• Title/Summary/Keyword: Performance Type

Search Result 13,103, Processing Time 0.044 seconds

Experimental study on the characteristics of heat transfer for new type aluminum tube (신형 알루미늄관의 열전달 특성에 관한 실험적 연구)

  • 문춘근;윤정인;김재돌
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.2
    • /
    • pp.31-37
    • /
    • 2000
  • This study investigated heat transfer characteristics of refrigeration system using new type aluminium heat transfer tube for evaporator of refrigeration and air-conditioning comparing with bare tube. From the result of heat transfer experiment form one phase flow using cooled and hot water, about 20% heat transfer performance is superior in case of same quantity of flow and about 4% heat transfer performance if superior in case of same velocity comparing with bare tube. Casing of two phase flow, heat transfer performance of new type aluminum heat transfer tube shows about 50% superior heat transfer performance comparing with bare tube in the same evaporating pressure when using heat transfer tube as evaporator and shows about 47% increase when expressing performance coefficient as the rate of refrigerating capacity and compressing work. However, it can be known that pressure drop in the heat transfer tube is taken higher value of about 18% in case of new type aluminum heat transfer tube. From the above result, new type aluminum heat transfer tube is excellent comparing with bare heat transfer tube using the existing heat exchanger for refrigerator.

  • PDF

Analysis of the Condenser Stack Effect in a High-Rise Apartment Building (고층 아파트에서 응축기 적층문제 분석)

  • 최석호;이관수;김인규;이동혁
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.796-803
    • /
    • 2004
  • The stack effect of a new type condenser installed in a high-rise apartment building was studied numerically A sirocco fan is introduced to the new type condenser instead of an axial flow In. The new type condenser intakes the cold air through the lower inlet and exhausts the hot air through the upper outlet. The effects of the building height and frontal wind on the performance of an air-conditioner were analyzed. The performance of an air-conditioner was evaluated by using COP (coefficient of performance) and CGPI (condenser group performance indicator). the hot air was exhausted by the new type condenser at an angle of 50$^{\circ}$ from the outer wall of the building. If there was no draft, the new type condenser installed in the high-rise apartment building had a good performance and its performance on each floor is not influenced by the stack effect. It is shown that the efficiency of the air-conditioner installed in several floors below the top floor decreased when the frontal wind velocity was greater than 8 m/s.

Performance of Steel Fiber Reinforced Shotcrete using Alkali Free Based Accelerator (알칼리 프리계 급결제를 사용한 강섬유 보강 숏크리트의 성능 평가)

  • Baek, Chul-Woo;Park, Chan-Gi;Jun, Oun-Jung;Won, Jong-Pil
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.3
    • /
    • pp.65-72
    • /
    • 2004
  • Modern underground and tunnel works that the wet type shotcrete is getting widely designed and applied in a large scale project. Further to its applications, the needs of improving the performance of the shotcrete, such as new and developed additives and accelerators fur increasing the performance of shotcrete, become the most important issue in the field. The main objective of this study evaluated to performance of steel fiber reinforced shotcrete using alkali free based accelerator for the durability and high quality of shotcrete. The major test variables are accelerator type and its dosage. One type silicate based accelerator and one type aluminate based accelerator and one type alkali free based accelerator were used. The dosage of accelerators is determined by the manufactures and laboratory test condition. Compressive strength test results showed that the dosage of silicate and aluminate based accelerators caused reduction of mechanical properties of shotcrete. Compressive strength of alkali free based accelerator is more stable than of silicate and aluminate based accelerators. Also, according to the compressive strength and flexural test results, it was found that steel fiber reinforced shotcrete used alkali free based accelerator could attain significant improvement in the mechanical and flexural performance.

Evaluation on in-situ Thermal Performance of Coaxial-type Ground Heat Exchanger with Different Configurations (이중관형 지중열교환기 구성에 따른 현장 열성능 평가)

  • Lee, Seokjae;Jung, Hyun-seok;Oh, Kwanggeun;Park, Sangwoo;Choi, Hangseok
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.4
    • /
    • pp.8-15
    • /
    • 2019
  • In order to design coaxial-type Ground Heat Exchangers (GHEXs) efficiently, the effect of components (i.e, heat exchange pipe and grouting material) on the thermal performance of coaxial-type GHEXs should be identified in advance. In this paper, three coaxial-type GHEXs with different configurations were constructed in a test bed. Then, the effect of heat exchange pipes and grouting materials on the thermal performance of coaxial-type GHEXs was investigated by performing in-situ thermal response tests (TRTs) and thermal performance tests (TPTs). In the TRTs, the effective thermal conductivities of the coaxial-type GHEXs with concrete grouting and STS pipes were improved by 6.15 and 22.7%, respectively compared to those of bentonite grouting and HDPE pipes. Additionally, in the TPTs, the use of concrete grouting and STS pipes in the coaxial-type GHEXs enhanced the in-situ thermal performance by 15 and 33.8%, respectively.

Effects of Factors of Purchase Intention to Viewing Performance by Audience Type (관객유형에 따른 공연관람 구매의사 요인에 미치는 영향)

  • Kwon, Hyeog-In;Jung, Soon-Gyu;Choi, Yong-Seok
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.2
    • /
    • pp.139-150
    • /
    • 2015
  • This study highlighted influences which affect purchase intention of audience to viewing performance. And after grouping audience types by applying the cluster analysis to samples which are collected by survey, this study examined how purchase intentions influence audience to viewing performance by each audience type. Thus, to improve the reliability to classify audience type, the sample was selected by considering neither age group nor previous experience of viewing performance arts. Factor analysis and reliability analysis was performed to analyze the effect of purchase intention according to the type of audience. And we used AMOS program to verify using SEM(Structural Equation Modeling) how affect it was with moderating variable of audience type. Through surveying and analyzing th results, we confirmed that viewing motivation and quality of performing work have significant effect on purchase intention and significant moderating effect according to audience type. Therefore, we contribute to make suitable strategy that they figure out audience type, when performing art organizations make marketing strategy.

The performance and flow characteristics of a small propeller fan with a back-plate (뒷판이 있는 소형 프로펠러 팬의 성능 및 유동특성)

  • Gang, Sin-Hyeong;Kim, Jin-Gwon;Lee, Seung-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.4
    • /
    • pp.1491-1500
    • /
    • 1996
  • Unstable performance deterioration was found on the performance curve of a small propeller fan with a back plate. To investigate this phenomenon and the effects of the back-plate on the performance of the fan, performance tests and flow measurement using 3-hole pitot tube were carried out. Measurements showed that when the flow rate is small, the radial flow dominates, and when the flow rate is large, the axial flow dominates. Performance characteristic of the propeller fan changes from radial to axial type as the flow rate increases. Unstable performance changes are the result of type change of the flow through the fan.

A Study on the Performance Characteristics of Fin-type Heat Exchanger for the Automobile Air-Conditioners (자동차 공조용 핀형 열교환기의 성능특성에 관한 연구)

  • 홍경한;전상신;이승재;박찬수;권일욱;김재열;김병철;하옥남
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.4
    • /
    • pp.100-105
    • /
    • 2004
  • Fin-tube type(Fin-type) heat exchanger has been tested in order to replace the heat exchanger of parallel flow type(P.F -type) which is now widly used in automobile air conditioning system The following conclusions are drawn by the comparison of the characteristics of the heat exchangers. Evaporator and condenser capacities and COP(Coefficience of performance) were varied as with the compressor speed, outdoor air temperature and air flow rate changed, which much influenced on the characteristics of the air conditioning system Evaporator and condenser capacities were increased with increasing compressor speed and outdoor air temperature. Evaporator and condenser pressures of Fin-type were decreased by 7% and 5% respectively compared with those of P.F-type. The COP of Fin-type was decreased with increasing outdoor air temperature and compressor speed. The COP of P.F-type was decreased by 14% compared with that of Fin-type.

Preschoolers' peer interaction type and joint problem-solving performance depending on a partner's age (또래쌍구성에 따른 유아의 상호작용과 문제해결력)

  • Kwon, Hye-Jin
    • Korean Journal of Human Ecology
    • /
    • v.15 no.1
    • /
    • pp.1-15
    • /
    • 2006
  • The purpose of this study is (1) to investigate how children's peer interaction type and joint problem-solving performance differ, depending on a partner's age, in such a situation as they are asked to solve problems with their peer and (2) to investigate relationship between children's peer interaction type and joint problem-solving performance. Results reveal that children's problem-solving performance receives more benefit in the interactions with older peers, rather than those with younger ones. It can also be improved by higher level of collaborative interactions such as abstract collaborative explanations in joint activities. It is influenced positively by collaborative interactions, expecially when the children are in the same age groups. Results here were discussed in terns Piagetian and Vygotskian theories.

  • PDF

A HYPOTHESIS TESTING PROCEDURE OF ASSESSMENT FOR THE LIFETIME PERFORMANCE INDEX UNDER A GENERAL CLASS OF INVERSE EXPONENTIATED DISTRIBUTIONS WITH PROGRESSIVE TYPE I INTERVAL CENSORING

  • KAYAL, TANMAY;TRIPATHI, YOGESH MANI;WU, SHU-FEI
    • Journal of applied mathematics & informatics
    • /
    • v.37 no.1_2
    • /
    • pp.105-121
    • /
    • 2019
  • One of the main objective of manufacturing industries is to assess the capability performance of different processes. In this paper, we use the lifetime performance index $C_L$ as a criterion to measure larger-the-better type quality characteristic for evaluating the product performance. The lifetimes of products are assumed to follow a general class of inverted exponentiated distributions. We use maximum likelihood estimator to estimate the lifetime performance index under the assumption that data are progressive type I interval censored. We also obtain asymptotic distribution of this estimator. Based on this estimator, a new hypothesis testing procedure is developed with respect to a given lower specification limit. Finally, two numerical examples are discussed in support of the proposed testing procedure.

A Comparison of Nighttime Sleepiness, Performance, and Body Temperature between Morning-Type and Evening-Type Persons (아침형과 저녁형 사람에서 야간의 졸리움, 수행 및 체온의 비교)

  • Yoon, Jin-Sang;Kook, Seung-Hee;Shin, Il-Seon;Shin, Man-Sik;Choi, Young;Lee, Mu-Suk;Lee, Hyung-Young
    • Sleep Medicine and Psychophysiology
    • /
    • v.1 no.1
    • /
    • pp.47-59
    • /
    • 1994
  • Objectives: The main purpose of this study was to investigate the possible differences in sleepiness, performance, and body temperature during the night between morning(M) and evening(E) type subjects. Methods: After a survey study, to verify the validity and reliability of the Korean translation of the Home' and $\ddot{O}stberg's$ Morningness-Eveningness Questionnaire(1976), 8 extreme M-type subjects(3males, 5 females) and 8 extreme E-type subjects(3 males, 5 females) were selected from the university student population who had participated in the survey study. All subjects underwent sleep latency test and a battery of performance tests at intervals of 2 hours through the night, from 23:00 to 07:00. Oral temperature of each subject was taken every hour from 21 : 00 to 8 : 00. Between the testing times, the experimenters ensured that subjects remained awake. Results: More profound sleepiness was found in the M-type compared to the E-type throughout the night, with significant differences in sleepiness occuring at 23:00 and 01:00 hours. Overall performance efficiency tended to be lower through, the night in the M-type than in the E-type on all tests. A difference in time of temperature minimum between the two types was not noteworthy. Rather, there appeared to be a substantial difference in temperature level during the declining phase, with the temperature of the M-type being lower than that of the E-type. Conclusions: These results indicate the existance of a temporal relationship between sleepiness, perfonnance and body temperature during night work. Since the M-type exhibited greater sleepiness and lower performance efficiency overnight than the E-type, it may be assumed that the E-type is more suitable for and tolerable to night work. There was some discussion of the limitations in generalizing these results together with some suggestions for future studies.

  • PDF