• Title/Summary/Keyword: Peripheral Device

Search Result 158, Processing Time 0.029 seconds

Development of Day and Night Scope with BS Prism (BS 프리즘을 이용한 주야 조준경 개발)

  • Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.339-344
    • /
    • 2014
  • Purpose: This study relates to the development of the day and night scope using the reflecting surface of a BS (beam splitting) prism. Methods: We have placed the LCD panel and the dot reticle generator to the top and bottom of the reflecting surface of the BS prism, and have placed a reflector, which is designed to doublet type, in the front of the BS prism. Doing so, we have developed a new type of day and night scope, which is able to image the virtual image of dot reticle from the dot reticle generator to the direction of the observer, to make the observer survey the peripheral information of the outside target by 1x magnification, and to make the observer survey the image of the LCD panel directly. Results: We could develope a new type of day and night scope, which has the function of night scope as thermal image display device at night time and the function of day scope as dot sight at day time, by letting the reflective surface of the BS prism have the role of dot sight which reflects the dot reticle and have the role of reflective optical system by which the observer surveys the night thermal image displayed in LCD panel. Conclusions: In this study, we have developed the new type of day and night scope which is able to play the role of the day or night scope selectively, combining the existing dot sight and the existing night scope by using the BS prism. By doing so, we could design and fabricate the new type of day and night scope with the BS prism which can further increase the rapidity of firing and provide more convenience in the mounting of a firearm than the detachable combination of an existing dot sight and an existing night scope.

IPTV and User Scenario-Based Interface in Home Network Service (홈 네트워크 환경에서 사용자 중심 시나리오를 활용한 IPTV 인터페이스 분석)

  • Lee, Jee-Hee;Kim, So-Hyun;Kim, Hyun-Suk
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.92-100
    • /
    • 2010
  • Due to the development of digital appliance, role of TV causes both-way by introducing IPTV, and SNS service causes big change of watching environment and residence environment. There are good conditions on the role of integrated control because it is arranged in the living room which secures movement most effectively and because family members can easily use, and the degree of use is high. Therefore, we infer user's needs by analyzing user scenario and current role of TV in home network environment. Primarily, we collect surveys of development scenario and technology which companies suggest TV applied by home network service, and secondly, we comparatively study scenario which the companies mentioned above suggest through observing user scenario, and study the role of IPTV in the future through actual scenario-based experiment by ethnography. After analyzing user scenario through case study and experiment, there are integrated device studies mainly in company study because it can be made up inside home, security and entertainment. On the other hand, there are patterns of user behavior by scenario experiment mainly in auto-tainment, security, and it showed that it is insufficient for interaction between TV and home media peripheral. Through this paper, we analyze context of home user, and based on this, we could suggest effective use of service development. Also after analyzing user form, we could know it also should be considered of ratio between activity inside home and activity outside home.

Development of Current Limiting COS Fuse Link with Improved Overcurrent and Protection Coordination performance (과전류 차단과 보호협조 성능이 향상된 한류형 COS 퓨즈링크 개발)

  • Kim, Youn-Hyun;Kim, Young-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.129-136
    • /
    • 2020
  • A Cut Out Switch (COS) is used for line protection and pole transformer protection in power systems. The COS used to protect the pole transformer is installed on the power side of the pole transformer to protect the electric equipment from fault currents. The COS is composed largely of a body and a fuse holder, and when the fault current is energized, the element of the fuse link in the fuse holder is melted to block the fault current. The arc generated when the COS fuse link is blown causes fire and noise, causing discomfort to residents in the surrounding area, and the arc flame can cause secondary damage to the peripheral device. In this study, a current-limiting COS fuse with improved overcurrent blocking performance rather than explosion type was developed to solve the arc and noise problems during COS operation. The overcurrent breaking performance of the current-limiting COS improves the reliability by developing a striker and COS fuse bracket. In addition, this study aimed to verify the performance of the developed current-limiting COS fuse through a test at an authorized institution.

Cardiovascular Responses over the Time Course during Muscle Group III Stimulation in Prehypertensive Individuals (고혈압 전단계자들에 대한 골격근 Group III 자극 시 시간에 따른 심혈관 반응)

  • Park, Won-Il;Park, Si-Young;Choi, Hyun-Min;Lee, Joon-Hee;Jeon, Jong-Mok;Kim, Jong-Kyung;Shim, Jae-Kun;Nho, Ho-Sung
    • Journal of Life Science
    • /
    • v.19 no.11
    • /
    • pp.1568-1574
    • /
    • 2009
  • The purpose of this study was to investigate whether group III muscle afferents play an important role eliciting abnormal blood pressure response mediated during passive muscle stretch in prehypertensive individuals. Eleven middle-aged prehypertensive men (average BP 133/80 mmHg) and nine middle-aged normotensive men (average BP 119/74 mmHg) participated in this study. After 1 min rest baseline data collection, the subject's foot was flexed (dorsiflexion) by an automated cybex for one minute. Systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial blood pressure (MAP), heart rate, stroke volume, cardiac output, and total peripheral resistance were continuously measured on a beat-by-beat basis from a finger via a Finapres device for 1 minute. To evaluate the role of mechanoreflex, a component of exercise pressor reflex, SBP, DBP, and MAP responses over the course of time were examined. The results showed that the pressor response mediated by the muscle mechanoreflex was faster in prehypertensive individuals compared to the normotensive individuals. The substantial pressor response was observed within mean 20 sec of the onset of passive stretch in prehypertension, while mean 45 sec in normotension (p<0.05). It is concluded that excessive pressor response produced during exercise in prehypertension may be due to the dysfunction of the mechano-receptors.

Microsurgical DREZotomy for Deafferentation Pain (구심로 차단 동통에서의 미세 후근 진입부 절제술)

  • Kim, Seong-Rim;Lee, Kyung Jin;Cho, Jeong Gi;Rha, Hyung Kyun;Park, Hae Kwan;Kang, Joon Ki;Choi, Chang Rak
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.85-90
    • /
    • 2001
  • Objective : DREZotomy is effective for the treatment of deafferentation pain as a consequence of root avulsion, postparaplegic pain, posttraumatic syrinx, postherpetic neuralgia, spinal cord injury, and peripheral nerve injury. We performed microsurgical DREZotomy to the patients with deafferentation pain and relieved pain without any serious complication. The purpose of this study is to evaluate the usefulness of the microsurgical DREZotomy for deafferentation pain. Methods : We evaluated 4 patients with deafferntation pain who were intractable to medical therapy. Two of them were brachial plexus injury with root avulsion owing to trauma, one was axillary metastasis of the squamous cell carcinoma of the left forearm, and the last was anesthesia dolorosa after surgical treatment(MVD and rhizotomy) of trigeminal neuralgia. Preoperative evaluation was based on the neurologic examination, radiologic imaging, and electrophysiological study. In the case of anesthesia dolorosa, we produced two parallel lesions in cephalocaudal direction, 2mm in distance, from the C2 dorsal rootlet to the 5mm superior to the obex including nucleus caudalis, after suboccipital craniectomy and C1-2 laminectomy, with use of microelectrode. In the others, we confirmed lesion site with identification of the nerve root after hemilaminectomy. We performed arachnoid dissection along the posterolateral sulcus and made lesion with microsurgical knife and microelectrocoagulation, 2mm in depth, 2mm in distance, to the direction of 30-45 degrees in the medial portion of the Lissauer's tract and the most dorsal layers of the posterior horn at the one root level above and below the lesion. Results : Compared with preoperative state, microsurgical DREZotomy significantly diminished dosage of the drugs and relieved pain meaningfully. One patient showed tansient ipsilateral ataxia, but recovered soon. There was not any serious complication. Conclusion : It may be concluded that microsurgical DREZotomy is very useful and safe therapeutic modality for deafferentation pain, especially segmentally distributed intermittent or evoke pain. Complete preoperative evaluation and proper selection of the patients and lesion making device are needed to improve the result.

  • PDF

Design and Implementation of License Web Courseware based on the Cognitive Apprenticeship Theory (인지적 도제이론에 기반한 자격증 웹 코스웨어 설계 및 구현)

  • Kim, Nam-Ju;Kang, Yun-Hee;Kim, Deok-Hwan;Lee, Ju-Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.3
    • /
    • pp.21-30
    • /
    • 2006
  • This study applies the cognitive apprenticeship theory a representative learning theory of constructivism. to design and create a web courseware for data device operator license. to enable research that begins with peripheral participation in Problem solving and ends with full participation and initiative, to act as a medium for assisting students in learning, to enable adaptation to actual situations through simulation studies, to allow aggressive interaction, and to help reinforce the level of data processing with regard to learning. The student was made to evaluate learning materials at real time for feedback on insufficient areas, to enable effective learning. The study was done by offering a web courseware without applying the cognitive apprenticeship theory and a web courseware with the cognitive apprenticeship theory, which was followed by an evaluation on study achievement level and learning behavior and then a survey was done after the evaluations. The results of this study were first, the learning group with web courseware applying cognitive apprenticeship theory showed more effect in improving learning achievement than the group with web courseware without the cognitive apprenticeship theory. Secondly, learning with web courseware applying cognitive apprenticeship theory was more effective for improving learning behavior.

  • PDF

Hardware Approach to Fuzzy Inference―ASIC and RISC―

  • Watanabe, Hiroyuki
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.975-976
    • /
    • 1993
  • This talk presents the overview of the author's research and development activities on fuzzy inference hardware. We involved it with two distinct approaches. The first approach is to use application specific integrated circuits (ASIC) technology. The fuzzy inference method is directly implemented in silicon. The second approach, which is in its preliminary stage, is to use more conventional microprocessor architecture. Here, we use a quantitative technique used by designer of reduced instruction set computer (RISC) to modify an architecture of a microprocessor. In the ASIC approach, we implemented the most widely used fuzzy inference mechanism directly on silicon. The mechanism is beaded on a max-min compositional rule of inference, and Mandami's method of fuzzy implication. The two VLSI fuzzy inference chips are designed, fabricated, and fully tested. Both used a full-custom CMOS technology. The second and more claborate chip was designed at the University of North Carolina(U C) in cooperation with MCNC. Both VLSI chips had muliple datapaths for rule digital fuzzy inference chips had multiple datapaths for rule evaluation, and they executed multiple fuzzy if-then rules in parallel. The AT & T chip is the first digital fuzzy inference chip in the world. It ran with a 20 MHz clock cycle and achieved an approximately 80.000 Fuzzy Logical inferences Per Second (FLIPS). It stored and executed 16 fuzzy if-then rules. Since it was designed as a proof of concept prototype chip, it had minimal amount of peripheral logic for system integration. UNC/MCNC chip consists of 688,131 transistors of which 476,160 are used for RAM memory. It ran with a 10 MHz clock cycle. The chip has a 3-staged pipeline and initiates a computation of new inference every 64 cycle. This chip achieved an approximately 160,000 FLIPS. The new architecture have the following important improvements from the AT & T chip: Programmable rule set memory (RAM). On-chip fuzzification operation by a table lookup method. On-chip defuzzification operation by a centroid method. Reconfigurable architecture for processing two rule formats. RAM/datapath redundancy for higher yield It can store and execute 51 if-then rule of the following format: IF A and B and C and D Then Do E, and Then Do F. With this format, the chip takes four inputs and produces two outputs. By software reconfiguration, it can store and execute 102 if-then rules of the following simpler format using the same datapath: IF A and B Then Do E. With this format the chip takes two inputs and produces one outputs. We have built two VME-bus board systems based on this chip for Oak Ridge National Laboratory (ORNL). The board is now installed in a robot at ORNL. Researchers uses this board for experiment in autonomous robot navigation. The Fuzzy Logic system board places the Fuzzy chip into a VMEbus environment. High level C language functions hide the operational details of the board from the applications programme . The programmer treats rule memories and fuzzification function memories as local structures passed as parameters to the C functions. ASIC fuzzy inference hardware is extremely fast, but they are limited in generality. Many aspects of the design are limited or fixed. We have proposed to designing a are limited or fixed. We have proposed to designing a fuzzy information processor as an application specific processor using a quantitative approach. The quantitative approach was developed by RISC designers. In effect, we are interested in evaluating the effectiveness of a specialized RISC processor for fuzzy information processing. As the first step, we measured the possible speed-up of a fuzzy inference program based on if-then rules by an introduction of specialized instructions, i.e., min and max instructions. The minimum and maximum operations are heavily used in fuzzy logic applications as fuzzy intersection and union. We performed measurements using a MIPS R3000 as a base micropro essor. The initial result is encouraging. We can achieve as high as a 2.5 increase in inference speed if the R3000 had min and max instructions. Also, they are useful for speeding up other fuzzy operations such as bounded product and bounded sum. The embedded processor's main task is to control some device or process. It usually runs a single or a embedded processer to create an embedded processor for fuzzy control is very effective. Table I shows the measured speed of the inference by a MIPS R3000 microprocessor, a fictitious MIPS R3000 microprocessor with min and max instructions, and a UNC/MCNC ASIC fuzzy inference chip. The software that used on microprocessors is a simulator of the ASIC chip. The first row is the computation time in seconds of 6000 inferences using 51 rules where each fuzzy set is represented by an array of 64 elements. The second row is the time required to perform a single inference. The last row is the fuzzy logical inferences per second (FLIPS) measured for ach device. There is a large gap in run time between the ASIC and software approaches even if we resort to a specialized fuzzy microprocessor. As for design time and cost, these two approaches represent two extremes. An ASIC approach is extremely expensive. It is, therefore, an important research topic to design a specialized computing architecture for fuzzy applications that falls between these two extremes both in run time and design time/cost. TABLEI INFERENCE TIME BY 51 RULES {{{{Time }}{{MIPS R3000 }}{{ASIC }}{{Regular }}{{With min/mix }}{{6000 inference 1 inference FLIPS }}{{125s 20.8ms 48 }}{{49s 8.2ms 122 }}{{0.0038s 6.4㎲ 156,250 }} }}

  • PDF

A Study on the Fabrication and Comparison of the Phantom for CT Dose Measurements Using 3D Printer (3D프린터를 이용한 CT 선량측정 팬텀 제작 및 비교에 관한 연구)

  • Yoon, Myeong-Seong;Kang, Seong-Hyeon;Hong, Soon-Min;Lee, Youngjin;Han, Dong-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.737-743
    • /
    • 2018
  • Patient exposure dose exposure test, which is one of the items of accuracy control of Computed Tomography, conducts measurements every year based on the installation and operation of special medical equipment under Article 38 of the Medical Law, And keep records. The CT-Dose phantom used for dosimetry can accurately measure doses, but has the disadvantage of high price. Therefore, through this research, the existing CT - Dose phantom was similarly manufactured with a 3D printer and compared with the existing phantom to examine the usefulness. In order to produce the same phantom as the conventional CT-Dose phantom, a 3D printer of the FFF method is used by using a PLA filament, and in order to calculate the CTDIw value, Ion chambers were inserted into the central part and the central part, and measurements were made ten times each. Measurement results The CT-Dose phantom was measured at $30.44{\pm}0.31mGy$ in the periphery, $29.55{\pm}0.34mGy$ CTDIw value was measured at $30.14{\pm}0.30mGy$ in the center, and the phantom fabricated using the 3D printer was measured at the periphery $30.59{\pm}0.18mGy$, the central part was $29.01{\pm}0.04mGy$, and the CTDIw value was measured at $30.06{\pm}0.13mGy$. Analysis using the Mann - Whiteney U-test of the SPSS statistical program showed that there was a statistically significant difference in the result values in the central part, but statistically significant differences were observed between the peripheral part and CTDIw results I did not show. In conclusion, even in the CT-Dose phantom made with a 3D printer, we showed dose measurement performance like existing CT-Dose phantom and confirmed the possibility of low-cost phantom production using 3D printer through this research did it.