• 제목/요약/키워드: Phase degree

검색결과 1,165건 처리시간 0.029초

UV-Induced Graft Polymerization of Polypropylene-g-glycidyl methacrylate Membrane in the Vapor Phase

  • Hwang, Taek-Sung;Park, Jin-Won
    • Macromolecular Research
    • /
    • 제11권6호
    • /
    • pp.495-500
    • /
    • 2003
  • UV-induced graft polymerization of glycidyl methacrylate (GMA) to a polypropylene (PP) membrane was carried out in the vapor phase with benzophenone (BP) as a photoinitiator. Attenuated total reflection Fourier transform infrared spectroscopy, atomic force microscopy (AFM), and scanning electron microscopy (SEM) were utilized to characterize the copolymer. The degree of grafting increased with increasing reaction time, increased UV irradiation source intensity, and increased immersion concentration of the BP solution. The optimum synthetic condition for the PP-g-GMA membrane was obtained with a reaction time of 2 hrs, a UV irradiation source intensity of 450 W, and an immersion concentration of the BP solution of 0.5 mol/L. The pure water flux decreased upon increasing the degree of grafting and increasing the amount of diethylamino functional group introduced. The analysis of AFM and SEM images shows that the graft chains and diethylamino groups of PP-g-GMA grew on the PP membrane surface, resulting in a change in surface morphology.

도마 Yurchenko 몸 펴 900도 비틀기 기술 분석 (The analysis of Yurchenko's 900 Degree Twist Technique with Stretched Body)

  • 여홍철
    • 한국운동역학회지
    • /
    • 제16권4호
    • /
    • pp.165-173
    • /
    • 2006
  • The purpose of this study was to analyze Yurchenko's 900 degree twist technique between the highly scored and the lowly scored subjects during the 2003 TaeGu Universiad Championship. The following results was obtained by analyzing horizontal, vertical and resultant velocities on 1st, 2nd, 3rd and 4th phases. The highly scored subject took longer total performance time but shorter time in 2nd and 300 phases. The highly scored subject also took longer performance time in 4th phase. In the board contact phase the highly scored subject had bigger elbow joint angle and shoulder joint angle. The highly scored subject had longer flying time and had more higher vertical height but lower horizontal and resultant velocities on 4th phase.

$10^{\circ}$상향분사된 혼합분류의 유동장 해석 (A Flow Field Analysis of Compound Jets Modified at a 10 Degree Upward Angle)

  • 박상규;이용호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권5호
    • /
    • pp.103-110
    • /
    • 2000
  • A two phase compound jet, which mixes pulverized solid particles with the air in the test section, is experimentally analyzed in this study. Two phase flow is jetted 10 degree upward in the primary jet, while the secondary jet utilizes the air only. The height difference between the primary and secondary central axises is 32.5mm. The velocity vector field, concentration field, and turbulent properties of solid particles are measured by using 3-Dimensional Particles Dynamics Analyzer. When the jet angle of the secondary jet goes into effect, the solid particle recirculation zone becomes larger. Also, solid particle concentration becomes more dense due to a velocity decrement of particles.

  • PDF

기후.환경 인자에 의한 옥외 절연물의 누설전류 특성 분석 (Leakage Current Properties Analysis of Outdoor Insulator on Climatic.Environmental Factor)

  • 이원영;심규일;한상옥;박강식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.27-30
    • /
    • 2002
  • In this paper, we were investigated leakage current properties of outdoor insulator on climatic environmental factor. Contamination is one of the most important factor to determine the performance of insulator. Thus, it is very important to exam the contamination degree on the outdoor insulator. There are many limits, such as reliability of data, interval of measurement and similarity of environmental conditions, in conventional method. So, we measured phase and leakage current of outdoor insulator using the temperature & humidity chamber. In this investigation, phase difference was measured to compare the variance of phase difference with the contamination degree and relative humidity.

  • PDF

Interactive Fuzzy Linear Programming with Two-Phase Approach

  • Lee Jong-Hwan
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제6권3호
    • /
    • pp.232-239
    • /
    • 2006
  • This paper is for applying interactive fuzzy linear programming for the problem of product mix planning, which is one of the aggregate planning problem. We developed a modified algorithm, which has two-phase approach for interactive fuzzy linear programming to get a better solution. Adding two-phase method, we expect to obtain not only the highest membership degree, but also a better utilization of each constrained resource.

복합조직강의 기계적 특성에 미치는 미시조직인자의 영향 (Effect of microstructure on mechanical properties in dual phase steel)

  • 김정규;유승원
    • 오토저널
    • /
    • 제9권3호
    • /
    • pp.76-84
    • /
    • 1987
  • A study has been made to clarify the microstructural effect on static tensile properties of the dual phase steel, in which the martensitic phase encapsulated islands of ferritic phase. The main results are as follows: Yield strength is associated with the degree of plastic constraint factor and tensile strength increases with increasing of strain hardening exponent. Also, the variation of ductility is dependent upon the amount of micro-brittle facets.

  • PDF

Ammonia Removal Model Based on the Equilibrium and Mass Transfer Principles

  • Yoon, Hyein;Lim, Ji-Hye;Chung, Hyung-Keun
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권3호
    • /
    • pp.555-561
    • /
    • 2008
  • In air stripping of ammonia from the aqueous solution, a new removal model was presented considering the equilibrium principles for the ammonia in aqueous solution and between the aqueous and air phase. The effects of pH, temperature and airflow rate on the ammonia removal were evaluated with the model. In addition, the saturation degree of ammonia in air was defined and used to evaluate the effect of each experimental factor on the removal rate. As pH (8.9 to 11.9) or temperature (20 to 50 oC) was increased, the overall removal rate constants in all cases were appeared to be increased. Our presented model shows that the degrees of saturation were about the same (0.45) in all cases when the airflow condition remains the same. This result indicates that the effect of pH and temperature were directly taken into consideration in the model equation. As the airflow increases, the overall removal rate constants were increased in all cases as expected. However, the saturation degree was exponentially decreased with increasing the airflow rate in the air phase (or above-surface) aeration. In the subsurface aeration the saturation degree remains a constant value of 0.65 even though the airflow rate was increased. These results indicate that the degree of saturation is affected mainly by the turbulence of the aqueous solution and remains the same above a certain airflow rate.

Power System Enhanced Monitoring through Strategic PMU Placement Considering Degree of Criticality of Buses

  • Singh, Ajeet Kumar;Fozdar, Manoj
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1769-1777
    • /
    • 2018
  • This paper proposes a method for optimal placement of Phasor Measurement Units (PMUs) considering system configuration and its attributes during the planning phase of PMU deployment. Each bus of the system is assessed on four diverse attributes; namely, redundancy of measurements, rotor angle and frequency monitoring of generator buses, reactive power deficiency, and maximum loading limit under transmission line outage contingency, and a consolidated 'degree of criticality' is determined using Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS). The major contribution of the proposed work is the development of modified objective function which incorporates values of the degree of criticality of buses. The problem is formulated as maximization of the aggregate degree of criticality of the system. The resultant PMU configuration extends complete observability of the system and majority of the PMUs are located on critical buses. As budgetary restrictions on utilities may not allow installation PMUs even at optimal locations in a single phase, multi-horizon deployment of PMUs is also addressed. The proposed approach is tested on IEEE 14-bus, IEEE 30-bus, New England (NE) 39-bus, IEEE 57-bus and IEEE 118-bus systems and compared with some existing methods.

대형 가상현실 공연장을 위한 360도 비디오 스트리밍 시스템 (360-degree Video Streaming System for Large-scale Immersive Displays)

  • 류영일;김건형;;;정세훈;류은석
    • 방송공학회논문지
    • /
    • 제27권6호
    • /
    • pp.848-859
    • /
    • 2022
  • 본 논문은 일반적으로 사용되는 2D 디스플레이 또는 HMD (Head-Mounted Display) 기반 VR (Virtual Reality, VR) 서비스에서 탈피하여, 대형 가상현실 공연장을 위한 360도 비디오 스트리밍 시스템을 제안한다. 제안된 시스템은 Phase 1, 2, 3의 연구개발 단계를 밟아 6DoF (Degrees of Freedom) 시점 자유도를 지원하는 360도 비디오 스트리밍 시스템을 개발하는 것을 최종목표로 하고 있으며, 현재는 Phase 1: 대형 가상현실 공연장을 위한 3DoF 360도 비디오 스트리밍 시스템 프로토타입의 개발까지 완료되었다. 구현된 스트리밍 시스템 프로토타입은 서브픽처 기반 Viewport-dependent 스트리밍 기술이 적용되어 있으며, 기존 방식과 비교하였을 때 약 80%의 비트율 감소, 약 543%의 영상 디코딩 속도 향상을 확인하였다. 또한, 단순 구현 및 성능평가에서 그치지 않고, 실제 미국 UCSB (University of California, Santa Barbara)에 위치한 대형 가상현실 공연장 AlloSphere에서의 시범방송을 수행하여, 향후 Phase 2, 3 연구단계를 위한 연구적 기반을 마련하였다.

상호 위상 변조에 의해 왜곡된 WDM 신호의 Mid-Span Spectral Inversion을 이용한 보상 (Compensation of Distorted WDM signals due to Cross Phase Modulation Effects using Mid-Span Spectral Inversion)

  • 이성렬
    • 한국항행학회논문지
    • /
    • 제7권2호
    • /
    • pp.128-134
    • /
    • 2003
  • 광섬유의 색 분산과 자기 위상 변조 외에 상호 위상 변조 효과에 의해 왜곡된 WDM 채널 신호가 MSSI(Mid-Span Spectral Inversion) 기법을 통해 전송 거리에 따라 보상되는 정도를 다양한 광섬유 분산 계수를 고려하여 분석해 보았다. 본 연구에서 고려된 시스템은 전체 전송로의 중간에 비선형 매질로 HNL-DSF (Highly nonlinear dispersion shifted fiber)를 갖는 광 위상 공액기를 두고, 광 위상 공액기를 중심으로 첫 번째 전송 구간에서의 평균 강도와 두 번째 전송 구간에서의 평균 강도를 같게 하는 PAIA (Path Averaged Intensity Approximation) 방식의 MSSI 기법을 채택한 $3{\times}40$ Gbps 강도 변조 직접 검파 방식의 WDM 시스템이다. XPM에 의한 왜곡의 보상 측면에서 광섬유의 분산 계수가 비교적 큰 WDM 시스템일수록 MSSI 기법이 더욱 효과적으로 적용되어 전송 거리를 신장시킬 수 있는 것을 확인할 수 있었다. 또한 색 분산, SPM 외에 XPM의 영향을 받아 왜곡된 채널 신호는 MSSI 기법을 통해 광섬유의 분산 계수가 큰 시스템에서 더욱 안정되게 보상된다는 것을 알 수 있었다.

  • PDF