• Title/Summary/Keyword: Physical solvent

Search Result 320, Processing Time 0.024 seconds

Analysis of Surface Properties of PVC Thin Film according to Addition of Non-solvent to PVC-THF Solution (PVC-THF 용액에 비용매 첨가에 따른 PVC 박막의 표면 특성 분석)

  • Lee, Seung Gyu;Moon, Je Cheol;Lee, Won Gyu
    • Applied Chemistry for Engineering
    • /
    • v.33 no.4
    • /
    • pp.367-372
    • /
    • 2022
  • The effect of the addition of a polyvinylchloride (PVC) non-solvent to a PVC-tetrahydrofuran (THF) solution on the surface properties of the PVC thin film was analyzed. The non-solvents used were composed of alcohol-based and non-alcoholic ones. Surface morphologies of PVC thin films according to the addition of the non-solvent were compared. In addition, the hydrophobic properties relying on the surface characteristics were compared. The micro-bubbles generated in the preparation of PVC-THF solution affected the surface morphology of the thin film. In order to implement the normal surface physical properties of the coating thin film at the relatively high concentration of PVC-THF solution, the selection of appropriate drying method was required. When an alcohol-based non-solvent was added, a PVC thin film having a granular porous surface was obtained and exhibited super hydrophobic properties. The volume ratio of the PVC-THF solution to the non-solvent affects the surface shape of the coating thin film. The larger the amount of non-solvent was added, the more advantageous it was to form a super hydrophobic PVC thin film.

Hybridization and Functionalization of Aqueous-based Polyurethanes

  • Chen, Kan-Nan
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.129-129
    • /
    • 2006
  • Conventional solvent-based polyurethane (PU) is well established for wide applications, such as textile treatments, surface coating, adhesive and so on. Due to the demands of safety, economic, and environmental protection, the solvent-based PU is restricted and has been phasing out and aqueous-based PU is becoming the world market trend, which is an environmental friendly product. The chemical resistance, physical and mechanical properties of aqueous-based PU are still not competible with solvent-based PU. Because of aqueous-based PU is a linear thermoplastic polymer with lower average molecular weight. Their improvements are normally performed by a post-curing reaction or a polymer hybridization to enhance the polymer cross-linking density. Hybridization of PU with aqueous-based epoxy resin or acrylate emulsion and then cured by a curing agent for improving the performance properties and reducing the cost of aqueous-based PU.Furthermore, a special function is added to aqueous-based PU increasing the application value, for examples, flame retardation, polymeric dyes, hydrophilic and etc.

  • PDF

Preparation of tungsten metal film by spin coating method

  • Lee, Kwan-Young;Kim, Hak-Ju;Lee, Jung-Ho;Sohn, Il-Hyun;Hwang, Tae-Jin
    • Korea-Australia Rheology Journal
    • /
    • v.14 no.2
    • /
    • pp.71-76
    • /
    • 2002
  • Metal thin films, which are indispensable constituents of ULSI (Ultra Large Scale Integration) circuits, have been fabricated by physical or chemical methods. However, these methods have a drawback of using expensive high vacuum instruments. In this work, the fabrication of tungsten metal film by spin coating was investigated. First of all, inorganic peroxopolytungstic acid (W-IPA) powder, which is soluble in water, was prepared by dissolving metal tungsten in hydrogen peroxide and by evaporating residual solvent. Then, the solution of W-IPA was mixed with organic solvent, which was spin-coated on wafers. And then, tungsten metal films, were obtained after reduction procedure. By selecting an appropriate organic solvent and irradiating UV, the sheet resistance of the tungsten metal film could be remarkably reduced.

Effect of Template Removal on Synthesis of Organic-Inorganic Hybrid Mesoporous MCM-48

  • Zhao, Ya Nan;Li, San Xi;Han, Chong-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.10
    • /
    • pp.3196-3202
    • /
    • 2012
  • Post-synthesis is used to synthesize organic hybrid inorganic mesoporous sieves. In this method, the activity and structure of the base sieve are crucial to obtain the definable hybrid materials. The chemical and physical properties of the base can be largely changed either by the final step of its synthesizing processes, by template removal which is accomplished with the oxidative thermal decomposition (burning) method or by solvent extraction method. In this paper we compared two methods for the post-synthesis of organic hybrid MCM-48. When the template was extracted with HCl/alcohol mixture, the final product showed larger pore size, larger pore volume and better crystallinity compared to the case of the thermal decomposition. The reactivity of the surface silanol group of template free MCM-48 was also checked with an alkylsilylation reagent $CH_2=CHSi(OC_2H_5)_3$. Raman and $^{29}Si$ NMR spectra of MCM-48 in the test reaction indicated that more of the organic group was grafted to the surface of the sample after the template was removed with the solvent extraction method. Direct synthesis of vinyl-MCM-48 was also investigated and its characteristics were compared with the case of post-synthesis. From the results, it was suggested that the structure and chemical reactivity can be maintained in the solvent extraction method and that organic grafting after the solvent extraction can be a good candidate to synthesize a definable hybrid porous material.

Temperature Effect on the Configurational Properties of an n-Decane Chain in Solution

  • Oh, In-Joon;Ree, Tai-Kyue
    • Bulletin of the Korean Chemical Society
    • /
    • v.5 no.4
    • /
    • pp.162-167
    • /
    • 1984
  • Equilibrium and dynamical behaviors of an n-alkane poymer (decane) in solution have been investigated by a molecuar dynamics simulation method. The polymer is assumed to be a chain of elements $(CH_2)$ interconnected by bonds having a fixed bond length and bond angle, but esch bond of the polymer is allowed to execute hindered internal rotation. The calculation explicitly considers the molecular naturer of solvent by including the intermolecular interactions between slovent-solvent molecules and chain element-solvent molecule. We present the results of calculations on (1) equilibrium properties (the solvent molecule-chain element pair correlation function, chain element-chain element pair correlation function, the mean square end-to-end distance and the mean square radius of gyration of the polymer) and (2) dynamic properties (four different autocorrelation functions, namely, the autocorrelation functions for the end-to-end distance and the radius of gyration, and the velocity autocorrelation functions for the center of mass and the end point of the chain). We found that the physical properties of the polymer chain depends sensitively on temperature. Comparison of the present work with other authors' results is also presented.

Hygroscopicity of 1:2 Choline Chloride:Ethylene Glycol Deep Eutectic Solvent: A Hindrance to its Electroplating Industry Adoption

  • Brusas, John Raymund;Dela Pena, Eden May B.
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.387-397
    • /
    • 2021
  • Deep eutectic solvents have been established as feasible metal electroplating solvent alternatives over traditional toxic aqueous plating baths. However, water, either added intentionally or unintentionally, can significantly influence the solvent's physical properties and performance, thereby hindering its industry application. In this study, the hygroscopicity, or the ability to absorb moisture from the environment, of synthesized ethaline (1:2 choline chloride:ethylene glycol) was investigated. The kinematic viscosity, electrical conductivity, electrochemical window, and water content of ethaline were monitored over a 2-week period. Karl Fischer titration tests showed that ethaline exposed to the atmosphere displayed significant hygroscopicity compared to its unexposed counterpart. 1H NMR spectroscopy revealed that water vapor was readily absorbed at the surface due to the hydrophilic groups present in the ethaline molecule. Water uptake resulted in the decrease in viscosity, increase in electrical conductivity and narrowing of the electrochemical window of ethaline. Solution heating at 100℃ removed the absorbed moisture and allowed the recovery of the solvent's initial properties.

Comparison of the Uniaxial Tensile Strength, Elasticity and Thermal Stability between Glutaraldehyde and Glutaraldehyde with Solvent Fixation in Xenograft Cardiovascular Tissue (이종심혈관 조직에 대한 글루타알데하이드 및 용매를 첨가한 고정방법에 따른 장력, 탄력도 및 열성 안정성 비교연구)

  • Cho, Sung-Kyu;Kim, Yong-Jin;Kim, Soo-Hwan;Park, Ji-Eun;Kim, Wong-Han
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.165-174
    • /
    • 2009
  • Background: With the advances of cardiac surgery, the demand for an artificial prosthesis has increased, and this has led to the development and utilization of diverse alternative materials. We conducted this research to improve an artificial prosthesis by examining the changes of the physical qualities, the pressure related tensile strength, the change in elasticity and the thermostability of a xenograft valve (porcine) and pericardium (bovine, porcine) based on the type of fixation liquid we used. Material and Method: The xenograft valves and pericardium were assigned into three groups: the untreated group, the fixed with glutaraldehyde (GA) group and the glutaraldehyde with GA+solvent such as ethanol etc. group. The surgeons carried out each group's physical activities. Each group's uniaxial tension and elasticity was measured and compared. Thermostability testing was conducted and compared between the bovine and porcine pericardium fixed with GA group and the GA+solvent group. Result: On the physical activity test in the surgeon's hand, no significant difference between the groups was sensed on palpation. For suture and tension, the GA+solvent group was slightly firmer than the low GA concentration group. In general, the circumferential uniaxial tension and elasticity of the porcine aortic and pulmonary valves were better in the fixed groups than that in the untreated group. There was no significant difference between the GA and GA+solvent groups (p>0.05). Bovine and porcine pericardium also showed no significant difference between the GA group and the GA+solvent group (p>0.05). When comparing between the groups for each experiment, the elasticity tended to be stronger in most of the higher GA concentration group (porcine pulmonary valve, porcine pericardium). On the thermostability testing of the bovine and porcine pericardium, the GA group and the G+solvent group both had a sudden shrinking point at $80^{\circ}C$ that showed no difference (bovine pericardium: p=0.057, porcine pericardium: p=0.227). Conclusion: When fixing xenograft prosthetic devices with GA, adding a solvent did not cause a loss in pressure-tension, tension-elasticity and thermostability. In addition, more functional solvents or cleansers should be developed for developing better xenografts.

Comparative Characterization of AFC Precipitated Using Vacuum Drying, Dilution Precipitation and Spray Drying (감압건조, 희석침전, 분무건조 방식으로 제조된 무회분석탄의 특성)

  • Kwon, Ho Jung;Choi, Ho Kyung;Jo, Wan Taek;Kim, Sang Do;Yoo, Ji Ho;Chun, Dong Hyuk;Rhim, Young Joon;Lim, Jeong Hwan;Lee, Si Hyun;Rhee, Young Woo
    • Korean Chemical Engineering Research
    • /
    • v.54 no.2
    • /
    • pp.234-238
    • /
    • 2016
  • Solid ash-free coal (AFC) samples recovered from solvent-extracted solution by vacuum drying, dilution precipitation and spray drying methods were compared in terms of physical properties and chemical structure. AFC was prepared by using Kideco coal (Indonesian sub-bituminous coal) and polar N-methyl-2-pyrrolidone (NMP) solvent as raw materials. The physical properties of the AFCs were characterized with proximate, ultimate, and calorific value analysis. In analyzing the chemical structure, FTIR and NMR were used. the proximate analysis showed much reduced ash in the AFCs compared to parent raw coal. The FTIR result showed that the extraction solvent was not fully removed from the AFC prepared by vacuum drying. However, the solvent was not detected in the AFC recovered by using dilution precipitation. Dilution precipitation has advantages over the other two methods, since it can be done at relatively low temperature and separate ash-free coal from extraction solvent more effectively.

Performance Improvement of IPMC(Ionic Polymer Metal Composites) for a Flapping Actuator

  • Lee, Soon-Gie;Park, Hoon-Cheol;Pandita Surya D.;Yoo Young-Tai
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.6
    • /
    • pp.748-755
    • /
    • 2006
  • In this paper, a trade-off design and fabrication of IPMC(Ionic Polymer Metal Composites) as an actuator for a flapping device have been described. Experiments for the internal solvent loss of IPMCs have been conducted for various combinations of cation and solvent in order to find out the best combination of cation and solvent for minimal solvent loss and higher actuation force. From the experiments, it was found that IPMCs with heavy water as their solvent could operate longer. Relations between length/thickness and tip force of IPMCs were also quantitatively identified for the actuator design from the tip force measurement of 200, 400, 640, and $800{\mu}m$ thick IPMCs. All IPMCs thicker than $200{\mu}m$ were processed by casting $Nafion^{TM}$ solution. The shorter and thicker IPMCs tended to generate higher actuation force but lower actuation displacement. To improve surface conductivity and to minimize solvent evaporation due to electrically heated electrodes, gold was sputtered on both surfaces of the cast IPMCs by the Physical Vapor Deposition(PVD) process. For amplification of a short IPMC's small actuation displacement to a large flapping motion, a rack-and-pinion type hinge was used in the flapping device. An insect wing was attached to the IPMC flapping mechanism for its flapping test. In this test, the wing flapping device using the $800{\mu}m$ thick IPMC. could create around $10^{\circ}{\sim}85^{\circ}$ flapping angles and $0.5{\sim}15Hz$ flapping frequencies by applying $3{\sim|}4V$.

Effect of Solvent Annealing on the Characteristics of PEDOT:PSS as a Ammonia Gas Sensor Film (용매열처리에 따른 PEDOT:PSS 암모니아 가스 감지막 특성 변화)

  • Noh, Wang Gyu;Yeom, Se-Hyuk;Lee, Wanghoon;Shin, Han Jae;Kye, Ji Won;Kwak, Giseop;Kim, Se Hyun;Ryu, Si Ok;Han, Dong Cheul
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.96-100
    • /
    • 2017
  • Poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) has been extensively studied as the active material in ammonia gas sensor because of its fast response time, high conductivity and environmental stability. It is well known that a post annealing process for organic devices based on PEDOT:PSS significantly increases the device performance. In this study, we propose the solvent annealing of PEDOT:PSS and investigated its effects. As a results, post solvent annealing on PEDOT:PSS lead to the surface chemical and physical properties change. These changes result in improved conductivity of the PEDOT:PSS. In additional, ammonia sensitivity of solvent annealed PEDOT:PSS become higher than pristine polymer film. The enhancement is mainly caused by the depletion of gas barrier PSS and structural re-forming PEDOT networks. We believe that the post solvent annealing is a promising method to achieve highly sensitivity PEDOT:PSS films for applications in efficient, low-cost and flexible ammonia gas sensor.