• 제목/요약/키워드: Personal health device

검색결과 119건 처리시간 0.024초

IT관점의 병원혁신 사례 (Cases of IT Based Innovation in a Hospital)

  • 황인정
    • 한국병원경영학회지
    • /
    • 제spc호
    • /
    • pp.74-84
    • /
    • 2016
  • This research is for an innovative health information service cases based on Information Communication Technology (ICT), conducted at a general hospital in Korea. This study introduces a personal use self-diagnosis & self management device for pulmonary chronic disease patients, a mobile communication application service for doctor rounds, a surgical education system providing natural-user-interface with virtual reality for surgeons, and an Internet of things(IOT) technology using personal electrocardiogram (ECG) measurement device cases. Due to every case is on developing, there are still many issues needed to be improved. For this reason, various opinions with constructive critiques from the readers of this paper will be welcomed for better practical implementation.

u-헬스 환경에서 개인건강관리를 위한 보안 위협 및 요구사항에 관한 연구 (Study on Security Threat and Requirement for Personal Health Management in u-Health Environment)

  • 김순석;박홍진
    • 한국항행학회논문지
    • /
    • 제14권4호
    • /
    • pp.504-511
    • /
    • 2010
  • 개인건강관리를 위해 PHD(Personal Health Device)로 부터 제공되는 개인 생체정보는 사생활 보호 측면에서 볼 때 개인의 생체와 관련한 매우 민감한 정보이며 환자를 가정할 때, 이것이 제 3자에게 노출되는 경우는 더욱 심각하다. 그러나 이번에 ISO에서 제정된 표준 프로토콜[1]의 경우, 개채 상호간에 생체 정보 교환을 위한 전송 부분만을 고려한 규격일 뿐 보안에 대한 요소는 전혀 고려되고 있지 않은 실정이다. 따라서 본 논문에서는 u-헬스 환경에서 개인건강관리를 위한 각종 보안 위협과 보안 요구사항에 대해 새롭게 제안하고자 한다.

IEEE 11073 개인건강기기별 표준 현황 및 분석 (Present Status and Analysis for IEEE 11073 Personal Health Device Specializations)

  • 박한나;김승환;유돈식
    • 한국통신학회논문지
    • /
    • 제37권6C호
    • /
    • pp.469-475
    • /
    • 2012
  • 평균수명연장과 건강에 대한 관심 증가는 언제 어디서나 서비스 가능한 유헬스 산업을 활성화시키고 있으며, 표준화 역시 여러 국제표준기구를 통해 다뤄지고 있다. 그 중 IEEE 11073 PHD(Personal Health Devices) WG은 개인건강기기와 관리기기의 상호운용성 보장을 위해 개인건강기기 통신 프로토콜에 대한 표준화 작업을 진행하고 있다. 그동안 개인건강기기 기본 표준인 IEEE 11073-20601에 대한 분석과 유헬스 표준화 단체에 대한 연구는 많이 있었으나 개인건강기기별 표준에 대한 분석은 부족하여 해당 표준에 접근하는데 많은 어려움이 있었다. 따라서 본 논문에서는 개인건강기기 관련 국내외 표준화 기구와 현재 IEEE 11073 PHD WG에서 다뤄지는 표준화 현황을 언급하고 IEEE 11073-20601를 바탕으로 체온계, 체중계, 혈당계, 혈압계, 심전계 등 각 개인건강기기별 표준의 특징을 분석하였다.

Privacy-Preserving IoT Data Collection in Fog-Cloud Computing Environment

  • Lim, Jong-Hyun;Kim, Jong Wook
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권9호
    • /
    • pp.43-49
    • /
    • 2019
  • Today, with the development of the internet of things, wearable devices related to personal health care have become widespread. Various global information and communication technology companies are developing various wearable health devices, which can collect personal health information such as heart rate, steps, and calories, using sensors built into the device. However, since individual health data includes sensitive information, the collection of irrelevant health data can lead to personal privacy issue. Therefore, there is a growing need to develop technology for collecting sensitive health data from wearable health devices, while preserving privacy. In recent years, local differential privacy (LDP), which enables sensitive data collection while preserving privacy, has attracted much attention. In this paper, we develop a technology for collecting vast amount of health data from a smartwatch device, which is one of popular wearable health devices, using local difference privacy. Experiment results with real data show that the proposed method is able to effectively collect sensitive health data from smartwatch users, while preserving privacy.

의료정보 표준에 기반 한 m-Health 어플리케이션 개발 (Development of m-Health Application based on Medical Informatics Standards)

  • 박현상;김화선;정현정;조훈
    • 한국멀티미디어학회논문지
    • /
    • 제17권5호
    • /
    • pp.640-653
    • /
    • 2014
  • Recently medical consumers pursue high leveled quality of life through active promotion, prevention, management activity of health as the importance of health during home life is emerged to meet the aging society and chronic diseases. In addition, people are directed to the m-Health for managing yourself their health by using smartphone and various personal health devices, if necessary transmits health data to the physician himself. In the previous studies, m-Health Application were developed and applied in the real clinical environment by adopting the medical information standards was rarely conducted. Therefore, in this study, the m-Health application platform was developed. Developed application was communicate with IEEE 11073 standard protocol using the Bluetooth Health Device Profile in personal health device via smart phone to process blood pressure information, and it converted to HL7 V2.6 ORU_R01 message for send to remote medical server. In addition, we tested the interoperability and safety of the developed application for 23 inpatient and 17 outpatient at D University Hospital. As a result, the blood pressure information has been transmitted without error.

Energy Efficient Wireless Data Transmission for Personal Health Devices

  • Kim, Sang-Kon;Kim, Tae-Kon;Koh, Jin-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1559-1570
    • /
    • 2013
  • The family of ISO/IEEE11073 standards is the basis of the e-health system and provides interoperability for personal health devices. In the early stage of e-health business, it was expected that people would use a health device individually. In this case, a measurement datum was episodically acquired and generally transmitted for one person at a time. Recently, a health device is expected to be used by multiple people, and large amounts of measurement data are gathered in a short time interval. In addition, mobile health devices have become more popular, so that energy efficient measurement data transmission is required, to prolong the use of a device. In IEEE11073 PHD standards, data transmission is classified into three different types: immediate individual transfer, small block transfer, and large block transfer. The large block transfer using PM-store concept provides efficient transmission. However, an existing PM-store has problem when a device is used by multiple people. To address the defined problem, a modified PM-segment that is in compliance with 11073 standards is proposed in this paper. In particular, the proposed PM-segment is designed to minimize the additional complexity of an agent instead of a manager and it is interoperable with the existing manager. The proposed PM-segment shows better performance than the existing PM-segment, in terms of memory requirements and expected queue time. Also, performance comparison among the three transfers is performed in regard to the delay time and communication power consumption points of view.

개인화된 힐링 데이터 접근을 위한 개방형 게이트웨이 프레임워크 설계 (Design of Open Gateway Framework for Personalized Healing Data Access)

  • 전영준;임석진;황희정
    • 한국인터넷방송통신학회논문지
    • /
    • 제15권1호
    • /
    • pp.229-235
    • /
    • 2015
  • ICT 힐링 플랫폼은 생체신호 및 생활습관 등의 정보를 기반으로 한 질환조기 경보를 목표로 하는 개념으로서 만성질환 예방을 목적으로 한다. ICT(Information & Communication Technology) 힐링플랫폼의 목표는 개인이 주도하는 건강관리를 위해 여러 건강 관련 서비스 기관들(병원, 피트니스센터, 건강검진센터, 개인건강장치 등)에 산재되어 있는 개인 건강 정보를 개방화하여 개인 단말장치로 모으고, 분석 플랫폼 및 Open API를 제공하여 다양한 부가 서비스들을 활성화하는데 있다. 본 논문에서 제안하는 개인화된 힐링 데이터 접근을 위한 개방형 게이트웨이 프레임워크인 HPAdapter (Healing Platform Adaptor)는 ICT 힐링플랫폼의 데이터 중계를 위해 EMR(Electronic health record), 한방의학, 라이프로그, 웰니스, 만성질활, 피트니스 등 다양한 개인 건강관련 데이터 공급자와 서비스 공급자 사이를 연결해 개인화된 힐링 데이터를 중계하는 소프트웨어 엔진을 뜻한다. 설계된 HPAdaptor는 데이터 및 서비스 공급자 연동을 통해 힐링 레코드 저장소, 모바일 플랫폼 및 분석 플랫폼 등 데이터를 필요로 하는 서비스 혹은 플랫폼의 중계참조 모델로 활용할 수 있다.

ISO/IEEE 11073 PHD 표준 구현을 통한 복잡도 분석 (Complexity Analysis for Implementation of the ISO/IEEE 11073 PHD Standards)

  • 김상곤;유돈식;김태곤
    • 한국통신학회논문지
    • /
    • 제37권4C호
    • /
    • pp.307-312
    • /
    • 2012
  • 본 논문에서는 ISO/IEEE 11073 개인건강기기(Personal Health Device: PHD) 표준을 임베디드시스템 상에 구현할 경우, 요구되는 시스템 재원을 파악하고자, ISO/IEEE 11073 개인건강기기 표준의 구현에 대한 복잡도 분석(Complexity Analysis)을 수행하였다. 다양한 개인용 건강기기 중 체중계, 혈압계, 그리고 혈당계의 구현된 프로그램을 기반으로 모의코드를 작성하였다. 그리고 난 후 프로그램 메모리 공간 및 데이터 메모리 공간 두 개의 다른 관점에서 복잡도 분석모델을 하였다. 개인건강기기는 그 특성상 재원 또는 성능의 제약이 있어 본 연구의 결과는 상기 표준의 구현에 요구되는 추가적인 시스템 재원을 추정하는데 유용하게 활용될 수 있다.

의료기기 재처리 세척 직원의 개인보호구 착용 이행의 영향요인 (Factors Influencing Compliance on the Use of Personal Protective Equipment during Cleaning of Medical Device Reprocessing Staffs)

  • 박현희;홍정화;정계선;이광옥
    • 근관절건강학회지
    • /
    • 제31권1호
    • /
    • pp.42-52
    • /
    • 2024
  • Purpose: This study aimed to identify the factors affecting compliance with personal protective equipment (PPE) use among medical device reprocessing staff. Methods: This descriptive cross-sectional study included 163 cleaning staff members from ten general hospitals in Seoul and Gyeonggi. Data were collected using self-report questionnaires administered between July and September 2023. Analysis included t-tests, ANOVA, Pearson's correlation coefficient, Bonferroni correction, and multiple regression, conducted using SAS ver.9.4. Results: Statistically significant differences in compliance with PPE were found based on department and exposure to contamination within six months (t=-2.82, p=.007). Attitudes toward PPE (r=.22, p=.006) and awareness of the safety climate (r=.22, p=.006) showed a statistically significant positive correlation with PPE compliance. Factors influencing use of personal protective equipment by cleaning staff during medical device reprocessing were department, compliance with PPE, and awareness of the safety climate. The explanatory power of these factors was 58.0%. Conclusion: Improving PPE compliance and creating a safe cleaning environment entails fostering a supportive safety climate. Additionally, regular training that takes into consideration the characteristics of the cleaning staff, alongside continuous monitoring, is required.

에너지 하베스팅 기반 개인 위치식별 장치 개발에 관한 연구 (Development of Personal Location Identification Device based on Energy Harvesting)

  • 하연철;손서우;박재문;이인성
    • 융합신호처리학회논문지
    • /
    • 제22권3호
    • /
    • pp.134-140
    • /
    • 2021
  • 본 연구는 에너지 하베스팅 기반 저전력 GPS와 IMU를 활용한 개인 위치를 식별할 수 있는 웨어러블 장치 개발에 관한 것이다. 개발된 개인 위치식별 장치는 압전소자를 이용한 에너지 하베스팅 기술을 적용하였고, GPS 및 IMU를 사용하여 정밀한 개인위치 데이터를 획득할 수 있도록 하였다. 실험 결과, GPS 및 IMU 데이터가 정상적으로 수신함을 확인하였다. 개인위치 식별장치는 재난 발생지역 등에서의 개인위치를 파악하여 안전사고에 대응하고, 시간, 장소 및 환경에 구애받지 않고 사용자가 손쉽게 사용할 수 있을 것이며, 레저나 헬스케어 등 다양한 방면에서 사용이 가능할 것으로 기대된다.