• 제목/요약/키워드: Performance tester

검색결과 300건 처리시간 0.023초

Anti-wear performance and life evaluation of wheel bearing type greases

  • Kim Jung-Young;Chung Keun-Wo;Kim Young-Wun;Jo Won-Oh
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2004년도 학술대회지
    • /
    • pp.111-116
    • /
    • 2004
  • Li-complex and urea type greases (each 10 species) which were furnished by Chang-Am LS, analyzed anti-wear performance into fretting wear tester & four-bail wear tester. from the results of fretting wear test, the wear volume of Li-complex greases are $4.6\~8.9mg\;and\;8.3\~14.4mg$ with the test of urea greases. The anti-wear performance for 4-ball wear test of greases produced results around 0.5mm at the value of WSD. The grease life performance were evaluated by SKF-ROF Grease Tester and wheel bearing life tester. From the results of SKF-ROF tester, the life performance evaluated by whole working time produced results $50\~300hr$ with the Li-complex greases and 100-1000hr with the urea greases. That is to say, in spite of severe condition at the higher of $10^{\circ}C$ reaction temp, the life performance with Urea type greases are much superior to Li-complex type greases. Prior to wheel bearing life tester, the grease selected performance evaluation(=anti-wear test) are tested by wheel bearing tester. In this results, we can confirm results those are similar with SKF-ROF tester. In this study, we can draw two major conclusions, one is that Li-complex greases are superior to urea greases with anti-wear properties and the other is that urea greases are much superior to Li-complex greases with life performance.

  • PDF

유동안정화 장치가 홴 테스터의 성능에 미치는 영향 (Effects of Flow Settling Means on the Performance of Fan Tester)

  • 최영석;김덕수;윤준용
    • 한국유체기계학회 논문집
    • /
    • 제8권5호
    • /
    • pp.29-34
    • /
    • 2005
  • In this study, the effect of flow settling means on the performance of fan tester were numerically investigated by using a computational fluid dynamics (CFD). The airflow rate was calculated from the pressure differential across a flow nozzle in the measuring plane and the flow settling means were generally installed in the chamber of the fan tester to provide proper airflow patterns ahead of the measuring plane. The predicted nozzle differential pressures with uniform inlet velocities were compared with the values of the ANSI/AMCA 210-99 to verify the performance of the commercial CFD code CFX 5.6. The influence of flow settling means on the measurement of airflow rate in a fan tester were discussed with various porosities and inlet jet velocities. The results obtained show that the proper band of porosities exist to meet the AMCA standard in a specified inlet jet velocity.

유동안정화 장치가 홴 테스터의 성능에 미치는 영향 (Effects of Flow Settling Means on the Performance of Fan Tester)

  • 최영석;김덕수;윤준용
    • 한국유체기계학회 논문집
    • /
    • 제9권4호
    • /
    • pp.43-48
    • /
    • 2006
  • In this study, the effect of flow settling means on the performance of fan tester were numerically investigated by using a computational fluid dynamics(CFD). The airflow rate was calculated from the pressure differential across a flow nozzle in the measuring plane and the flow settling means were generally installed in the chamber of the fan tester to provide proper airflow patterns ahead of the measuring plane. The predicted nozzle differential pressures with uniform inlet velocities were compared with the values of the ANSI/AMCA 210-99 to verify the performance of the commercial CFD code CFX 5.6. The influence of flow settling means on the measurement of airflow rate in a fan tester were discussed with various porosities and inlet jet velocities. The results obtained show that the proper band of porosities exist to meet the AMCA standard in a specified inlet jet velocity.

주행 집전계 시험기의 주행 대차용 선형 유도전동기 설계에 관한 연구 (A Study on Design of Linear Induction Motor in Dynamic Tester for Catenary-current Collection)

  • 함상환;조수연;이주
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.771-775
    • /
    • 2011
  • This paper presents design process of linear induction motor in dynamic tester for catenary-current collection. To minimize length of rail for dynamic tester for catenary-current collection, accelerating performance of the linear induction motor is very important. So the design process of linear induction motor considered in this paper is different with general design process of linear induction motor, because dynamic tester has three type driving region, as accelerating region, constant speed region, and braking region. Considering accelerating performance of motor, distance and time from starting point to constant speed region were concerned for load condition of motor. Designed linear induction motor was analyzed by 2-dimensional finite element method. Using mechanical dynamics simulation with analysis result of 2-dimensional finite element method and accelerating performance of designed motor was proved.

무향팬테스터를 이용한 냉장고용 팬 성능/소음 측정 (Measuring performance and SPL of refrigerator fan using anechoic fan tester)

  • 정정교;이준화;주재만;강정훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.253-256
    • /
    • 2004
  • Acoustical noise at low frequency range (below 500Hz) of refrigerator result from fans which are inside of the refrigerator. In generally to evaluate and apply to refrigerator it is recommended that acoustical noise and fluidic performance of the fan were measured simultaneously. To do that twin-room type anechoic wind tunnel was needed. But constructing twin room type anechoic wind tunnel was very expensive and estimation of small refrigerator fan performance was not easy. So in this paper we composed anechoic fan tester. A successful noise and performance measurement was performed using the anechoic fan tester. Existing 22 kinds of refrigerator fan were investigated and mapped into one database. Refrigerator duct pressure resistance were measured and reflected into the fan database to find out appropriate fan. Through the application of fan database, the refrigerator became less noise compared to current one and these data shows what is the best way to reduce fan noise.

  • PDF

자동제어계측을 이용한 송풍기 성능시험 (Fan Performance Test with Automatic Control and Measurement)

  • 최영석;김진권
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.373-378
    • /
    • 2003
  • In this paper, build up of fan performance tester in KITECH was introduced. The fan tester was set up based on AMCA standards 210-99, ANSI/ASHRAE 51-1999 with maximum flowrate within $1000\;m^{3}/min$. Both of inlet and outlet chamber setup with multiple nozzles described in AMCA 210 were established. The development of fully automatic control and measurement system are described. With this system, the accuracy of fan performance test can be maintained through the various flowrate and the uncertainty can be reduced.

  • PDF

차세대 방 SIP 서버 시험을 위한 성능 지표 및 시험기 구현 (Definition of Performance Indices and Unplementation of Tester for SIP Servers in Next Generation Networks)

  • 김용권;박준형;기장근;이규호;최길영;최진규
    • 한국통신학회논문지
    • /
    • 제29권4B호
    • /
    • pp.411-423
    • /
    • 2004
  • 본 논문은 차세대 네트워크에 사용되는 SIP(Session Initiation Protocol) 프로토콜에 대한 성능 시험시 필요한 시험방안과 성능 지표들을 정의하고 성능 지표에 영향을 줄 수 있는 요소들을 추출하였으며 이를 검증하기 위한 시험기를 구현하였다. 구현된 시험기를 통해 SIP 서버에 대한 성능 시험을 수행하여 SIP 서버들에 대한 성능 평가를 실시하였다. SIP 서버 시험의 성능 지표는 크게 서버의 단위시간당 처리율과 트랜잭션 지연시간. 호 설정의 성공과 실패율로 구분할 수 있으며, 성능 지표에 영향을 줄 수 있는 요소로는 사용자 수와 전송 프로토콜 데이터베이스 액세스 방식. DNS 방식. 호 발생 패턴. 트랜잭션의 정의. 패킷의 크기 등이 있다. 구현된 시험기를 통해 등록 서버와 프록시 서버에 대한 시험을 수행하여 시험대상에 대한 성능 평가를 실시하였으며 시험을 통해 구현된 시험기를 검증하고 제시된 성능 지표와 입력 파라미터에 대한 타당성을 검증하였다. 본 논문에서 규정한 성능 파라미터와 성능 지표는 차세대 네트워크의 주요 구성요소인 SIP 서버 시스템의 성능 평가시 유용한 지표로 사용될 수 있을 것이다.

수직으로 설치된 비균질 평판 단열재용 성능시험장치 개발 (Development of Thermal Performance Tester for Non-Homogeneous Insulation Pannels Installed Vertically)

  • 오홍영;송기오;전현익;조선영
    • 설비공학논문집
    • /
    • 제28권4호
    • /
    • pp.153-157
    • /
    • 2016
  • In case of metal insulation, which is produced by stacking stainless steel sheets and air layers in a multi-stack manner at a specific thickness, insulation performance will be evaluated based on thermal transmittance rather than the intrinsic physical properties of each material such as thermal conductivity. However, there is no standard for measuring thermal transmittance targeted for non-homogeneous insulation which is used in relatively high temperature conditions such as a power station. In this study, the thermal conductivity of homogeneous insulation acquired by the standardized guard hot plate method and the thermal conductivity of homogeneous insulation measured by the newly developed performance tester were compared to verify the confidence level of the tester. As a result, thermal conductivity acquired by the newly developed thermal transmittance tester was about 6% higher than the thermal conductivity measured by the existing guard hot plate method under the anticipated service temperature conditions.

초고압 압력센서용 다이어프램 설계 및 PZT 구동 변형시험기를 이용한 성능평가 (Design of Diaphragm for Ultra High Pressure Sensors and Its performance Evaluation Using a PZT Actuated Deformation Tester)

  • 윤대중;안중환
    • 센서학회지
    • /
    • 제28권1호
    • /
    • pp.58-63
    • /
    • 2019
  • This research aims at designing a diaphragm made of SUS316L stainless steel for ultra high pressure sensors and evaluating its performance with a PZT driven deformation tester instead of high pressure chamber testing up to 100 MPa. Finite element method analysis indicates that the optimum thickness of a flat diaphragm is 1.5 mm not only to secure safety of sensors up to 100 MPa but also to enhance displacement measuring sensitivity. For this thickness, the maximum displacement at the center of the diaphragm is $5.3{\mu}m$. The PZT actuator must offer a force of 1,669 N to create a pressure of 100 MPa at the diaphragm surface in order to obtain a displacement of $5.3{\mu}m$. The performance evaluation by the PZT driven tester demonstrates nearly the same results as the same results as the sensors tested in the ultra high pressure chamber.

비소음 측정을 이용한 저소음 축류홴 설계 (Design of Low Noise Axial Flow Fan Using Specific Sound Presssure Level)

  • 김창준;이동익
    • 소음진동
    • /
    • 제10권5호
    • /
    • pp.873-879
    • /
    • 2000
  • Experimental investigation was conducted to study the effects of pitch angle maximum camber on the performance and noise of an axial-flow fan used in outdoor-unit of air -conditioner. For this study the axial-flow fan whose pitch angle can be varied was made and the Specific sound Pressure Level and other coefficients were measured using the anechoic fan tester. It is found that pitch angle affects more severly than the maximum camber on the fan performance. On the while the maximum camber affects much on the specific sound power level. Present results show that it is important to choose the optimum pitch angle and maximum camber to design the high-performance and low-noise axial-flow fan and specific noise measured in the anechoic fan tester can be sued effectively for the design of low-noise fan.

  • PDF