• Title/Summary/Keyword: Pet imaging

Search Result 663, Processing Time 0.027 seconds

A Study on Availability about Positron Emission Mammography of Breast Cancer (유방암 환자의 Positron Emission Mammography에서의 유용성에 관한 연구)

  • Kim, Seung-Jeong;Kim, Jae-Il;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.60-64
    • /
    • 2010
  • Purpose: Until now the general study for breast cancer patient has been mammography, breast sonography for anatomic diagnostics and $^{18}F$-FDG whole body PET for functional one. But the PEM (Positron Emission Mammography) was developed to increase sensitivity, specificity and accuracy to improve the disadvantage of each study. Therefore this present study aims to describe availability of PEM for improving diagnosis of breast cancer. Materials and Methods: During 3 months from January in 2010, PEM was performed on 100 patients who had history of breast cancer. Using Naviscan's PEM Flex Solo II scanner, PEM images of breast were acquired. And then we evaluated sensitivity, specificity and accuracy of PEM data by comparing results of PEM images with postoperative pathologic finding. Results: On the 100 patients, it could reveal 89 true positive, 9 false positive, 7 false negative and 87 true negative. Thus the results of sensitivity, specificity and accuracy for PEM was evaluated 92.7%, 90.6% and 91.7%. Conclusion: The sensitivity, specificity and accuracy have been reported 83.7%, 68.5% and 77.1% in mammography, and that was 89.1%, 79.1% and 83.4% in breast sonography. However the results of PEM were more increased than others. Therefore the results of this study will be available that PEM used diagnosis with breast cancer, used preoperative operation plan and helps to discovery of a part recurrence.

  • PDF

Positron Emission Tomography with $^{18}F-FDG$ Fluorodeoxyglucose for Primary Lymphoma of Bone (뼈에 발생한 악성 림프종 환자의 치료 효과 판정에서 $^{18}F-FDG$ Positron Emission Tomography의 유용성)

  • Kim, Nam-Don;Park, Yeon-Hee;Ki, Seung-Seog;Park, Yong-Jin;Kim, Heoyng-Joon;Ryoo, Baek-Yeol;Kim, Heung-Tae;Kim, Sung-Eun;Cheon, Gi-Jeong;Choi, Chang-Woon;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.5
    • /
    • pp.331-335
    • /
    • 2003
  • Purpose: Accurate assessment of the lesion after treatment of patients with bone lymphoma is difficult. In this patient who demonstrated complete remission after chemotherapy, the regions of fluorine-18 fluorodeoxyglucose $(^{18}FFDG)PET$ uptake diminished more rapidly fellowing therapy, indicating a complete response at much earlier stage than did Magnetic Resonance Imaging (MRI) or CT based findings. With the conventional methods, such as MRI and CT, It was difficult to assess whether the residual tumor tissue was viable or not. Decision to complete response is very important in patients with lymphoma to plan the further treatment. We experienced a patient with primary lymphoma of bone who revealed complete response to chemotherapy on $^{18}FFDGPET$ while CT showed persistent destructive bone lesion. Thus, $^{18}FFDGPET$ study after therapy may be superior to CT in the evaluation of response to treatment in primary lymphoma of bone.

Design of a Depth Encoding Detector using Light Guides with Different Reflector Patterns for Each Layer (각 층별 반사체 패턴이 서로 다른 광가이드를 사용한 반응 깊이 측정 검출기 설계)

  • Seung-Jae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.31-36
    • /
    • 2023
  • Among imaging and treatment devices for small animals, positron emission tomography(PET) causes a change in spatial resolution within a field of view. This is a phenomenon caused by using a small gantry and a thin and long scintillation pixel, and detectors that measure the interaction depth are being developed and researched to solve this problem. In this study, a detector that measures the interaction depth was designed using several scintillator blocks and light guides with different reflector patterns. The scintillator block composed of 4 × 4 arrays of 3 mm × 3 mm × 5 mm scintillation pixels formed four layers, and a light guide was inserted in each layer to configure the entire detector. In order to check whether the interaction depth was measured, a gamma ray interaction was generated at the center of all scintillation pixels to acquire data and then reconstructed into a flood image. The reflector patterns of the light guides inserted between the layers were all different, so the positions of the scintillation pixels for each layer were formed in different locations. It is considered that even spatial resolution can be achieved over all regions of the field of view if all positions of the scintillation pixels thus formed are separated and used for image reconstruction.

Development of an exclusive column method for 82Sr/82Rb generator using a 100 MeV proton linear accelerator of KOMAC

  • Kye-Ryung Kim;Yeong Su Ha;Sang-Pil Yoon;Yeon-ji Lee;Yong-Sub Cho;Hyeongi Kim;Sang-Jin Han;Jung Young Kim;Kyo Chul Lee;Jin Su Kim
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.7 no.2
    • /
    • pp.119-125
    • /
    • 2021
  • 82Sr for 82Rb generator was produced through the irradiation of the proton beam on the nat.RbCI target at the target irradiation facility installed at the end of the Rl-dedicated beamline of the 100 MeV proton linear accelerator of KOMAC (Korea Multi-purpose Accelerator Complex). The average current of the proton beam was 1.2 µA for irradiation time of 150 min. For the separation and purification of the 82Sr from nat.RbCI irradiated, Chelex-100 resin was used. The activities of 82Sr in the irradiated nat.RbCI target solution and after purification were 45.29 µCi and 43.4 µCi, respectively. The separation and purification yield was 95.8%. As an adsorbent to be filled in the generator for 82Sr adsorption hydrous tin oxide was selected. The adsorption yield of 82Sr into the generator adsorbent was > 99 %, and the total amount of 82Sr adsorbed to the generator was 21.6 µCi as of the day of the 82Rb elution experiment. When the elution amount was 22 mL, the maximum82Rb elution yield was 93.3%, and the elution yield increased as the flow rate increased. After the eluted 82Rb was filled in the correction phantom of the small PET for animals, a PET image was taken. The image scan time was set to 5 min, and the phantom PET image was successfully obtained. As results of impurity analysis on eluted 82Rb using ICP-MS, nat.Rb stable isotopes that compete in vivo of 82Rb were identified as undetected levels and were determined to be No-Carrier-Added (NCA).

Distinguishing between Thymic Epithelial Tumors and Benign Cysts via Computed Tomography

  • Sang Hyup Lee;Soon Ho Yoon;Ju Gang Nam;Hyung Jin Kim;Su Yeon Ahn;Hee Kyung Kim;Hyun Ju Lee;Hwan Hee Lee;Gi Jeong Cheon;Jin Mo Goo
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.671-682
    • /
    • 2019
  • Objective: To investigate whether computed tomography (CT) and fluorine-18-labeled fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) may be applied to distinguish thymic epithelial tumors (TETs) from benign cysts in the anterior mediastinum. Materials and Methods: We included 262 consecutive patients with pathologically proven TETs and benign cysts 5 cm or smaller who underwent preoperative CT scans. In addition to conventional morphological and ancillary CT findings, the relationship between the lesion and the adjacent mediastinal pleura was evaluated qualitatively and quantitatively. Mean lesion attenuation was measured on CT images. The maximum standardized uptake value (SUVmax) was obtained with FDG-PET scans in 40 patients. CT predictors for TETs were identified with multivariate logistic regression analysis. For validation, we assessed the diagnostic accuracy and inter-observer agreement between four radiologists in a size-matched set of 24 cysts and 24 TETs using a receiver operating characteristic curve before and after being informed of the study findings. Results: The multivariate analysis showed that post-contrast attenuation of 60 Hounsfield unit or higher (odds ratio [OR], 12.734; 95% confidence interval [CI], 2.506-64.705; p = 0.002) and the presence of protrusion from the mediastinal pleura (OR, 9.855; 95% CI, 1.749-55.535; p = 0.009) were the strongest CT predictors for TETs. SUVmax was significantly higher in TETs than in cysts (5.3 ± 2.4 vs. 1.1 ± 0.3; p < 0.001). After being informed of the study findings, the readers' area under the curve improved from 0.872-0.955 to 0.949-0.999 (p = 0.066-0.149). Inter-observer kappa values for protrusion were 0.630-0.941. Conclusion: Post-contrast CT attenuation, protrusion from the mediastinal pleura, and SUVmax were useful imaging features for distinguishing TETs from cysts in the anterior mediastinum.

The Parathyroid Gland: An Overall Review of the Hidden Organ for Radiologists (부갑상선: 부갑상선 영상에 익숙하지 않은 영상의학과 의사들을 위한 전반적인 검토)

  • Suho Kim;Jung Hee Shin;Soo Yeon Hahn;Haejung Kim;Myoung Kyoung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.327-344
    • /
    • 2024
  • Parathyroid glands are small endocrine glands that regulate calcium metabolism by producing parathyroid hormone (PTH). These are located at the back of the thyroid gland. Typically, four glands comprise the parathyroid glands, although their numbers may vary among individuals. Parathyroid diseases are related to parathyroid gland dysfunction and can be caused by problems with the parathyroid gland itself or abnormal serum calcium levels arising from renal disease. In recent years, as comprehensive health checkups have become more common, abnormal serum calcium levels are often found incidentally in blood tests, after which several additional tests, including a PTH test, ultrasonography (US), technetium-99m sestamibi parathyroid scan, single-photon-emission CT (SPECT)/CT, four-dimensional CT (4D-CT), and PET/CT, are performed for further evaluation. However, the parathyroid gland remains an organ less familiar to radiologists. Therefore, the normal anatomy, pathophysiology, imaging, and clinical findings of the parathyroid gland and its associated diseases are discussed here.

Multicentric Epithelioid Angiosarcoma of Bones Showing Angiotropic Spread: A Case Report (뼈에 발생한 혈관성 파종 양상을 보이는 다발성 상피상 혈관육종: 증례 보고)

  • Woo Suk Choi;Seul Ki Lee;Jee-Young Kim;Jun-Ho Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.240-246
    • /
    • 2024
  • Epithelioid angiosarcoma is a rare variant of angiosarcoma characterized by an epithelioid morphology that mimics carcinoma. Therefore, multicentric epithelioid angiosarcoma is easily misdiagnosed as bone metastasis from carcinoma and has an aggressive clinical course. Here, we present a rare case of a 61-year-old male with multicentric epithelioid angiosarcoma of the bone. Plain radiography, CT, and MRI revealed multiple osteolytic lesions in both femurs; some lesions showed soft tissue extension with cortical bone destruction. Interestingly, PET-CT revealed that the lesions were only distributed along the bones of the lower extremities, including the pelvic bones, femurs, and tibiae. Despite histological analysis initially suggesting metastatic carcinoma, after additional immunohistological staining, including that for vascular markers (CD31 and ERG), the final diagnosis was epithelioid angiosarcoma. A better understanding of the clinicoradiological features of this disease may help eliminate diagnostic confusion and provide better management.

Novel 99mTc(CO)3 Complexes with WAY-100635 Moiety for the Development of 5-HT1A Receptor lmaging Agent

  • Choi, Kang-Hyuk;Pyun, Mi-Sun;Hong, Young-Don;Choi, Sun-ju
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.1107-1112
    • /
    • 2009
  • The aim of this study is to develop and synthesize $5-HT_{1A}$ receptor imaging agents with WAY-100635 moiety and $^{99m}Tc(CO)_3$ core. WAY-100635 is commonly known as $5-HT_{1A}$ antagonist and its labeled compound ([$^{11}C$] WAY-100635) has been used as effective radioligand for imaging brain $5-HT_{1A}$ receptors with PET(Positron Emission Tomography). However, there are several restrictions in using a radioisotope of C-11 and requires for more effective radioisotopes and ligands. In order to produce a structure most similar to WAY-100635, WAY-100635 derivatives containing a cysteine chelator were designed and confirmed by using in silico (Hyperchem). The novel compounds (7a, 7b, 7c) were prepared in five or 7 steps with yields of 16%, 36% and 42%, respectively and radiolabeled with $[^{99m}Tc(CO)_3(H_2O)_3]^{+}$. The labeling yield was 99% for all the newly synthesized compounds. [$^{99m}Tc(CO)_3$]- WAY-100635 derivatives show a neutral charge which were confirmed by paper electrophoresis.

Cancer of Unknown Primary Site Mimicking Retroperitoneal Fibrosis (후복막강섬유화증으로 오인된 원발 부위 불명암 1예)

  • Park, Chan Keol;Yoo, Su-Jin;Yoo, In Seol;Kim, Jinhyun;Shim, Seung Cheol;Yeo, Min-kyung;Kang, Seong Wook
    • The Korean Journal of Medicine
    • /
    • v.93 no.6
    • /
    • pp.575-581
    • /
    • 2018
  • Retroperitoneal fibrosis (RPF) is a rare disease characterized by marked fibro-inflammatory tissue in the retroperitoneum. Approximately 70% of cases of RPF are idiopathic, while the rest can be secondary to several other causes. The diagnosis is mainly obtained by imaging modalities such as computed tomography (CT). However, histological examination should be considered when the clinical manifestations and imaging studies suggest malignancy. In particular, in malignant diseases with retroperitoneal metastases, abnormal collagen plaques are formed from an exuberant desmoplastic response, which may not be distinguishable from RPF on CT scans. Therefore, even if CT suggests RPF, biopsy is essential to identify malignant disease because it typically results in a fatal prognosis. Here, we report a case of metastatic adenocarcinoma of unknown primary site that developed only in the retroperitoneum and was initially diagnosed as RPF based on CT findings.

Application of sigmoidal optimization to reconstruct nuclear medicine image: Comparison with filtered back projection and iterative reconstruction method

  • Shin, Han-Back;Kim, Moo-Sub;Law, Martin;Djeng, Shih-Kien;Choi, Min-Geon;Choi, Byung Wook;Kang, Sungmin;Kim, Dong-Wook;Suh, Tae Suk;Yoon, Do-Kun
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.258-265
    • /
    • 2021
  • High levels for noise and a loss of true signal make the quantitative interpretation of nuclear medicine (NM) images difficult. An application of profile optimization using a sigmoidal function in this study was used to acquire the NM images with high quality. And the images were acquired by using three kinds of reconstruction method using each same sinogram: a standard filtered back-projection (FBP), an iterative reconstruction (IR) technique, and the sigmoidal function profile optimization (SFPO). Comparison of image according to reconstruction method was performed to show a superiority of the SFPO for imaging. The images reconstructed by using the SFPO showed an average of 1.49 times and of 1.17 times better in contrast than the results obtained using the standard FBP and the IR technique, respectively. Higher signal to noise ratios were obtained as an average of 12.30 times and of 3.77 times than results obtained using the standard FBP and the IR technique, respectively. This study confirms that reconstruction with SFPO (vs FBP and vs IR) can lead to better lesion detectability and characterization with noise reduction. It can be developed for future reconstruction technique for the NM imaging.