• 제목/요약/키워드: Phase Effect

검색결과 7,702건 처리시간 0.035초

$ZrO_2$ 의 입자크기과 상분포에 미치는 소결분위기 영향 (Sintering Atmosphere Effect on the Grain Size and Phase Distribution of a Zirconia)

  • 백용균;안중호
    • 한국세라믹학회지
    • /
    • 제36권11호
    • /
    • pp.1198-1204
    • /
    • 1999
  • The effect of sintering atmosphere on the grain sizes and phase distributions in 3Y-ZrO2 and 8Y-ZrO2 was investigated O2 and N2 were used as sintering atmospheres. In the case of 3Y-ZrO2 the sintered density was higher in N2 than in O2 while in the case of 8Y-ZrO2 contrary results were obtained. The observation can be explained by the nitrogen solubility into the zirconia lattice. That is nitrogen gas can behave as a diffusive gas contrary to the behavior in other oxides depending on the amount of Y2O3. In 3Y-ZrO2 tetragonal phase was retained at room temperature irrespective of sintering atmospheres. Grain sizes of two specimens were below 2㎛ and larger in O2 thin in N2 Under a given stress the transformability of tetragonal phase into monoclinic phase was higher in O2 than N2. The results are discussed on the basis of an effect of the grain size and non-transformable ttragonal(t') phase.

  • PDF

상호결합효과와 리액턴스효과를 제거한 765kV 비연가 송전선로 보호용 거리계전 알고리즘 (A New Distance Relaying Algorithm Immune to Mutual Coupling Effect and Reactance Effect for 765kV Untransposed Parallel Transmission Lines)

  • 안용진;강상희
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권1호
    • /
    • pp.25-30
    • /
    • 2005
  • An accurate digital distance relaying algorithm which is immune to mutual coupling effect and reactance effect of the fault resistance and the load current for the line faults in 765kV untransposed transmission lines is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the magnitude and phase of the apparent impedance, this algorithm uses the angle of an impedance deviation vector. The impedance correction algorithm for phase-to-ground fault and phase-to-phase short fault use a voltage equation at fault point to compensate the fault current at fault point. A series of tests using EMTP output data in a 765kV untransposed transmission lines have proved the accuracy and effectiveness of the proposed algorithm.

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • 제3권4호
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.

시트와 바닥 진동의 위상차가 안락성에 미치는 영향을 평가하기 위한 수식의 제안 (Proposal of an Equation for the Evaluation of Discomfort of a Seated Human Body Due to the Differential Vertical Vibration at the Seat and the Floor)

  • 장한기
    • 한국소음진동공학회논문집
    • /
    • 제12권8호
    • /
    • pp.626-631
    • /
    • 2002
  • A modified equation for the evaluation of discomfort of a seated human body exposed to differential vibration at the seat and the floor was proposed in this paper. Through the review and analysis of the preceding studies, effect of phase difference between the seat and the floor vibration on discomfort were quantitatively identified. The phase effect was shown to be governed by not only phase difference between the two vibrations but both their frequency and the magnitude, which means the present equation for the evaluation of perceptual amount of vibration provided by ISO 2631-1 should be modified. The proposed equation was developed such that the correction function was multiplied to the present equation. The correction function consisted of three parts, each of them represented the effect by phase difference, frequency and vibration magnitude on discomfort respectively.

Rayleigh waves in orthotropic magneto-thermoelastic media under three GN-theories

  • Parveen Lata;Himanshi
    • Advances in materials Research
    • /
    • 제12권3호
    • /
    • pp.211-226
    • /
    • 2023
  • The present work is considered to study the two-dimensional problem in an orthotropic magneto-thermoelastic media and examined the effect of thermal phase-lags and GN-theories on Rayleigh waves in the light of fractional order theory with combined effect of rotation and hall current. The boundary conditions are used to derive the secular equations of Rayleigh waves. The wave properties such as phase velocity, attenuation coefficient are computed numerically. The numerical simulated results are presented graphically to show the effect of phase-lags and GN-theories on the Rayleigh wave phase velocity, attenuation coefficient, stress components and temperature change. Some particular cases are also discussed in the present investigation.

새로운 플루오라이트 구조 강유전체의 Electrocaloric Effect (Electrocaloric Effect in Emerging Fluorite-Structure Ferroelectrics)

  • 양건;박주용;이동현;박민혁
    • 한국재료학회지
    • /
    • 제30권9호
    • /
    • pp.480-488
    • /
    • 2020
  • The electrocaloric effect can be observed in pyroelectric materials based on conversion between electrical and thermal energy, and can be utilized for the future environment-friendly refrigeration technology. Especially, a strong electrocaloric effect is expected in materials in which field-induced phase transition can be achieved. Emerging fluorite-structure ferroelectrics such as doped hafnia and zirconia, first discovered in 2011, are considered the most promising materials for next-generation semiconductor devices. Besides application of fluorite-structure ferroelectrics for semiconductor devices based on their scalability and CMOS-compatibility, field-induced phase transition has been suggested as another interesting phenomenon for various energy-related applications such as solid-state cooling with electrocaloric effect as well as energy conversion/storage and IR/piezoelectric sensors. Especially, their giant electrocaloric effect is considered promising for solid-state-cooling. However, the electrocaloric effect of fluorite-structure oxides based on field-induced phase transition has not been reviewed to date. In this review, therefore, the electrocaloric effect accompanied by field-induced phase transition in fluorite-structure ferroelectrics is comprehensively reviewed from fundamentals to potential applications.

Effect of growth phase of cyanobacterium on release of intracellular geosmin from cells during microfiltration process

  • Matsushita, Taku;Nakamura, Keisuke;Matsui, Yoshihiko;Shirasaki, Nobutaka
    • Membrane and Water Treatment
    • /
    • 제6권3호
    • /
    • pp.225-235
    • /
    • 2015
  • During low-pressure membrane treatments of cyanobacterial cells, including microfiltration (MF) and ultrafiltration (UF), there have reportedly been releases of intracellular compounds including cyanotoxins and compounds with an earthy-musty odor into the water, probably owing to cyanobacterial cell breakage retained on the membrane. However, to our knowledge, no information was reported regarding the effect of growth phase of cyanobacterial cells on the release of the intracellular compounds. In the present study, we used a geosmin-producing cyanobacterium, Anabaena smithii, to investigate the effect of the growth phase of the cyanobacterium on the release of intracellular geosmin during laboratory-scale MF experiments with the cells in either the logarithmic growth or stationary phase. Separate detection of damaged and intact cells revealed that the extent of cell breakage on the MF membrane was almost the same for logarithmic growth and stationary phase cells. However, whereas the geosmin concentration in the MF permeate increased after 3 h of filtration with cells in the logarithmic growth phase, it did not increase during filtration with cells in the stationary phase: the trend in the geosmin concentration in the MF permeate with time was much different between the logarithmic growth and stationary phases. Adsorption of geosmin to algogenic organic matter (AOM) retained on the MF membrane and/or pore blocking with the AOM were greater when the cells were in the stationary phase versus the logarithmic growth phase, the result being a decrease in the apparent release of intracellular geosmin from the stationary phase cells. In actual drinking water treatment plants employing membrane processes, more attention should be paid to the cyanobacterial cells in logarithmic growth phase than in stationary phase from a viewpoint of preventing the leakage of intracellular earthy-musty odor compounds to finished water.

CARS를 이용한 희박 예혼합 가스터빈 연소기내 온도 측정 (I) -연료/공기 혼합정도가 위상별 온도에 미치는 영향- (Phase-Resolved CARS Temperature Measurement in a Lean Premixed Gas Turbine Combustor (I) -Effect of Equivalence Ratio on Phase-Resolved Gas Temperature-)

  • 이종호;전충환;박철웅;한재원;장영준
    • 대한기계학회논문집B
    • /
    • 제28권10호
    • /
    • pp.1184-1192
    • /
    • 2004
  • Experimental investigations were carried out in an atmospheric pressure, optically accessible and laboratory-scale dump combustor operating on methane gas. The objective of this study was to obtain the phase-resolved gas temperatures at different phases of the oscillating pressure cycle during unstable combustion. CARS temperature measurements were made at several spatial locations under lean premixed conditions to get the information on temperature field within the combustor. Also the effect of incomplete fuel-air mixing on phase-resolved temperature fluctuation was investigated. Results including phase-resolved averaged temperature, normalized standard deviation and temperature probability distribution functions (PDFs) were provided in this paper. Temperature PDFs gave an insight on the flame behavior. And strong correlation between phase-resolved temperature profile and pressure cycle was observed. Results of the phase-resolved high temperature gave an additional information on the perturbation of equivalence ratio at flame as well as the effect of mixing quality on NOx emission characteristics.

CARS를 이용한 희박 예혼합 가스터빈 연소기내 온도 측정(1);연료/공기 혼합정도가 위상별 온도에 미치는 영향 (Phase-resolved CARS Temperature Measurements in a Lean Premixed Gas Turbine Combustor;Effect of fuel/air mixing on phase-resolved gas temperature)

  • 문건필;이종호;박철웅;한재원;전충환;장영준
    • 한국연소학회:학술대회논문집
    • /
    • 대한연소학회 2003년도 제27회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.97-102
    • /
    • 2003
  • Experimental investigations were carried out in an atmospheric pressure, optically accessible and laboratory-scale dump combustor operating on natural gas. The objective of this study is to obtain the phase-resolved gas temperatures at different phases of the oscillating pressure cycle during unstable combustion. CARS temperature measurements were made at several spatial locations under lean premixed conditions to get the information on temperature field within the combustor. Also the effect of incomplete fuel-air mixing on phase-resolved temperature fluctuation was investigated. Results including phase-resolved averaged temperature, normalized standard deviation and temperature probability distribution functions (PDFs) were provided in this paper. Temperature PDFs give an insight on the flame behavior. And strong correlation between phase-resolved temperature profile and pressure cycle was observed. Results of the phase-resolved high temperature give an additional information on the perturbation of equivalence ratio at flame as well as the effect of mixing quality on NOx emission characteristics.

  • PDF