Browse > Article

Comparison of Motion Sensor Systems for Gait Phase Detection  

Park, Sun-Woo (Department of Biomedical Engineering, Institute of Medical Engineering, Yonsei Univ.)
Sohn, Ryang-Hee (Department of Biomedical Engineering, Institute of Medical Engineering, Yonsei Univ.)
Ryu, Ki-Hong (Department of Biomedical Engineering, Institute of Medical Engineering, Yonsei Univ.)
Kim, Young-Ho (Department of Biomedical Engineering, Institute of Medical Engineering, Yonsei Univ.)
Publication Information
Abstract
Gait phase detection is important for evaluating the recovery of gait ability in patients with paralysis, and for determining the stimulation timing in FES walking. In this study, three different motion sensors(tilt sensor, gyrosensor and accelerometer) were used to detect gait events(heel strike, HS; toe off, TO) and they were compared one another to determine the most applicable sensor for gait phase detection. Motion sensors were attached on the shank and heel of subjects. Gait phases determined by the characteristics of each sensor's signal were compared with those from FVA. Gait phase detections using three different motion sensors were valid, since they all have reliabilities more than 95%, when compared with FVA. HS and TO were determined by both FVA and motion sensor signals, and the accuracy of detecting HS and TO with motion sensors were assessed by the time differences between FVA and motion sensors. Results show of that the tilt sensor and the gyrosensor could detect gait phase more accurately in normal subjects. Vertical acceleration from the accelerometer could detect HS most accurately in hemiplegic patient group A. The gyrosensor could detect HS and TO most accurately in hemiplegic patient group A and B. Valid error ranges of HS and TO were determined by 3.9 % and 13.6 % in normal subjects, respectively. The detection of TO from all sensor signals was valid in both patient group A and B. However, the vertical acceleration detected HS validly in patient group A and the gyrosensor detected HS validly in patient group B. We could determine the most applicable motion sensors to detect gait phases in hemiplegic patients. However, since hemiplegic patients have much different gait patterns one another, further experimental studies using various simple motion sensors would be required to determine gait events in pathologic gaits.
Keywords
Motion Sensors; Gait Phase Detection; Hemiplegia;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 O'Conner, C. M., Thorpe, S. K., O'Malley, M. J. and Vaughan, C. L., "Automatic detection of gait events using kinematic data," Gait & Posture, Vol. 25, No. 3, pp. 469-474, 2007.   DOI   ScienceOn
2 Morris, J. R., "Accelerometry - a technique for the measurement of human body movements," J Biomechanics, Vol. 6, No. 6, pp. 729-736, 1973.   DOI   ScienceOn
3 Bland, J. M. and Altman, D. G., "Statistical method for assessing agreement between two methods of clinical measurement," The Lancet, Vol. 327, No. 8476, pp. 307-310, 1986.   DOI
4 Auvinet, B., Chaleil, D. and Barrey, E., "Accelerometric gait analysis for use in hospital outpatients," Rev. Rhum. Engl. Ed., Vol. 66, No. 7-9, pp. 389-397, 1999.
5 Dai, R., Stein, R. B., Andrews, B. J., James, K. B. and Wieler, M., "Application of tilt sensors in functional electrical stimulation," IEEE Transactions on Rehabilitation Engineering, Vol. 4, No. 2, pp. 63-72, 1996.   DOI   ScienceOn
6 Ahn, S. C., Hwang, S. J., Kang, S. J. and Kim, Y. H., "Development and evaluation of a new gait phase detection system using FSR sensors and a gyrosensor," Journal of the Korean Society for Precision Engineering, Vol. 21, No. 10, pp. 196-203, 2004.
7 Brandell, B. R., "Development of a universal control unit for functional electrical stimulation (FES)," Am. J. Phys. Med., Vol. 61, No. 6, pp. 279-301, 1982.
8 Tong, K. and Granat, M. H., "A practical gait analysis system using gyroscopes," Medical Engineering & Physics, Vol. 21, No. 2, pp. 87-94, 1999.   DOI   ScienceOn
9 Sekine, M., Abe, Y., Sekimoto, M., Higashi, Y., Fujimoto, T., Tamura, T. and Fukui, Y., "Assessment of gait parameter in hemiplegic patients by accelerometry," Proc. of IEEE Annual International Conference on Engineering in Medicine and Biology Society, Vol. 3, pp. 1879-1882, 2000.
10 Hreljac, A. and Marshall, R. N., "Algorithm to determine event timing during normal walking using kinematic data," J. of Biomechanics, Vol. 33, No. 6, pp. 783-786, 2000.   DOI   ScienceOn
11 Evans, A. L., Duncan, G. and Gilchrist, W., "Recording accelerations in body movements," Med. Biol. Eng. Comput., Vol. 29, No. 1, pp. 102-104, 1991.   DOI   ScienceOn
12 Weber, D. J., Stein, R. B., Chan, K. M., Loeb, G., Richmond, F., Rolf, R., James, K. and Chong, S. L., "BIONic WalkAide for correcting foot drop," IEEE Transactions on Neural Systems and Rehabilitation Engineering, Vol. 13, No. 2, pp. 242-246, 2005.   DOI   ScienceOn