Browse > Article
http://dx.doi.org/10.9717/kmms.2014.17.5.640

Development of m-Health Application based on Medical Informatics Standards  

Park, Hyun Sang (Dept. of Medical Informatics, Kyungpook National Univ.)
Kim, Hwa Sun (Dept. of Medical Information Technology, Daegu Haany Univ.)
Jung, Hyun Jung (Dept. of Korean Medicine, Daegu Haany Univ.)
Cho, Hune (Dept. of Medical Informatics, Kyungpook National Univ.)
Publication Information
Abstract
Recently medical consumers pursue high leveled quality of life through active promotion, prevention, management activity of health as the importance of health during home life is emerged to meet the aging society and chronic diseases. In addition, people are directed to the m-Health for managing yourself their health by using smartphone and various personal health devices, if necessary transmits health data to the physician himself. In the previous studies, m-Health Application were developed and applied in the real clinical environment by adopting the medical information standards was rarely conducted. Therefore, in this study, the m-Health application platform was developed. Developed application was communicate with IEEE 11073 standard protocol using the Bluetooth Health Device Profile in personal health device via smart phone to process blood pressure information, and it converted to HL7 V2.6 ORU_R01 message for send to remote medical server. In addition, we tested the interoperability and safety of the developed application for 23 inpatient and 17 outpatient at D University Hospital. As a result, the blood pressure information has been transmitted without error.
Keywords
m-Health Application; Personal Health Device; Medical Informatics Standards; Blood Pressure;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 K.H. Park, M.I. Joo, D.E. Oh, T.W. Kim, H.C. Kim, "A Study of Vital Sign (ECG) Measuring based on ISO/IEEE 11073-20601," Proceedings of the Korea Multimedia Society Conference, pp. 209-210, 2012.   과학기술학회마을
2 K.L. Cho, S.Y. Kim, J.H. Kim, A.S. Oh, G.H. Kim, J.H. Jean, et al., "u-Healthcare Monitoring System Design using by Smartphone based on Bluetooth Health Device Profile," Journal of Information and Communication Convergence Engineering, Vol. 17, No. 6, pp. 1365-1369, 2013.   과학기술학회마을   DOI   ScienceOn
3 S.I. Kang and A.S. Oh, "A Design and Implementation of Mobile Healthcare System based on Smart Gateway," Journal of Information and Communication Convergence Engineering, Vol. 16, No. 9, pp. 1970-1976, 2012.   과학기술학회마을   DOI   ScienceOn
4 Y.J. Park, H.S. Cho, and J.W. Son, "Transmitting/ Receiving of Standard Health Data using Bluetooth HDP on the Android Platform," Journal of Information and Communication Convergence Engineering, Vol. 38C, No. 5, pp. 464-470, 2013.   과학기술학회마을   DOI   ScienceOn
5 M.W. Jung, J.G. Park, J.H. Kim, and J.G. Cho, "Interoperability between Medical Devices using Near Field Communication," International Conference on Information Science and Applications, pp. 1-4, 2013.
6 S.H. Kim, "Trend of Personal Health Device Standardization for u-health Service," Journal of Information and Communication Convergence Engineering, Vol. 29, No. 1, pp. 31-37, 2011.
7 S.I. Kang, "A Study on Oximetry System Based on ISO/IEEE 11073 using Smart-Phone," Journal of Information and Communication Convergence Engineering, Vol. 17, No. 8, pp. 1940-1946, 2013.
8 The Institute of Electrical and Electronics Engineers, ISO/ IEEE 11073-20601 Standard for Health Informatics - Personal Health Device Communication - Application Profile - Optimized Exchange Protocol, 2009.
9 H.N. Park, S.H. Kim, and D.S. Yoo, "Present Status and Analysis for IEEE 11073 Personal Health Device Specializations," Journal of Korea Information and Communications Society, Vol. 37, No. 6, pp. 469-475, 2012.   과학기술학회마을   DOI   ScienceOn
10 Bluetooth SIG, Health Device Profile Specification, pp. 1-44, 2012.
11 Y.J. Chang, G.H. Lee, J.H. Cha, J.H. Hur, and G.J. Park, "Proposed Development of Interoperability Evaluation Technology of uhealth Medical Device System," Telecommunications Technology Association Journal , No. 138, pp. 103-108, 2011.
12 Franca Delmastro, "Pervasive Communications in Healthcare", Computer Communications, Vol. 35, Issue 11, pp. 1284-1295, 2012.   DOI   ScienceOn
13 World Health Organization, Global Health Risks: Mortality and Burden of Disease Attributable to Selected Major Risk, 2009.
14 A. Benetos, A. Rudnichi, M. Safar, and L. Guize, "Pulse Pressure and Cardiovascular Mortality in Normotensive and Hypertensive Subjects," Hypertension, Vol. 30, No. 3, pp. 560-564, 1998.
15 OECD, Health at a Glance 2013, OECD, 2013.
16 Statistics Korea, 2013 Aged Person Statistics, Statistics Korea, 2013.
17 National Health Insurance Corporation, http://kosis.kr, 2014.
18 A. Alwan, D.R. MacLean, L.M. Riley, E.T. d'Espaignet, C.D. Mathers, G.A. Stevens, D. Bettcher, "Monitoring and Surveillance of Chronic Non-communicable Diseases: Progress and Capacity in Hight-burden Countries," The Lancet, Vol. 376, No. 9755, pp. 1861-1868, 2010.   DOI   ScienceOn
19 P.M. Kearney, M. Whelton, K. Reynolds, P. Muntner, P.K. Whelton, and J. He, "A Global Burden of Hypertension: Analysis of Worldwide Data," The Lancet, Vol. 365, No. 9455, pp. 217-223, 2005.   DOI   ScienceOn
20 S.H. Lee, Sociocultural Impact and Evolution of Mobile Health, Korea Information Society Development Institute, 2013.
21 H.J. Hwang, "New Approach of u-Health, Development Direction and the Current State of Wellness Standard," Telecommunications Technology Association Journal, No. 145, pp. 50-54, 2013.
22 Android Platform Versions, http://developer.android.com/about/dashboards/index.html, 2014.
23 R. Carroll, R. Cnossen, M. Schnell, and D. Simons, "Continua: An Interoperable Personal Healthcare Ecosystem," IEEE Pervasive Computing, Vol. 6, No. 4, pp. 90-94, 2007.
24 Y.J. Chang and G.H. Lee, "Trend of Test Certification Technologies in Continua," Telecommunications Technology Association Journal , No. 135, pp. 110-117, 2011.
25 International Data Corporation. 2013 Top Four Operating Systems Market Share, http://www.idc.com/getdoc.jsp?containerId=prUS24442013, 2014.
26 H.S. Kim, H. Cho, and I.K. Lee, "The Development of a Graphical User Interface Engine for the Convenient Use of the HL7 Version 2.x Interface Engine," Healthcare Informatics Research, Vol. 17, No. 4, pp. 214- 223, 2011.   DOI   ScienceOn
27 Logical Observation Identifiers Names and Codes, http://loinc.org/, 2014.
28 A&D Medical, http://www.telemedicine.jp/product_ua767pbt-c.html, 2014.
29 Korea Centers for Disease Control and Prevention, 2012 National Health Statistics, 2012.