• 제목/요약/키워드: Phase Sensor

검색결과 1,062건 처리시간 0.029초

위상변화를 이용한 표면탄성파 가스센서 (Surface acoustic wave gas sensors by utilizing the phase change)

  • 김진상;정용철;강종윤;김달영;남창우;윤석진
    • 센서학회지
    • /
    • 제14권3호
    • /
    • pp.186-190
    • /
    • 2005
  • This paper describes the development of a surface acoustic wave gas sensor that is designed to detect volatile gas by monitering phase change of output signal as a function of time. The sensor consists of SAW oscillators with a center frequency of 100 MHz fabricated on $128^{\circ}$ Y-Z $LiNbO_{3}$ substrates. Experimental results, which show the phase change of output signal under the absorption of volatile gas onto sensors, are presented. The proposed sensor has the properties of high sensitivity compare to the conventional SAW gas sensor and chemical selectivity. Thus, it is thought these results are applicable for use in sensor array of an high performance electronic nose system.

보행주기 검출용 모션 센서 시스템의 비교 (Comparison of Motion Sensor Systems for Gait Phase Detection)

  • 박선우;손량희;류기홍;김영호
    • 한국정밀공학회지
    • /
    • 제27권2호
    • /
    • pp.145-152
    • /
    • 2010
  • Gait phase detection is important for evaluating the recovery of gait ability in patients with paralysis, and for determining the stimulation timing in FES walking. In this study, three different motion sensors(tilt sensor, gyrosensor and accelerometer) were used to detect gait events(heel strike, HS; toe off, TO) and they were compared one another to determine the most applicable sensor for gait phase detection. Motion sensors were attached on the shank and heel of subjects. Gait phases determined by the characteristics of each sensor's signal were compared with those from FVA. Gait phase detections using three different motion sensors were valid, since they all have reliabilities more than 95%, when compared with FVA. HS and TO were determined by both FVA and motion sensor signals, and the accuracy of detecting HS and TO with motion sensors were assessed by the time differences between FVA and motion sensors. Results show of that the tilt sensor and the gyrosensor could detect gait phase more accurately in normal subjects. Vertical acceleration from the accelerometer could detect HS most accurately in hemiplegic patient group A. The gyrosensor could detect HS and TO most accurately in hemiplegic patient group A and B. Valid error ranges of HS and TO were determined by 3.9 % and 13.6 % in normal subjects, respectively. The detection of TO from all sensor signals was valid in both patient group A and B. However, the vertical acceleration detected HS validly in patient group A and the gyrosensor detected HS validly in patient group B. We could determine the most applicable motion sensors to detect gait phases in hemiplegic patients. However, since hemiplegic patients have much different gait patterns one another, further experimental studies using various simple motion sensors would be required to determine gait events in pathologic gaits.

I/Q 변조 풀이 방식의 헤테로다인 간섭계를 이용한 미소 전기장 및 복굴절 측정 (A new, hybrid, heterodyne, fiber-optic electric field sensor scheme and its applications)

  • 윤신영;조규만;이용산
    • 한국광학회지
    • /
    • 제8권2호
    • /
    • pp.161-164
    • /
    • 1997
  • 편광유지 광섬유를 이용한 주파수가 안정화된, 두 개의 서로 수직으로 편광된 종모우드를 갖는 He-Ne레이저 빛을 LoTa $O_{3}$ 위상변조기로 구성된 센서부(sensor head)로 전달해 줌으로써 원격에서 전기장을 측정할 수 있는 hybrid, heterodyne 간섭식 센서를 구성하였다. In/quadrature-phase위상변조풀이 방식을 이용하여 전기광학 효과에 의해 서로 수직으로 편광된 두 모우드 사이에 유도된 위상차이를 측정함으로써 항상 높은 검지율을 유지할 수 있는 전기장 센서를 구성하고, 이를 이용하여 광학 물질에 유도된 복굴절도 측정을 할 수 있었다.

  • PDF

예측 상태 관측기를 이용한 3상 전압 원 PWM 컨버터의 단일 센서 전류 제어 (Single Sensor Current Control for Three-Phase Voltage-Source PWM Converters Using a Predictive State Observer)

  • 이우철;현동석;이택기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.489-492
    • /
    • 1999
  • This paper proposes a control method for three-phase voltage-source PWM converters using only a single current sensor in the DC link. A predictive current controller for the voltage-source PWM converter is used so that all phase currents can be reconstructed in a switching period although one or two of active vectors are applied only for a short time. Compensation of the 2 step delays is also included. In this paper single sensor current control using predictive state observer will be discussed, and investigated experimentally.

  • PDF

다채널 단일톤 위상 측정칩 개발 (Development of a Sensor Chip for Phasor Measurement of Multichannel Single Tone Signals)

  • 김병일;홍근표;황진용;장태규
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.497-500
    • /
    • 2005
  • This paper presents a design of a hybrid sensor chip which integrates an A/D converter module and a phase measurement module for measuring power line phase. Recursive sliding DFT based phase measurement module is designed using time shared multiplier which can reduce the size of SoC implementation. A/D converter is based on the sigma delta modulation in order to minimize the implementation space of the analog part and designed to obtain 8-bit resolution. Computer simulations and FPGA implementation are performed to verify hybrid sensor chip design. The hybrid sensor chip for 4-channel power line phase measurement is fabricated by using 0.35 micrometer CMOS process.

  • PDF

황환원 세균의 quorum-sensing 유사 현상

  • 박지은;장덕진
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2001년도 추계학술발표대회
    • /
    • pp.545-548
    • /
    • 2001
  • Microbiologically influenced corrosion (MIC) of metal is common in the natural environment and sulfate reducing bacteria are representative microorganisms for MIC. We found that biofilm fomlation by SRB on the metal surface might be controlled by quorum sensing, which is a cell density dependent regulation of cell metabolism. As cell free culture fluids (spent media) of Desulfovibrio vulgaris and D. desulfuricans were tested for quontrn sensing related test strains, it was found that spent media of two SRB induced increased luminescence of Vibrio harveyi BB886 (sensor 1+, sensor 2-) and BB170 (sensor 1-, sensor 2+). Quorum activities of D. vulgaris and D. desulfuricans appeared to be parallel to growth patterns, i.e., it was low in the lag phase, highly increased in the exponential phase, and reached maximum in the stationary phase. Interestingly, however, luminescence of V. harveyi BB886 and BB170 induced by a unit cell mass of the SHB showed a maximal peak in the late lag phase. Hence, it was suspected that quorum sensing of these two SHB play unknown roles in shifting cells from dormant to growth stages.

  • PDF

초음파 센서를 이용한 변위 측정 시스템 개발 (A Development of Displacement Measurement System using Ultrasonic Sensor)

  • 김정섭;김상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.142-145
    • /
    • 1995
  • This paper is to develop a measurement system of the displacement distance using ultrasonic sensors. Two 400KHz ultrasonic sensors are used for realizing the measurement system, such as one sensor transmits the sine wave and the other sensor receives this wave. The displacement is measured by the phase difference between transmitting and receiving signals. A phase defecter transforms phase difference to voltage. Because the output voltage pattern has nonlinear characteristics, the relations of the voltage and the distance are learned by a neural network. As the results of teaming, the efficiency of measurement system is improved. This system can measure the displacement distance at the accuracy of 1 micrometer level.

  • PDF

한 상의 전류검출에 의한 6/4극 SRM의 3상 Delta modulation 전류제어 (Current control of 6/4 pole SRM with Delta modulation using Single current sensor)

  • 김도군;윤용호;송상훈;원충연;김영렬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.671-676
    • /
    • 2003
  • This paper presents 3-phase current regulation of SR motor by only single current sensor. The conventional drive system of SR motor has a current sensor per each phase. In this paper, The asymmetric bridge converter which Is able to control independently phases and be excited simultaneously is used fs the driver system for 6/4 poles SR motor. And the sensor Is replaced 3 sensors of each phase with only one on bus line of converter so as to detect current of every phase. A drive logic circuit is designed on EPLD with Delta modulation using a fixed frequency This technique is verified through simulation and experiment.

  • PDF

EPLD 로직구현을 통한 델타변조기법에 의한 스위치드 리럭턴스 전동기의 전류제어 (Current Control of Switched Reluctance Motor with Delta Modulation Method on EPLD Logic Design)

  • 윤용호;김재문
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.356-361
    • /
    • 2008
  • The conventional drive system of SRM has a current sensor per each phase. The torque demand signal generated by the outer control loop is translated into individual current reference signal for each phase. The torque is controlled by regulating these currents. Using the SRM in a variable-speed control, the phase currents are generally regulated to achieve a square wave. The simplest form of current regulation uses fixed frequency delta modulation of the phase voltages. The aim of this paper is to regulate 3-phases current of SRM by only single current sensor using delta modulation with digital chip. In this paper, the asymmetric bridge converter which is able to control independently phases and be excited simultaneously is used as the driver system for 6/4 poles SRM. And the current sensor is replaced 3 sensors of each phase with only one on bus line of converter so as to detect current of every phase. The proposed delta modulation technique has been implemented in a simple digital logic circuit using EPLD(Electrically Programmable Logic Device). This method is verified through simulation and experiment results.

탄성 표면파를 이용한 점도 센서의 개발 (Development of viscosity sensor using surface acoustic wave)

  • 정우석;김기범;강형섭;홍철운
    • 센서학회지
    • /
    • 제17권4호
    • /
    • pp.289-294
    • /
    • 2008
  • The purpose of this study is to materialize the viscosity sensor by using the SH-SAW sensor of which the center frequency is operated at higher than 50 MHz. In order to measure the viscosity, SAW sensor of which the center frequency is operated at 100 MHz is developed. By using the developed sensor, phase shift, delay time, insertion loss, and frequency variation are measured at different viscosity. The result shows that the phase shift difference between the viscosity variations is such that the difference between the distilled water and the 100 % glycerol solution is approximately $45^{\circ}$, the change of the insertion loss is approximately 9 dB, and the difference of frequency variation is approximately 5.9 MHz. Therefore, it is shown that viscosity of unknown solution can be measured with the surface acoustic wave sensor.