• Title/Summary/Keyword: Photoplethysmography

Search Result 128, Processing Time 0.027 seconds

Heart Response Effect by 1/f Fluctuation Sounds for Emotional Labor on Employee (1/f 수준 별 음악 자극이 감정 노동 종사자의 심장 반응에 미치는 효과)

  • Jeon, Byung-Mu;Whang, Min-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.18 no.3
    • /
    • pp.63-70
    • /
    • 2015
  • This study identified heart response of participants while listening to sounds which have 1/f fluctuations with exponent ${\alpha}$ gradient. The participants were engaged in emotional stress work. Prior studies related to 1/f fluctuation sound have reported that sound source can alleviate psychological and physiological state of users. Subjects of this study were exposed to sound with three levels of ${\alpha}$ gradient. Heart response of subjects were measured with Photoplethysmography(PPG) sensor simultaneously. The dependent variables of this study were beat per minute(BPM), very low frequency percent of pulse rate variability (VLF percent), the standard deviation of all normal RR intervals (SDNN), and high frequency power(HF power). Subject showed arousal response when exposed to sound with exponent ${\alpha}$ gradient of 3 whereas the sound with exponent ${\alpha}$ gradient of 1 and 2 resulted in relax effect. The characteristic of 1/f fluctuation sounds can be applied to alleviate stress for employers under emotional labor.

A Study of Influences Caused by Far Infrared and Anion on Human Body (원적외선과 음이온이 인체에 미치는 효과)

  • Kim, Wan-Gyeom;Kim, Seong-Sam;You, Seung-Hyun;Kil, In-Ho;Kwon, So-Hee;Lee, Ki-Nam
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.9 no.2
    • /
    • pp.93-106
    • /
    • 2005
  • A survey was performed for 2 weeks in October 2004 in order to examine the effects and changes of far infrared and anion of office workers aged 40 and older before and after wearing the underwear. In the survey, questionnaires and photoplethysmography were used to measure the difference between the two tests conducted with one week interval. The findings could be summed up as follows: 1. There was no statistically significant difference in changes of vascular aging points and photoplethysmogram wave form before and after wearing the far infrared and anion underwear but the points showed the increasing tendency(p>0.05). 2. A statistically significant difference was confirmed since the total points of each item in the questionnaires increased after wearing the underwear(p<0.001). 3. In connection with the systemic symptoms, a significant difference was found with increased points in all items except for no. 6 after wearing the underwear(p<0.05). 4. With regard to the difference before and after wearing the underwear depending on the Kidney symptoms, there was a significant difference with increased points in all items except for item no. 1 after wearing the underwear(p<0.05). In conclusion, to put on the underwear with effect of far infrared and anion is believed to smooth metabolism and blood circulation, contributing by thus to promoting health and preventing disease. Further studies with wider sampling of subjects are requested to diversify and refine the findings from this sectional study.

  • PDF

The effect of rewards on developing right user attitudes of elementary school children (보상이 초등학생의 게임 사용 습관에 미치는 영향)

  • Kim, Young-Joo;Kim, Hea Jin;Lee, Jung-Nyun;Whang, Mincheol
    • Journal of Korea Game Society
    • /
    • v.17 no.2
    • /
    • pp.27-34
    • /
    • 2017
  • The study is to drive right users' attitude of internet and smart phones by providing the rewards. It consisted of 4 different types of no compensation, praise card, achievement sticker and cash and its effect on user's behavior was statistically tested. 24 children in grades four through six participated in the study. The task in this study was game of mathematical calculation. The subjective satisfaction about the reward and heart response during the game task were measured. As the results, inactivation of sympathetic and parasympathetic was observed in the case of no compensation while activation in the case of praise card. Therefore, the praise card was observed in greater commitment and satisfaction than the other rewards. The difference between non-compensation and compensation was significant in the subjective satisfaction, but not difference between compensations.

Affective interaction to emotion expressive VR agents (가상현실 에이전트와의 감성적 상호작용 기법)

  • Choi, Ahyoung
    • Journal of the Korea Computer Graphics Society
    • /
    • v.22 no.5
    • /
    • pp.37-47
    • /
    • 2016
  • This study evaluate user feedback such as physiological response and facial expression when subjects play a social decision making game with interactive virtual agent partners. In the social decision making game, subjects will invest some of money or credit in one of projects. Their partners (virtual agents) will also invest in one of the projects. They will interact with different kinds of virtual agents which behave reciprocated or unreciprocated behavior while expressing socially affective facial expression. The total money or credit which the subject earns is contingent on partner's choice. From this study, I observed that subject's appraisal of interaction with cooperative/uncooperative (or friendly/unfriendly) virtual agents in an investment game result in increased autonomic and somatic response, and that these responses were observed by physiological signal and facial expression in real time. For assessing user feedback, Photoplethysmography (PPG) sensor, Galvanic skin response (GSR) sensor while capturing front facial image of the subject from web camera were used. After all trials, subjects asked to answer to questions associated with evaluation how much these interaction with virtual agents affect to their appraisals.

Study on Heart Rate Variability and PSD Analysis of PPG Data for Emotion Recognition (감정 인식을 위한 PPG 데이터의 심박변이도 및 PSD 분석)

  • Choi, Jin-young;Kim, Hyung-shin
    • Journal of Digital Contents Society
    • /
    • v.19 no.1
    • /
    • pp.103-112
    • /
    • 2018
  • In this paper, we propose a method of recognizing emotions using PPG sensor which measures blood flow according to emotion. From the existing PPG signal, we use a method of determining positive emotions and negative emotions in the frequency domain through PSD (Power Spectrum Density). Based on James R. Russell's two-dimensional prototype model, we classify emotions as joy, sadness, irritability, and calmness and examine their association with the magnitude of energy in the frequency domain. It is significant that this study used the same PPG sensor used in wearable devices to measure the top four kinds of emotions in the frequency domain through image experiments. Through the questionnaire, the accuracy, the immersion level according to the individual, the emotional change, and the biofeedback for the image were collected. The proposed method is expected to be various development such as commercial application service using PPG and mobile application prediction service by merging with context information of existing smart phone.

Design of Filter to Reject Motion Artifacts of PPG Signal Using Multiwave Optical Source (다파장 광원을 이용한 광용적 맥파의 동잡음 제거 필터 설계)

  • Park, Heejung;Nam, Jaehyun;Lee, Juwon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.2
    • /
    • pp.101-107
    • /
    • 2014
  • This study is proposed the novel PPG sensor device and the signal processing method to replace the acceleration sensor that is used to reject motion artifacts contained in photoplethysmography(PPG). The proposed method is to reject motion artifacts by an adaptive filter based on the estimated motion artifact by using a blue LED light. To evaluate the performance of the proposed method experimentally, We did design a novel sensor consisted of blue/red LEDs and photo-sensor and implemented, and then rejected the motion artifacts by using an adaptive filter and the implemented sensor. In the results of the experiments, it is shown that the proposed sensor device and signal processing can reconstruct the PPG signal despite the occurrence of motion artifacts, and also that the SNR was 4.5 times of moving average filter. According to the experimental results, the proposed method can be applied to design a low-cost device.

Compensation of the Error Rate for the Non-invasive Sphygmomanometer System Using a Tactile Sensor

  • Jeong, In-Cheol;Choi, Yoo-Nah;Yoon, Hyung-Ro
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.136-141
    • /
    • 2007
  • The Purpose Of This Paper Is To Use A Tactile Sensor To Compensate The Error Rate. Most Automated Sphygmomanometers Use The Oscillometric Method And Characteristic Ratio To Estimate Systolic And Diastolic Blood Pressure. However, Based On The Fact That Maximum Amplitude Of The Oscillometric Waveform And Characteristic Ratio Are Affected By Compliance Of The Aorta And Large Arteries, A Method To Measure The Artery Stiffness By Using A Tactile Sensor Was Chosen In Order To Integrate It With The Sphygmomanometer In The Future Instead Of Using Photoplethysmography. Since Tactile Sensors Have Very Weak Movements, Efforts Were Made To Maintain The Subject's Arm In A Fixed Position, And A 40hz Low Pass Filter Was Used To Eliminate Noise From The Power Source As Well As High Frequency Noise. An Analyzing Program Was Made To Get Time Delay Between The First And Second Peak Of The Averaged Digital Volume Pulse(${\Delta}t_{dvp}$), And The Subject's Height Was Divided By ${\Delta}t_{dvp}$ To Calculate The Stiffness Index Of The Arteries($Si_{dvp}$). Regression Equations Of Systolic And Diastolic Pressure Using $Si_{dvp}$ And Mean Arterial Pressure(Map) Were Computed From The Test Group (60 Subjects) Among A Total Of 121 Subjects(Age: $44.9{\pm}16.5$, Male: Female=40:81) And Were Tested In 61 Subjects To Compensate The Error Rate. Error Rates Considering All Subjects Were Systolic $4.62{\pm}9.39mmhg$, And Diastolic $14.40{\pm}9.62mmhg$, And Those In The Test Set Were $3.48{\pm}9.32mmhg,\;And\;14.34{\pm}9.67mmhg$ Each. Consequently, Error Rates Were Compensated Especially In Diastolic Pressure Using $Si_{dvp}$, Various Slopes From Digital Volume Pulse And Map To Systolic-$1.91{\pm}7.57mmhg$ And Diastolic $0.05{\pm}7.49mmhg$.

An Analysis of Relationship between Self-Reported Anxiety, Depressiveness and Parametors of Heart rate variability based on Photoplethysmography (불안 및 우울에 대한 주관적 설문평가 지표와 맥파 신호 기반의 심박변이도 요소들 간의 상관관계 분석)

  • Lee, Chung-Ki;Yoo, Sun-Kook
    • Science of Emotion and Sensibility
    • /
    • v.15 no.3
    • /
    • pp.345-354
    • /
    • 2012
  • The purpose of this study is finding alternative parameters of the HRV so as to minimize the subjective errors by STAI and BDI, could be have two types of significant correlation levels depending on normalized method. Particularly, the LF/HF presented as the quantitative physiological parameter that can reflect both state-anxiety and trait-anxiety.

  • PDF

Analysis of Arterial Stiffness Variation by Photoplethysmographic DC Component (광용적맥파 비맥동성분에 의한 혈관경직도 변화 분석)

  • Lee, Chung-Keun;Shin, Hang-Sik;Kong, In-Deok;Lee, Myoun-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.109-117
    • /
    • 2011
  • Assuming that photons absorbed by a vessel do not have acute variations, DC component reflect the basal blood volume (or diameter) before blood pulsation. Vascular stiffness and reflection is influenced by changes in basal blood volume (or diameter). This paper describes analysis of the characteristic variations of vascular stiffness, according to relative variations in DC components of the PPG signal (25-75%). For quantitative analysis, we have used parameters that were proposed previously, reflection and stiffness index, and the second derivative of PPG waveform, b/a and d/a. Significantly, the vascular stiffness and reflections were increased according to increase in DC component of the PPG signal for more than about 3% of baseline values. The systolic blood pressure were increased from $113.1{\times}13.18$ to $116.2{\times}13.319$ mmHg, about 2.76% (r = 0.991, P < 0.001) and the AC component of the PPG signal were decreased from $2.073{\times}2.287$ to $1.973{\times}2.2038$ arbitrary unit, about 5.09% (r = -0.993, P < 0.001). It is separated by DC median and correlation analysis was performed for analyzing vascular characteristics according to instantaneous DC variations. There are significant differences between two correlation coefficients in separated data.

Change of the Finger Photoplethysmographic Pulse Shape According to Decrease of Harmonics (고조파 감소에 따른 지첨용적맥파 파형의 변화)

  • Han, Kyung-Sook;Nam, Tong-Hyun;Shin, Sang-Hoon;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.11 no.2
    • /
    • pp.1-12
    • /
    • 2007
  • Objectives: The aim of the present investigation was to determine whether the finger photoplethysmographic waveform of a healthy young man will become analogous to those of healthy old men when the photoplethysmographic harmonic components in the young man decrease. Methods and Results: The finger photoplethysgmoraphy was measured in 21 old men over the age of 60 years and a young men. We acquired the representative pulse waveform of old man by averaging the finger photoplethysmographic waveforms measured in the old men. after the photoplethysmographic harmonic components in the young man were diminished with notch filtering, we compared the representative pulse waveform of old man and the pulse waveforms of which the harmonic components decreased in the young man. The finger photoplethysmographic waveform of the young man became analogous to those of the old men as the photoplethysmographic harmonic components in the young man were diminished with notch filtering. Conclusions: Decrease of the second harmonic component may be a precondition of typical age-related change of the pulse waveform.

  • PDF