• Title/Summary/Keyword: Phase Variable

Search Result 1,065, Processing Time 0.022 seconds

Study on the Phase Noise of Voltage Controlled Oscillator (전압조절발진기의 위상잡음 연구)

  • Park, Se-Hoon;Seo, Hee-Sung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.1057-1060
    • /
    • 2005
  • Noises from circuits components and interference with other circuits components generate the phase noise in voltage controlled oscillators (VCO). The effects of the random noise on the phase noise is depending on the instant when the noise enters the VCO. When the noise enters at the transition time of the output of VCO, the effect is most prominent. Using this time variable system, it is revealed that the power spectral density of phase noise of VCO is made of the integrated noise powers of frequency components slightly offset from the fundamental and harmonic frequencies.

  • PDF

A Self-Excited Induction Generator with Simple Voltage Regulation Suitable for Wind Energy

  • Ahmed Tarek;Nishida Katsumi;Nakaoka Mutsuo
    • Journal of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.205-216
    • /
    • 2004
  • In this paper, a three-phase induction machine-based wind power generation scheme is proposed. This scheme uses a low-cost diode bridge rectifier circuit connected to an induction machine via an ac load voltage regulator (AC-LVR) to regulate dc power transfer. The AC-LVR is used to regulate the DC load voltage of the diode bridge rectifier circuit which is connected to the three-phase self-excited induction generator (SEIG). The excitation of the three-phase SEIG is supplied by the static VAR compensator (SVC). This simple method for obtaining a full variable-speed wind turbine system by applying a back-to-back power converter to a wound rotor induction generator is useful for wind power generation at widely varying speeds. The dynamic performance responses and the experimental results of connecting a 5kW 220V three-phase SEIG directly to a diode bridge rectifier are presented for various loads. Moreover, the steady-state simulated and experimental results of the PI closed-loop feedback voltage regulation scheme prove the practical effectiveness of these simple methods for use with a wind turbine system.

A Study on Phi Directional Monostatic RCS Reduction of the Aluminum Plate using the Oscillation System (Oscillation System을 이용한 알루미늄판의 Phi방향 Monostatic RCS 감쇄 연구)

  • Hwang, Joosung;Park, Sangbok;Jang, Sunghoon;Cheon, Changyul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.228-231
    • /
    • 2013
  • This paper proposes a new method that reduces RCS(rader cross section) of the aluminum plate using a oscillation system composed of a VGA(variable gain amplifier) and a phase shifter. Once the oscillation system receives the external-RF signal through a probe on aluminum plate, it makes an amplified signal with a specific phase to cancel the signal reflected from the aluminum plate. The signal transmitted from the oscillation system has the same amplitude and out of phase with the reflected signal. And it can be controlled by the VGA and the phase shifter in the oscillation system. In order to validate the performance of the proposed oscillation system, FEM simulator was used and we measured how much an amplitude of the signal reflected from the aluminum plate rotated in phi direction is reduced in an anechoic chamber.

Development of the Harmonics Reduction and Energy Saving Equipment in Variable Loads (부하변동 시의 고조파제거 및 절전기 개발)

  • Song, Young-Bok;Cho, Yong-Hyun;Choi, Dong-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.87-95
    • /
    • 2006
  • In this study, in order to obtain high qualify of electric power, single phase active filter which is composed of Zig-Zag transformer and three phase bridge rectifier and capacitor at the secondary of its transformer to be able to reduce the components of the zero phase current and the third harmonic current in neutral line and power line respectively. By connecting this filter to the Zig-Zag transformer and nonlinear load, their third harmonic components due to the nonlinear loads were reduced.

Operating Characteristics of Squirrel-Cage Induction Motor of 5-Phase 1.5kW (5상 1.5kW 농형 유도전동기의 운전특성)

  • Kim, Min-Huei;Jung, Hyung-Woo;Song, Hyun-Jig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.5
    • /
    • pp.52-59
    • /
    • 2014
  • This paper presents an improved operating characteristics of squirrel-cage induction motor(IM) for 5-phase 1.5kW, 220V, 60Hz in order to study a polyphase AC machinery that keep hold of advantages more than traditional three-phase a IM, such as reducing a amplitude of torque pulsation, decreasing electric noises, and increasing the reliability. The developed manufacturing motor was necessary to do improvement of speed regulation, efficiency, operating characteristics, and so on at rated load. There are remake a redesigned and distributed stator winding connection without changing the frames of stator and rotor core in previous established the motor by a repeat tests. There are shown a experiments results of no-load test, locked rotor test, operating characteristics at variable load, FFT analysis of harmonics within output voltages and current waveform, decided motor parameters.

An Improved Operating Characteristics of Surface Permanent Magnetic Synchronous Generator for 5-Phase 5kW (5상 5kW 표면부착형 영구자석 동기발전기 특성개선)

  • Jung, Hyung-Woo;Kim, Min-Huei;Song, Hyun-Jik;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.53-61
    • /
    • 2013
  • This paper propose a improved operating characteristics of the 5-phase 5kW within developed the surface permanent mount synchronous generator (SPMSG) in order to make a study of a polyphase ac motors keeping hold of more advantages. The developed manufacturing motor was necessary to do improvement of voltage regulation, efficiency, operating characteristics, and so on at the rated load. There are remake a redesigned and distributed stator winding connection without changing the frames of stator and rotor core in previous established generator by a repeat tests. There are shown a amplitude and waveform of the generated electromotive force, FFT analysis of harmonics within output voltages, and reviewing a experiment results in load of resistive and 5-phase induction motor by variable generator output frequency.

Ductile fracture simulation using phase field approach under higher order regime

  • Nitin Khandelwal;Ramachandra A. Murthy
    • Structural Engineering and Mechanics
    • /
    • v.89 no.2
    • /
    • pp.199-211
    • /
    • 2024
  • The loading capacity of engineering structures/components reduces after the initiation and propagation of crack eventually leads to the final failure. Hence, it becomes essential to deal with the crack and its effects at the design and simulation stages itself, by detecting the prone area of the fracture. The phase-field (PF) method has been accepted widely in simulating fracture problems in complex geometries. However, most of the PF methods are formulated with second order continuity theoryinvolving C0 continuity. In the present study, PF method based on fourth-order (i.e., higher order) theory, maintaining C1 continuity has been proposed for ductile fracture simulation. The formulation includes fourth-order derivative terms of phase field variable, varying between 0 and 1. Applications of fourth-order PF theory to ductile fracture simulation resulted in novelty in this area. The proposed formulation is numerically solved using a two-dimensional finite element (FE) framework in 3-layered manner system. The solutions thus obtained from the proposed fourth order theory for different benchmark problems portray the improvement in the accuracy of the numerical results and are well matched with experimental results available in the literature. These results are also compared with second-order PF theory and a comparison study demonstrated the robustness of the proposed model in capturing ductile behaviour close to experimental observations.

Design of Multilevel Variable Output Voltage AC-DC Converter for Power Amplifier of Underwater Acoustic Sensor (수중 음향센서용 전력증폭기를 위한 멀티레벨 가변전압출력 AC-DC 전원회로 설계)

  • Lee, Chang-Yeol;Kim, In-Dong;Nho, Eui-Cheol;Moon, Won-Kyu;Kim, Won-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.72-83
    • /
    • 2013
  • The paper proposes a new multilevel variable output voltage AC/DC Converter for power supply of power amplifiers used in underwater acoustic sensors. The proposed multilevel variable output voltage AC/DC Converter is composed of two parts. One as the input section is the high efficiency phase-shifted PWM full bridge DC-DC converter to get multiport power sources. The other as the output section is composed of two flying-capacitor 3-level DC-DC converters and a diode bridge circuit to get fast-response and multilevel variable output voltage for an envelope amplifier. Also the paper suggests the detailed circuit topology and design guideline of multilevel variable output voltage AC/DC converter. It also proposes the power balanced control method between 3-level converters and the voltage balanced algorithm for flying capacitors. Its characteristics should be verified by the detailed simulation results. It is anticipated that the proposed converter will be used very well for power amplifiers used in underwater acoustic sensors.

Design of High-Order Moving Sliding Surface via Fuzzy Algorithm (퍼지 알고리듬을 이용한 고차 이동슬라이딩서피스의 설계)

  • Park, Dong-Won;Choi, Seung-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.1
    • /
    • pp.32-44
    • /
    • 1997
  • A moving sliding surface(MSS) was proposed earlier for the second-order variable structure control system(VSCS). The MSS was disigned to pass arbitrary initial conditions, and subsequently moved towards a predetermined sliding surface by rotating and/or shifting. This methodology led to fast and robust control responses of the second-order VSCS, especially in a reaching phase. However, the moving algorithm of the MSS was too complicated to be employed to the high-order VSCS. To resolve this problem, a new moving algorithm based on the fuzzy theory is proposed in this paper. For the generalization of the MSS, the conditions for rotating or shifting are firstly investigated. Then the fuzzy algorithm is formulated by adopting the values of the surface function and the total discontinuity gain as input variables, and the variation of the surface function as output variable. The position control problem of an electrohydraulic servomechanism is adopted in order to demonstrate the efficiency and the feasibility of the proposed MSS associated with fuzzy algorithm.

Dynamic Analysis of Variable Speed Wind Power Systems with Doubly-Fed Induction Generators (이중여자 유도발전기에 의한 가변속 풍력 발전시스템의 동특성 해석)

  • Choi, Jang-Young;Jang, Seok-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.6
    • /
    • pp.325-336
    • /
    • 2006
  • This paper deals with the dynamic analysis of variable speed wind power systems with doubly-fed induction generators (DFIG). First, the mathematical modeling of wind farm which consists of turbine rotor, DFIG, rotor side and grid side converter and control systems is presented. In particular, the equation for dynamic modeling of the DFIG and the AC/DC/AC converter is expressed as dq reference frame. And then, on the basis of mathematical modeling for each component of wind farm, dynamic simulation algorithms for speed and pitch angle control of wind turbine and generated active and reactive power control of the DFIG and the AC/DC/AC converter are established. Finally, Using the MATLAB/SIMULINK, this paper presents dynamic simulation model for 6MW wind power generation systems with the DFIG considering distribution systems and performs the dynamic analysis of wind power systems in steady state. Moreover, this paper also presents the dynamic performance for the case when the voltage sag in grid source and phase fault in bus are occurred.