Efficient Verification of X-ray Target Replacement for the C-series High Energy Linear Accelerator

  • Cho, Jin Dong;Chun, Minsoo;Son, Jaeman;An, Hyun Joon;Yoon, Jeongmin;Choi, Chang Heon;Kim, Jung-in;Park, Jong Min;Kim, Jin Sung
    • 한국의학물리학회지:의학물리
    • /
    • 제29권3호
    • /
    • pp.92-100
    • /
    • 2018
  • The manufacturer of a linear accelerator (LINAC) has reported that the target melting phenomenon could be caused by a non-recommended output setting and the excessive use of monitor unit (MU) with intensity-modulated radiation therapy (IMRT). Due to these reasons, we observed an unexpected beam interruption during the treatment of a patient in our institution. The target status was inspected and a replacement of the target was determined. After the target replacement, the beam profile was adjusted to the machine commissioning beam data, and the absolute doses-to-water for 6 MV and 10 MV photon beams were calibrated according to American Association of Physicists in Medicine (AAPM) Task Group (TG)-51 protocol. To verify the beam data after target replacement, the beam flatness, symmetry, output factor, and percent depth dose (PDD) were measured and compared with the commissioning data. The difference between the referenced and measured data for flatness and symmetry exhibited a coincidence within 0.3% for both 6 MV and 10 MV, and the difference of the PDD at 10 cm depth ($PDD_{10}$) was also within 0.3% for both photon energies. Also, patient-specific quality assurances (QAs) were performed with gamma analysis using a 2-D diode and ion chamber array detector for eight patients. The average gamma passing rates for all patients for the relative dose distribution was $99.1%{\pm}1.0%$, and those for absolute dose distribution was $97.2%{\pm}2.7%$, which means the gamma analysis results were all clinically acceptable. In this study, we recommend that the beam characteristics, such as beam profile, depth dose, and output factors, should be examined. Further, patient-specific QAs should be performed to verify the changes in the overall beam delivery system when a target replacement is inevitable; although it is more important to check the beam output in a daily routine.

비균질 팬텀에서 소조사면에 대한 필름측정, 회선/중첩 모델과 몬테 카를로 모사의 비교 연구 (Comparison of Film Measurements, Convolution$^{}$erposition Model and Monte Carlo Simulations for Small fields in Heterogeneous Phantoms)

  • 김상노;제이슨손;서태석
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권2호
    • /
    • pp.89-95
    • /
    • 2004
  • 세기조절방사선치료(IMRT)에서는 일반적인 방사선 치료에서 사용되는 조사면에 비해 비교적 작은 크기의 빔조각(beamlet)을 사용하여 방사선의 세기를 조절하는 새로운 치료법으로 이에 대한 비균질 효과는 많은 연구가 필요하다. 우리는 기하학적으로 일정한 비균질 팬텀들에서 몬테카를로 시뮬레이션에 의한 선량값을 라디오크로믹 필름에 의한 선량값과 회선/중첩 방법에 의한 선량 계산 값과 서로 비교하였다. 몬테 카를로 모사를 위하여 EGS4 코드 기반의 BEAM 코드를 사용하였으며 이를 이용하여 Varian 2300C/D 선형가속기의 두부를 호사하였다. 측정과 모사에 사용된 조사면은 1${\times}$1$\textrm{cm}^2$, 2${\times}$2$\textrm{cm}^2$, 그리고 5${\times}$5$\textrm{cm}^2$이었다. 또한 팬텀의 물질은 솔리드 워터, 폐 등가 물질, 뼈 등가 물질을 사용하여 세 경우의 비극질 팬텀들을 설정하여 방사선을 조사하였다. 회선/중첩 방법과 몬테 카를로 방법에 의한 선량 계산치는 광자 측면선량의 경우 $\pm$1 mm, 깊이선량의 경우 $\pm$2% 이내로 선량측정치와 잘 일치함을 볼 수 있었다. 결론적으로 회선/중첩 방법과 몬테 카를로 방법이 소조사면에서도 필름 측정 데이터와 잘 일치함을 확인할 수 있었다.

6 MV 광자선의 측정데이터와 치료계획장치에 의한 계산데이터의 비교 (The Comparison of Beam Data between Measured Beam Data and Calculated Beam Data Using Treatment Planning System)

  • 박성광;조병철;조흥래;안기정
    • 한국의학물리학회지:의학물리
    • /
    • 제16권3호
    • /
    • pp.125-129
    • /
    • 2005
  • 입체조형방사선치료와 세기조절방사선치료를 위해 여러 셈법을 포함한 치료계획장치가 임상에 사용되고 있다. 본 연구에서는 조사면 1$\times$1cm$^{2}$에서 최대 조사면 40$\times$40까지의 빔 데이터를 측정하여 이를 치료계획장치에 넣어 빔 모델링을 수행한 후 측정된 빔 데이터와 계산된 빔 데이터의 차이를 비교 분석하였다. 6 MV 광자선의 빔 데이터를 피형 실리콘 검출기와 radiochromic 필름을 사용하여 측정하였고 측정된 빔 데이터의 빔 모델링은 Pinnalce 7.4f의 자동화 모델링을 사용하였다. 작은 조사면의 경우 측정된 데이터와 계산된 데이터가 측방선량분포에 있어 선량 내 영역에서는 적게 평가되고 반음영 영역에서는 크게 평가됨을 알 수 있었다. 또한 심부선량백분율 곡선의 경우 D$_{max}$ 깊이가 작은 조사면의 경우 2 mm 정도 더 줄어듦을 알 수 있었다. 그러나 조사면 4$\times$4 cm$^{2}$에서 최대 조사면 40$\times$40 cm$^{2}$ 까지의 측방선량분포에 대해서는 측정된 데이터와 계산된 데이터가 잘 일치하였다.

  • PDF

검출기 측정 용적에 따른 Dosimetric Leaf Gap 변화와 정확성 검증에 대한 연구 (Assessment of Dosimetric Leaf Gap According to Measuring Active Volume of Detector)

  • 김대현
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.863-870
    • /
    • 2022
  • DLG (Dosimetric Leaf Gap)와 투과계수는 방사선치료계획 시스템에서 MLC 모델링의 중요 매개변수이다. 본 연구에서는 측정 용적이 다른 검출기를 이용하여 HD-MLC의 DLG와 투과계수를 측정하였고, DLG의 최적화를 통해 방사선 치료계획의 정확성을 평가하였다. 용적이 작은 Semiflux3D, MicroDiamond 검출기로 Dynamic Sweeping Gap 방법을 통해 DLG를 측정하였다. 측정된 DLG 값을 최적화할 수 있도록 10개의 방사선치료계획을 생성하고 QA결과와 비교하였다. 6, 8, 10 MV에서 Semiflux3D로 측정한 DLG는 0.76, 0.83, 0.85 mm 였고, MicroDiomond로 측정한 DLG는 0.78. 0.86, 0.9 mm 였다. 방사선치료계획 시스템에서 검출기로 측정한 DLG와 최적화된 DLG 값으로 생성한 10개의 치료계획을 Postal dosimetry로 QA하여 감마분석 하였다. 6 MV 광자선의 감마분석결과 2 mm/2% 기준에서 DLG 0.78 mm는 평균 94.3%였고, DLG 1.15 mm는 평균 98.4%였다. 10 MV 광자선에서도 DLG 0.9 mm는 평균 91.2%, DLG 1.25 mm는 97.6%였다. HD-MLC의 사용은 방사선치료계획 시스템에 정확한 모델링이 완성되어야 한다. DLG 값을 검출기로 측정하여 임상에 사용할 수 있지만, DLG 값의 최적화가 이루어진다면 환자에게 더 유용한 방사선 치료를 전달할 수 있을 것이다.

VitalBeam 선형가속기의 심부선량백분율과 측방선량분포 측정을 위한 새로운 기준 전리함으로서 스텔스 전리함의 성능 평가 (Performance Evaluation of Stealth Chamber as a Novel Reference Chamber for Measuring Percentage Depth Dose and Profile of VitalBeam Linear Accelerator)

  • 김연래;정진범;강성희;강상원;김경현;정재용;신영주;서태석;이정우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권3호
    • /
    • pp.201-207
    • /
    • 2018
  • The purpose of this study is to evaluate the performance of a "stealth chamber" as a novel reference chamber for measuring percentage depth dose (PDD) and profile of 6, 8 and 10 MV photon energies. The PDD curves and dose profiles with fields ranging from $3{\times}3$ to $25{\times}25cm^2$ were acquired from measurements by using the stealth chamber and CC 13 chamber as reference chamber. All measurements were performed with Varian VitalBeam linear accelerator. In order to assess the performance of stealth chamber, PDD curves and profiles measured with stealth chamber were compared with measurement data using CC13 chamber. For PPDs measured with both chambers, the dosimetric parameters such as $d_{max}$ (depth of maximum dose), $D_{50}$ (PDD at 50 mm depth), and $D_{100}$ (PDD at 100 mm depth) were analyzed. Moreover, root mean square error (RMSE) values for profiles at $d_{max}$ and 100 mm depth were evaluated. The measured PDDs and profiles between the stealth chamber and CC13 chamber as reference detector had almost comparable. For PDDs, the evaluated dosimetric parameters were observed small difference (<1%) for all energies and field sizes, except for $d_{max}$ less than 2 mm. In addition, the difference of RMSEs for profiles at $d_{max}$ and 100 mm depth was similar for both chambers. This study confirmed that the use of stealth chamber for measuring commission beam data is a feasible as reference chamber for fields ranging from $3{\times}3$ to $20{\times}20cm^2$. Furthermore, it has an advantage with respect to measurement of the small fields (less than $3{\times}3cm^2$ field) although not performed in this study.

피나클치료계획시스템에서 자동모델화과정으로 얻은 Jaw와 다엽콜리메이터의 투과 계수 평가 (Estimation of Jaw and MLC Transmission Factor Obtained by the Auto-modeling Process in the Pinnacle3 Treatment Planning System)

  • 황태진;강세권;정광호;박소아;이미연;김경주;오도훈;배훈식;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.269-276
    • /
    • 2009
  • 세기조절방사선치료(IMRT)뿐만 아니라 3차원 입체조형치료(3D-CRT)와 같이 광자선을 이용한 방사선 치료 기술은 방사선을 받아야 하는 표적의 면적을 충분히 증가시키면서, 동시에 정상 조직은 방사선으로부터 보호하기 위하여 정확한 선량 계산을 필요로 한다. Jaw 콜리메이터와 다엽 콜리메이터가 그러한 목적을 위해서 사용되어 왔다. 우리 기관에서 사용하는 피나클 치료계획시스템은 모델기반의 광자선량 알고리듬을 사용하기 때문에 Jaw 콜리메이터 투과계수(JTF)와 다엽 콜리메이터 투과계수(MLCTF)와 같은 모델변수들의 집합이 측정된 데이터로부터 결정된다. 그러나, 이러한 자동모델화과정에 의해서 얻어진 모델변수들이 직접 측정하여 얻은 것들과 다를 수 있는데, 이는 선량분포에 영향을 줄 수 있다. 그래서, 이 연구에서 우리는 피나클 치료계획시스템에서 자동모델화과정에 의해 얻은 JTF와 MLCTF를 평가하였다. 먼저 우리는 이 연구에서 Jaw 콜리메이터 투과계수(JTF)와 다엽 콜리메이터 투과계수(MLCTF)를 직접 측정하여 얻었는데, 이것은 물팬톰 내 기준깊이에서 조사면이 $0{\times}0\;cm^2$일 때의 선량과 $10{\times}10\;cm^2$일 때의 선량의 비로 얻었다. 또한, JTF와 MLCTF는 치료계획시스템내 자동모델화 과정에 의해서도 얻어서, 이 값들이 3차원 입체조형치료시에 선량에 어떠한 영향을 끼치는지 팬톰 연구와 환자 연구를 통해서 평가하였다. 직접 측정한 경우 JTF는 6 MV의 경우에 0.001966, 10 MV의 경우에는 0.002971이었고, MLCTF는 6 MV의 경우에 0.01657, 10 MV의 경우에 0.01925이었다. 한편, 자동모델화 과정에 의해 얻은 경우, JTF는 6 MV의 경우에 0.001983, 10 MV의 경우에는 0.010431이었고, MLCTF는 6 MV의 경우에 0.00188, 10 MV의 경우에 0.00453이었다. JTF와 MLCTF의 경우에 직접 측정한 것은 자동모델화 과정에 의해 얻은 값과 큰 차이를 보였으나, 6 MV와 10 MV의 선질을 고려하면, 보다 합리적이었고, 이러한 값의 차이는 낮은 선량의 영역에서 선량에 영향을 미쳤다. JTF와 MLCTF의 잘못된 값은 선량의 오차를 다소 발생시킬 수도 있기 때문에, JTF와 MLCTF를 자동모델화과정에 의해서 얻은 값과 직접 측정하여 얻은 값을 비교하는 것은 빔커미셔닝 단계에서 도움이 될 것이다.

  • PDF

세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance) (Quality Assurance for Intensity Modulated Radiation Therapy)

  • 조병철;박석원;오도훈;배훈식
    • Radiation Oncology Journal
    • /
    • 제19권3호
    • /
    • pp.275-286
    • /
    • 2001
  • 목적 : 세기조절방사선치료의 임상적용을 위한 정도보증 절차를 확립하고, 실제 치료환자 1례에 대한 적용 과정을 보고하고자 한다. 대상 및 방법 : 본원에서는 세기조절방사선치료를 시행하기 위해 역방향 치료계획(inverse planning) 시스템으로 $P^3IMRT$ (ADAC, 미국)와 다엽콜리메이터(Multileaf collimator, MLC)가 부착된 방사선치료용 선형가속기 Primus (Siemens, 미국)를 사용하였다. 먼저 다엽콜리메이터에 대한 위치의 정확성, 재현성, leaf transmission factor를 측정하였다. 또한 소조사면에 대한 치료계획시스템의 commissioning을 실시하였다. 이를 이용하여 C자 형태의 가상 PTV (Planning Target Volume)에 대해 9개의 빔을 사용하여 세기변조 조사빔을 설계하여, 이를 팬톰 내에서 절대선량 및 상대선량을 측정하여 비교, 분석하였다. 실제 6개의 세기변조 조사빔을 사용하여 치료를 시행한 전립선암 환자를 대상으로, 팬톰내에서 재 계산된 선량계산 결과를 0.015 cc 미소전리함, 다이오드선량계(Scanditronix, 스웨덴), 필름 선량계, 그리고 선형배열다중검출기(array detector) 등을 사용하여 절대선량 및 상대선량을 평가하였다. 결과 : MLC 위치 정확도는 1 mm 이내이었으며, 재현성은 0.5 mm 내외로 평가되었고, leaf transmission 인자는 10MV 광자선에 대해서 interleaf leakage의 경우, $1.9\%$, midleaf leakage의 경우, $0.9\%$로 측정되었다. 필름, 다이오드선량계, 미소전리함, 물팬톰용 전리함(0.125 cc) 등의 반음영을 측정해 본 결과, 물팬톰용 전리함으로 측정된 반음영 영역$(80\~20\%)$은 필름에 비해 2 mm 가량 크며, 최소 beamlet 크기가 5 mm 임을 감안할 때 부적합한 것으로 판명되었다. RTP commissioning 후 계산 선량은 $1\times1\;cm^2$ 크기 소조사면에서의 측정치와 $2\%$ 범위 내에서 일치하였다. C자 형태의 PTV에 대한 9개의 세기변조된 조사빔에 대한 2회에 걸친 치료중심점에서의 절대선량 측정결과 개별 조사빔에 대하여는 $10\%$ 이상 차이를 보였으나 총 선량은 $2\%$ 이내에서 일치하였다. 필름을 이용한 선량분포도도 계산치와 비교적 잘 일치하였다. 실제 치료환자의 팬톰 내에서의 절대선량 측정 결과 총 선량은 $1.5\%$ 차이를 보였다. 각 조사빔에 대해 중심 leaf의 측방선량분포도를 필름 및 선형배열다중검출기를 사용하여 측정하였으며, 조사면 밖에서 계산선량이 $2\%$ 내외로 작게 나타났으나, 특정 위치를 제외하고는 $3\%$ 이내로 잘 일치함을 확인하였다. 결론 : 세기조절방사선치료를 위해서는 다엽콜리메이터의 위치에 대한 보다 정밀한 정도관리 절차가 개발되어야 될 것으로 판단되며, 조사빔내 세기패턴을 효율적으로 확인할 수 있는 정도보증 절차가 필요할 것으로 사료된다. 본원에서는 팬톰 내에서의 치료중심점과 같이 특정 지점에서의 절대선량 확인 및 필름 혹은 선형배열다중검출기를 사용한 세기분포 패턴의 확인 과정을 통하여, 이를 적절히 병행하여 사용함으로써 세기조절방사선치료에 적합한 정도관리를 시행할 수 있었다.

  • PDF