• Title/Summary/Keyword: Photo Diode

Search Result 256, Processing Time 0.026 seconds

A Study on the Computerized X-ray System (디지탈 X-선 촬영 시스템에 관한 연구)

  • 민병구;박광석
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.45-52
    • /
    • 1986
  • A digital X-ray system was developed using photo-diode arrays. Images were collected with 1,024x1,024x10 bit resolution and 0.5 sec acquisition time. An4 collected images were processed and restored using computer algorithms. For the normal and the patient, we obtained the digital X-ray images using the developed system.

  • PDF

2.2 “ QVGA LTPS LCD Panel integrated with Ambient light Sensor

  • Weng, Chien-Sen;Chao, Chih-Wei;Tseng, Hung Wei;Peng, Chia-Tien;Lin, Kun-Chih;Gan, Feng-Yuan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1319-1322
    • /
    • 2007
  • Planar PIN photodiode is compatible with LTPS process, and its fabrication requires no additional manufacturing process. In this study we design the optimum dimension of PIN diodes with two nitride layers to improve the efficiency of PIN diodes. The PIN photo sensor shows very good sensitivity to ambient light illuminance.

  • PDF

Design of Degradation Test without Replacement Based on Tightened Critical Value (엄격한 고장판정기준을 적용한 비복원 열화시험 설계에 관한 연구)

  • Park Boo Hee;Lim Ho Kyung;Jang Joong Soon
    • Journal of Applied Reliability
    • /
    • v.5 no.1
    • /
    • pp.167-180
    • /
    • 2005
  • Design of a degradation test without replacement is considered based on tightened critical value to reduce the evaluation testing time. The sample size, number of inspections, and the critical values are determined to assure the same probability of acceptance when the testing time is reduced to some degree. Photo-diode balance of an optical pickup is analyzed as a case study.

  • PDF

Power supply for the enhancement of dynamic range of APD (APD의 다이나믹 레인지 향상을 위한 전력 공급기)

  • ;;Boris Fursa
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.160-161
    • /
    • 2001
  • APD(avalanche photo diode)는 수광된 빛에 의해 생성된 캐리어를 강한 역바이어스 전압(40 ~ 400V)으로 가속시켜 avalanche 증배를 일으켜 큰 current를 얻을 수 있도록 제작된 소자이다. APD는 P-N 포토 다이오드에 비하여 수십~수백배의 높은 반응도(responsivity)를 얻을 수 있으며 응답 시간이 매우 짧다는 장점이 있는 반면 불규칙한 전류에 의해 만들어지는 내부 잡음 레벨이 높으며 온도에 민감하다는 단점을 갖고 있다. (중략)

  • PDF

A Study on the Promotion of Indirect Light Receiving Efficiency (간접 전파광의 수광 효율 향상에 관한 연구)

  • 허수진;정찬수
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.201-208
    • /
    • 1992
  • In the indirect optical bio-telemetry, high frequency response and low minimum detectable optical power can be achieved by using photodiode with small light receiving area which minimizes junction capacitance. But, on the other hand, S/N ratio becomes low because the optical signal current is small. To solve such a problem, we attach plato-convex lens in front of photo diode, The results of comput- er simulation and experiments suggest promotion of light receiving efficiency and possibility of multi- telemetry system through directivity of convex lens in one room.

  • PDF

EVALUATION OF NON-INVASIVE BLOOD GLUCOSE MEASUREMENT USING THREE TYPES OF NEAR INFRARED SPECTROMETER

  • Baek, Ju-Hyun;Kang, Na-Roo;Woo, Young-Ah;Kim, Hyo-Jin
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.289.1-289.1
    • /
    • 2003
  • Three types of near infrared spectrometer, a photo diode array type, a dispersive type and a FT type, were evaluated and compared the systematic difference in blood glucose measurement. The fundamental study was performed by adding glucose to buffer solution and bovine blood as the preceding study of non-invasive blood glucose. Spectra were collected using a 1.0 mm optical pathlength quartz cell by transmittance method. (omitted)

  • PDF

Measurement of human skin moisture in the near infrared region from 1100 nm to 2200 nm by using a portable system

  • Suh, Eun-Jung;Ahn, Jhii-Weon;Woo, Young-Ah;Kim, Hyo-Jin
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.290.2-290.2
    • /
    • 2003
  • Skin Moisture is an important factor in skin health. Measurement of moisture content can provide diagnostic information on the condition of skin. In this study, a photo diode array type near infrared spectroscopy was used to determine skin moisture. Diffuse reflectance spectra were collected and transformed to absorbance using 1-nm stepsize over the wavelength range of 1100 nm to 2200 nm. (omitted)

  • PDF

The Analysis of Effects of LED Panel Position and Lighting Angle on Communication Channel Quality in Indoor Visible Light Communication Systems (살내 가시광 무선 통신 시스템에서 LED 패널 위치 및 발광 각도가 통신 채널 품질에 미치는 영향 분석)

  • Do, Tronghop;Hwang, Jun-Ho;Yoo, Myung-Sik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.9B
    • /
    • pp.1108-1116
    • /
    • 2011
  • The visible light communication system that transmits data by controlling light emission of LED and receives data through photo detecter is considered as one of the strong candidates of the next generation wireless communication systems. The visible light communication provides both lighting and wireless communication wherever the LED lamps are installed. Due to the feature of visible light communication system, the communication is possible within the area that LED light reaches, and the communication quality depends on the light intensity received at the receiver. In this paper, we analyze the effects of LED panel position and lighting angel on communication channel quality in visible light communication systems. Through computer simulations, we prove that position of LED panel and light angle have a great impact on illuminance and SNR of the visible light communication systems.

Estimation Algorithm of Receiver's Position and Angle Based on Tracking of Received Light Intensity for Indoor Visible Light Communication Systems (실내 가시광 무선 통신 시스템의 수신 광도 변화 추적 기반 단말기 위치 및 수신각 추정 알고리즘)

  • Hwang, Jun-Ho;Lee, Ji-Soo;Yoo, Myung-Sik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.3
    • /
    • pp.60-67
    • /
    • 2011
  • Visible light communication system transmits data by controlling light emission of LED and receives data through photo detecter, which is considered as one of strong candidates of next generation wireless communication systems. The transmission capacity of visible light communication system depends on light intensity emitted from LED, sensitivity of PD, distance between transmitter and receiver, angle of incidence at the receiver. In particular, the receiver's vertical and horizontal movement changes distance between transmitter and receiver and angle of incidence, which may degrades transmission capacity of system. In this paper, we propose an estimation algorithm of receiver's position and angle based on tracking of received light intensity for indoor visible light communication systems. The performance evaluation of proposed algorithm confirms that the estimation algorithm of receiver's position and angle is quite important for visible light communication system to improve its transmission capacity.

Measuring System for Impact Point of Arrow using Mamdani Fuzzy Inference System (Mamdani 퍼지추론을 이용한 화살의 탄착점 측정 시스템)

  • Yu, Jung-Won;Lee, Han-Soo;Jeong, Yeong-Sang;Kim, Sung-Shin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.521-526
    • /
    • 2012
  • The performance of arrow from a manufacturing process depends on arrow's trajectory(archer's paradox) and intensity of an impact points. Especially, when conducting a shooting experiment over and over in the same experiment condition, the intensity of impact point is an objective standard to judge the performance of the arrow. However, the analysis method for the impact point is not enough, a previous research of the arrow's performance has been focused on a skill to optimize a manufacturing variables(feathers of an arrow, barb of an arrow, arrow's shaft, weight, external diameter, spine). In this paper, We propose measurement system of arrow's impact point with Mamdani fuzzy inference system and similarity of polygon for automation of impact point's measurement. Measuring the impact point data of the arrow moving with a high speed(approximately 275km/h) by using line laser and photo diode array, then the measured data are mapped to arrow's impact point with fuzzy inference and similarity of polygon.