• Title/Summary/Keyword: Performance feedback

Search Result 2,557, Processing Time 0.033 seconds

Effects of Feedback Types on Users' Subjective Responses in a Voice User Interface (음성 사용자 인터페이스 내 피드백 유형이 사용자의 주관적 반응에 미치는)

  • Lee, Dasom;Lee, Sangwon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.219-222
    • /
    • 2017
  • This study aimed to demonstrate the effect of feedback type on users' subjective responses in a voice user interface. Feedback type is classified depend on information characteristic it involves; verification feedback and elaboration feedback. Error type is categorized as recognition error and performance error. Users' subjective assessment about system, feedback acceptance, and intention to use were measured as dependent variables. The results of experiment showed that feedback type has impacts on the subjective assessment(likeability, habitability, system response accuracy) of VUI, feedback acceptance, and intention to use. the results also demonstrated an interaction effect of feedback type and error type on the feedback acceptance. It leads to the conclusion that VUI should be designed with the elaboration feedback about error situation.

  • PDF

Superheat Control of an Inverter-driven Heat Pump Using PI Control Algorithm

  • Park, Jong-Min;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.2
    • /
    • pp.106-115
    • /
    • 2002
  • The performance of an inverter-driven water-to-water heat pump with an electronic expansion valve (EEV) was measured as a function of compressor frequency, load conditions, and EEV opening. Based on the test results, a controller using proportional integral (PI) feedback or PI feedforward algorithm was designed and tested to investigate capacity modulation and transient response control of the system. Although the relation between superheat and EEV opening of the heat pump showed nonlinear characteristics, a control gain obtained at the rated frequency was applicable to various operating conditions without causing large deviations. When the simple PI feedback control algorithm was applied, a large overshoot of superheat and wet compression were observed due to time delay effects of compressor frequency. However, applying PI feedforward control scheme yielded better system performance and higher reliability, compared to the PI feedback algorithm.

Control Strategy of Ratio Changing System for a Metal V-Belt CVT Adopting Primary Pressure Regulation (압력제어 방식 금속 벨트 CVT 변속비 제어 전략)

  • 최득환;김현수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.201-208
    • /
    • 2002
  • In this paper, the control strategy of ratio changing system for a metal belt CVT adopting primary pressure regulation is developed, and the shirting performance of pressure regulating type CVT with the suggested control strategy is investigated. The control strategy suggested in this study is composed of 2 feedback loop, one is speed ratio feedback and the other is primary pressure feedback. The pressure feedback is adopted to ensure prohibiting a belt slip during transient period in a fast downshift mode. Simulation results show that the system with suggested control strategy gives appropriate response time and tracking Performance for upshift and also gives a proper primary pressure which can prohibit the belt slip. In addition, it is fecund that the given system has an acceptable servo property in tracking the target speed ratio and robustness for the disturbance of line pressure.

Feedback Loop Design for Micro Gyroscope

  • Sung, Woon-Tahk;Song, Jin-Woo;Lee, Jang-Gyu;Taesam Kang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.39.4-39
    • /
    • 2002
  • This paper presents a design and implementation of a PID feedback control loop for micro gyroscope. The feedback control loop improves the gyroscope performance such as linearity, bandwidth, and bias stability for micro gyroscope which is basically a high-Q system and exhibits a low performance with an open loop control. The designed and implemented feed-back control loop is applied to the SNU-Bosch MEMS gyroscope to demonstrate the improvement with the feedback control loop. The bandwidth is improved to 60Hz from 25Hz of open loop control. The linearity becomes 0.5% from 1%. The bias stability is improved to 0.03 deg/sec from 0.06 deg/sec.

  • PDF

Performance Analysis of Suboptimal Receiver Combining Adaptive Array Antenna and Orthogonal Decision-Feedback Detector for DS/CDMA System

  • Cho, Young-pil;Yoo, Sung-Kyun;Lee, Hyung-ki;Kwak, Kyung-sup
    • Proceedings of the IEEK Conference
    • /
    • 2002.07b
    • /
    • pp.1354-1357
    • /
    • 2002
  • In this paper, we propose a suboptimal receiver combining adaptive array antenna and orthogonal decision-feedback detector in DS/CDMA system. Adaptive array antenna can cancel out undesired signal using beamforming scheme. However, if there are interfering signals from undesired users with the same incident angle as that of a desired user, an adaptive array antenna cannot suppress them. The proposed receiver can cancel out remaining interference from users having nearly the same beam pattern. And we employ Orthogonal Decision-Feedback Detector (ODFD) as multiuser detection. The ODFD performs as good as the decorrelating decision -feedback detector (DDD) with much less complexity. Simulation results show that the proposed system provides a significantly enhanced performance.

  • PDF

An LMI-Based Fuzzy State Feedback Control with Multi-objectives

  • Hong, Sung-Kyung;Yoonsu Nam
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.105-113
    • /
    • 2003
  • This paper proposes a systematic design methodology for the Takagi-Sugeno (TS) model based fuzzy state feedback control system with multi-objectives. In this investigation, the objectives are set to be guaranteed stability and pre-specified transient performance, and this scheme is applied to a nonlinear magnetic bearing system. More significantly, in the proposed methodology, the control design problems that consider both stability and desired transient performance are reduced to the standard LMI problems. Therefore, solving these LMI constraints directly (not trial and error) lead to a fuzzy state-feedback controller such that the resulting fuzzy control system meets the above two objectives. Simulation and experimentation results show that the Proposed LMI-based design methodology yields not only maximized stability boundary but also the desired transient responses.

Design of MTLMS Based Decision Feedback Equalizer

  • Choi Yun-Seok;Park Hyung-Kun
    • Journal of information and communication convergence engineering
    • /
    • v.4 no.2
    • /
    • pp.58-61
    • /
    • 2006
  • A key issue toward mobile multimedia communications is to create technologies for broadband signal transmission that can support high quality services. Such a broadband mobile communications system should be able to overcome severe distortion caused by timevarying multi-path fading channel, while providing high spectral efficiency and low power consumption. For these reasons, an adaptive suboptimum decision feedback equalizer (DFE) for the single-carrier shortburst transmissions system is considered as one of the feasible solutions. For the performance improvement of the system with the short-burst format including the short training sequence, in this paper, the multiple-training least mean square (MTLMS) based DFE scheme with soft decision feedback is proposed and its performance is investigated in mobile wireless channels throughout computer simulation.

Design of a Auto-Tuning Digital PID Controller using Relay feedback and Time Delay (시간 지연 릴레이 피드백을 이용한 자동동조 디지털 PID 제어기의 설계)

  • 류경모;박정일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.109-109
    • /
    • 2000
  • In process industries, more than 90% of the control loops have PID controller. Futhermore, the most control systems are using classical PID controllers for their process control. Various auto-tuning methods of PID gains using relay-feedback are presented recently. In order to get the desired control performance, the correct tuning of PID controller is very important. This paper suggests how to tune of digital PID gains using information for both the Nyquist critical point by conventional method and another point by the relay feedback and hidden time-delay term. Simulation results show that the proposed controller has better performance than the conventional method.

  • PDF

A Study on the Design of the Optimal Nonlinear Controller for Single State Feedback (단일상태 귀환 제어계의 최적 비선형제어기 설계에 관한 연구)

  • No, Yong-Gyun;Jo, Gyeom-Rae;Lee, Jin-Geol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.6 no.1
    • /
    • pp.85-92
    • /
    • 1989
  • For feedback control of a linear dynamic system the optimum linear state regulator (OLSR) can be implemented only if all states are available for feedback. This work demonstrates that when only the output state is available for feedback, a nonlinear controllers can give improved performance over that obtained by a proportional controller. This paper found the optimal control law by dynamic programming and principles of optimalityl. This, performances of both proportional and nonlinear controllers are compared with performance of optimum linear state regulator.

  • PDF

A Design of a High Performance UPS with Capacitor Current Feedback for Nonlinear Loads (비선형 부하에서 커패시터 전류 궤환을 통한 고성능 UPS 설계)

  • Lee, Woo-Cheol;Lee, Taeck-Kie
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.5
    • /
    • pp.71-78
    • /
    • 2012
  • This paper presents a digital control solution to process capacitor current feedback of high performance single-phase UPS for non-linear loads. In all UPS the goal is to maintain the desired output voltage waveform and RMS value over all unknown load conditions and transient response. The proposed UPS uses instantaneous load voltage and filter capacitor current feedback, which is based on the double regulation loop such as the outer voltage control loop and inner current control loop. The proposed DSP-based digital-controlled PWM inverter system has fast dynamic response and low total harmonic distortion (THD) for nonlinear load. The control system was implemented on a 32bit Floating-point DSP controller TMS320C32 and tested on a 5[KVA] IGBT based inverter switching at 11[Khz]. The validity of the proposed scheme is investigated through simulation and experimental results.