• 제목/요약/키워드: Personal Cooling

검색결과 36건 처리시간 0.12초

고등학교 기숙사 주거시설에 대한 사용자 만족도 - 개인공간 단위실을 중심으로 - (Users' Satisfaction on the Dormitory of High School in Jeonju City)

  • 안진숙;최병숙
    • 한국주거학회논문집
    • /
    • 제18권6호
    • /
    • pp.93-101
    • /
    • 2007
  • This study was to find out users' satisfaction on the dormitory of high school in Jeonju City and to propose it's physical environmental improvement directions. This was performed by a questionnaire survey method, and the questionnaire was designed by researchers considering relative literatures. Data were collected from 200 students, who had been dwelling 4 high school dormitories in Jeonju City. By analyzing those data, findings were as follows: 1) Users of students were satisfied the whole of their dormitory; facilities, spaces, and living. 2) They were highly concerned about a library and a personal unit space in their dormitory. 3) They needed their personal unit space to be designed bedroom+bathroom type with 2 persons' sharing and be equipped one story bed and desk furniture. Also, they needed improvement on heating & cooling, small space and indoor air quality of unit space. 4) The users' satisfaction on unit space were 2.88, and their satisfaction of the technical factor was 2.71 that was the lowest score in them. And The functional factor was highly effected their satisfaction. 5) The space utility and the space size of functional factor, the soundproof, the heating/ventilation and the indoor quality of technical factor, and the privacy of behavior factor were highly correlative to their satisfaction of unit space.

사이버보안 전문가 양성을 위한 연구 (The Research for cyber security experts)

  • 김슬기;박대우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 춘계학술대회
    • /
    • pp.301-304
    • /
    • 2016
  • 사이버세계는 국가와 국민의 인프라를 구성하고 통제한다. 사이버 공격과 개인정보유출로 국민경제 피해 및 국가 안보가 위협당하고있다. 2014년 12월 사이버 해킹공격으로 한국수력원자력의 원자력 냉각시스템 설계도면이 유출된적이 있으며, 청와대 홈페이지 해킹, KBS 방송국 해킹 등 사이버사고의 발생하였다. 이에 따라 정보통신기반보호법, 정보통신망이용촉진 및 정보보호등에 관한법률, 개인정보보호법이 시행되고있으며, 앞서가는 첨단 기술로 무장한 해커의 공격을 막기는 어려우나 인터넷 정보화 사회에서 형식적인 요건으로 개인정보보호법을 지켜야 하는 개인정보책임자 양성방안을 제안하고자 한다.

  • PDF

저소음 축류형 소형홴의 개발 (Design of Low Noise Axial-Tube Fan)

  • 김기황;이승배;김병홍
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.17-22
    • /
    • 2001
  • Tube axial fans were designed to provide effective cooling for a personal computer by using $DasignFan^{TM}$ software. With basic input parameters of flow rate, pressure rise, rotating speed, and fan diameter, three dimensional geometry of blade is automatically generated and its performance and overall sound pressure level are predicted. In this steady, the newly developed fans of 60 mm and 80 mm diameters were proved to provide a very promising mode of low noise, compared with manufactured products.

  • PDF

PRT 차량하부 열부하 저감방안 도출 연구 (STUDY ON THE PREVENTION METHOD FOR HEAT ACCUMULATION FOR PERSONAL RAPID TRANSIT (PRT) VEHICLE UNDER BODY)

  • 권순박;송지한;강석원;정락교;김학범;이창현;서동관
    • 한국전산유체공학회지
    • /
    • 제18권1호
    • /
    • pp.58-62
    • /
    • 2013
  • Personal Rapid Transit (PRT) is the emerging personal transport vehicle operating on the loop automatically. The PRT system utilize the electrical power from super capacity or battery, it is important to manage the power or energy. In this regards, the management of high temperature occurred by the operation of system is significantly important to prevent from serious damage of component. In this study, we studied the adequate shape of underbody which can reduce the heat accumulation by pickup coil and condenser using natural air cooling. We suggested the additional air pathway, air inlet and flow separator to decrease the temperature of the heat source components. It was found that suggested system can decrease the temperature of PRT under body by 16% during the static mode and by 10% during the running mode at 30km/h. It is expected that the findings of this study will feed into final design of newly built Korean PRT vehicle.

에너지 효율화를 위한 그린 데이터센터 도입방안 (The Method of Green Data Center to Improve the Power Efficiency)

  • 최영진;문성준;김진한;김성한;신일섭;김기병
    • 디지털융복합연구
    • /
    • 제8권3호
    • /
    • pp.181-197
    • /
    • 2010
  • 최근에 에너지 절감에 대한 관성이 증가하고 있으며 IT분야에서도 IT서비스를 에너지 효율적으로 제공하는 그린 IT에 대한 관심이 높다. 특히, 대량의 전력 소모가 발생하는 데이터센터를 에너지 효율적으로 구축하기 위해 노력하고 있다. 그러나 그린 데이터 센터 구축은 개인에 의존하는 단계로 구축시 창조할 가이드라인이 부족하다. 특히 공조시설의 복잡성이 에너지 효율적인 센터 걸림돌이다. 이에 본 연구에서는 그린 데이터 센터 구축을 위한 태스크와 활동, 그리고 가이드라인을 제시하였다.

  • PDF

Environmental Modeling and Thermal Comfort in Buildings in Hot and Humid Tropical Climates

  • Muhammad Awaluddin Hamdy;Baharuddin Hamzah;Ria Wikantari;Rosady Mulyadi
    • Architectural research
    • /
    • 제25권4호
    • /
    • pp.73-84
    • /
    • 2023
  • Indoor thermal conditions greatly affect the health and comfort of humans who occupy the space in it. The purpose of this research is to analyze the influence of water and vegetation elements as a microclimate modifier in buildings to obtain thermal comfort through the study of thermal environment models. This research covers two objects, namely public buildings and housing in Makassar City, South Sulawesi Prov-ince - Indonesia. Quantitative methods through field surveys and measurements based on thermal and personal variables. Data analysis based on ASHRAE 55 2020 standard. The data was processed with a parametric statistical approach and then simulated with the Computational Fluid Dynamics (CFD) simulation method to find a thermal prediction model. The model was made by increasing the ventilation area by 2.0 m2, adding 10% vegetation with shade plant characteristics, moving water features in the form of fountains and increasing the pool area by 15% to obtain PMV + 0.23, PPD + 8%, TSV-1 - +0, Ta_25.7℃, and relative humidity 63.5 - 66%. The evaluation shows that the operating temperature can analyze the visitor's comfort temperature range of >80% and comply with the ASHRAE 55-2020 standard. It is concluded that water elements and indoor vegetation can be microclimate modifiers in buildings to create desired comfort conditions and adaptive con-trols in buildings such as the arrangement of water elements and vegetation and ventilation systems to provide passive cooling effects in buildings.

고등학교 기숙사 주거시설에 대한 사용자 만족도 (Users' Satisfaction on the Dormitory of High School in Jeonju City)

  • 안진숙;최병숙
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.202-207
    • /
    • 2006
  • This study was to find out users' satisfaction on the dormitory high school in Jeonju City and to propose it's physical environmental improvement directions. This was performed by a questionnaire survey method, and the questionnaire was designed by researchers considering relative literatures. Data were collected from 200 students, who had been dwelling 4 high school dormitories in Jeonju City. By analyzing those data, findings were as follows : 1) Users of students were satisfied the whole of their dormitory; facilities, spaces, and living. 2) They were highly concerned about a library and a personal unit space in their dormitory. 3) They needed their personal unit space to be designed bedroom+bathroom type with 2 persons' sharing and be equipped one story bed and desk furniture. Also, they needed improvement on heating & cooling, small space and indoor air quality of unit space. 4) The users' satisfaction on unit space were 3.23, and the space utility and the space size of functional factor and the heating/ventilation of technical factor were highly effected their satisfaction.

  • PDF

학원교실의 냉방시 실내공기질 실태와 영향요인 분석 (Analysis on Influencing factors and Actual State of Indoor Air Quality by Cooling in Private Institute Classrooms)

  • 최윤정;이혜진;이지연
    • 한국생활과학회지
    • /
    • 제17권5호
    • /
    • pp.1001-1013
    • /
    • 2008
  • The purpose of this study were to make clear the actual state of indoor air quality by cooling in private institute classrooms and to analyze influencing factors on indoor air quality. The measurements of physical elements and observations of architectural characteristics and living conditions were carried out in each 1 classroom of 5 private institutes. Measuring elements were indoor temperature, relative humidity, $PM_{10}$, HCHO, CO, and $CO_2$ concentration. As results, the averages of indoor temperature each classroom were $21.7\sim28.1^{\circ}C$. 3 classrooms were lower than the Maintenance standard($26\sim28^{\circ}C$) of School Health Law. The means of relative humidity were 48$\sim$63%, all classrooms were ranged within the standard(30$\sim$80%). The means of $PM_{10}$ concentration were 2.1 $\sim$ 17 $\mu g/m^3$, all classrooms were kept within the standard(100 $\mu g/m^3$). The means of HCHO concentration were 0.02$\sim$0.16 ppm, 2 classrooms were exceed the standard(0.1 ppm). The means of CO concentration were 1.4$\sim$3.6 ppm, all classrooms were kept within the standard(10ppm). The means of $CO_2$ concentration were 1,593$\sim$3,819 ppm, all classrooms were exceed the standard(1,000ppm). The results of analysis on influencing factors of the physical elements are as follow; the air conditioner set of temperature, personal necessities like hair spray, teacher's smoking in corridor, windows and doors opening time, the number of students, and volume of classroom.

분리형 히트파이프를 이용한 전자장비내 발열체의 온도제어에 관한 연구 (The Study of Using Separate Heatpipes for Thermal Control in Electronic Equipments)

  • 배석태
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권2호
    • /
    • pp.305-311
    • /
    • 2003
  • This Paper Presents an information about the heat transfer characteristics of a separate type thermosyphon in electronic equipments. The heat removal problem of electronic equipments is regarded as an important factor and a separate type heatpipes can be utilized as a cooling device of electronic equipments (such as CPU of a Personal computer or notebook). In this study. heat source ($50\times50\times2 mm $aluminum Pseudo CPU) was used for the experiment. The device can transfer heat from the evaporator to the condenser through natural circulation (without any external driving forces) and the results indicate that the device is capable of dissipating over 60W of thermal energy and keeping the heating plate surface temperature under $50^{\circ}C$.

Experimental Research for Performance and Noise of Small Axial Fan

  • Ito, Takahiro;Minorikawa, Gaku;Fan, Qinyin
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권2호
    • /
    • pp.136-146
    • /
    • 2009
  • Small axial fans have become widely used as cooling devices in recent years. Because of their increasing importance, studies have been conducted on ways to improve the performance and reduce the noise of such fans. In this report, a small axial fan with a diameter of 85 mm (a type popularity used in personal computer or workstation) was selected for further examination. The influence on aerodynamic performance and noise of such frame design parameters as blade tip clearance results in a decrease of discrete frequency noise and an increase of broad-spectrum noise. As for the most suitable design refinement in terms of fan efficiency, we found that the treatment of outlet corner roundness and altering spoke skew to the direction counter to that of fan rotation was effective.