• Title/Summary/Keyword: Phase variation

Search Result 2,038, Processing Time 0.024 seconds

Microwave Wideband Constant Phase Shifter (마이크로파 광대역 정위상기)

  • Bae, Jung-Yi
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.2
    • /
    • pp.182-188
    • /
    • 1986
  • A method of wideband constant phase control is proposed. This can be applied to reflection type phase shifter with p-i-n diode. Using the proposed method, a microwave phase network which consists of a transmission line and reactive circuit element is suggested. By determining theproper values of design parameters, the desired wideband constant phase with different specification can easily be designed. Also, using the proposed method, the parameters variation, and 1.1 dB of insertion loss in the range of 12% bandwidth.

  • PDF

Design of Vector Attenuator (벡터 감쇠기의 설계)

  • 정용채;장익수
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.11
    • /
    • pp.31-37
    • /
    • 1998
  • Magnitude/phase controlling circuit which is composed of attenuator and phase shifter make phase/gain cross-coupling, so too much tuning time is needed to find optimum operation point. In this paper, vector attenuator which control magnitude and phase of input signals is proposed. Vector attenuator in past ignores phase variation characteristics of attenuator, but vector attenuator of this paper compensates phase variation characteristics of attenuator. This vector attenuator consists of 0$^{\circ}$/180$^{\circ}$ phase shifter and low phase shifting attenuator and so forth. A 0$^{\circ}$/180$^{\circ}$ phase shifter has 0$^{\circ}$/179.9$^{\circ}$ phase shifting characteristics at a center frequency 881 MHz and a low phase shifting attenuator has an attenuation of 25dB, within the limit of 3.6$^{\circ}$ phase shift and less than -20dB reflection characteristics at both input and output ports. The designed vector attenuator shows that cartesian coordinate plane of output signal space can be represented correctly.

  • PDF

Design of a RF fixed phase control circuit using I&Q Demodulator (I&Q Demodulator를 이용한 RF 고정 위상 제어기 설계)

  • Park, Ung-Hee;Chang, Ik-Soo;Huh, Jun-Won;Gang, In-Ho
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.1
    • /
    • pp.8-14
    • /
    • 1999
  • The active devices used at microwave frequency have the different phase shift according to input power. Especially, The difference of the phase shift is large in the saturation region of the amplifier. In this paper, we disigned the phase control system for fixing the different phase shift at device. With the high frequency nonlinear amplifier, we fabricated such system that the phase shift to be fixed automatically using the varible phase shifter. The variable phase shifter fixed total phase variation of the circuit using the information that was obtained from the comparison of imputsignal phase with output signal phase. Even though the input signal is 2-tone or FM type, we could estimate and also fix the phase variation on DUT Dynamic range is about 10dB. It has been experimented at 1960MHz using Teflon (H=31mil, ${\varepsilon}r$=3.2)

  • PDF

Analysis of Quench Generation in Fault Types According to Inductance Variation in Integrated Three-Phase Flux-Lock Type Superconducting Fault Current Limiting (삼상일체화된 자속구속형 고온초전도 전류제한기의 인덕턴스 변화에 따른 사고유형별 퀜치발생 분석)

  • Park, Chung-Ryul;Lim, Sung-Hun;Park, Hyoung-Min;Cho, Yong-Sun;Choi, Hyo-Sang;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.165-166
    • /
    • 2005
  • In this paper, we investigated the quench generation of HTSC elements in fault types according to inductance variation in the integrated three-phase flux-lock type SFCL. The integrated three-phase flux-lock type SFCL was the upgrade version of the single-phase flux-lock type SFCL. The structure of the integrated three-phase flux-lock type SFCL consisted of three-phase flux-lock reactor wound on an iron core with the ratio of the same turn between coil 1 and coil 2 in each phase. When the SFCL is operated under the normal condition, the flux generated in the iron core is zero because the flux generated between two coils of each single phase is canceled out. Therefore, the SFCL's impedance is zero, and the SFCL has negligible influence on the power system. However, if a fault occurs in any single-phase among three phases, the flux generated in the iron core is not zero any more. The flux makes HTSC elements of all phases quench irrespective of the fault type, which reduces the current of fault phase as well as the current of sound phase. It was observed that the fault current limiting characteristics of the suggested SFCL were dependent on the quench characteristics of HTSC elements in all three phases.

  • PDF

A Study on the Characteristics Improvement of Fluid Power Actuator Using Adaptive Control (적응제어를 이용한 유압 액츄에이터의 특성개선에 관한 연구)

  • 염만오;윤일로
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.1
    • /
    • pp.124-132
    • /
    • 2004
  • A hydraulic system is difficult to keep the performance due to non-linearity, load pressure which changes according to working condition and system parameter variation, the requirement of control algorithm has been risen in order to satisfy them. An adaptive control is a control method which is suggested to achieve a control object though plant characteristics change. In spite of the case that plant characteristics and the degree of variation are difficult to grasp, adaptive control can keep the characteristics of closed-loop system regularly. In this study GMVAC(generalized minimum variance adaptive control) combined with output error feedback is proposed in order to solve problems of non-minimum phase, vibration and overshoot in initial response of the plant. The control performance according to the variation of characteristics of the plant is evaluated by changing the supply pressure only.

Dynamic Analysis of a 3-Phase BLDC Motor Considering Variation of an Air-Gap (공극의 시간변화를 고려한 3 상 BLDC 모터의 동특성 해석)

  • Park, Ki-Sun;Im, Hyung-Bin;Chung, Jin-Tai
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.10
    • /
    • pp.1038-1044
    • /
    • 2009
  • In this study, vibrations of an electric motor are analyzed when the motor has the interaction between mechanical and electromagnetic behaviors. For this vibration analysis a 3-phase 8-pole brushless DC motor is selected. Vibrations of the motor are influenced by coupled electromechanical characteristics. The variation of air-gap induced by vibration has an influence on the inductance of the motor coil. To analyze dynamic characteristics of the rotor, we studied inductance by the variation of an air-gap. After obtaining the kinetic, potential and magnetic energies for the motor, the equations of motion are derived by using Lagrange's equation. By applying the Newmark time integration method to the equations, the dynamic responses for the displacements and currents are computed.

Quantitative Assessment of Variation in Poroelastic Properties of Composite Materials Using Micromechanical RVE Models

  • Han, Su Yeon;Kim, Sung Jun;Shin, Eui Sup
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.2
    • /
    • pp.175-183
    • /
    • 2016
  • A poroelastic composite material, containing different material phases and filled with fluids, serves as a model to formulate the overall ablative behaviors of such materials. This article deals with the assessment of variation in nondeterministic poroelastic properties of two-phase composite materials using micromechanical representative volume element (RVE) models. Considering the configuration and arrangement of pores in a matrix phase, various RVEs are modeled and analyzed according to their porosity. In order to quantitatively investigate the effects of microstructure, changes in effective elastic moduli and poroelastic parameters are measured via finite element (FE) analysis. The poroelastic parameters are calculated from the effective elastic moduli and the pore-pressure-induced strains. The reliability of the numerical results is verified through image-based FE models with the actual shape of pores in carbon-phenolic ablative materials. Additionally, the variation of strain energy density is measured, which can possibly be used to evaluate microstress concentrations.

Changes of Spatial Composition by Project Phase of Homebase and Media-space on Variation Type Middle and High Schools (교과교실제 중등학교 홈베이스와 미디어스페이스의 사업단계별 공간구성 변화)

  • Park, Im-Ho;Jung, Jin-Ju
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.21 no.2
    • /
    • pp.13-24
    • /
    • 2014
  • This study compared and analyzed middle and high school's homebase and media space which are installed along with the introduction of subject classroom system operation method, with regard to the position of arrangement, the type of arrangement, and the change of area, etc. which were changed and applied per the phase of project. For this, design competitions were implemented since 2006 targeting the cases which participated in design directly-indirectly in the researcher's architectural firm, present construction documents among the selected BTL(Build-Transfer-Lease) were completed, and the examples of 10 schools(design competitions 2 schools, BTL selected plans 8 schools) were analyzed, which were operating variation type.

A new approach to calculation of running characteristics of a split phase type single phase induction motor (분상형 단상유도전동기의 특성계산의 신방안)

  • 원종수
    • 전기의세계
    • /
    • v.17 no.1
    • /
    • pp.21-31
    • /
    • 1968
  • The variation of the voltage has been known to be harmful in the sound operation of motors. It also results in the variation in slip. If the voltage and slip are known, every characteristics of motors can be determined. This paper, therefore, analyzed numerically the characteristics of motors by the formula expressed in the function of both slip and voltage, and then satisfactorily compared with the experimental values. A new per-unit method derived in this paper is shown to be easier and simpler than the conventnional one in determining the relative running characteristics. It has also suggested the minimum allowable voltage when voltage below the rated value was applied to the motor. It is expected to apply to the determination of the characteristics under the voltage variation.

  • PDF

The Effect of Header and Channel Angle Variation on Two-Phase Flow Distribution at Multiple Junctions (헤더-채널 분기관의 각도변화가 2상 유동 분배에 미치는 영향에 대한 연구)

  • Lee, Jun Kyoung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.11
    • /
    • pp.559-566
    • /
    • 2015
  • The main objective of this work is to experimentally investigate the effect of angle variation on the distribution of two-phase flow at header-channel junctions. The cross-sections of the header and the channels were fixed at $16mm{\times}16mm$ and $12mm{\times}1.8mm$, respectively. Air and water were used as the test fluids. Four different header-channel positions were tested : Vertical header with Horizontal channels (case VM-HC), Horizontal header with Horizontal channels (case HM-HC), Horizontal header with Vertical Downward channels (case HM-VDC), and Horizontal header with Vertical Upward channels (case HM-VUC). In all cases, liquid flow distribution tended to decrease gradually in the upstream header region. However, in the downstream region, different trends could be seen. The reason for these different tendencies were identified by flow visualization in each case. The standard deviations for the liquid and gas flow distribution in each case were calculated, and the case of VM-HC had the lowest values compared to other cases because of the symmetrically distributed liquid film and strong flow recirculation near the end plate.