• Title/Summary/Keyword: Peripheral Device

Search Result 158, Processing Time 0.029 seconds

A Design of LAS data processing board using PowerPC and VxWorks (PowerPC 및 VxWorks를 이용한 예인배열센서 데이터처리보드 개발)

  • Lim, Byeong-Seon;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.371-374
    • /
    • 2009
  • This Paper deal with a design, making a prtotype and test methods of Real-time towed Line Array Sensor Data processing board for fast data communication and long range transmission with SFM(Serial FPDP Module) through Optic-fiber channel. The LAS A,B,C group Data from towed line array sensor which is installed in FFX(Fast Frigate eXperimental) of Korean Navy is packed a previously agreed protocol and transmitted to the Signal processing unit. Consider the limited space of VME 6U size, LAS Data processing board is designed with MPC8265 PowerPC Controller of Freescale for main system control and Altera's CycloneIII FPGA for sensor data packing, self-test simulation data generation, S/W FIFO et cetera. LAS Data processing board have VxWorks, the RTOS(Real Time Operating System) that present many device drivers, peripheral control libraries on board for real-time data processing.

  • PDF

Electromagnetic Susceptibility Design of Tracking Radar Systems (추적 레이다 시스템의 전자기파 내성 설계)

  • Hong-Rak Kim;Youn-Jin Kim;Seong-Ho Park;Man Hee LEE;Da-Been LEE
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.2
    • /
    • pp.51-59
    • /
    • 2023
  • The tracking radar system is installed and operated on the ground, ships, and aircraft, and requires a design to withstand electromagnetic interference with nearby electronic devices. In this case, radiation and immunity standards for cable connection must be satisfied to prevent malfunction of other equipment due to electromagnetic wave interference caused by cables connected to the tracking radar. The radiation standard must also be satisfied so that the electromagnetic wave noise generated and radiated from the tracking radar does not affect the peripheral device, so that the immunity standard for the electromagnetic wave emitted from the peripheral device must be satisfied. In this paper, we propose a design to satisfy MIL-STD-461G including CE, CS, RE, and RS, and explain design satisfaction through tests.

The Fabrication of Four-Terminal Poly-Si TFTs with Buried Channel (Buried Channel 4단자 Poly-Si TFTs 제작)

  • Jeong, Sang-Hun;Park, Cheol-Min;Yu, Jun-Seok;Choe, Hyeong-Bae;Han, Min-Gu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.12
    • /
    • pp.761-767
    • /
    • 1999
  • Poly-Si TFTs(polycrystalline silicon thin film transistors) fabricated on a low cost glass substrate have attracted a considerable amount of attention for pixel elements and peripheral driving circuits in AMLCS(active matrix liquid crystal display). In order to apply poly-Si TFTs for high resolution AMLCD, a high operating frequency and reliable circuit performances are desired. A new poly-Si TFT with CLBT(counter doped lateral body terminal) is proposed and fabricated to suppress kink effects and to improve the device stability. And this proposed device with BC(buried channel) is fabricated to increase ON-current and operating frequency. Although the troublesome LDD structure is not used in the proposed device, a low OFF-current is successfully obtained by removing the minority carrier through the CLBT. We have measured the dynamic properties of the poly-Si TFT device and its circuit. The reliability of the TFTs and their circuits after AC stress are also discussed in our paper. Our experimental results show that the BC enables the device to have high mobility and switching frequency (33MHz at $V_{DD}$ = 15 V). The minority carrier elimination of the CLBT suppresses kink effects and makes for superb dynamic reliability of the CMOS circuit. We have analyzed the mechanism in order to see why the ring oscillators do not operate by analyzing AC stressed device characteristics.

  • PDF

Active Vibration Control of a Plate Using TMS320C6713DSK

  • Choi, Hyeung-Sik;You, Sam-Sang;Her, Jae-Gwan;Seo, Hae-Yong;Tran, Ngoc-Huy
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.309-316
    • /
    • 2011
  • This paper deals with the experimental study of the vibration suppression of the smart structures. First, a new high-speed active control system is presented using the DSP320C6713 microprocessor. A peripheral system developed is composed of a data acquisition system, A/D and D/A converters, piezoelectric (PZT) actuator/sensors, and drivers using PA 95 for fast data processing. Next, the processing time of the peripheral device is tested and the corresponding test results are provided. Since fast data processing is very important in the active vibration control of the structures, achieving the fast loop times of the control system is focused. The control algorithm using PPF in addition to FIR filter is implemented. Finally, numerous experiments were carried out on the aluminum plate to validate the superior performance of the vibration control system at different control loop times.

A Study on AC Servo System for FA using High-performance DSP (고성능 DSP기반의 FA 용 AC서보 시스템에 관한 연구)

  • 최치영;홍선기;김수길
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.67-72
    • /
    • 2004
  • AC servo system has been implemented to FA system and also depends on its quality. Recently with the development of power switching device and DSP which has peripheral devices to control AC servo system, the servo technology has met a new development opportunity. A DSP based AC servo system with a 3-phase PMSM is proposed. The newly produced DSP TMX320F2812-version C which has the performance of fast speed, 150MIPS, and rich peripheral interface is used. Also space vector pulse width modulation (SVPWM) and the digital PI control are implemented to the servo system

Development of Peripheral Devices on the Endoscopic Surgery System (내시경 수술시스템의 주변장치 개발)

  • Lee, Young-Mook;Song, Chul-Gyu;Lee, Sang-Min;Kim, Won-Ky
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.164-166
    • /
    • 1995
  • The objectives of study are to develop a peripheral device on the endoscopic surgery system. These systems are consist of the following units. They are a color monitor of high resolution, light source, computer system and endoscopic camera with a C-mount head, irrigator, color video printer, Super VHS recorder and a system rack. The color monitor is a NTSC monitor for monitoring the image projected of the surgical section. The lightsource is necessary to irradiate the interior of a body via an optic fiber, The light projector will adapt the brightness in accordance with changing distance from the object. A miniature camera using a color CCD chip and computer system is used to capture and control an image of the surgical section[1]. The video printer is a 300 DPI resolution using thermal sublimation methods, which is developed by Samsung Electronics Co., Ltd. The specification of the endoscopic data management system is consist of storage of a captured image and pathological database of patients [2-4].

  • PDF

Analysis of cornea thickness and intra ocular pressure of 20 to 24 years old population in Korea (한국인 20세부터 24세까지 각막 두께와 안압의 분석)

  • Douk Hoon Kim;Kishor Sapkota
    • Journal of Korean Clinical Health Science
    • /
    • v.11 no.1
    • /
    • pp.1632-1638
    • /
    • 2023
  • Purpose: The aim of this study was to determine the distribution of the cornea thickness and intra ocular pressure Korean adult of 20 to 24 year old using the Pentacam and tonometer. Methods: The subjects of this study were 43 Korean adults with healthy eyes. Corneal thickness was measured with Pentacam device. The intra ocular pressure was measured with tonometer. Data was analyzed by means of the Pearson's correlation cofficient. P-values<0.001 were considered statistically significant. Results: Mean age of subjects was 20.41±0.86 years. The mean +/- intra ocular pressure of the right eye and left eye were 16.236±2.523mmHg and 16.971±1.992mmHg, respectively. The mean central corneal thickness of the right eye and left eye was 545.324±38.682㎛ and 547.442±33.778㎛, respectively. No significant difference in central corneal thickness was found between the right and left eyes. But, there was a statistically significant difference between central cornea thickness and peripheral cornea thickness around 4 mm of central cornea(p<0.001, Pearson's correlation). However there was no statistically significant difference between central cornea thickness and intra ocular pressure. Conclusion: The results of this study could be used as a clinical reference data for diagnosis and treatment of cornea in Korean adult.

Full-Custom Design of a Serial Peripheral Interface Circuit for CMOS RFIC Testing (CMOS RF 집적회로 검증을 위한 직렬 주변 인터페이스 회로의 풀커스텀 설계)

  • Uhm, Jun-Whon;Lee, Un-Bong;Shin, Jae-Wook;Shin, Hyun-Chol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.9
    • /
    • pp.68-73
    • /
    • 2009
  • This paper presents an easily modifiable structure of a serial peripheral interface (SPI) that is suitable for efficient testing of CMOS RF integrated circuits. The proposed SPI Is designed so that the address size and the accompanying software can be easily adjusted and modified according to the requirements and complexity of RF IC's under development. The hardware architecture and software algorithm to achieve the flexibility are described. The proposed SPI is fabricated in $0.13{\mu}m$ CMOS and successfully verified experimentally with a 2.7GHz fractional-N delta-sigma frequency synthesizer as a device under test.

Utility of Toe-brachial Index for Diagnosis of Peripheral Artery Disease

  • Park, Seong-Chul;Choi, Chang-Yong;Ha, Young-In;Yang, Hyung-Eun
    • Archives of Plastic Surgery
    • /
    • v.39 no.3
    • /
    • pp.227-231
    • /
    • 2012
  • Background : The ankle brachial pressure index (ABI) is a simple, useful method for diagnosing peripheral artery disease (PAD). Although the ABI is an objective diagnostic method, it has limited reliability in certain scenarios. The aim of the present study was to determine the accuracy and reliability of the toe brachial index (TBI) as a diagnostic tool for detecting stenosis in PAD, associated with normal or low ABI values. Methods : ABI and TBI values were measured in 15 patients with diabetic gangrene who were suspected of having lower extremity arterial insufficiency. The ABI and TBI values were measured using a device that allowed the simultaneous measurement of systolic blood pressure in the upper and lower extremities. In addition, the ABI and TBI values were compared pre- and post-angiography. Results : Patients with an ABI of 0.9-1.3 showed almost no difference between the 2 measurements. The patients with TBI >0.6 had no arterial insufficiency. The patients with TBI <0.6 required vascular intervention with ballooning. After the angiography, the gangrenous wounds decreased in size more rapidly than they did prior to the intervention. Conclusions : Our findings suggest that TBI is the method of choice for evaluating lower limb perfusion disorders. This result requires further studies of TBI in a larger number of patients. Future long-term studies should therefore evaluate the utility of TBI as a means of screening for PAD and the present findings should be regarded as preliminary outcomes.

Development of Neuromuscular Stimulus System using Wearable Ultra-miniature Lighting Modules and its Verification of Clinical Effectiveness (의복형 초소형 발광모듈을 이용한 신경근육 자극 시스템 개발 및 임상적 효과 검증)

  • Park, Se-Hyeong;Lee, Jong-Shill;Kim, In-Young;Kim, Sun-I.
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.23-33
    • /
    • 2009
  • It can be used easily to reduce rehabilitation and treatment time if diagnostic and therapeutic devices are attached to cloth or body. Therefore we developed neuromuscular wearable ultra-miniature lighting modules which can improve the neuromuscular function and verified its clinical effectiveness. The system is based on the ultra-miniature lighting treatment module and there are two types of systems. One of them is designed as an attached type and the other type is combined with clothing. The wearable ultra-miniature lighting module is composed of controller (battery, MCU, bidirectional transmitter and receiver), cable, treatment medium generating device and other peripheral devices. To verify the clinical effectiveness of this device, we observed the difference of the strength of a muscle before and after 650nm and 25mW laser irradiation on the reflex point for 1 to 4 seconds. Among 48 patients having the degenerative osteoarthritis, the muscle strength before and after irradiation of laser was $21.8{\pm}7.99$ and $27.3{\pm}8.43$. According to the result, the muscle strength after treatment was significantly increased (p<0.01). To whom having difficulty in visiting to OPD(Out-Patient Department), doctors medically examine the patients and find the therapeutic point, attachment of this wearable ultra-miniature lighting module can function as self treatment (treating instrument) and treatment assist at home. If doctor can remotely control the patient and take part in treatment, the therapeutic device could contribute to prevention and care device.