• 제목/요약/키워드: Permanent magnet synchronous machines

검색결과 100건 처리시간 0.025초

Design and Analysis of Axial Flux Permanent Magnet Synchronous Machine

  • Jo, Won-Young;Lee, In-Jae;Cho, Yun-Hyun;Koo, Dae-Hyun;Chun, Yon-Do
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.61-67
    • /
    • 2007
  • In this article, a special kind of axial flux permanent magnet machine has proved to be suitable for high torque and low speed applications. An innovative design of the machine has been proposed in order to make the machine suitable for traction applications by means of field-weakening. The aim of this paper is to analyze, in general terms, the basic equations that describe the operating conditions of such machines. Optimal sizes for design can be obtained by calculating the power density and the air-gap flux density, etc.

Design of Surface Permanent Magnet-type Vernier Motor

  • Kakihata, Hironori;Kataoka, Yasuhiro;Takayama, Masakazu;Matsushima, Yoshitarou;Anazawa, Yoshihisa
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권2호
    • /
    • pp.127-133
    • /
    • 2013
  • In this paper, the authors designed a surface permanent magnet (SPM)-type vernier motor whose maximum output is more than 5.2 kW, whose power factor at 4 kW is more than 90%, and whose efficiency at 4 kW is 85% under the conditions that the operating voltage, frequency, and synchronous speed are 400 V, 50 Hz, and 100 min-1, respectively.

영구자석 기기의 철손 예측을 위한 자계 거동 해석 (Magnetic Field Distribution Analysis for Core Loss Estimation of Permanent Magnet Machine)

  • 장석명;고경진;최장영;박지훈;이성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.93-95
    • /
    • 2008
  • Nowadays more attention is paid to the developing high efficiency electrical machines for energy saving and protection of natural resources. In general, the electromagnetic losses appearing in electrical machines are widely classified into copper loss, core loss and rotor loss. Particularly, in permanent magnet (PM) machines, core loss forms a larger portion of the total losses than in another machine. So, satisfactory prediction of core loss at the design or analysis stage of PM machines is essential to active high efficiency and high performance. This paper deals with analysis of magnetic field distribution due to geometry of stator core for magnetic core loss calculation of multi-pole PM synchronous machine.

  • PDF

Stand-Alone Pico-Hydro Generation System using a High-Efficiency IPM Synchronous Generator

  • Kurihara, Kazumi;Kubota, Tomotsugu
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.121-125
    • /
    • 2014
  • This paper presents a successful stand-alone pico-hydro generation system using a high-efficiency interior permanent-magnet (IPM) synchronous generator. A 1-kW 4-pole V-type IPM generator with low voltage regulation is used for laboratory test in stand-alone hydro energy conversion system. It has been found from experimental results that the constant output voltage is supplied stably by the proposed system under wide speed range.

A New Predictive Current Controller for a PMSM with consideration of calculation delay

  • Moon H.T.;Youn M.J.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.336-340
    • /
    • 2001
  • In a digital system, there are inevitable delays in calculations and applying the inverter output voltages to the motor terminals. Because of the delays, the conventional predictive current controller implemented in the digital system has large overshoot and large harmonics. A new predictive current controller, considering the delays, for a permanent magnet synchronous motor (PMSM) is presented. The effectiveness and feasibilities are shown by experimental results.

  • PDF

Improved Torque Calculation of High Speed Permanent Magnet Motor with Compressor Loads Using Measured Power Factor Angle and Analytical Circuit Parameters

  • Choi, Jang-Young;Jang, Seok-Myeong;Lee, Sung-Ho
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권2호
    • /
    • pp.159-164
    • /
    • 2013
  • Difficulty of torque measurements in high-speed permanent magnet (HSPM) motors has necessitated the development of improved torque calculations. Hence, this paper presents an analytical torque calculation of a high speed permanent magnet (HSPM) motor based on the power factor angle. On the basis of analytical magnetic field solutions, the equations for circuit parameters such as back-emf and synchronous inductance are derived analytically. All analytical results are validated extensively by non-linear finite element (FE) calculations and measurements. The internal angle (${\delta}$) between the back-emf and the phase current is calculated according to the rotor speed by using analytical circuit parameters and the measured power factor because this angle is not measured but estimated in case of sensorless drive of the HSPM motor, significantly affecting torque calculation. Finally, the validity of the torque analysis method proposed in this paper is confirmed, by showing that the torque calculated on the basis of the internal angle is in better agreement with the measurements.

영구자석 사용 효율 향상을 위한 IPM 전동기의 최적 토폴로지 (Topology Optimal Interior Permanent Magnet Machine to Improve the Utilization Ratio of Permanent Magnet)

  • 도욱;장전해;주립훈;고창섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.862-863
    • /
    • 2015
  • This paper presents an improved estimation procedure for the contribution to no-load flux linkage created by the permanent magnet (PM) in interior permanent magnet synchronous machines. In the proposed method, the saturation effect in stator and rotor cores are taken into account by utilizing the frozen permeability method (FPM). This improved procedure can evaluate the contribution for each local element in the PM to the no-load flux linkage. According to the analysis results, an effective PM topology optimal design can be carried out to achieve high utilization ratio of PM in the machine. In order to determine the threshold of the low contribution of PM for removing, one multi-objective optimization model is proposed. Based on the optimal threshold, the final optimal topology design of PM can be achieved.

  • PDF

외전형 영구자석형 전동/발전기의 성능해석 (Performance Analysis of External Rotor Type Permanent Magnet Motor/Generator)

  • 장석명;고종운;윤인기;이성호;정상섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.641-643
    • /
    • 2002
  • Synchronous generator needs slip-ring and brush for supplying current to rotor with external source. but slip-ring and brush have some problems to supply DC power to field winding with friction and high power loss due to brush voltage drop at high field current. Thus synchronous generator have been designed to brushless machine. Brushless synchronous machines of using permanent halbach array can composed without back core and coreloss. In this paper, analyse on the characteristics of external rotor type permenant magnet brushless with halbach array.

  • PDF

Current Sliding Mode Control with a Load Sliding Mode Observer for Permanent Magnet Synchronous Machines

  • Jin, Ningzhi;Wang, Xudong;Wu, Xiaogang
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.105-114
    • /
    • 2014
  • The sliding mode control (SMC) strategy is applied to a permanent magnet synchronous machine vector control system in this study to improve system robustness amid parameter changes and disturbances. In view of the intrinsic chattering of SMC, a current sliding mode control method with a load sliding mode observer is proposed. In this method, a current sliding mode control law based on variable exponent reaching law is deduced to overcome the disadvantage of the regular exponent reaching law being incapable of approaching the origin. A load torque-sliding mode observer with an adaptive switching gain is introduced to observe load disturbance and increase the minimum switching gain with the increase in the range of load disturbance, which intensifies system chattering. The load disturbance observed value is then applied to the output side of the current sliding mode controller as feed-forward compensation. Simulation and experimental results show that the designed method enhances system robustness amid load disturbance and effectively alleviates system chattering.

표면부착형 / 매입형 영구자석 동기 전동기의 비교 분석 (Comparative Analysis of Surface-mounted and Interior Permanent Magnet Synchronous Motor)

  • 박형일;김관호;신경훈;장석명;최장영
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.987-994
    • /
    • 2016
  • In this paper, we present a comparative analysis of surface-mounted permanent magnet synchronous motors (SPMSM) and interior permanent magnet synchronous motors (IPMSM). First, we use 2D finite element analysis (FEA) to analyze models satisfying the same rated conditions according to the torque-speed curve characteristics, which are determined from the operating conditions. Next, we manufacture an SPMSM and IPMSM having good performances from an electromagnetic perspective based on analysis results, namely the cogging torque, torque ripple, and efficiency. We analyze both of the manufactured machines when they are connected back-to-back and when they are used as a motor and a generator, respectively. The motor is driven by a commercial inverter and the generator is connected to a three-phase resistance load bank. Finally, based on experimental results, which include the total harmonic distortion (THD) of the back electro-motive force (EMF), cogging torque, efficiency, and mass, we determine the motor that is most suitable under requirements.