• 제목/요약/키워드: Performance standards

검색결과 2,356건 처리시간 0.031초

특수구급차 성능 개선을 위한 조사 연구 (A study on improving the performance of special ambulances)

  • 윤병길;양현모;김경용
    • 한국응급구조학회지
    • /
    • 제26권1호
    • /
    • pp.87-99
    • /
    • 2022
  • Purpose: This study aimed to provide basic data for the improvement of the standards related to the performance improvement of the firefighting equipment standards for special ambulances. Methods: Among the domestic firefighting equipment standards, the special ambulance standard was compared with the NFPA 1917 standard for the United States automobile ambulance 2019 and European Union European standard EN 1789 medical vehicle and its equipment, a road ambulance. Results: Anti-skid performance based on indoor noise standards, performance standards for interior lights, seat belt warning device, child car seat fixing device, safety handle, auxiliary footrest, and flooring materials should be supplemented. Conclusion: It is necessary to strengthen the production and performance standards for improvement to a level corresponding to the national standards, such as the United States and European Union.

The Effect of Incentives on the Performance of International IT Standardization Experts

  • Kang, Shin-Won;Park, Hye-Jin;Park, Ki-Shik
    • ETRI Journal
    • /
    • 제29권2호
    • /
    • pp.219-230
    • /
    • 2007
  • In this paper, we investigate the determinant factors of performance of global standardization experts in their standardization activities. Standards experts of various nationalities were surveyed to assess incentives that may positively influence the performance of standards professionals. As a basis for this study, we make three main assumptions. First, incentives can be important determinant factors of performance among standards experts. Second, standardization is in the public interest, insofar as the efficiency gains resulting from standardization benefit society as a whole. Third, based on this assumption that standardization is in the public interest, we propose that performance determinants for standardization activities tend to be non-monetary in nature rather than monetary. We find that, in order to improve performance among international standards experts, a better understanding of their aspirations and needs must be gained so that appropriate incentives may be proposed to them. Our analysis reveals that the two most important determinant factors of performance are the recognition of the professional status of international standards experts, and an environment providing support systems to help them perform to their fullest potential.

  • PDF

경영시스템 도입 중소기업의 품질이행율 향상을 위한 품질기록 관리운영의 표준화 사례연구 (Introduction of Management System Case Study on Standardization of Quality Record Management to Improve Quality Performance Rate of SMEs)

  • 조철희;박병화;박진이
    • 품질경영학회지
    • /
    • 제47권4호
    • /
    • pp.911-926
    • /
    • 2019
  • Purpose: In an infinite market competition, companies are adopting management systems to gain a competitive advantage. The expectancy effect of the management system is management performance improvement and accurate measurements. These can be made through quality records with integrity and maintainability. This paper examines the operation of records management standards, which are records, storage and management standards for quality records to understand the needs of records management standards and empathize with their needs. Methods: This paper examines PEC's (Pields Engineering Co., Ltd.) specific processes and standards for integrating individual management systems and establishing records management standards. We also look at the specific features of the Search Tool and Document Storage Management Standards that support records management standards. Results: The integration process of PEC's individual management system consists of five steps. A PDCA-based process was established to erode the confusion and inefficiencies caused by overlap between individual management systems. Also, by accurately grasping corporate competence, PEC established a record management standard suitable for the characteristics of the company. PEC's records management standards are used as a useful standard for organizing quality records, and have an impact on management performance improvement. Conclusion: PEC's records management standards enable the verification of quality performance rates and performance measures. Companies can implement appropriate quality improvement strategies based on the numbers identified by introducing records management standards. Companies can succeed in improving management performance when operating quality management that combines performance measurement techniques and records management standards.

투약과 수혈간호의 간호과정 적용 평가도구 개발 (Development of the Nursing Process Based Performance Measurement Tool for Medication Management and Blood Transfusion)

  • 김금순;김진아;권소희;송말순
    • 임상간호연구
    • /
    • 제16권1호
    • /
    • pp.177-196
    • /
    • 2010
  • Purpose: This study was conducted to develop the nursing process based performance measurement tool and the evidence based care standards for nursing care in medication management and blood transfusion. Methods: The care standards and performance measurement tool were drafted through comprehensive review of relevant literature, national guidelines, hospital protocols, and standards of recognized international accrediting bodies. The proposed care standards and performance measurement tool were reviewed by the panel of experts and refined based on the panel's suggestions. Final care standards and performance measurement tool were validated by surveying the hospital nurses. Results: All items of the performance measurement tool for medication management and blood transfusion were evaluated appropriate. All contents of care standards and the measurable elements except the evaluation of discharge education were appropriate. The performance measurement tool developed in this study was found to be acceptable as a tool to evaluate quality of nursing care in medication management and blood transfusion. Conclusion: The outcomes of this study including the performance measurement tool and evidence based care standards would be the important indicators to monitor whether necessary nursing care is implemented and be the useful primary resources to improve quality of nursing care services.

안전인증기준 성능화에 대한 기반 연구 (A Basic Study on the Performance Improvement of Safety Certification Standards)

  • 변정환;김정곤
    • 한국재난정보학회 논문집
    • /
    • 제17권3호
    • /
    • pp.487-499
    • /
    • 2021
  • 연구목적: 본 논문은 미래 산업발전과 환경변화에 대한 안전인증기준의 합리화를 위하여, 안전인증기준의 성능화에 대한 문제점을 검토하고 개선방향을 제시하는 것을 목적으로 한다. 연구방법: 문헌조사 및 실무자 면담조사를 통해 안전인증 체계에 대한 문제점과 한계점을 정리하고, 안전인증기준의 현황을 설계기준과 성능기준 그리고 세부적인 기준으로 분류하여 현황 분석을 실시한다. 그리고 조사 및 분석한 결과를 종합하여 안전인증기준의 성능화를 위한 개선사항을 제시한다. 연구결과: 조사를 통해 안전인증의 문제점과 한계점은 정부주도의 인증체계운용, 정형화된 인증기준, 인증개선에 장시간이 소요, 인증기준 마련체계의 부실, 업계의견 반영의 부족 등 6가지로 정리 할 수 있었다. 그리고 인증기준을 성능 및 설계기준으로 구분하여 분석한 결과, 기계 및 설비, 방호장치의 경우, 설계기준이 69.7% 및 64.9%로 높게 나타난 반면, 보호구의 경우 성능기준이 61.1%로 높게 나타났다. 설계기준 중심의 안전인증기준을 성능화하기 위해서는 인증기준의 성능화 가능성 판단, 검사시험방법의 규정 가능성 판단 등이 전제되어야 한다. 그리고 성능화를 위해서는 제조물책임법강화, 시장모니터링 등 체계화, 인증시험 업무의 분산, 민간의 인증기준 마련 참여 등의 제도기반 및 인프라 구축이 필요한 것으로 검토 되었다. 결론: 연구를 통해 우리나라 안전인증제도의 문제점과 한계점을 정리하고 성능화 필요성에 대하여 검토 하였다. 안전인증기준의 성능화는 법령정비, 인프라 구축 등 준비 작업이 필요한 사항으로 중장기적인 추진이 필요하다. 또한 전체 안전인증기준의 성능화 보다는 인증대상 품목별로 성능화 요건을 검토하여 추진하고, 세부적인 사항은 추가적인 연구를 통해 구체화해 나가야 한다.

유리섬유강화슬래그(Glass-fiber Reinforced Slag)의 경관석 성능 적합성 평가 (The Suitability Assessment of Performance Standards on Landscaping Rocks of GRS(Glass Fiber Reinforced Slag) Panels)

  • 윤복모;이용복;구본학
    • 한국환경복원기술학회지
    • /
    • 제16권2호
    • /
    • pp.127-135
    • /
    • 2013
  • This study was carried out to verify the suitability of GRS(Glass-fiber Reinforced Slag) as natural type landscape stone according to the material property and structural safety performance standards. The structural safety performance of the GRS panel showed 12.4MPa and 16.2MPa each in flexural strength at 2 and 3% content of glass fiber while the flexural strength at 4 and 5% of glass fiber content showed 26.9MPa, and 30.2MPa, respectively, all satisfying the standards. In addition, air-dried gravity was found to be 1.82~1.89 in measuring range at 2~5% level of glass fiber content, satisfy the existing standards 1.8~2.3. In structural safety performance, the range of flexural strength consequent on glass fiber content was surveyed to be 12.8~30.2MPa, all satisfying the performance standards, while 10MPa and more while the compressive strength range was found to be 41.5~53.3MPa, all satisfying the performance standards, 40~60MPa. This study judged the suitability of only the items for a property of matter of landscape stone GRS by applying the natural-form landscape stone GFRC material standard, but in case an installation constructed with GRS material comes into existence later, there should be comprehensive performance guidelines through the research on durability, landscape performance and environmental and ecological performance.

이륜자동차 제동장치 검사기준에 관한 연구 (Study on the Inspection Standards of Motorcycle Brake System)

  • 임재문;홍승준;하태웅
    • 자동차안전학회지
    • /
    • 제8권4호
    • /
    • pp.18-23
    • /
    • 2016
  • The objective of this study is to present the inspection standards of motorcycle brake system affecting motorcycle traffic accident. The inspection standards of motorcycle brake system recommended by CITA (International Motor Vehicle Inspection Committee) are studied. The brake performance for preventing the traffic accident is assessed by the brake efficiency. Considering the KMVSS (Korean Motor Vehicle Safety Standards) and the inspection standards of CITA, United Kingdom and Japan, the brake performance in the inspection standards of motorcycle is suggested. It is recommended that the efficiency of independent front and rear brakes are 40% and 27%, respectively. It is recommended that the efficiency of combined front and rear brakes is 50%.

자율청소로봇 성능평가 표준화에 관한 연구 (A Study on Standardization of Performance Evaluation for Autonomous Cleaning Robot)

  • 유재창;홍주표;임성수;이순걸;박광호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1054-1059
    • /
    • 2005
  • To support the expansion of the autonomous robot market, the establishment of evaluation standards of the robot performance are essential. In this paper, to venture the standardization of the performance evaluation of the autonomous robot, the authors take the autonomous cleaning robot(ACR) as the initial stepping stone. Recently, the ACR has been being developed and marketed actively in many countries including Korea and it believes to be the fore-runner among various types of autonomous robot products. Standards of the performance evaluation for the ACR could be easily modified and applied to other autonomous robots. This paper formulates and suggests a group of standards for the performance evaluation based on a evaluation platform for the ACR. The newly developed performance evaluation platform has been designed to include all the important aspects of living environments in reality. In the platform the performance of the ACR is measured in terms of mobility, cleaning performance, avoidance of obstruction(safety), and operation noise. A few commercially available ACR products are collected and tested in the evaluation platform and compared against the performance evaluation standards formulated.

  • PDF

Comparison of Test Standards for the Performance and Safety of Agricultural Tractors: A Review

  • Kabir, Md. Shaha Nur;Chung, Sun-Ok;Kim, Yong-Joo;Shin, Sung-Hyun
    • Journal of Biosystems Engineering
    • /
    • 제39권3호
    • /
    • pp.158-165
    • /
    • 2014
  • Purpose: The objective of this paper was to compare test standards regarding the performance and safety of agricultural tractors to identify the differences in test conditions, measurement tolerances, and test procedures. Based on the comparison, some recommendations were proposed for possible revisions or improvements to current tractor test standards. Methods: The test standards and codes of major standards development organizations (SDOs), such as the Organization for Economic Cooperation and Development (OECD), the International Organization for Standardization (ISO), the American Society of Agricultural and Biological Engineers (ASABE), EC type approval, and the board of actions of the Nebraska Tractor Test Laboratories (NTTL), were selected and analyzed. Comparison of the test standards: The ISO provides references for fuel and lubricants for tractor tests, and the OECD provides additional measurements for calculating fuel consumption characteristics during the power take-off (PTO) tests. The ISO, EC type approval, and the ASABE provide PTO protective device and the safety requirements. During drawbar power tests, seven transmission ratios are selected for fully automatic transmissions, according to the OECD. In case of hydraulic lift tests, ISO 789-2 and OECD Code 2 advise the use of a static lift force, while SAE J283 advises the use of additional dynamic lift capacity tests for a better representation of in-field operations. The OECD, the ISO, and EC type approval determine the seat index point (SIP), whereas the ASABE determines the seat reference point (SRP) for roll-over protective structure (ROPS) tests. Diversified measurement tolerances were among the braking performance test standards. The European Union (EU) has developed daily limits for vibration exposures with adaptations from ISO 2631-1. Electromagnetic compatibility evaluations are emerging of high-efficiency tractors due to the long-term conformance to electromagnetic emissions and interferences. Comparisons of tractor test standards discussed in this paper are expected to provide useful information for tractor manufacturers and standards development personnel to improve the performance and safety test standards of tractors.

Effects of Expert-Determined Reference Standards in Evaluating the Diagnostic Performance of a Deep Learning Model: A Malignant Lung Nodule Detection Task on Chest Radiographs

  • Jung Eun Huh; Jong Hyuk Lee;Eui Jin Hwang;Chang Min Park
    • Korean Journal of Radiology
    • /
    • 제24권2호
    • /
    • pp.155-165
    • /
    • 2023
  • Objective: Little is known about the effects of using different expert-determined reference standards when evaluating the performance of deep learning-based automatic detection (DLAD) models and their added value to radiologists. We assessed the concordance of expert-determined standards with a clinical gold standard (herein, pathological confirmation) and the effects of different expert-determined reference standards on the estimates of radiologists' diagnostic performance to detect malignant pulmonary nodules on chest radiographs with and without the assistance of a DLAD model. Materials and Methods: This study included chest radiographs from 50 patients with pathologically proven lung cancer and 50 controls. Five expert-determined standards were constructed using the interpretations of 10 experts: individual judgment by the most experienced expert, majority vote, consensus judgments of two and three experts, and a latent class analysis (LCA) model. In separate reader tests, additional 10 radiologists independently interpreted the radiographs and then assisted with the DLAD model. Their diagnostic performance was estimated using the clinical gold standard and various expert-determined standards as the reference standard, and the results were compared using the t test with Bonferroni correction. Results: The LCA model (sensitivity, 72.6%; specificity, 100%) was most similar to the clinical gold standard. When expert-determined standards were used, the sensitivities of radiologists and DLAD model alone were overestimated, and their specificities were underestimated (all p-values < 0.05). DLAD assistance diminished the overestimation of sensitivity but exaggerated the underestimation of specificity (all p-values < 0.001). The DLAD model improved sensitivity and specificity to a greater extent when using the clinical gold standard than when using the expert-determined standards (all p-values < 0.001), except for sensitivity with the LCA model (p = 0.094). Conclusion: The LCA model was most similar to the clinical gold standard for malignant pulmonary nodule detection on chest radiographs. Expert-determined standards caused bias in measuring the diagnostic performance of the artificial intelligence model.