• Title/Summary/Keyword: Photovoltaic Generation

Search Result 973, Processing Time 0.025 seconds

Modeling and Simulation Analysis of Grid-Connected Photovoltaic Generation System in terms of Dynamic behavior (계통연계형 태양광발전시스템의 동특성 모델링 및 모의해석)

  • Kim, Eung-Sang;Kim, Seul-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.127-131
    • /
    • 2005
  • The paper addresses modeling and analysis of a grid-connected photovoltaic generation system (PV system). PSCAD/EMIDC. an industry standard simulation tool for studying the transient behavior of electric power system and apparatus. is used to conduct all aspects of model implementation and to carry out extensive simulation study. An equivalent circuit model of a solar cell has been used for modeling solar array. A PWM voltage source inverter (VSI) and its current control scheme have been implemented. A maximum power point tracking (MPPT) technique is employed for drawing the maximum available energy from the PV array. Comprehensive simulation results are presented to examine PV array behaviors and PV system control performance in response to irradiation changes. In addition, dynamic responses of PV array and system to network fault conditions are simulated and analysed

  • PDF

Analysis on the power generation efficiency by the direct sunlight (태양광 발전 시스템별 직사광선에 의한 발전효율 분석)

  • Lee, Jaydy;Rhee, Sang-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.89-91
    • /
    • 2008
  • The photovoltaic industry is growing at a tremendous speed. And it can be one of the key factors for success in the photovoltaic business to choose a suitable system, and setting it up right so as to get a maximum efficiency of the site. Therefore, it is regarded to be necessary to research the efficiency of systems to catch maximum photovoltaic energy. In this research, the expected power generation efficiencies are analysed, and compared with each other. This research considered the direct sunlight only, and the angle between the direction of solar panel and sunlight as factors to affect the power generation. Therefore, only rough analyses and estimations are found on 3 systems of fixed system, double-axes tracking system, and horizontal tracking system.

  • PDF

Performance Evaluation of the Wall-Type BIPV System Based on the Energy Consumption Unit - A Study for University Lecture Building - (에너지 소비 원단위를 기초로 한 벽면부착형 BIPV 시스템의 성능평가에 관한 연구 - 대학교 강의동 건축물을 대상으로 -)

  • Lee, Kang-Guk;Seo, Won-Duck;Hong, Won-Hwa
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.6
    • /
    • pp.25-32
    • /
    • 2011
  • The building integrated photovoltaic(BIPV) system has a double advantage that it reduces costs for exterior materials and PV panels. It allows the construction of a low-energy building without the need for the additional installation space. At the construction planning stage, however, it requires sufficient evaluation on the efficiency and performance. This study was performed to promote the distribution of photovoltaic power generation system by estimating the potential photovoltaic power generation capacity of the BIPV system installed on the university lecture building and by evaluating the characteristics and performances of window, spandrel and combined attachment types via the simulation of generation capacity per unit area.

  • PDF

Field Test Study of Photovoltaic Generation System for Medium and Small-Sized Buildings (중소형 건물 태양광발전시스템의 실증 연구)

  • Kim, Eung-Sang;Kim, Seul-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.561-565
    • /
    • 2006
  • The paper presents a method of assessing the adequate tapaclty of photovoltaic generation systems for public buildings based on analysis of load variation patterns of customers. When PV systems are installed for supplying power for the customer load, reverse power relay is required by the guideline to be installed at the point of common coupling with the power network. The suggested method analyzes daily, weekly and monthly load demand of the customer that Irishes PV system installation, and determines the appropriate rating of the PV system for preventing PV generation from exceeding the customer demand. This work is expected to support renewable energy dissemination projects of public organizations.

  • PDF

3W PV Generation System Development with Solar Tracker (3kW급 추적식 태양광발전 시스템 개발)

  • Kang S.Y.;Park G.N.;Park S.L.;Kim K.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.687-691
    • /
    • 2003
  • In photovoltaic generation, PV module is used to generate the electricity, and this system has been in limelight as nonpolluting alternative energy source. But, as energy density is low and PV module cost is high, there is a disadvantage that initial investment cost go up. In this study, we studied the method of allowing a tracker, adequate to photovoltaic generation, for Increasing the generating. We determined the proper error angle in order to decrease the repeating number of tracking without a reduction of the generating by using our developed simulator. And, we presented the photovoltaic approach tracking control and achieved its experiment. Through the result of experiment, it is expected that the fault rate and the consumption of electric power in a tracker get reduced and its cost become cut down.

  • PDF

The Study of Power Conditioning System for Photovoltaic Power Generation System (태양광 발전용 전력변환장치에 관한 연구)

  • Ryu S.P.;Jeon S.B.;Min B.G.;Seo K.D.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.961-964
    • /
    • 2003
  • Recently, because of the depletion of fossil fuels and the environmental pollution by using fossil fuels and atomic power generation, the interests concerning of new and renewable energy resources are rising rapidly. In this study, the 3kWP photovoltaic power generation system is realized to verify the performance of the PCS developed. The photovoltaic array used in this system is composed of 60 modules of 50Wp capacity. The developed system is tested and the experimental results show the excellent electrical characteristics.

  • PDF

The Analysis of Operation Effect for 3kW Utility interactive PV System (30kW 주택보급계통연계형 태양광발전시스템 운용효율 분석)

  • Park, J.M.;Kim, K.B.;Lim, H.W.;Kim, D.H.;Baek, H.N.;Cho, G.B.
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.231-233
    • /
    • 2003
  • This paper presents experimental operation with utility interactive 3kW photovoltaic generation system. The status of Photovoltaic generation system components and inter-connection and safety equipment will be summarized. This paper discusses property operation state which 3kW utility interactive photovoltaic generation system was analysed from January 2001 to December 2002.

  • PDF

Control Technique of a Utility Interactive Photovoltaic Generation System (계통연계형 태양광발전 시스템의 제어기법)

  • Kim, Dae-Gyun;Jeon, Kee-Young;Hahm, Nyun-Gun;Lee, Sang-Chip;Oh, Bong-Hwan;Chung, Choon-Byeong;Kim, Yong-Joo;Han, Kyung-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.54-56
    • /
    • 2005
  • The paper proposes the solar photovoltaic power generation system method for photovoltaic system to solve the power shortage due the sudden power demand. So that supplied electric power to system at appearance during surplus electric power minute and unit moment link driving with common use system is available, digital PLL circuit system voltage through composition and phase of solar photovoltatic power generation system to do synchronization do. Feed forward controller was applied to get fast current response Solar cell that is changed by solar radiation always kept the maximum output when it used Step up chopper. The dynamic character had checked through simulation used Matlab Sumulink and confirmed through an experiment.

  • PDF

A Study on the Auxiliary Power Generator for Urban Photovoltaic/Wind Hybrid System (도시형 태양광/풍력 복합발전의 보조 전력발생장치 개발에 대한 연구)

  • Park, Se-Jun;Yun, Jeong-Phil;Yoon, Pil-Hyun;Ji, Woon-Seok;Lim, Jung-Yeol;Cha, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.187-191
    • /
    • 2004
  • Photovoltaic and wind power generation have an advantage of unpolluted and unlimited amount of energy resource. Since there is such an advantage in these energies, But photovoltaic system and wind system cannot always generate stable output with ever-changing weather condition. In this paper, the auxiliary power generator for hybrid system(photovoltaic 500[W], wind power generation 400[W]) was suggested. the auxiliary power generator that uses elastic energy of spiral spring to photovoltaic system was also added for present system. when output of photovoltaic system gets lower than 24[V], power was continuously supplied to load through the inverter by charging energy of spiral spring operates in DC generator.

  • PDF

The Development of Photovoltaic Resources Map Concerning Topographical Effect on Gangwon Region (지형효과를 고려한 강원지역의 태양광 발전지도 개발)

  • Jee, Joon-Bum;Zo, Il-Sung;Lee, Kyu-Tae;Lee, Won-Hak
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.2
    • /
    • pp.37-46
    • /
    • 2011
  • The GWNU (Gangnung-Wonju national university) solar radiation model was developed with radiative transfer theory by Iqbal and it is applied the NREL (National Research Energy Laboratory). Input data were collected and accomplished from the model prediction data from RDAPS (Regional Data Assimilated Prediction Model), satellite data and ground observations. And GWNU solar model calculates not only horizontal surface but also complicated terrain surface. Also, We collected the statistical data related on photovoltaic power generation of the Korean Peninsula and analyzed about photovoltaic power efficiency of the Gangwon region. Finally, the solar energy resource and photovoltaic generation possibility map established up with 4 km, 1 km and 180 m resolution on Gangwon region based on actual equipment from Shinan solar plant,statistical data for photovoltaic and complicated topographical effect.