• Title/Summary/Keyword: Peripheral Device

Search Result 158, Processing Time 0.024 seconds

A Study on the Peripheral Devices Search Algorithm Design of IoT Environment (IOT 환경의 주변 디바이스 탐색 알고리즘 설계)

  • Hwang, Jong-sun;Kim, Wung-Jun;Jeong, In-Yong;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.606-608
    • /
    • 2015
  • In order to bear a relationship between the devices in the IoT environment whereby the task of navigating the device and relationship should be preceded before. The new device transmits a search signal in order to find a device and a peripheral device that receives this will determine the distance information of the device and determines the intensity of the transmitted signal. M2M (Machine to Machine) method has been used in conventional sends the search signal to all of the peripheral devices in a single device, a peripheral device that is greater the search time becomes long, a problem that a loss of information, the more devices that are far there is. In this paper, a method to compensate for problems of existing methods of M2M devices and new shortening of the search time when the search for the peripheral device, an algorithm to reduce the information loss of time to send and receive signals from the navigation device and away proposals were discussed and used in the field.

  • PDF

Peripheral Blood Flow Velocity and Peripheral Pulse Wave Velocity Measured Using a Clip-type Pulsimeter Equipped with a Permanent Magnet and a Hall Device

  • Kim, Keun-Ho;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.20 no.1
    • /
    • pp.47-51
    • /
    • 2015
  • We measured radial arterial pulse signals using a prototype of a clip-type pulsimeter equipped with a permanent magnet and a Hall device, which produced signals through a voltage-detecting circuit. The systolic peak time and the reflective peak time for a temporally pulsed signal were analyzed for an arbitrary pulse wave at one position of a small permanent magnet. The measured value of the peripheral pulse wave velocity was about 1.25-1.52 m/s, demonstrating the accuracy of this new method. To measure the peripheral blood flow velocity, we simultaneously connected the radial artery pulsimeter to a photoplethysmography meter. The average value of the peripheral blood flow velocity was about 0.27-0.50 m/s.

Thermal Burn Injury from a Forced-Air Warming Device in an Anesthetized Dog with Peripheral Hypoperfusion

  • Lee, Sungin;Lee, Aeri;Lee, Maro;Kim, Wan Hee
    • Journal of Veterinary Clinics
    • /
    • v.37 no.6
    • /
    • pp.331-335
    • /
    • 2020
  • A 13-year-old female Poodle presented with gallbladder rupture caused by a mucocele and hypoperfusion. The animal had a thermal burn injury caused by a forced-air warming device used for hypothermia during surgery. This could be attributed to two causes. First, the forced-air warming device was used with direct hosing, without attachment to an air blanket, and the heat was concentrated in a single area. Second, perioperative peripheral hypoperfusion hampered heat dissipation and increased the susceptibility to a burn injury. These findings suggest that an air blanket should be used with a forced-air warming device according to the manufacturer's instructions. Furthermore, patients with peripheral hypoperfusion are at a higher risk of burn injuries and require close monitoring.

Peripheral Device Test with AMBA System (AMBA 시스템을 통한 주변장치 테스트)

  • Kim, Woong;Jung, Gab-Cheon;Park, Seong-Mo
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.317-320
    • /
    • 2002
  • Recently, AMBA(Advanced Microcontroller Bus Architecture) is used as common system bus at embedded system. In this paper, we described test method of peripheral device which is connected to AMBA according to the bus interface defined by AMBA protocol We implemented one of the APB(Advanced Peripheral Bus) peipheral module, GPIO(General Purpose Input/output), and tested its functionality as il is connected to the AMBA system.

  • PDF

Design of the Unified Peripheral Device with Advanced Functions for Motor Control using VHDL (VHDL을 이용한 향상된 기능을 가지는 모터 제어용 주변장치의 통합 설계)

  • 박성수;박승엽
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.5
    • /
    • pp.354-360
    • /
    • 2003
  • For the convenient use of high performance microprocessor in motor control, peripheral devices are needed for converting its control signals to compatible ones for motor drive. Customized devices are not plentiful far these purposes and their functions do not usually satisfied designers specification. The designers used to implement these functions on FPGA or CPLD using hardware description language. Then, in this case unessential programs are needed for control the peripherals. In this paper, a unified device model that links peripheral devices, including especially the pulse width modulation controller and the quadrature encoder interface device, to an interrupt controller is proposed. Advanced functions of peripherals could be achieved by this model and unessential programs can be simplified. Block diagrams and flowcharts are presented to illustrate the advanced functions. This unified device was designed using VHDL. The simulation results were presented to demonstrate the effectiveness of the proposed scheme.

A study on the development of oxygen measurement device for diagnosis of peripheral vascular disease in lower extremity (하지 (下脂) 조직내의 말초 혈관계 질환 진단을 위한 산소 측정장치의 개발에 관한 연구)

  • 임현수;이준규;박동철
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.9-15
    • /
    • 1999
  • The oxygen saturation of blood can be measured by the difference absorption in optical spectra of Hb and Hb0$_2$, as the well known previous study. In this study we developed the non-invasive oxygen measurement device for diagnosis of peripheral vascular disease in lower extremity using infrared and red LED which produce a peak spectral emission at a wavelength of 660 nm, and 940 nm. To evaluate the clinical application of the oxygen measurement device, we performed lower extremity study to measure the oxygen changes in response to physiological changes within biological tissue. The results showed that oxygen saturation of blood in biological tissue can be monitored from the separation arrangement light source and detector.

  • PDF

Implementation of a Bluetooth-LE Based Wireless ECG/EMG/PPG Monitoring Circuit and System (블루투스-LE 기반 심전도/근전도/맥박 무선 모니터링 회로 및 시스템 구현)

  • Lee, Ukjun;Park, Hyeongyeol;Shin, Hyunchol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.261-268
    • /
    • 2014
  • This paper presents a electrocardiogram(ECG), electromyogram(EMG), and Photoplethysmography(PPG) signal wireless monitoring system based on Bluetooth Low Energy (BLE). ECG and EMG sensor interface analog front-end circuits are designed by using off-the-shelf parts. Texas Instruments(TI)'s CC2540DK is used for BLE-based communication. Two CC2540DK modules are used as Peripheral and Central nodes. In peripheral device, vital signals are acquired by the analog front-ends and fed to ADC for analog-to-digital conversion. The peripheral transmitts the data through the air to the central device. The central device receive the data and sends them to PC using UART. GUI is designed using Labview for displaying the acquired vital signals. The developed system can be used for future ubiquitous wireless healthcare system based on bluetooth 4.0.

A Design on the Extended ATA Interface for Multimedia Systems (멀티미디어 시스템을 위한 확장된 ATA 인터페이스 설계)

  • Ku Dae sung;Kim Jong bin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.4A
    • /
    • pp.345-349
    • /
    • 2005
  • In this paper, the enhanced ATA(AT Attachment Interface with Extension) interface that combines the price of ATA and intelligent operation of SCSI(Small Computer System Interface) is realized both performance and structure of general interface used to connect peripheral devices that are used in PC(Personal Computer). SCSI bus is for peripheral devices that have intelligent operation. It is excellent bus that has well-arranged command system and stable hardware structure. But is aspect of price this peripheral device has the difficulty in purchase because there is price difference more than two times compared with ATA peripheral device. Whereas, although ATA peripheral device had low performance in the early period, after the improvement its speed has almost etched to SCSI and its price is also excellent. In this paper, the enhanced interface structure to fulfill price and performance was suggested and materialized as the hardware using such two advantages.

Design and Implementation of Bus for 32-bit RISC Microprocessor (32-bit RISC마이크로프로세서를 위한 버스 설계 및 구현)

  • 양동훈;곽승호;이문기
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.333-336
    • /
    • 2002
  • This paper purpose design and implementation of system bus for the effective interconnection between peripheral device and 32-bit microprocessor. The designed system bus support general bus protocol. Also, it is optimized for 32-bit microprocessor. It is divided into two system. high performance system bus and Peripheral system bus.

  • PDF

Recording and Analysis of Peripheral Nerve Activity Using Multi-Electrode Array (다채널 신경전극 어레이를 이용한 말초 신경신호의 측정 및 분석)

  • Chu, Jun-Uk
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.4
    • /
    • pp.279-285
    • /
    • 2016
  • Reliable recording and analysis of peripheral nerve activity is important to recognize the user's intention for controlling a neuro-prosthetic hand. In this paper, we present a peripheral nerve recording system that consisted of an intrafascicular multi-electrode array, an electrode insertion device, and a multi-channel neural amplifier. The 16 channel multi-electrode array was stably implanted into the sciatic nerve of the rat under anesthesia using the electrode insertion device. During passive movements and mechanical stimuli, muscle and cutaneous afferent signals were recorded with the multi-channel neural amplifier. Furthermore, we propose a spike sorting method to isolate individual neuronal unit. The muscle proprioceptive units were classified as muscle spindle afferents or Golgi tendon organ afferents, and the skin exteroceptive units were categorized as slow adapting afferents or fast adapting afferents. Experimental results showed that the proposed method could be applicable to record and analyze peripheral nerve activity in neuro-prosthetic systems.