• Title/Summary/Keyword: Performance limits

Search Result 1,127, Processing Time 0.023 seconds

Performance of the combined ${\bar{X}}-S^2$ chart according to determining individual control limits (관리한계 설정에 따른 ${\bar{X}}-S^2$ 관리도의 성능)

  • Hong, Hwi Ju;Lee, Jaeheon
    • The Korean Journal of Applied Statistics
    • /
    • v.33 no.2
    • /
    • pp.161-170
    • /
    • 2020
  • The combined ${\bar{X}}-S^2$ chart is a traditional control chart for simultaneously detecting mean and variance. Control limits for the combined ${\bar{X}}-S^2$ chart are determined so that each chart has the same individual false alarm rate while maintaining the required false alarm rate for the combined chart. In this paper, we provide flexibility to allow the two charts to have different individual false alarm rates as well as evaluate the effect of flexibility. The individual false alarm rate of the ${\bar{X}}$ chart is taken to be γ times the individual false alarm rate of the S2 chart. To evaluate the effect of selecting the value of γ, we use the out-of-control average run length and relative mean index as the performance measure for the combined ${\bar{X}}-S^2$ chart.

Human-Induced Vibrations in Buildings

  • Wesolowsky, Michael J.;Irwin, Peter A.;Galsworthy, Jon K.;Bell, Andrew K.
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.1
    • /
    • pp.15-19
    • /
    • 2012
  • Occupant footfalls are often the most critical source of floor vibration on upper floors of buildings. Floor motions can degrade the performance of imaging equipment, disrupt sensitive research equipment, and cause discomfort for the occupants. It is essential that low-vibration environments be provided for functionality of sensitive spaces on floors above grade. This requires a sufficiently stiff and massive floor structure that effectively resists the forces exerted from user traffic. Over the past 25 years, generic vibration limits have been developed, which provide frequency dependent sensitivities for wide classes of equipment, and are used extensively in lab design for healthcare and research facilities. The same basis for these curves can be used to quantify acceptable limits of vibration for human comfort, depending on the intended occupancy of the space. When available, manufacturer's vibration criteria for sensitive equipment are expressed in units of acceleration, velocity or displacement and can be specified as zero-to-peak, peak-to-peak, or root-mean-square (rms) with varying frequency ranges and resolutions. Several approaches to prediction of floor vibrations are currently applied in practice. Each method is traceable to fundamental structural dynamics, differing only in the level of complexity assumed for the system response, and the required information for use as model inputs. Three commonly used models are described, as well as key features they possess that make them attractive to use for various applications. A case study is presented of a tall building which has fitness areas on two of the upper floors. The analysis predicted that the motions experienced would be within the given criteria, but showed that if the floor had been more flexible, the potential exists for a locked-in resonance response which could have been felt over large portions of the building.

Assessment of Smoke Risk of Combustible Materials in Fire (화재 시 가연성 물질의 연기 위험성 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.31 no.3
    • /
    • pp.277-283
    • /
    • 2020
  • The smoke hazard assessment of building materials focusing on smoke performance index-II (SPI-II) and smoke growth index-II (SGI-II) was investigated. The test species used were Japanese cedar, spruce, lauan, and red pine. The smoke characteristics of wood specimen were investigated using a cone calorimeter (ISO 5660-1). SPI-II was measured after the combustion reaction increased by 1.31~2.15 times based on red pine. The fire risk by SPI-II increased in the order of spruce, lauan, Japanese ceda, and red pine. SGI-II increased by 1.18~2.55 times compared to that of Japnese ceda. The fire risk caused by SGI-II increased in the order of Japanese ceda, spruce, lauan, and red pine. COmean concentrations were ranged from 58 to 133 ppm, which was higher than permissible exposure limits of the occupational safety and health administration (OSHA), 50 ppm. Therefore, woods such as red pine containing various volatile organic substances, were considered to be highly smoke hazardous due to low SPI-II and high SGI-II.

Optimization of analytical conditions for the determination of nitrosamines in chlorinated tap water by high performance liquid chromatography (액체크로마토그래피를 이용한 수돗물 중 nitrosamine 화합물 분석의 최적화)

  • Han, Ki-Chan;Kim, He-Kap
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.551-559
    • /
    • 2010
  • This study was conducted to establish an analytical method for the determination of seven nitrosamines in chlorinated tap water by precolumn derivatization followed by high performance liquid chromatography coupled with fluorescence detection. The derivatization procedure was optimized for denitrosation and dansylation, and then two extraction methods, liquid-liquid extraction (LLE) with dichloromethane and solid phase extraction (SPE), were compared. The SPE method employing the optimized derivation procedure showed higher extraction recovery (54.4-88.7%) and reproducibility (1.9-19.4%) than the LLE method (51.4-87.7% and 4.2-33.3%, respectively). The method detection limits were between 0.5 and 4.4 ng/L. When chlorinated water samples were collected from two treatment plants and ten household taps, and analyzed for nitrosamines, Nnitrosodimethylamine (NDMA) was the major compound found between 26.1 and 112 ng/L.

Simultaneous Determination of Vitamin A and E in Infant Formula by HPLC with Photodiode Array Detection

  • Lee, Hong-Min;Kwak, Byung-Man;Ahn, Jang-Hyuk;Jeong, Seung-Hwan;Shim, Sung-Lye;Kim, Kyong-Su;Yoon, Tae-Hyung;Leem, Dong-Gil;Jeong, Ja-Young
    • Food Science of Animal Resources
    • /
    • v.31 no.2
    • /
    • pp.191-199
    • /
    • 2011
  • The objective of this study was to develop a method to simultaneously quantify vitamins A and E in infant formula. To determine the vitamin A and E content, vitamin A and four different vitamin E isomers (${\alpha}$-, ${\beta}$-, ${\gamma}$-, and ${\delta}$-tocopherol) were separated by high performance liquid chromatography with a photodiode array detector using a Develosil RPAQUEOUS RP-$C_{30}$ column ($4.6{\times}250$ mm, 5 ${\mu}M$). The vitamin A and E contents in the certified reference material determined using this method were within the certified range of standard values. The limits of detection (LODs) and limits of quantitation (LOQs) for vitamin A were 0.02 and 0.06 ${\mu}g/L$, respectively. LODs and LOQs for the vitamin E isomers ranged from 0.20 to 0.55 and from 0.67 to 1.81 ${\mu}g/L$, respectively. Linear analyses indicated that the square of the correlation coefficient for the vitamin A and E isomers was 0.9997-0.9999. The recovery of vitamins ranged from 96.69 to 97.79%. The results demonstrate that this novel method could be used to reliably analyze vitamin A and E content in infant formula.

Unlimited Cooperative Sensing with Energy Detection for Cognitive Radio

  • Bae, Sunghwan;Kim, Hongseok
    • Journal of Communications and Networks
    • /
    • v.16 no.2
    • /
    • pp.172-182
    • /
    • 2014
  • In this paper, we investigate the fundamental performance limits of the cooperative sensing using energy detection by considering the unlimited number of sensing nodes. Although a lot of cognitive radio research so far proposed various uses of energy detection because of its simplicity, the performance limits of energy detection have not been studied when a large number of sensing nodes exist. First, we show that when the sensing nodes see the independent and identically distributed channel conditions, then as the number of sensing nodes N goes to infinity, the OR rule of hard decision achieves zero of false alarm Pf for any given target probability of detection $\bar{P_d}$ irrespective of the non-zero received primary user signal to noise ratio ${\gamma}$. Second, we show that under the same condition, when the AND rule of hard decision is used, there exists a lower bound of $P_f$. Interestingly, however, for given $\bar{P_d}$, $P_f$ goes to 1 as N goes to infinity. Third, we show that when the soft decision is used, there exists a way of achieving 100% utilization of secondary user, i.e., the sensing time overhead ratio goes to zero so does $P_f$.We verify our analyses by performing extensive simulations of the proposed unlimited cooperative sensing. Finally, we suggest a way of incorporating the unlimited cooperative sensing into a practical cellular system such as long term evolutionadvanced by exploiting the existing frame structure of absolute blank subframe to implement the in-band sensing.

Seismic behavior of full-scale square concrete filled steel tubular columns under high and varied axial compressions

  • Phan, Hao D.;Lin, Ker-Chun
    • Earthquakes and Structures
    • /
    • v.18 no.6
    • /
    • pp.677-689
    • /
    • 2020
  • A building structural system of moment resisting frame (MRF) with concrete filled steel tubular (CFST) columns and wide flange H beams, is one of the most conveniently constructed structural systems. However, there were few studies on evaluating seismic performance of full-scale CFST columns under high axial compression. In addition, some existing famous design codes propose various limits of width-to-thickness ratio (B/t) for steel tubes of the ductile CFST composite members. This study was intended to investigate the seismic behavior of CFST columns under high axial load compression. Four full-scale square CFST column specimens with a B/t of 42 were carried out that were subjected to horizontal cyclic-reversal loads combined with constantly light, medium and high axial loads and with a linearly varied axial load, respectively. Test results revealed that shear strength and deformation capacity of the columns significantly decreased when the axial compression exceeded 0.35 times the nominal compression strength of a CFST column, P0. It was obvious that the higher the axial compression, the lower both the shear strength and deformation capacities were, and the earlier and faster the shear strength degradation occurred. It was found as well that higher axial compressions resulted in larger initial lateral stiffness and faster degradation of post-yield lateral stiffness. Meanwhile, the lower axial compressions led to better energy dissipation capacities with larger cumulative energy. Moreover, the study implied that under axial compressions greater than 0.35P0, the CFST column specimens with B/t limits recommended by AISC 360 (2016), ACI 318 (2014), AIJ (2008) and EC4 (2004) codes do not provide ultimate interstory drift ratio of more than 3% radian, and only the limit in ACI 318 (2014) code satisfies this requirement when axial compression does not exceed 0.35P0.

Analysis of tetracyclines in shrimp samples based on a two-step extraction approach prior to high-performance liquid chromatography

  • Thinnakorn Sukkhunthod;Thanakorn Pluangklang;Sumita Boonnab;Sira Sansuk;Phitchan Sricharoen;Maliwan Subsadsana
    • Analytical Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.211-219
    • /
    • 2024
  • This study presents a sensitive and reliable method for determining tetracycline (TC), oxytetracycline (OTC), and chlortetracycline (CTC) residues in shrimp samples. A two-step process involving liquid-liquid extraction (LLE) followed by solid-phase extraction (SPE) was developed prior to HPLC analysis. The target analytes were effectively extracted using EDTA/McIlvaine buffer (pH 4.0): methanol (80:20, %v/v), with subsequent clean-up using a C18 SPE cartridge. HPLC separation was conducted on a C18 column (250 mm × 4.6 mm i.d., 5 ㎛) at 30 ℃, using 0.01 % trifluoroacetic acid (A) and acetonitrile (B) as the mobile phase. A gradient elution protocol was applied, transitioning from 85(A):15(B) %v/v to 70(A):30(B) %v/v at 7 min, with a 5 min hold, followed by adjustment to 85(A):15(B) %v/v for 13-14 min. The detection was performed using photodiode array (PDA) at 365 nm with a flow rate of 1.0 mL/min. The calibration curves exhibited good linearity within a concentration range of 0.4-6.0 ㎍/mL (R2 > 0.995). The limits of detection (LOD) for TC, OTC, and CTC in shrimp were 0.034, 0.029, and 0.021 ㎍/mL, respectively. The limits of quantitation (LOQ) for TC, OTC, and CTC were found to be 0.114, 0.097, and 0.071 ㎍/mL, respectively. Recoveries of TC, OTC, and CTC from spiked shrimp samples ranged from 91.0 % to 95.5 %, 92.4 % to 97.2 %, and 93.3 % to 96.6 %, respectively. This method was successfully applied to the determination of TC, OTC, and CTC residues in shrimp samples sourced from various local markets.

A Cost Effective Energy Saving of Fluorescent Lighting in Commercial Buildings

  • Lee, Seong-Ryong;Nayar, Chemmangot V.
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.215-222
    • /
    • 2012
  • Lighting represents a significant component of commercial buildings, particularly office buildings. Fluorescent lighting is invariably used in all commercial, industrial and residential areas. A significant amount of lighting energy is wasted every day by leaving the lights on and not utilizing daylight energy. However, if daylight illuminance can be harnessed, this will reduce the electricity consumption of fluorescent lamps and save energy. This paper explains possible significant savings in lighting energy consumption and hence in costs, without reducing the performance and visual satisfaction in office or industrial buildings. It is proposed to obtain energy saving by reducing the supply voltage without degradation in lighting performance. Experimental results confirm that as much as 20% of electrical energy can be saved by reducing about 9% of the supply voltage, without noticeably affecting light output while complying with lighting standard limits.

A File System for Large-scale NAND Flash Memory Based Storage System

  • Son, Sunghoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.9
    • /
    • pp.1-8
    • /
    • 2017
  • In this paper, we propose a file system for flash memory which remedies shortcomings of existing flash memory file systems. Besides supporting large block size, the proposed file system reduces time in initializing file system significantly by adopting logical address comprised of erase block number and bitmap for pages in the block to find a page. The file system is suitable for embedded systems with limited main memory since it has small in-memory data structures. It also provides efficient management of obsolete blocks and free blocks, which contribute to the reduction of file update time. Finally the proposed file system can easily configure the maximum file size and file system size limits, which results in portability to emerging larger flash memories. By conducting performance evaluation studies, we show that the proposed file system can contribute to the performance improvement of embedded systems.