• Title/Summary/Keyword: Phase variation

Search Result 2,038, Processing Time 0.027 seconds

Temporal and Spatial Variations in Sea Surface Temperature Around Boryeong off the West Coast of Korea From 2011-2012 (2011-2012년 서해 보령연안 수온의 시공간적 변동)

  • Choo, Hyo-Sang;Yoon, Eun-Chan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.5
    • /
    • pp.497-512
    • /
    • 2017
  • Temporal and spatial variations in surface water temperature were studied using data from temperature monitoring buoys deployed at 47 stations around Boryeong from 2011-2012 off the west coast of Korea. Temperature fluctuations are predominant at diurnal and semidiurnal periods for all seasons, and their amplitudes are large in spring and summer but small in autumn. The maximum annual change in air temperature takes place on August 2nd and August 22th for water temperature, which means the phase for air temperature precedes water temperature by 20 days. The diurnal period of water temperature fluctuation is predominant around Daecheon and Muchangpo Harbors, with the semidiurnal period around Wonsan Island, and the shallow water constituent period on the estuary around Daecheon River. On the whole, air and water temperatures fluctuate with wind. Spectral analyses of temperature records show significant peaks at the 0.5, 1 and 15 day marks with 7-10 day periods of predominant fluctuations. Cross-correlation analyses for the temperature fluctuation show that the waters around Boryeong can be classified into four areas: a mixed water zone around the southeast side of Wonsan Island, an off-shore area to the west, an off-shore area to the south and a coastal area along the shore from Song Island to Muchangpo Harbor.

Establishment of Analytical Method for Pymetrozine Residues in Crops Using Liquid-Liquid Extraction(LLE) (액-액 분배법을 활용한 작물 중 pymetrozine의 잔류분석법 확립)

  • Yoon, Ji-Young;Moon, Hye-Ree;Park, Jae-Hun;Han, Ye-Hoon;Lee, Kyu-Seung
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.2
    • /
    • pp.107-116
    • /
    • 2013
  • Polar pesticides like pymetrozine (log $P_{ow}$: -0.18) are known to be difficult to analyze. The analytical method of pymetrozine using hydromatrix included in the official method of KFDA was uncommon and provided ambiguous evidence to confirm both the identity and the quantity. Therefore, precise single residue analytical method was developed in representative crops for using liquid-liquid extraction (LLE). The pymetrozine residue was extracted with methanol from 11 representative crops which comprised apple, blueberry, broccoli, cabbage, cherry, crown daisy, hulled rice, Korean cabbage, potato, rice and watermelon. The extract was purified serially by liquid-liquid extraction (LLE) and silica solid phase extraction (SPE). For rice and hulled rice samples, n-hexane partition was additionally adopted to remove nonpolar interferences, mainly lipids. The residue levels were analyzed by HPLC with DAD, using $C_8$ column. LOQ (limit of quantitation) of pymetroizinie was 1 ng (S/N > 10) and MQL (method quantitation limit) was 0.01 mg/kg. Mean recoveries from 11 crop samples fortified at three levels (MQL, 10 ${\times}$ MQL and 50 ${\times}$ MQL) in triplicate were in the range of 83.1~98.5% with coefficients of variation (CV) of less than 10%, regardless of sample type, which satisfies the criteria of KFDA. The method established in this study could be applied to most of crops as an official and general method for analysis of pymetrozine residue.

Determining the Rotation Periods of an Inactive LEO Satellite and the First Korean Space Debris on GEO, KOREASAT 1

  • Choi, Jin;Jo, Jung Hyun;Kim, Myung-Jin;Roh, Dong-Goo;Park, Sun-Youp;Lee, Hee-Jae;Park, Maru;Choi, Young-Jun;Yim, Hong-Suh;Bae, Young-Ho;Park, Young-Sik;Cho, Sungki;Moon, Hong-Kyu;Choi, Eun-Jung;Jang, Hyun-Jung;Park, Jang-Hyun
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.2
    • /
    • pp.127-135
    • /
    • 2016
  • Inactive space objects are usually rotating and tumbling as a result of internal or external forces. KOREASAT 1 has been inactive since 2005, and its drift trajectory has been monitored with the optical wide-field patrol network (OWL-Net). However, a quantitative analysis of KOREASAT 1 in regard to the attitude evolution has never been performed. Here, two optical tracking systems were used to acquire raw measurements to analyze the rotation period of two inactive satellites. During the optical campaign in 2013, KOREASAT 1 was observed by a 0.6 m class optical telescope operated by the Korea Astronomy and Space Science Institute (KASI). The rotation period of KOREASAT 1 was analyzed with the light curves from the photometry results. The rotation periods of the low Earth orbit (LEO) satellite ASTRO-H after break-up were detected by OWL-Net on April 7, 2016. We analyzed the magnitude variation of each satellite by differential photometry and made comparisons with the star catalog. The illumination effect caused by the phase angle between the Sun and the target satellite was corrected with the system tool kit (STK) and two line element (TLE) technique. Finally, we determined the rotation period of two inactive satellites on LEO and geostationary Earth orbit (GEO) with light curves from the photometry. The main rotation periods were determined to be 5.2 sec for ASTRO-H and 74 sec for KOREASAT 1.

Analytical Method of Bentazone Residue in Agricultural Commodities Using HPLC-UVD/MS (HPLC-UVD/MS를 이용한 농산물 중 bentazone의 분석법 확립)

  • Kim, Young-Hak;Lee, Su-Jin;Song, Lee-Seul;Hwang, Young-Sun;Lee, Young-Deuk;Choung, Myoung-Gun
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.2
    • /
    • pp.149-159
    • /
    • 2011
  • Bentazone is benzothiadiazole group herbicide, and used to foliage treatment. This herbicide have already been widely used for cereals and vegetables planting in worldwide. This experiment was conducted to establish a determination method for bentazone residue in crops using HPLC-UVD/MS. Bentazone residue was extracted with acetone (adjusted pH 1 with phosphoric acid) from representative samples of five raw products which comprised hulled rice, soybean, apple, green pepper, and Chinese cabbage. The extract was diluted with saline water, and dichloromethane partition was followed to recover bentazone from the aqueous phase. Florisil column chromatography was additionally employed for final clean up of the extract. The bentazone was quantitated by HPLC with UVD, using a YMC ODS AM 303 ($4.6{\times}250$ mm) column. The crops were fortified with bentazone at 3 levels per crop. Mean recovery ratio were ranged from 82.0% for a 0.2 mg/kg in apple to 97.9% for a 0.02 mg/kg in Chinese cabbage. The coefficients of variation were ranged from 0.5% for a 0.02 mg/kg in soybean to 9.7% for a 0.02 mg/kg in Chinese cabbage. Quantitative limit of bentazone was 0.02 mg/kg in representative five crop samples. A LC/MS with selected-ion monitoring was also provided to confirm the suspected residue. Therefore, this analytical method was reproducible and sensitive enough to determine the residue of bentazone in agricultural commodities.

Determination of Ametryn Residue in Agricultural Commodities Using HPLC-UVD/MS (HPLC-UVD/MS를 이용한 농산물 중 ametryn의 분석)

  • Lee, Su-Jin;Kim, Young-Hak;Song, Lee-Seul;Choung, Myoung-Gun
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.2
    • /
    • pp.125-133
    • /
    • 2011
  • Ametryn is used in USA, China, and Japan, but not introduced in Korea yet. So, MRL (Maximum Residue Level), and analytical method of ametryn were not establishment in Korea. Therefore, this experiment was conducted to establish a determination method for ametryn residue in crops using HPLC-UVD/MS. Ametryn residue was extracted with acetone from representative samples of five raw products which comprised hulled rice, soybean, apple, green pepper, and Chinese cabbage. The extract was diluted with saline water, and dichloromethane partition was followed to recover ametryn from the aqueous phase. Florisil column chromatography was additionally employed for final clean up of the extract. The ametryn was quantitated by HPLC with UVD, using a Tosoh ODS 120T ($4.6{\times}250$ mm) column. The crops were fortified with ametryn at 2 levels per crop. Mean recovery ratio were ranged from 83.7% for a 0.2 mg/kg in soybean to 91.1% for a 1.0 mg/kg in hulled rice. The coefficients of variation were ranged from 1.2% for a 1.0 mg/kg in hulled rice to 3.6% for a 1.0 mg/kg in soybean. Quantitative limit of amatryn was 0.02 mg/kg in representative 5 crop samples. A LC/MS with selected-ion monitoring was also provided to confirm the suspected residue. Therefore, this analytical method was reproducible and sensitive enough to determine the residue of ametryne in agricultural commodities.

Development and validation of an LC-MS/MS method for determination of compound K in human plasma and clinical application

  • Kim, Jung Soo;Kim, Yunjeong;Han, Song-Hee;Jeon, Ji-Young;Hwang, Minho;Im, Yong-Jin;Kim, Jung Hyun;Lee, Sun Young;Chae, Soo-Wan;Kim, Min-Gul
    • Journal of Ginseng Research
    • /
    • v.37 no.1
    • /
    • pp.135-141
    • /
    • 2013
  • A rapid, sensitive and selective analytical method was developed and validated for the determination of compound K, a major intestinal bacterial metabolite of ginsenosides in human plasma. Liquid-liquid extraction was used for sample preparation and analysis, followed by liquid chromatography tandem spectrometric analysis and an electrospray-ionization interface. Compound K was analyzed on a Phenomenex Luna C18 column ($100{\times}2.00$ mm, 3 ${\mu}m$) with the mobile phase run isocratically with 10 mM ammonium acetate-methanol-acetonitrile (5:47.5:47.5, v/v/v) at a flow rate of 0.5 mL/min. The method was validated for accuracy (relative error <12.63%), precision (coefficient of variation <9.14%), linearity, and recovery. The assay was linear over the entire range of calibration standards i.e., a concentration range of 1 ng/mL to 1,000 ng/mL ($r^2$ >0.9968). The recoveries of compound K after liquid-liquid extraction at 1, 2, 400, and 800 ng/mL were $106.00{\pm}0.08%$, $103.50{\pm}0.19%$, $111.45{\pm}5.21%$, and $89.62{\pm}34.46%$ for intra-day and $85.40{\pm}0.08%$, $94.50{\pm}0.09%$, $112.50{\pm}5.21%$, and $95.87{\pm}34.46%$ for inter-day, respectively. The lower limit of quantification of the analytical method of compound K was 1 ng/mL in human plasma. The developed method was successfully applied to a pharmacokinetic study of compound K after oral administration in ten of healthy human subjects.

Design and Performance Evaluation of ACA-TCP to Improve Performance of Congestion Control in Broadband Networks (광대역 네트워크에서의 혼잡 제어 성능 개선을 위한 ACA-TCP 설계 및 성능 분석)

  • Na, Sang-Wan;Park, Tae-Joon;Lee, Jae-Yong;Kim, Byung-Chul
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.10 s.352
    • /
    • pp.8-17
    • /
    • 2006
  • Recently, the high-speed Internet users increase rapidly and broadband networks have been widely deployed. However, the current TCP congestion control algorithm was designed for relatively narrowband network environments, and thus its performance is inefficient for traffic transport in broadband networks. To remedy this problem, the TCP having an enhanced congestion control algorithm is required for broadband networks. In this paper, we propose an improved TCP congestion control that can sufficiently utilize the large available bandwidth in broadband networks. The proposed algorithm predicts the available bandwidth by using ACK information and RTT variation, and prevents large packet losses by adjusting congestion window size appropriately. Also, it can rapidly utilize the large available bandwidth by enhancing the legacy TCP algorithm in congestion avoidance phase. In order to evaluate the performance of the proposed algorithm, we use the ns-2 simulator. The simulation results show that the proposed algorithm improves not only the utilization of the available bandwidth but also RTT fairness and the fairness between contending TCP flows better than the HSTCP in high bandwidth delay product network environment.

Simultaneous Determination of B Group Vitamins in Supplemented Food Products by High Performance Liquid Chromatography-Diode Array Detection

  • Suh, Joon-Hyuk;Yang, Dong-Hyug;Lee, Byung-Kyu;Eom, Han-Young;Kim, Un-Yong;Kim, Jung-Hyun;Lee, Hye-Yeon;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2648-2656
    • /
    • 2011
  • A simple HPLC-DAD method was developed and validated to determine B group vitamin content (thiamine, riboflavin, nicotinamide, pantothenic acid, pyridoxine and folic acid) in supplemented food samples, i.e., infant formula, cereal, low-calorie food, a multi-vitamin pill and a vitamin drink. In this study, the most significant advantages were simultaneous determination of the six B group vitamins in various food matrices and a small number of sample treatment steps that required only an organic solvent, acetonitrile. Moreover, this method prevents reduction of column durability, because the mobile phase does not contain ion-pairing reagents. Analytes were separated on a Develosil RPAQUEOUS $C_{30}$ (4.6 mm ${\times}$ 250 mm, 5 ${\mu}M$ particle size) column with a gradient elution of acetonitrile and 20 mM phosphate buffer (pH 3.0) at a flow rate between 0.8 and 1.0 mL/min. Detection was performed at 275 nm, except for that of pantothenic acid (205 nm). The calibration curves for all six vitamins showed good linearity with correlation coefficients ($r^2$) higher than 0.995. The developed method was validated with respect to linearity, intra- and inter-day accuracy and precision, limit of quantification (LOQ), recovery and stability. The method showed good precision and accuracy, with intra- and inter-assay coefficients of variation less than 15% at all concentrations. The recovery was carried out according to the standard addition procedure, with yields ranging from 89.8 to 104.4%. This method was successfully applied to the determination of vitamin B groups in supplemented food products.

Effect of Surface Treatment on Hydrogen Production of Cadmium Sulfide Particulate Film Electrodes (수소제조용 CdS 입자막 전극의 표면처리 효과)

  • Jang, Jum-Suk;Chang, Hye-Young;So, Won-Wook;Rhee, Young-Woo;Moon, Sang-Jin
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.11 no.3
    • /
    • pp.119-125
    • /
    • 2000
  • To improve the photochemical energy conversion efficiency and the stability of CdS particulate film electrode which is used to produce hydrogen from the aqueous $H_2S$ solution photoelectrochemically, surface treatment of this film was carried out using $TiCl_4$ solution. CdS particles for preparation of the films were synthesized by precipitation reaction of $Cd({NO_3})_2{\cdot}9H_2O$ and $Na_2S{\cdot}4H_2O$. Then, the CdS sol was hydrothermally treated for 12hr in an autoclave with the variation of treatment temperature to control the crystalline phase of particles. CdS film electrode was thus prepared by annealing at $400^{\circ}C$ for 12hr of the wet-film cast at room temperature, and subsequently surface treated with $TiCl_4$ solution. The electrodes were characterized using XRD, SEM, and the photocurrent meter. The photocurrents of Cds film electrodes prepared with surface treatment were up to two times higher than the electrodes without surface treatment, indicating about $4.0mA/cm^2$. Hydrogen production rate in a continuous flow system using photoelectrochemical or photochemical cells prepared with surface treatment also increased in proportion to the increase of photocurrents.

  • PDF

Input Balun Design Method for CMOS Differential LNA (차동 저 잡음 증폭기의 입력 발룬 설계 최적화 기법)

  • Yoon, Jae-Hyuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.5
    • /
    • pp.366-372
    • /
    • 2017
  • In this paper, the analysis of baluns that are inevitably required to design a differential low noise amplifier, The balun converts a single signal input from the antenna into a differential signal, which serves as an input to the differential amplifier. In addition, it protects the circuit from ESD(Electrostatic Discharge) coming through the antenna and helps with input matching. However, in the case of a passive balun used in general, since the AC signal is transmitted through electromagnetic coupling formed between two metal lines, it not only has loss without gain but also has the greatest influence on the total noise figure of the receiving end. Therefore, the design of a balun in a low-noise amplifier is very important, and it is important to design a balun in consideration of line width, line spacing, winding, radius, and layout symmetry that are necessary. In this paper, the factors to be considered for improving the quality factor of balun are summarized, and the tendency of variation of resistance, inductance, and capacitance of the balun according to design element change is analyzed. Based on the analysis results, it is proved that the design of input balun allows the design of low noise, high gain differential amplifier with gain of 24 dB and noise figure of 2.51 dB.