• Title/Summary/Keyword: Performance-based Regulation

Search Result 417, Processing Time 0.027 seconds

Land Based Test of Ballast Water Treatment System by Ozonation

  • Park, Sung-Jin;Yoon, Seung-Je;Kim, In-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.383-390
    • /
    • 2010
  • This study is currently giving priority to developing the ship's ballast water treatment system using ozone (Ozone BWTS). The Ozone BWTS was tested in a full scale land-based mobile barge to evaluate performance according to the IMO G8 Guidelines. Test cycles using the mobile-barge were conducted in seawater and brackish water in the vicinity of the Port of Busan and Nakdong River, Republic of Korea. All tests were conducted according to the requirements of the G8 Guidelines. Test results show that the Ozone BWTS meets the Ballast Water Performance Standard contained in Regulation D-2 of the IMO Ballast Water Management Convention, as well as all of the operational, safety, and environmental testing requirements of the G8 Guidelines, as required for type approval of IMO. The study results show that the Ozone BWTS is capable of meeting the Ballast Water Performance Standard under Regulation D-2 of the International Convention for the Control and Management of Ships’ Ballast Water and Sediments, and also the more stringent standards being proposed under US legislation.

Trade-Off Strategies in Designing Capacitor Voltage Balancing Schemes for Modular Multilevel Converter HVDC

  • Nam, Taesik;Kim, Heejin;Kim, Sangmin;Son, Gum Tae;Chung, Yong-Ho;Park, Jung-Wook;Kim, Chan-Ki;Hur, Kyeon
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.829-838
    • /
    • 2016
  • This paper focuses on the engineering trade-offs in designing capacitor voltage balancing schemes for modular multilevel converters (MMC) HVDC: regulation performance and switching loss. MMC is driven by the on/off switch operation of numerous submodules and the key design concern is balancing submodule capacitor voltages minimizing switching transition among submodules because it represents the voltage regulation performance and system loss. This paper first introduces the state-of-the-art MMC-HVDC submodule capacitor voltage balancing methods reported in the literatures and discusses the trade-offs in designing these methods for HVDC application. This paper further proposes a submodule capacitor balancing scheme exploiting a control signal to flexibly interchange between the on-state and the off-state submodules. The proposed scheme enables desired performance-based voltage regulation and avoids unnecessary switching transitions among submodules, consequently reducing the switching loss. The flexibility and controllability particularly fit in high-level MMC HVDC applications where the aforementioned design trade-offs become more crucial. Simulation studies for MMC HVDC are performed to demonstrate the validity and effectiveness of the proposed capacitor voltage balancing algorithm.

The Development of Control Algorithms of D-STATCON for Compensations of AC Voltage and DC Link Voltage and Harmonics Improve the Qeality of Electric Power (전력 품질 향상을 위한 배전용 STATCON의 AC전압, 직류결합 전압 및 고조파 보상 제어알고리즘 개발)

  • 오관일;전영수;이기선;추진부
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.333-337
    • /
    • 1999
  • This paper presents the DQ transfomation space space vector modulation method to devel control algorithm of distribu STATCON(STATic CONdenser) for line volt regulation, dc link voltage regulation harmonics compensation. The Performance an of a PI with ramp comparision and synchro reference frame current controller is carried Based on these analysis, the control perform are desirable to compensate the harmonics a regulate dc link and line voltage of Distrib line.

  • PDF

Public Policy for Hospitals in the United States (미국의 병원정책)

  • Kwon, Soon-Man
    • Korea Journal of Hospital Management
    • /
    • v.3 no.1
    • /
    • pp.238-260
    • /
    • 1998
  • This article describes the theoretical foundations of government policy for hospitals in terms of correcting market failure and enhancing equity. It then discusses the characteristics that desirable payment systems should have, and the effects of the DRG-based prospective payment system on hospital behavior, its financial performance, hospital industry, and health care expenditure. The rationales and impacts of other public policies for hospitals such as antitrust and fair trade regulation, dissemination of practice guidelines and hospital mortality information, regulation of hospital capital investment, and tax policy are also discussed.

  • PDF

Input-Output Feedback Linearizing Controller Design of a Power System Using a Modified Voltage Equation (수정한 전압방정식을 이용한 발전기의 입출력 귀환선형화 제어기 설계)

  • Kim, Seok-Kyoon;Yoon, Tae-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.183-185
    • /
    • 2006
  • This paper presents a SISO nonlinear controller for the power system consisting of a synchronous generator connected to an infinite bus. The proposed controller is based on input-output feedback linearization, with a modified version of the terminal voltage equation used as the output. The resulting closed-loop has no internal dynamics, and thus stability is guaranteed. The controller performance is seen to be effective through simulations.

  • PDF

Performance Limits of Three-Phase Self-Excited Induction Generator (SEIG) as a Stand Alone DER

  • Slimene, Marwa Ben;Khlifi, Mohamed Arbi
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.145-150
    • /
    • 2017
  • This paper present a unified method of steady state performance analysis and limits characteristics of an autonomous three-phase self-excited induction generator (SEIG) driven by a wind turbine under different types of loads and speeds. The proposed method is based on a new mathematical function to solve for the real and imaginary components of the complex equation of the mathematical model. Performances limits, regulation and characteristics of different configurations will be thoroughly examined and compared. The proposed system will be modeled and simulated and the performance limits characteristics will be compared with variable speed and variable capacity.

Robust Controller Design for the Regulation of Currents in a Three-phase Load (3상 부하 전류 제어를 위한 강인한 제어기 설계기법)

  • Jee, Sujung;Jo, Nam-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.7
    • /
    • pp.17-23
    • /
    • 2013
  • The regulation of currents in a three-phase load is an important issue for electric power systems. The most popular conventional method is a decoupling controller that compensates the coupling terms arising from DQ rotating frame transformation. Although the decoupling controller achieves decent performance in the absence of load parameter uncertainties, the variation of parameters causes performance to degrade intolerably. In this paper, we propose to use disturbance observer based controller to improve the control performance in spite of the parameter uncertainties. The computer simulation study validates the effectiveness of the proposed method.

Development of Medium-Duty Diesel Engine with CP3.3 Common Rail - Concept Study and Initial Experimental Work (커먼레일 중형 디젤엔진의 개념설계 및 초기 시험개발)

  • 김만영;허행표;김창일;최규훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.69-74
    • /
    • 2003
  • An experimental feasibility study of the E3.9 engine with CP3.3 and EDC7C was conducted to understand the initial performance and the possibility for EURO-III regulation. ID cycle simulation for concept study was conducted using the BOOST. Also, some basic investigations through such various parameters as injection timing and rail pressure have been carried out to find the feasibility on EURO-III ESC mode. Based on the results, the feasibility of the E3.9 engine for EURO-III characteristics such as performance, emissions, and fuel economy was demonstrated.

Variable-Speed Prime Mover Driving Three-Phase Self-Excited Induction Generator with Static VAR Compensator Voltage Regulation -Part I : Theoretical Performance Analysis-

  • Ahmed, Tarek;Nagai, Schinichro;Soshin, Koji;Hiraki, Eiji;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.1
    • /
    • pp.1-9
    • /
    • 2003
  • This paper deals with the nodal admittance approach steady-state frequency domain analysis of the three-phase self-excited induction generator (SEIG) driven by the variable speed prime mover as the wind turbine. The steady-state performance analysis of this power conditioner designed for the renewable energy is based on the principle of equating the input mechanical power of the three-phase SEIG to the output mechanical power of the variable speed prime mover mentioned above. Us-ing the approximate frequency domain based equivalent circuit of the three-phase SEIG. The main features of the present algorithm of the steady-state performance analysis of the three-phase SEIG treated here are that the variable speed prime mover characteristics are included in the approximate equivalent circuit of the three-phase SEIG under the condition of the speed changes of the prime mover without complex computations processes. Furthermore, a feedback closed-loop voltage regulation of the three-phase SEIG as a power conditioner which is driven by variable speed prime movers such as the wind turbine(WT) employing the static VAR compensator(SVC) circuit composed of the thyristor phase controlled reactor(TCR) and the thyristor switched capacitor(TSC) controlled by the PI controller is designed and considered for wind-turbine driving power conditioner.