EEGs while introducing auditory stimulation. Wavelet transformation was employed to analyze the EEG signals. The results showed that the reconstructed signals at the decomposition level revealed the different energy value on the EEG signals. Also, general patterns of EEG signals in rest state compare with negative and positive stimulus were found. This study could be extended to estabilish an algorithm which distinguishes psychophysiological states of the subjects exposed to the auditory stimulation.

  • PDF

Implementation of a portable telemetry system based on wavelet transform. (웨이블릿 알고리즘을 적용한 휴대용 텔레미트리 시스템)

  • 박차훈;서희돈
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.113-116
    • /
    • 2000
  • In this paper presents the portable wireless ECG data detection and diagnosis system based on discreet wavelet transform. An algorithm based on wavelet transform suitable for real time implementation has been developed in order to detect ECG characteristics. In particular, QRS complex, S and T waves may be distinguished form noise, baseline drift or artifacts. Proposed telemetry system that a transmitting media using radio frequency(RF) for the middle range measurement of the physiological signals and receiving media using optical for electromagnetic interference problem. A standard hi-directional serial communication interface between the telemetry system and a personal computer or laptop, allows read-time controlling, diagnosing and monitoring of system. A portable telemetry system within a size. of 65${\times}$125${\times}$45mm consists of three parts: a digital signal processing part for physiological signal detect or diagnose, RF transmitter for data transfer and a optical receiver for command receive. Advantages of proposed telemetry system is wireless middle range(50m) FM transmission, reduce electromagnetic interference to a minimum. which enables a comfortable diagnosis system at home.

  • PDF

Integrative understanding of immune-metabolic interaction

  • Im, Seonyoung;Kim, Hawon;Jeong, Myunghyun;Yang, Hyeon;Hong, Jun Young
    • BMB Reports
    • /
    • v.55 no.6
    • /
    • pp.259-266
    • /
    • 2022
  • Recent studies have revealed that the immune system plays a critical role in various physiological processes beyond its classical pathogen control activity. Even under a sterile condition, various cells and tissues can utilize the immune system to meet a specific demand for proper physiological functions. Particularly, a strong link between immunity and metabolism has been identified. Studies have identified the reciprocal regulation between these two systems. For example, immune signals can regulate metabolism, and metabolism (cellular or systemic) can regulate immunity. In this review, we will summarize recent findings on this reciprocal regulation between immunity and metabolism, and discuss potential biological rules behind this interaction with integrative perspectives.

Deep Learning Network Approach for Pain Recognition Using Physiological Signals (생리적 신호를 이용한 통증 인식을 위한 딥 러닝 네트워크)

  • Phan, Kim Ngan;Lee, Guee-Sang;Yang, Hyung-Jeong;Kim, Soo-Hyung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.11a
    • /
    • pp.1001-1004
    • /
    • 2021
  • Pain is an unpleasant experience for the patient. The recognition and assessment of pain help tailor the treatment to the patient, and they are also challenging in the medical. In this paper, we propose an approach for pain recognition through a deep neural network applied to pre-processed physiological. The proposed approach applies the idea of shortcut connections to concatenate the spatial information of a convolutional neural network and the temporal information of a recurrent neural network. In addition, our proposed approach applies the attention mechanism and achieves competitive performance on the BioVid Heat Pain dataset.

Development of Real-Time Mental Work Load Measurement System using Heart Rate Variability base on Personal Computer (심박변화율을 이용한 PC 기반 실시간 정신작업부하 측정시스템 개발)

  • 고한우;윤용현;양희경;김동윤
    • Science of Emotion and Sensibility
    • /
    • v.4 no.1
    • /
    • pp.1-5
    • /
    • 2001
  • The evaluation of mental workload is measured by subjective ratings, physiological signals. It takes long time to analysis the measured signals and is very tedious and time-consumming work. Therefore, to evaluate the affect of workload effectively, real-time measurement system is required. In this paper, real-time mental workload measurement system using cardiac autonomic indiced which reflect well the mental workload was developed and evaluated. Analyzed indices were HR, IBI, Lorentz plot, CSI, CVI, and LF/HF ratio of heart rate variability. The system was applied to evaluate the affect of arithmetic task and showed good results. This system was consisted of ECG amplifier, A/D converter, and personal computer, and algorithm was implemented using LabVIEW.

  • PDF

Algorithm detecting an evoked potential using the ensemble averaged bispectrum (The ensemble averaged bispectrum을 이용한 유발전위 검출 알고리즘)

  • Choi, J.M.;Bae, B.H.;Kim, S.Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.124-127
    • /
    • 1994
  • A technique based on bispectrun averaging is described for generally recovering the signal waveform from a set of noisy signals with variable signal delay. The technique does not require explicit tune alignment of signals and any initial estimate of signal. The new method is suggested and is compared with other methods. This method are numerically investigated using computer generated-data and a physiological signal and noise Some experimental results for the evoked potential studios that demonstrate the technique are given. The results show the effectiveness of the technique: various potential applications of the technique might be expected.

  • PDF

Preliminary study on physiological changes of hemorrhagic shock in rats (백서에서의 출혈성 쇼크로 인한 생리 변화에 관한 예비 연구)

  • Lee, Ju-Hyung;Kim, Soo-Chan;Lee, Tak-Hyung;Chung, Sang-Won;Kim, Deok-Won
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1075-1076
    • /
    • 2008
  • Hemorrhagic shock is a common cause of death in emergency rooms. The objective evaluation of hemorrhagic shock is very important for early diagnosis and treatment. The purpose of this study is to understand its mechanism by analyzing the changes of bio-signals in hemorrhagic shock using controlled hemorrhage of SD rats. In this study, we constructed a hemorrhagic integrated system to control bleeding and to simultaneously measure bio-signals such as ECG, blood pressure, temperature, and respiration. In order to verify the system, we measured the bio-signals mentioned above while hemorrhagic shock was induced by withdrawing blood (2.5ml/100g/15min) from a femoral vein for 10 rats.

  • PDF