• Title/Summary/Keyword: Phase Variable

Search Result 1,066, Processing Time 0.034 seconds

PULSATIONAL CHARACTERISTICS OF $\delta$ SCUTI VARIABLE HR1170

  • Kim, Seoung-Li;Lee, See-Woo
    • Journal of The Korean Astronomical Society
    • /
    • v.23 no.1
    • /
    • pp.1-13
    • /
    • 1990
  • New uvby photoelectric photometry was carried out for a $\delta$ Scuti variable, HR1170. By applying the Fourier method and the linear least square method, three frequencies were derived: $f_1=10.06134c/d$ ($P_1=0.^d0994$). $f_2=11.91754c/d$ ($P_2=0.^d0839$). $f_3=18.96776c/d$ ($P_3=0.^d0527$). From the observed pulsational constants and from the phase difference and amplitude ratios for color(b-y) and magnitude y. three different pulsation modes (n, l) of $f_1(0,0)$, $f_2(1,2)$, $f_3(3,2)$ are deduced, indicating the existence of nonradial mode in HR1170. Some physical parameters indicate that HR1170 is evolving at the stage of H-shell burning.

  • PDF

Comparison of Operating Characteristics for DFIG and FSIG wind Turbine Systems with Respect to Variable Interconnecting Line Conditions (연계선로의 조건 변화에 따른 DFIG와 FSIG 풍력발전시스템의 운전특성 비교)

  • Ro, Kyoung-Soo;Kim, Tae-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.8-15
    • /
    • 2010
  • This paper analyzes the steady-state output characteristics of variable-speed wind turbine systems using doubly-fed induction generators(DFIG) compared with fixed-speed induction generator(FSIG) wind turbine systems. It also presents simulations of a grid-connected wind turbine generation system for dynamics analysis on MATLAB/Simulink and compares the responses between DFIG and FSIG wind turbine systems with respect to wind speed variation, impedance changes and X/R ratio changes of interconnecting circuits. Simulation results show the variation of generator's active output, terminal voltage and fault currents at the interconnecting point. Case studies demonstrate that DFIG wind turbine systems illustrate better performance to 3-phase fault than FSIG's.

Constant Power Control of Variable Input Robust Resonant FB DC-DC Converter (순시 가변입력에 강인한 공진형 FB DC-DC Converter의 정출력 제어)

  • Hwang, Y.M.;Park, S.W.;Choi, S.F.;Shin, D.R.;Chung, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1351-1353
    • /
    • 2000
  • In this paper, it is proposed to constant power control of solar power system. The solar power system has disadvantage that low power density and variable power output. Proposed strategy is controled by DC/DC converter using phase shift PWM and I-PD type control applying type 1 digital system. The validity of proposed control strategy is verified from simulations results using PSIM.

  • PDF

The effect of heat treatment mass flow on superconducting property of Bi-2223/Ag Tapes. (열처리 가스유량에 따른 Bi-2223/Ag 초전도 테이프의 특성에 미치는 영향)

  • 양주생;하동우;이동훈;최정규;황선역;오상수;김상철;김명호
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.96-98
    • /
    • 2003
  • Many of research efforts have been focused on the improvement of critical current density Jc of silver-sheathed Bi-2223 tapes for practical applications of material. Bi-2223 superconducting wires with 55 filaments were fabricated by stacking, drawing process with different heat-treatment histories. After rolling process, Bi-2223 tapes were heat-treatment at 780~826$^{\circ}C$ with variable mass flow rate of mixed gas. In this study, the effect of changes in the variable mass flow rate of mixed gas during the heat treatment of Bi-2223/Ag tapes has been investigated. Distinct differences were observed in the Bi-2223 phase and critical current as flow rate of mixed gas. We could achieve proper conditions of mass flow rate of mixed gas for Ag-alloy clad Bi-2223 superconducting tapes.

  • PDF

Design of a Variable Structure Adaptive Model Following Controller (可變 構造適應모델 追從 制御器의 設計)

  • Lee, Kang-Woong;Choi, Keh-Kun
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.4
    • /
    • pp.27-34
    • /
    • 1989
  • An adaptive model following controller is designed using the theory of variable structure systems. The proposed method based on the modified condition for the sliding mode allows the designer to satisfy the requirements to speed up the reaching phase and for the magnitude of the chattering to be reduced in the sliding mode. Chattering reduction is obtained by the replacement of control input in the neighborhood of the sliding plane. The results of computer simulation show that state trajectories reach switching plane fast and chattering is reduced.

  • PDF

A Novel Method for Measuring the Ground Impedance using Variable Frequency Inverter (가변주파수 인버터를 이용한 접지임피던스의 새로운 측정기법)

  • 이복희;엄주홍
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.253-257
    • /
    • 2004
  • In order to analyze the frequency dependance of ground impedance in grounding grids for lightning and surge protection, a novel method for measuring the ground impedance as a function of frequency were experimentally investigated. The experiments were carried out in rectangular grounding grids with $6{\times}8$ conductors of 22 $mm^2$ buried at a depth of 0.5 m. The test current was injected by the variable frequency inverter whose frequency is linearly controlled for the established period in the range of 5∼500 KHz. The amplitude and phase of ground impedance were calculated from the waveforms of the test current and ground potential rise measured by the band-pass filter tuned in a specific frequency. The frequency dependence of ground impedance was mainly caused by the inductive current flowing through grounding conductors over the frequency of 100 KHz. The proposed measurement method of ground impedance would be applicable to evaluate the transient response characteristics in lightning protection grounding systems.

A Study on the Starting Characteristic of Variable Speed Centrifugal Chiller (가변속 터보냉동기의 기동특성에 관한 연구)

  • Kim, Hee-Sun;Yun, Hong-Min;Na, Seung-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.512-513
    • /
    • 2012
  • The electric motor is essential to drive turbo machinery. In order to overcome the speed limitations of general motors, the inverter is used to perform high speed to tens of rpm. The high speed drives are widely used in many applications such as turbo blower, turbo centrifugal compressors, and pump using air bearing technique. Starting of high speed motor can cause step out, stall, oscillation of motor because the phase inductance is much smaller than that of ordinary motor. This paper studied on the starting characteristic of variable speed centrifugal chiller considering high speed motor characteristics. Finally, the superiority of the inverter is verified by experimental results.

  • PDF

A Study On The New Intermittent Message Acquisition Board Using FPGA For Next-Generation High-Speed Rail (차세대 고속철도 증속 운전에 대응하는 불연속 정보 수신보드 개발에 관한 연구)

  • Han, Jae-Mun;Um, Jung-Kyu;Yang, Chan-Seok;Cho, Yong-Gee
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.351-355
    • /
    • 2009
  • There are two types of controller between railway and train. those are the Continuous Message Controller and the Intermittent Message Controller using for KHSR. The conventional Intermittent Message Controller board used a variable resister for setting the phase, but the variable resister affected some environmental facts, such as temperature, humidity, and vibration, etc. And It is requirement of reduction message processing time for speed-up operation in Next-Generation High-Speed Rail. This study suggests how to solve the problem described above. Using FPGA is quite profitable. It's easy to use and maintain, flexible with the New algorithm to fix up the problem.

  • PDF

Variable Proportional Resonance Current Control Technique for Variable Speed Operation of Single-Phase Permanent Magnet Synchronous Motor (단상 영구자석 동기 전동기의 가변속 운전을 위한 가변 비례공진 전류 제어 기법)

  • Lee, Won-Seok;Shin, Im-Su;Yoo, Sang-Min;Hwang, Seon-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.433-434
    • /
    • 2020
  • 본 논문은 단상 영구자석 동기 전동기의 가변속 운전을 위한 가변 비례공진 전류 제어 기법을 제안한다. 단상 영구자석 동기 전동기의 전류 제어 시 3상 교류 전동기에 널리 적용되는 벡터 제어를 적용할 경우, 필연적으로 좌표변환 및 가상의 q축 성분 생성을 위한 과정이 요구된다. 하지만, 단상 영구자석 동기 전동기의 구조적인 특징을 고려하여 비례공진 제어 기법을 적용하게 되면 3상 교류 시스템에서 필요로 하는 추가적인 좌표변환 과정이 요구되지 않는다. 이에 본 논문에서는 가변속 운전에 따른 공진 주파수 변화를 반영한 가변 비례공진 전류제어 기법을 제안하고자 한다. 제안한 전류 제어 기법의 효용성을 검증하기 위해 다수의 실험을 진행하였다.

  • PDF

A Design and Construction of Phase-locked Dielectric Resonator Oscillator for VSAT (VSAT용 위상고정 유전체 공진 발진기의 설계 및 구현)

  • 류근관;이두한;홍의석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.10
    • /
    • pp.1973-1981
    • /
    • 1994
  • A PLDRO(Phase Locked Dielectric Resonator Oscillator) in Ku-band(10.95-11.70GHz) is designed with the concept of the feedback property of PLL(Phase Locked Loop). A series feedback type DRO is developed, and VCDRO(Voltage Controlled Dielectric Resonator Oscillator) using a varactor diode as a voltage-variable capacitor is implemented to tune oscillating frequency electrically. Then, PLDRO is designed by using a SPD(Sampling Phase Detector). This PLDRO is phase-locked voltage controlled DRO to reference source(VHF band) by SPD at 10.00 GHz for European FSS(Fixed Satellite Service). The PLDRO generates output power greater than 10dBm at 10.00 GHz and has phase noise of -80 dBc/Hz at 10 KHz offset from carrier. This PLDRO achieves much better frequency stability than conventional VCDRO.

  • PDF