• Title/Summary/Keyword: Phase of Design

Search Result 6,241, Processing Time 0.036 seconds

Analysis and Design of a 3-phase Series-Resonant type High Voltage Capacitor Charger (3상 직렬공진형 고전압 커패시터 충전기의 해석 및 설계)

  • Lee, Byungha;Park, Sangeun;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.510-516
    • /
    • 2013
  • This paper suggests a 3-phase series-resonant type high voltage capacitor charger for an EML pulsed power system. The operating principle on the charger is explained by an equivalent circuit. Additionally, we analyze the charging characteristic in one discontinuous conduction mode and three continuous conduction modes. The analysis shows that the resonant current per phase is two thirds of the 3-phase charger's average charging current and one third of the single-phase charger's average charging current with the same capacity. We suggest a design method of the 3-phase capacitor charger in each operational mode and present an example of 3.5 kW capacitor charger at ${\omega}_s=0.33{\omega}_r$. The 3.5 kW 3-phase capacitor charger prototype is assembled with a TI28335 controller and a 40 kJ, 7 kV capacitor. The design rules based on the analysis are verified by experiment.

Analysis and Design of the Interface Inductor and the DC Side Capacitor in a STATCOM with Phase and Amplitude Control Considering the Stability of the System

  • Zhao, Guopeng;Han, Minxiao;Liu, Jinjun
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.193-200
    • /
    • 2012
  • Previous publications regarding the design and specifications of the interface inductor and the DC side capacitor for a STATCOM usually deal with the interface inductor and the DC side capacitor only. They seldom pay attention to the influences of the interface inductor and capacitor on the performance of a STATCOM system. In this paper a detailed analysis of influence of the interface inductor and the DC side capacitor on a STATCOM system and the corresponding design considerations is presented. Phase and amplitude control is considered as the control strategy for the STATCOM. First, a model of a STATCOM system is carried out. Second, through frequency domain methods, such as transfer functions and Bode plots, the influence of the interface inductor and the DC side capacitor on the stability and filtering characteristics of the STATCOM are extensively investigated. Third, according to this analysis, the design considerations based on the phase margin for the interface inductor and the DC side capacitor are discussed, which leads to parameters that are different from those of the traditional design.

A study on Sinusoidal Phase Modulating interferometer using laser diode (레이저 다이오드를 이용한 정현적 위상변조 간섭계에 대한 연구)

  • Pyo K.Y.;Park N.G.;Lee G.Y.;Kang Y.J.;Kim K.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.926-929
    • /
    • 2005
  • Recently, laser interferometer is widely used as a measuring system in many fields because of its high resolution and its ability to measure a board area in real-time ail at once. In conventional laser interferometer, for examples Out of plane ESPI, In plane ESPI, Shearography and Holography, it uses PZT or other components as a phase shift instrumentation to extract 3-D deformation data, vibration mode and others. However, in most cases PZT has some disadvantages, which include noli-linear errors and limited time of use. In present study, a new type of laser interferometer using a laser diode(LD) is proposed. Using Laser Diode Sinusoidal Phase Modulating(LD-SPM) interferometer, the phase modulation can be directly modulated by controlling the LD injection current thereby eliminating the need for PZT components.

  • PDF

Digital Control Strategy for Single-phase Voltage-Doubler Boost Rectifiers

  • Cho, Young-Hoon;Mok, Hyung-Soo;Ji, Jun-Keun;Lai, Jih-Sheng
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.623-631
    • /
    • 2012
  • In this paper, a digital controller design procedure is presented for single-phase voltage-doubler boost rectifiers (VDBR). The model derivation of the single-phase VDBR is performed in the s-domain. After that the simplified equivalent z-domain models are derived. These z-domain models are utilized to design the input current and the output dc-link voltage controllers. For the controller design in the z-domain, the traditional K-factor method is modified by considering the nature of the digital controller. The frequency pre-warping and anti-windup techniques are adapted for the controller design. By using the proposed method, the phase margin and the control bandwidth are accurately achieved as required by controller designers in a practical frequency range. The proposed method is applied to a 2.5 kVA single-phase VDBR for Uninterruptible Power Supply (UPS) applications. From the simulation and the experimental results, the effectiveness of the proposed design method has been verified.

Nonlinear Control of an Automatic Transmission Using Sliding Mode (슬라이딩모드를 이용한 자동변속기의 비선형제어)

  • 조승호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.3
    • /
    • pp.605-614
    • /
    • 1995
  • In the automatic transmission using planetary gear there exists nonlinearities due to the finite difference between gear ratios, which yield torque hole during shift and influence on the ride quality and life of clutch. Based on the reaction carrier and converter turbine speed sliding functions are defined. Nonlinear closed-loop control laws are derived using them. Computer simulation shows that the closed loop design is better than the open loop design and semi-closed loop design.

A Design Study of Phase Detectors for the 2.5 Gb/s Clock and Data Recovery Circuit (2-5 Gb/s 클럭-데이터 복원기를 위한 위상 비교기 설계 연구)

  • 이영미;우동식;유상대;김강욱
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2002.11a
    • /
    • pp.394-397
    • /
    • 2002
  • A design study of phase detectors for the 2.5 Gb/s CDR circuit using a standard 0.18-${\mu}{\textrm}{m}$ CMOS process has been performed. The targeted CDR is based on the phase-locked loop and thus it consists of a phase detector, a charge pump, a LPF, and a VCO. For high frequency operation of 2.5 Gb/s, phase detector and charge pump, which accurately compare phase errors to reduce clock jitter, are critical for designing a reliable CDR circuit. As a phase detector, the Hogge phase detector is selected but two transistors are added to improve the performance of the D-F/F. The charge pump was also designed to be placed indirectly input and output.

  • PDF

Analysis and Design of LCL Filter with Passive Damping Circuits for Three-phase Grid-connected Inverters

  • Ahn, Hyo Min;Oh, Chang-Yeol;Sung, Won-Yong;Ahn, Jung-Hoon;Lee, Byoung Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.217-224
    • /
    • 2017
  • The analysis and design process of the LCL filter with passive damping circuits for three-phase grid-connected inverter are presented based on the generalized model of LCL filter. Several types of the passive damping circuits in previous studies could be compared and analyzed by using the generalized model considering various design criteria of passive damping circuits. According to the analysis in this paper, a reasonable configuration of passive damping circuits for three-phase grid-connected inverters is proposed. The validity of the proposed design process is verified by informative simulation and experimental results.

CHECKLIST FOR ENVIRONMENTAL FRIENDLY CONSTRUCTION MANAGEMENT IN DESIGN PHASE

  • In-Su Jung;Hyun-Su Park;Chan-Sik Lee
    • International conference on construction engineering and project management
    • /
    • 2007.03a
    • /
    • pp.376-385
    • /
    • 2007
  • Construction project is necessary element for human life to upgrade the quality and convenience. However, due to its contradictory nature to the environment preservation, environmental pollution and damage, deterioration of natural scenery, noise/vibration, water quality pollution, etc. caused in the process of construction greatly affect the environment. For the building or construction project, its possible impact on environment during construction work and after completion must be predicted at its design phase, which will result in the completion of the architecture convenient for human being with its environmental pollution reduced to minimum level. In this study, the checklist of environmental factors was suggested, which should be taken into account at its design phase in conducting the construction work. Proposed checklist was linked with the developed web-based system for the convenience of users like designer and construction manager, etc. It is expected that the checklist suggested by this study will help the designer and construction manager to continue the steady development from the environmental viewpoint during the design phase.

  • PDF

The Extraction for each Design phase using Environment-Friendly Design Factors by In-depth Evaluation of Experts in social housing (전문가집단 심층평가를 통한 사회주택 건축단계별 친환경적 계획요소 추출에 관한 연구)

  • Choi, Young-Oh;Choi, Moo-Hyuck
    • Journal of the Korean housing association
    • /
    • v.21 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • Housing problems in city have being caused social contradiction that contains social discord and conflict between poor and rich. And they have raised one of social problems including a disequilibrium of demand and supply, a housing trouble, and a poor residential environment. Therefore, the purpose of this study is to suggest to the improvement of social housing that exposes to a poor environment for social integration. For this, this study is to extract environmental-friendly design factors for each building phase by in-depth evaluation of experts, and to analyze the problems of domestic social housing and environment-friendly design factors considered prior literature. The results as follow. It might be considered highly phase of schematic design, The building construction, and performance management having factors. Specially, it analyzed to 'Living Environment', 'Economic Efficiency', and 'renewable Energy Systems' should be considered highly. Ultimately, this study would be reconsidered the improvement of social housing proposed by the Government for the social outcast.

The Study of Two Phase SRM with No-Flux Reversal in the Stator (고정자에서 자속의 교번이 없는 2상 SRM의 특성에 관한 연구)

  • Oh, Seok-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.31-33
    • /
    • 2007
  • Cost reduction requires lowering number of power devices used in the converter driving SRM. This is quite feasible in SRM drive systems than in other drive systems. This paper deals with design, analysis, and simulation of such a novel two phase SRM. A novel two phase SRM has high performance, self-starting capability, high efficiency, and low manufacturing cost. Additionally, the stator back iron does not experience any flux reversal as the flux is in the same direction whether phase A or B is excited leading to a greater reduction in core losses. The magnetic analysis and design considerations of the novel two phase SRM have been obtained by the finite element analysis (FEM). Experimental verification of the machine design is provided to correlate with analysis and simulation studies.

  • PDF