• Title/Summary/Keyword: Pet imaging

Search Result 668, Processing Time 0.023 seconds

ATAD2 expression increases [18F]Fluorodeoxyglucose uptake value in lung adenocarcinoma via AKT-GLUT1/HK2 pathway

  • Sun, Tong;Du, Bulin;Diao, Yao;Li, Xuena;Chen, Song;Li, Yaming
    • BMB Reports
    • /
    • v.52 no.7
    • /
    • pp.457-462
    • /
    • 2019
  • [18F]Fluorodeoxyglucose (FDG) PET/CT imaging has been widely used in the diagnosis of malignant tumors. ATPase family AAA domain-containing protein 2 (ATAD2) plays important roles in tumor growth, invasion and metastasis. However, the relationship between [18F]FDG accumulation and ATAD2 expression remains largely unknown. This study aimed to investigate the correlation between ATAD2 expression and [18F]FDG uptake in lung adenocarcinoma (LUAD), and elucidate its underlying molecular mechanisms. The results showed that ATAD2 expression was positively correlated with maximum standardized uptake value ($SUV_{max}$), total lesion glycolysis (TLG), glucose transporter type 1 (GLUT1) expression and hexokinase2 (HK2) expression in LUAD tissues. In addition, ATAD2 knockdown significantly inhibited the proliferation, tumorigenicity, migration, [18F]FDG uptake and lactate production of LUAD cells, while, ATAD2 overexpression exhibited the opposite effects. Furthermore, ATAD2 modulated the glycometabolism of LUAD via AKT-GLUT1/HK2 pathway, as assessed using LY294002 (an inhibitor of PI3K/AKT pathway). In summary, to explore the correlation between ATAD2 expression and glycometabolism is expected to bring good news for anti-energy metabolism therapy of cancers.

Recent Research Trend in Lateral Flow Immunoassay Strip (LFIA) with Colorimetric Method for Detection of Cancer Biomarkers (암 바이오마커 검출용 비색법 기반 측면 흐름 면역 크로마토그래피 분석법(LFIA) 스트립의 최신 연구 동향)

  • Lee, Sooyoung;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.31 no.6
    • /
    • pp.585-590
    • /
    • 2020
  • Successful early diagnosis of cancer diseases such as lung, prostate, liver and adrenocortical carcinoma is a key step in determining the cost of treatment, survival rate, and cure rate. Most of current cancer diagnosis systems including biopsy, computed tomography (CT), positron emission tomography (PET)-CT, magnetic resonance imaging (MRI), ultrasonography, etc., require expensive and complicated equipment with highly trained human resources. Global medical and scientific communities have thus made numerous efforts on developing effective but rapid disease management system via introducing a wide spectrum of point-of-care medical diagnosis devices. Among them, a lateral flow immunoassay strip technique has gained a great attention due to many advantages such as cost-effectiveness, short inspection time, and user friendly accessibility. In this mini-review, we will highlight recent research trend on the development of colorimetry based LFIA strips for cancer diagnosis and discuss the future research direction and potential applications.

Usefulness of Brain Phantom Made by Fused Filament Fabrication Type 3D Printer (적층 제조형 방식의 3D 프린터로 제작한 뇌 팬텀의 유용성)

  • Lee, Yong-Ki;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.43 no.6
    • /
    • pp.453-460
    • /
    • 2020
  • The price of the Brain phantom (Hoffman 3D brain phantom) used in nuclear medicine is quite expensive, it is difficult to be purchased by a medical institution or an educational institution. Therefore, the purpose of present research is to produce a low-price 3D brain phantom and evaluate its usefulness by using a 3D printer capable of producing 3D structures. The New 3D brain phantom consisted of 36 slices 0.7 mm thick and 58 slices 1.5 mm thick. A 0.7 mm thick slice was placed between 1. 5 mm thick slices to produce a composite slice. ROI was set at the gray matter and white matter scanned with CT to measure and compare the HU, in order to verify the similarity between PLA which was used as the material for the New 3D brain phantom and acrylic which was used as the material for Hoffman 3D brain phantom. As a result of measuring the volume of each Phantom, the error rate was 3.2% and there was no difference in the signal intensity in five areas. However, there was a significant difference in the average values of HU which was measured at the gray and white matter to verify the similarity between PLA and acrylic. By reproducing the previous Hoffman 3D brain phantom with a 100 times less cost, I hope this research could contribute to be used as the fundamental data in the areas of 3D printer, nuclear medicine and molecular imaging and to increasing the distribution rate of 3D brain phantom.

A Case Report of Traditional Korean Medicine-Based Integrative Oncology of Recurrent Cervical Cancer (재발된 자궁경부암 환자의 한의 기반 통합 암 치료에 대한 증례보고)

  • Joo, Han-eum;Park, Ji-hye;Song, Si-yeon;Cho, Young-min;Park, So-jeong;Yoo, Hwa-seung
    • The Journal of Internal Korean Medicine
    • /
    • v.43 no.4
    • /
    • pp.751-760
    • /
    • 2022
  • Objective: To show a decrease in tumor recurrence and improvement in quality of life in patients with recurrent cervical cancer. Method: A 58-year-old female patient diagnosed with recurrent cervical cancer in February 2021 was treated for 14 months with integrative cancer treatment (ICT) to decrease the tumor size and improve chemotherapy-induced peripheral neuropathy (CIPN) and nausea. The patient underwent chemotherapy or concomitant chemoradiation therapy (CCRT) with ICT. Radiologic outcomes were assessed by abdomen & pelvis computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography-computed tomography (PET-CT) based on the Response Evaluation Criteria in Solid Tumors (RECIST) protocol. Clinical outcomes were assessed by the National Cancer Institute Common Terminology Criteria for Adverse Event (NCI-CTCAE), Eastern Cooperative Oncology Group (ECOG), and a numeric rating scale (NRS). Result: During the 14 months of treatment, the size and metabolic activity of the recurrent tumor decreased and underwent partial remission based on RECIST. The NRS scores for CIPN and nausea were improved, and the ECOG score improved from grade 2 to 1. No serious side effects of grade 3 or higher were noted on the NCI-CTCAE test. Conclusion: This case suggests that ICT may have a synergetic effect with chemotherapy or radiotherapy for recurrent cervical cancer.

Validation of the production quality and therapeutic efficacy of 47Sc through its anti-cancer effects against EGFR-targeted non-small cell lung cancer

  • Da-Mi Kim;So-Young Lee;Jae-Cheong Lim;Eun-Ha Cho;Ul-Jae Park
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.1
    • /
    • pp.9-15
    • /
    • 2022
  • Anti-cancer and therapeutic effects using therapeutic radioisotopes have been demonstrated by various studies, and it is well-known that therapeutic radioisotopes are useful in cancer treatment. Recently, one of the therapeutic radioisotopes, scandium is emerging as a radioisotope applicable to PET imaging (43Sc, 44Sc) and therapy (47Sc) in cancer theranostic approach. However, 47Sc has little known radiobiological and therapeutic efficacy compared to other therapeutic radioisotopes. Here, we investigated the quality and therapeutic efficacy of 47Sc radioisotope produced by our production/isolation technology at the research reactor 'HANARO' in KAERI (Korea Atomic Energy Research Institute). We showed that the therapeutic efficacy of 47Sc, produced by our production/isolation technology, effectively suppressed epidermal growth factor receptor (EGFR)-targeted non-small cell lung cancer (NSCLC) cells. Consequently, these results suggest that the high quality of the produced 47Sc by our production/isolation technology enables the development of therapeutic strategies for cancer treatment and radiopharmaceuticals using 47Sc.

Optimized production method of [18F]flortaucipir injection for imaging tau pathology in patients with Alzheimer's disease

  • Kyung Rok Nam;Sang Jin Han;Nam Hun Lee;Min Yong Lee;Youngduk Kim;Kyo Chul Lee;Yong Jin Lee;Young Hoon Ryu;Jae Yong Choi
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.6 no.2
    • /
    • pp.61-68
    • /
    • 2020
  • Aggregated neurofibrillary tangles (NFTs) are a pathological hallmark in Alzheimer's disease (AD) and many radiopharmaceuticals targeting NFTs have been developed so far. Among these, [18F]flortaucipir (TAUVIDTM) is the first approved radiopharmaceutical in the Food and Drug Administration (FDA) to image tau pathology. In the present study, we describe the optimized radiosynthetic method for the routine production of [18F] flortaucipir using a commercialized automation module (i.e. GE TRACERlabTM FXFN pro). [18F]Flortaucipir was prepared by nucleophilic substitution from its N-tert-butoxycarbonyl protected nitro precursor, tertbutyl 7-(6-nitropyridin-3-yl)-5H-pyrido[4,3-b]indole-5-carboxylate, at 130℃ for 10 min in dimethyl sulfoxide. The mean radiochemical yield was 20 ± 4.3% (decay-corrected, n = 47) with the molar activity of 218 ± 32 GBq/µmol at the end of synthesis. The radiochemical purity was determined to be above 95%. The overall production time including quality control is approximately 100min. The final produced [18F]flortaucipir injection meets the USP criteria for quality control. Thus, this fully automated system is validated for clinical use.

The Application of Radiolabeled Targeted Molecular Probes for the Diagnosis and Treatment of Prostate Cancer

  • Luyi Cheng;TianshuoYang;Jun Zhang;Feng Gao;Lingyun Yang;Weijing Tao
    • Korean Journal of Radiology
    • /
    • v.24 no.6
    • /
    • pp.574-589
    • /
    • 2023
  • Radiopharmaceuticals targeting prostate-specific membrane antigens (PSMA) are essential for the diagnosis, evaluation, and treatment of prostate cancer (PCa), particularly metastatic castration-resistant PCa, for which conventional treatment is ineffective. These molecular probes include [68Ga]PSMA, [18F]PSMA, [Al18F]PSMA, [99mTc]PSMA, and [89Zr]PSMA, which are widely used for diagnosis, and [177Lu]PSMA and [225Ac]PSMA, which are used for treatment. There are also new types of radiopharmaceuticals. Due to the differentiation and heterogeneity of tumor cells, a subtype of PCa with an extremely poor prognosis, referred to as neuroendocrine prostate cancer (NEPC), has emerged, and its diagnosis and treatment present great challenges. To improve the detection rate of NEPC and prolong patient survival, many researchers have investigated the use of relevant radiopharmaceuticals as targeted molecular probes for the detection and treatment of NEPC lesions, including DOTA-TOC and DOTA-TATE for somatostatin receptors, 4A06 for CUB domain-containing protein 1, and FDG. This review focused on the specific molecular targets and various radionuclides that have been developed for PCa in recent years, including those mentioned above and several others, and aimed to provide valuable up-to-date information and research ideas for future studies.

The Influence of Iteration and Subset on True X Method in F-18-FPCIT Brain Imaging (F-18-FPCIP 뇌 영상에서 True-X 재구성 기법을 기반으로 했을 때의 Iteration과 Subset의 영향)

  • Choi, Jae-Min;Kim, Kyung-Sik;NamGung, Chang-Kyeong;Nam, Ki-Pyo;Im, Ki-Cheon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.122-126
    • /
    • 2010
  • Purpose: F-18-FPCIT that shows strong familiarity with DAT located at a neural terminal site offers diagnostic information about DAT density state in the region of the striatum especially Parkinson's disease. In this study, we altered the iteration and subset and measured SUV${\pm}$SD and Contrasts from phantom images which set up to specific iteration and subset. So, we are going to suggest the appropriate range of the iteration and subset. Materials and Methods: This study has been performed with 10 normal volunteers who don't have any history of Parkinson's disease or cerebral disease and Flangeless Esser PET Phantom from Data Spectrum Corporation. $5.3{\pm}0.2$ mCi of F-18-FPCIT was injected to the normal group and PET Phantom was assembled by ACR PET Phantom Instructions and it's actual ratio between hot spheres and background was 2.35 to 1. Brain and Phantom images were acquired after 3 hours from the time of the injection and images were acquired for ten minutes. Basically, SIEMENS Bio graph 40 True-point was used and True-X method was applied for image reconstruction method. The iteration and Subset were set to 2 iterations, 8 subsets, 3 iterations, 16 subsets, 6 iterations, 16 subsets, 8 iterations, 16 subsets and 8 iterations, 21 subsets respectively. To measure SUVs on the brain images, ROIs were drawn on the right Putamen. Also, Coefficient of variance (CV) was calculated to indicate the uniformity at each iteration and subset combinations. On the phantom study, we measured the actual ratio between hot spheres and back ground at each combinations. Same size's ROIs were drawn on the same slide and location. Results: Mean SUVs were 10.60, 12.83, 13.87, 13.98 and 13.5 at each combination. The range of fluctuation by sets were 22.36%, 10.34%, 1.1%, and 4.8% respectively. The range of fluctuation of mean SUV was lowest between 6 iterations 16 subsets and 8 iterations 16 subsets. CV showed 9.07%, 11.46%, 13.56%, 14.91% and 19.47% respectively. This means that the numerical value of the iteration and subset gets higher the image's uniformity gets worse. The range of fluctuation of CV by sets were 2.39, 2.1, 1.35, and 4.56. The range of fluctuation of uniformity was lowest between 6 iterations, 16 subsets and 8 iterations, 16 subsets. In the contrast test, it showed 1.92:1, 2.12:1, 2.10:1, 2.13:1 and 2.11:1 at each iteration and subset combinations. A Setting of 8 iterations and 16 subsets reappeared most close ratio between hot spheres and background. Conclusion: Findings on this study, SUVs and uniformity might be calculated differently caused by variable reconstruction parameters like filter or FWHM. Mean SUV and uniformity showed the lowest range of fluctuation at 6 iterations 16 subsets and 8 iterations 16 subsets. Also, 8 iterations 16 subsets showed the nearest hot sphere to background ratio compared with others. But it can not be concluded that only 6 iterations 16 subsets and 8 iterations 16 subsets can make right images for the clinical diagnosis. There might be more factors that can make better images. For more exact clinical diagnosis through the quantitative analysis of DAT density in the region of striatum we need to secure healthy people's quantitative values.

  • PDF

Difference in F-18 FDG Uptake According to the Patterns of CT-Based Diagnosed Pulmonary Lymphangitic Carcinomatosis in Patients with Lung Cancer (폐암환자에 있어 CT상으로 진단된 폐림프관성암종증의 형태에 따른 F-18 FDG 섭취의 차이)

  • Jun, Sung-Min;Kim, Yong-Ki;Kim, In-Ju;Kim, Seong-Jang;Nam, Hyun-Yeol;Kim, Bum-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.292-300
    • /
    • 2008
  • Purpose: Our purpose was to evaluate F-18 FDG uptake in pulmonary lymphangitic carcinomatosis (PLC) according to CT findings and histology of lung cancer. Materials and Methods: Thirty-three lung cancer patients with PLC were enrolled in this retrospective study. All the patients had a CT-based diagnosis of PLC. Chest CT findings of PLC were classified on the basis of involvement of axial interstitium. We categorized the involvement of axial interstitium as group 1, and the involvement of peripheral interstitium only as group 2. Visual and semiquantitative analyses by F-18 FDG PET/CT were performed in the PLC lesions. At first, we analyzed the F-18 FDG uptake in the PLC by visual assessment. If abnormal uptake was seen in the PLC, we drew regions of interest in the PLC lesions to obtain the maximum SUVs (maxSUVs). Results: Of the 33 patients, 22 had abnormal F-18 FDG uptake in the visual assessment. There was no significant difference in the frequency of abnormal F-18 FDG uptake between group 1 and group 2 (p=0.17), although the frequency of group 1 tended to be higher than group 2 (15/19 (78.9%) in group 1, 7/14 (50.0%) in group 2). However, group 1 had a higher maxSUV than group 2 (p<0.01, group 1: $2.9{\pm}1.4$, group 2: $1.5{\pm}0.6$). There was no significant difference in the frequency of abnormal F-18 FDG uptake and maxSUV among the histology of the lung cancers. Conclusion: The involvement of axial interstitium in the PLC by lung cancer has a higher maxSUV than the involvement of only peripheral interstitium.

Performance Evaluation of Reconstruction Algorithms for DMIDR (DMIDR 장치의 재구성 알고리즘 별 성능 평가)

  • Kwak, In-Suk;Lee, Hyuk;Moon, Seung-Cheol
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.29-37
    • /
    • 2019
  • Purpose DMIDR(Discovery Molecular Imaging Digital Ready, General Electric Healthcare, USA) is a PET/CT scanner designed to allow application of PSF(Point Spread Function), TOF(Time of Flight) and Q.Clear algorithm. Especially, Q.Clear is a reconstruction algorithm which can overcome the limitation of OSEM(Ordered Subset Expectation Maximization) and reduce the image noise based on voxel unit. The aim of this paper is to evaluate the performance of reconstruction algorithms and optimize the algorithm combination to improve the accurate SUV(Standardized Uptake Value) measurement and lesion detectability. Materials and Methods PET phantom was filled with $^{18}F-FDG$ radioactivity concentration ratio of hot to background was in a ratio of 2:1, 4:1 and 8:1. Scan was performed using the NEMA protocols. Scan data was reconstructed using combination of (1)VPFX(VUE point FX(TOF)), (2)VPHD-S(VUE Point HD+PSF), (3)VPFX-S (TOF+PSF), (4)QCHD-S-400((VUE Point HD+Q.Clear(${\beta}-strength$ 400)+PSF), (5)QCFX-S-400(TOF +Q.Clear(${\beta}-strength$ 400)+PSF), (6)QCHD-S-50(VUE Point HD+Q.Clear(${\beta}-strength$ 50)+PSF) and (7)QCFX-S-50(TOF+Q.Clear(${\beta}-strength$ 50)+PSF). CR(Contrast Recovery) and BV(Background Variability) were compared. Also, SNR(Signal to Noise Ratio) and RC(Recovery Coefficient) of counts and SUV were compared respectively. Results VPFX-S showed the highest CR value in sphere size of 10 and 13 mm, and QCFX-S-50 showed the highest value in spheres greater than 17 mm. In comparison of BV and SNR, QCFX-S-400 and QCHD-S-400 showed good results. The results of SUV measurement were proportional to the H/B ratio. RC for SUV is in inverse proportion to the H/B ratio and QCFX-S-50 showed highest value. In addition, reconstruction algorithm of Q.Clear using 400 of ${\beta}-strength$ showed lower value. Conclusion When higher ${\beta}-strength$ was applied Q.Clear showed better image quality by reducing the noise. On the contrary, lower ${\beta}-strength$ was applied Q.Clear showed that sharpness increase and PVE(Partial Volume Effect) decrease, so it is possible to measure SUV based on high RC comparing to conventional reconstruction conditions. An appropriate choice of these reconstruction algorithm can improve the accuracy and lesion detectability. In this reason, it is necessary to optimize the algorithm parameter according to the purpose.