• Title/Summary/Keyword: Phase Comparison

Search Result 1,890, Processing Time 0.026 seconds

Research about ESPI System Algorithm Development that Use Modulating Laser (Modulating Laser를 이용한 ESPI System algorithm 개발에 관한 연구)

  • Kim, Seong-Jong;Kang, Young-June;Park, Nak-Kyu;Lee, Dong-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.7
    • /
    • pp.65-72
    • /
    • 2009
  • Laser interferometry is widely used as a measuring system in many fields because of its high resolution and its ability to measure a broad area in real-time all at once. In conventional laser interferometry, for example out-of-plane ESPI (Electronic Speckle Pattern Interferometry), in plane ESPI, shearography and holography, it uses PZT or other components as a phase shift instrumentation to extract 3-D deformation data, vibration mode and others. However, in most cases PZT has some disadvantages, which include nonlinear errors and limited time of use. In the present study, a new type of laser interferometry using a laser diode is proposed. Using Laser Diode Sinusoidal Phase Modulating (LD-SPM) interferometry, the phase modulation can be directly modulated by controlling the laser diode injection current thereby eliminating the need for PZT and its components. This makes the interferometry more compact. This paper reports on a new approach to the LD (Laser Diode) Modulating interferometry that involves four-frame phase shift method. This study proposes a four-frame phase mapping algorithm, which was developed to have a guaranteed application, to stabilize the system in the field and to be a user-friendly GUI. In this paper, the theory for LD wavelength modulation and sinusoidal phase modulation of LD modulating interferometry is shown. Using modulating laser and research of measurement algorithm does comparison with existent ESPI measurement algorithm. Algorithm measures using GPIB communication through most LabVIEW 8.2. GPIB communication does alteration through PC. Transformation of measurement object measures through modulating laser algorithm that develops. Comparison of algorithm of modulating laser developed newly with existent PZT algorithm compares transformation price through 3-D. Comparison of 4-frame phase mapping, unwrapping, 3-D is then introduced.

5-GHz Delay-Locked Loop Using Relative Comparison Quadrature Phase Detector

  • Wang, Sung-Ho;Kim, Jung-Tae;Hur, Chang-Wu
    • Journal of information and communication convergence engineering
    • /
    • v.2 no.2
    • /
    • pp.102-105
    • /
    • 2004
  • A Quadrature phase detector for high-speed delay-locked loop is introduced. The proposed Quadrature phase detector is composed of two nor gates and it determines if the phase difference of two input clocks is 90 degrees or not. The delay locked loop circuit including the Quadrature phase detector is fabricated in a 0.18 um Standard CMOS process and it operates at 5 GHz frequency. The phase error of the delay-locked loop is maximum 2 degrees and the circuits are robust with voltage, temperature variations.

Quantification and location damage detection of plane and space truss using residual force method and teaching-learning based optimization algorithm

  • Shallan, Osman;Hamdy, Osman
    • Structural Engineering and Mechanics
    • /
    • v.81 no.2
    • /
    • pp.195-203
    • /
    • 2022
  • This paper presents the quantification and location damage detection of plane and space truss structures in a two-phase method to reduce the computations efforts significantly. In the first phase, a proposed damage indicator based on the residual force vector concept is used to get the suspected damaged members. In the second phase, using damage quantification as a variable, a teaching-learning based optimization algorithm (TLBO) is used to obtain the damage quantification value of the suspected members obtained in the first phase. TLBO is a relatively modern algorithm that has proved distinguished in solving optimization problems. For more verification of TLBO effeciency, the classical particle swarm optimization (PSO) is used in the second phase to make a comparison between TLBO and PSO algorithms. As it is clear, the first phase reduces the search space in the second phase, leading to considerable reduction in computations efforts. The method is applied on three examples, including plane and space trusses. Results have proved the capability of the proposed method to precisely detect the quantification and location of damage easily with low computational efforts, and the efficiency of TLBO in comparison to the classical PSO.

Design and Fabrication of 2-Dimensional Direction Finding Receiver Using Phase Comparison (2차원 위상비교 방향탐지를 위한 수신기 설계 및 제작)

  • Jeon, Jonghwa;Jo, Sungjin;Chae, Myoungho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.52-58
    • /
    • 2020
  • In this paper, a 2-dimensional phase comparison direction finding receiver was designed and fabricated. For 2-D comparison direction finding, direction finding formulas were derived from a uniformly arranged of four antennas. Based on this, a direction finding receiver was designed using Matlab simulink, and the direction finding receiver was fabricated. To analyze the performance of the designed direction finding receiver, the injection direction finding accuracy and simulation results were compared. As a result of the test, the fabricated direction finding receiver showed a maximum of 3° RMS precision, and the result of both tests showed similar trends. Also, it was confirmed that the direction finding accuracy of elevation angle is about 2.7 times better than azimuth angle, and both models performed well within 0.7° RMS at the boresight.

Comparison of the harmonic reduction by using harmonic passive fitters and technique of intervene firing method at the pulse of the 6-pulse phase controlled converter.

  • Wongtongdee, Surached W.;Laohasongkram, Pipat
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.782-785
    • /
    • 2005
  • This article introduces technique to reduce harmonic by using the $5^{th}$ and $7^{th}$ harmonic tune filter and line reactor in the comparison to the technique of intervening firing method at the pulse of the 6-pulse phase-controlled converter in every 1/6 period. The design of the technique introduced in this article is to reduce the harmonic distortion of the current and the voltage resulted from three-phase thyristor phase-controlled converter. The waveform obtained from the experiment was analyzed on the spectrum of the current, voltage and the total harmonic distortion. The double firing method causes zero vectors of output voltage and input current. Designing the mechanism of the converter based on the idea of Park Vector Theory, the number of harmonic distortion in the intervening firing method were compared to those in normal firing method.

  • PDF

Approximated Solution of Model for Three-Phase Fluidized Bed Biofilm Reactor in Wastewater Treatment

  • Choi Jeong-Woo;Min Junhong;Lee Won-Hong;Lee Sang Baek
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.1
    • /
    • pp.65-70
    • /
    • 2000
  • An approximated analytical solution of mathematical model for the three phase fluidized bed bioreactor (TFBBR) was proposed using the linearization technique to describe oxygen utilization rate in wastewater treatment. The validation of the model was done in comparison with the experimental results. Satisfactory agreement was obtained in the comparison of approximated analytical solution and numerical solution in the oxygen concentration profile of a TFBBR. The approximated solutions for three modes of the liquid phase flow were compared. The proposed model was able to predict the biomass concentration, dissolved oxygen concentration the height of efficient column, and the removal efficiency.

  • PDF

The Research of Gait on Parkinson's Disease (파킨슨 환자의 보행에 관한 연구)

  • Chae, Jung-Byung;Cho, Hyun-Rae
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.4 no.4
    • /
    • pp.249-255
    • /
    • 2009
  • Purpose:To investigate of gait component in Parkinson's Disease patient. Methods:participated Parkinson's Disease patient(n=12) and Normal adult(n=13). gait measure used by GaitRite. Results:SPSS for win version 12 was used for statistic analysis and independent t-test used to find between two groups. In the comparison of temporal parameter of gait between groups, the swing phase was significant decreased in Parkinson's groups, in the stance phase was significant increased in Normal groups, in the single support was significant decreased in Parkinson's groups and in the double support was significant increased in Parkinson's groups(p<.05). In the asymmetrical ratio of singele support was significant increased in Parkinson's groups(p<.05), and the swing phase and stance phase was significant increased in Parkinson's groups(p<.05). Conclusion:In the Parkinson's Disease patient gait showed temporal and spatial component variable changes comparison normal adult. therefore, it was seems to very important considerable at gait tranning in clinical intervention.

  • PDF

The Comparison of PWM Converter's Topology in Electric Train (철도차량용 PWM 컨버터방식 비교)

  • 이현원;김남해
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.97-100
    • /
    • 1999
  • AC to DC single phase PWM converter for traction application requires rated high power and voltage. Therefor, series or parallel operation converters are necessary with considering the limitation of the power device specification. This paper compares the characteristic between two parallel operation of conventional PWM converter and Single phase three level converter about comparison of power circuit, cooling system control method and harmonic current by computer simulation.

  • PDF

Design of Digital Controller for Output Voltage Control of LC Filter in 3-Phase UPS (UPS용 인버터의 LC필터 출력 전압제어를 위한 디지털 제어기 설계)

  • 조준석;이승요;최규하;목형수;신우석;한석우
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.75-80
    • /
    • 1998
  • This paper presents an observer filter algorithm to estimated the load currents in the output voltage control of 3-phase uninterruptible power supply with deadbeat controller. As the result of the proposed algorithm, the sensors to measure the load currents is not required. The comparison of output voltage controls according to the methods of measuring the load currents is also presented in this paper. The results of comparison are shown by the simulation.

  • PDF

Evaluation Technique of Linearity of Ratio Error and Phase Angle Error of Voltage Transformer Comparison Measurement System Using Capacitor Burden (전기용량 부담을 이용한 전압변성기 비교 측정 시스템의 비오차 및 위상각 오차의 직선성 평가기술)

  • Jung Jae Kap;Kim Han Jun;Kwon Sung Won;Kim Myung Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.6
    • /
    • pp.274-278
    • /
    • 2005
  • Voltage transformer(VT) comparison measurement system is usually used for measurements of ratio error and phase angle error of VT made in industry. Both ratio error and phase angle error in VT are critically influenced by values of burden of VT used. External burden effects on both ratio error and phase angle error in VT are theoretically calculated. From the theoretical calculation, a method of evaluation for linearity of ratio error and phase angle error in VT measurement system have been developed using the standard capacitive burdens, with negligible dissipation factor less than 10$^{-4}$. These burden consists of five standard capacitors, with nominal capacitance of 1.1 $\mu$F, 1 $\mu$F, 0.1 $\mu$F, 0.01 $\mu$F, 0.001 $\mu$F. The developed method has been applied in VT measurement system of industry, showing in good consistency and linearity within 0.001 $\%$ between theoretical and measured values.