• 제목/요약/키워드: Performance Standard

검색결과 6,942건 처리시간 0.035초

캐나다 시멘트 및 콘크리트의 내구성 및 제성능에 대한 규준 (Durability and Performance Requirements in Canadian Cement and Concrete Standards)

  • Hooton, R.D.
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.5-21
    • /
    • 2006
  • Traditional standards and specifications for concrete have largely been prescriptive, (or prescription-based), and can sometimes hinder innovation and in particular the use of more environmentally friendly concretes by requiring minimum cement contents and SCM replacement levels. In December 2004, the Canadian CSA A23.1-04 standard was issued which made provisions (a) for high-volume SCM concretes, (b) added new performance requirements for concrete, and (c) clearly outlined the requirements and responsibilities for use in performance-based concrete specifications. Also, in December 2003, the CSA A3000 Hydraulic Cement standard was revised. It (a) reclassified the types of cements based on performance requirements, with both Portland and blended cements meeting the same physical requirements, (b) allows the use of performance testing for assessing sulphate resistance of cementitious materials combinations, (c) includes an Annex D, which allows performance testing of new or non-traditional supplementary cementing materials. From a review of international concrete standards, it was found that one of the main concerns with performance specifications has been the lack of tests, or lack of confidence in existing tests, for judging all relevant performance concerns. Of currently used or available test methods for both fresh, hardened physical, and durability properties, it was found that although there may be no ideal testing solutions, there are a number of practical and useful tests available. Some of these were adopted in CSA A23.1-04, and it is likely that new performance tests will be added in future revisions. Other concerns with performance standards are the different perspectives on the point of testing for performance. Some concrete suppliers may prefer processes for both pre-qualifying the plant, and specific mixtures, followed only with testing only 'end-of-chute' fresh properties on-site. However, owners want to know the in-place performance of the concrete, especially with high-volume SCM concretes where placing and curing are important. Also, the contractor must be aware of, and share the responsibility for handling, constructability, curing, and scheduling issues that influence the in-place concrete properties.

  • PDF

A Study on Performance Assessment Methods Using Fuzzy Logic

  • Chae, Gyoo-Yong;Jang, Gil-Sang;Joo, Jae-Hun
    • 한국산업정보학회논문지
    • /
    • 제9권1호
    • /
    • pp.92-102
    • /
    • 2004
  • 자기 주도적 학습능력의 수준별 교육을 위한 평가 방법으로서, 수행평가는 문제해결 능력과 높은 사고 능력평가에 대한 한계점을 극복하고 수업의 질과 학교 정상화를 위한 계획으로 선호되고 있다. 그러나 수행평가는 평가 오류, 채점 공정성 문제, 신뢰도 및 객관성 등의 확보에 어려움 있다. 이런 문제점을 해결하고 수행평가 만족을 높이기 위하여, 본 논문에서는 회계원리 과목을 대상으로 수행평가에 대한 각 영역에서 영향을 주는 인자를 분석하여 퍼지 소속 함수를 설계하고, 이를 적용한 객관적이고 신뢰성 높은 수행평가 방법을 제시하고자 한다.

  • PDF

예비타당성조사 결과를 활용한 도로건설사업의 계획단계 성과 분석 연구 (Analyzing Planning Performance of Road Construction Projects Using Preliminary Feasibility Analysis Data)

  • 문준부;윤성민
    • 한국건설관리학회논문집
    • /
    • 제24권1호
    • /
    • pp.3-11
    • /
    • 2023
  • 현재 국내에서는 건설공사 사후평가 제도에 따라 사업 준공 후 공사내용 및 그 효과를 조사하여 프로젝트의 성과를 평가하고 향후 계획된 유사 건설사업의 효율적인 수행을 위한 자료로 활용하고 있다. 그러나 건설사업의 성과를 보다 효과적으로 관리하기 위해서는 프로젝트 진행 과정에서 단계별 성과를 평가하여 그에 따른 유연한 관리전략을 수립할 수 있어야 한다. 따라서 건설사업의 효율적인 성과관리를 위해서는 건설사업 단계별 성과평가체계가 필요하다. 본 연구는 건설사업 초기단계의 성과를 평가할 수 있는 계획단계 벤치마킹을 위한 기초 모델을 제시하고자 한다. 이를 위하여 본 연구에서는 한국개발연구원에서 제공하고 있는 예비타당성 조사 보고서 중 완료된 도로공사 354건에 대해 데이터베이스를 구축하였다. 계획단계 성과를 평가할 성과지표로 시설용량을 기준으로 한 표준공사비와 표준공사기간 지표를 개발하여 도로사업의 계획단계의 성과를 분석할 수 있는 벤치마킹 모델을 제시하였다. 이를 통해 도로사업 계획단계의 표준공사비 및 표준공사기간을 산정하고, 도로사업의 특성별 차이를 분석하였다. 본 연구의 결과를 활용하여 계획단계의 성과와 설계 및 시공단계의 성과를 연계하여 분석한다면 건설사업 생애주기 동안의 성과관리가 가능할 것으로 기대된다.

차세대 이동통신 시스템을 위한 PAPR 감소와 대역 내 왜곡보정 기법에 대한 연구 (A Study on the PAPR Reduction and In-Band Distortion Compensation Schemes for Next Generation Mobile Communication Systems)

  • 노재성;김완태
    • 한국항행학회논문지
    • /
    • 제16권2호
    • /
    • pp.234-239
    • /
    • 2012
  • 차세대 이동통신 시스템은 다양한 서비스를 지원하기 위해 다양한 분야에서 연구되며 응용되고 있다. 차세대 이동통신 시스템 연구에 있어 최대 관심은 다양한 통신시스템의 통합과 빠른 데이터 전송을 이용한 다양한 서비스의 제공이다. 통신시스템의 통합은 Multi Standard Modem을 이용하여 연구되고 있으며, 다양한 서비스 제공을 위한 빠른 데이터 전송은 OFDM(Othogonal Frequency Division Multiplexing) 방식이 적용되고 있다. 본 논문에서는 차세대 이동통신을 위한 Multi Standard Modem을 이용하여 PAPR(Peak-to-Average Power Ratio)을 감소시키기 위한 방법을 제안하고, PAPR 감소 중 발생되는 문제점인 대역 내 왜곡을 EVM(Error Vector Magnitude)을 이용하여 보정하는 기법을 제안하였다. 본 논문에서는 제안한 방법을 이용하여 차세대 이동통신 시스템의 PAPR 감소 효율, CCDF(Complementary Cumulative Distribution Function)와 BER(Bit Error Rate) 성능을 시뮬레이션을 통해 분석했다. 시뮬레이션 결과 차세대 이동통신 시스템의 성능이 개선됨을 알 수 있다.

프로세서 구조에 따른 DCT 알고리즘의 구현 성능 비교 (Performance Comparison of DCT Algorithm Implementations Based on Hardware Architecture)

  • 이재성;박영철;윤대희
    • 한국통신학회논문지
    • /
    • 제31권6C호
    • /
    • pp.637-644
    • /
    • 2006
  • 본 논문에서는 MPEG 오디오 부호화 과정 중 서브밴드 필터뱅크를 구현하기 위해 사용되는 DCT(Discrete Cosine Transform) 과정에 대해 구현 시스템의 구조에 따른 DCT 알고리즘의 구현 결과와 성능 차이를 분석한다. 고속 DCT 알고리즘은 코사인 계수의 내적을 통해 구하는 직접 구현 방법보다 연산량이 현저하게 적은 것으로 알려져 있지만, 피연산자의 어드레스가 불규칙적이고 출력 데이터를 재정렬하는 과정이 필요하기 때문에 규칙성이 결여되며, 재정렬만을 위한 추가적인 연산이 필요한 경우도 있다. 따라서 DSP와 같이 반복적인 연산을 고속으로 수행하기 위해 최적화된 구조의 하드웨어에서는 알고리즘의 규칙성이 높은 직접 구현 방법에 비해 고속 알고리즘이 불리한 측면이 있으며, 더욱이 유효 자리수를 제한하는 경우, 직접 구현 방법에 비해 더 많은 프로세싱 단계를 거쳐야 하므로 누적 오차가 커진다. 본 논문에서는 알고리즘의 규칙성과 각 프로세서의 연산 방법간의 관계와 유효 자리수에 따른 누적 오차를 분석하고 프로세서의 구조에 따른 고속 알고리즘의 선택 기준을 제시하였다.

조선대학교 사이클로트론 시설의 RI 배기필터 성능평가 및 18F 배출저감 연구 (Performance of the RI Exhaust Filter at Chosun University Cyclotron Facility and 18F Emission Reduction)

  • 정철기;장한;이경진
    • 방사선산업학회지
    • /
    • 제11권1호
    • /
    • pp.13-18
    • /
    • 2017
  • Recently, the number of PET cyclotrons has increased in Korea. A cyclotron mainly produces $^{18}F$, which is used for the production of [$^{18}F$]FDG, a cancer diagnostic radiopharmaceutical. For radiation protection, the discharge control standard under the Nuclear Safety Act limits the radioactive concentration of $^{18}F$ in the exhaust discharged from a nuclear power utilization facility to below $2,000Bq\;m^{-3}$. However, the radioactive concentration of $^{18}F$ discharged during [$^{18}F$]FDG production at the cyclotron facility at Chosun University is maintained at about $1,500Bq\;m^{-3}$ on average, which is 75% of the concentration limit of the discharge control standard, and temporarily exceeds the standard as per the real-time monitoring results. This study evaluated the performance of the exhaust filter unit of the cyclotron facility at Chosun University by assessing the concentration of $^{18}F$ in the exhaust, and an experiment was conducted on the discharge reduction, where $^{18}F$ is discharged without reacting with the FDG precursors during [$^{18}F$]FDG synthesis and is immediately captured by the [$^{18}F$]FDG automatic synthesis unit. Based on the performance evaluation results of the exhaust filter at the cyclotron facility of Chosun University, the measured capture efficiency before and after the filter was found to be 92%. Furthermore, the results of the discharge reduction experiment, where the exhaust $^{18}F$ was immediately captured by the [$^{18}F$]FDG synthesizer, showed a very satisfactory 94.3% reduction in the concentration of discharge compared to the existing discharge concentration.

135°표준갈고리 작업성 향상을 위한 철근보강클립 (RCC장치) 개발과정 및 현장적용 성과분석 (Development Process and Field Application Performance Analysis for Rebar Reinforcing Clips (RCC Device) to Improve Workability of 135 Degree Standard Hook)

  • 김용주;김은영;송화준;박경언
    • 한국건설관리학회논문집
    • /
    • 제22권6호
    • /
    • pp.138-146
    • /
    • 2021
  • 철근콘크리트 구조물내 교차된 양단 135° 표준갈고리 작업성을 향상시키기기 위하여 한쪽 90° 갈고리에 결속 보강함으로서 135° 표준갈고리와 대등한 성능을 발휘하는 원터치 방식의 철근보강클립(RCC장치)을 제안하였으며, 다양한 성능실험과 해석, 시공성 평가 및 경제성 분석을 통하여 개발 완료하였다. 2020년 6월부터 적용된 총 13개 현장을 분석한 결과, 개발할 당시의 예상한 것과 같이 구조감리나 공사감독관의 지적에 대해 불가항력적인 조치사항으로 적용하는 사례가 대부분이었다. 그러므로 현장성과분석을 통하여 효율적이고 자발적인 철근보강클립의 사용을 위해 원도급자가 우선 구매 후 협력엽체와 계약한 다음 제공하는 방식 등의 여러방식을 제안하였다. 결과적으로 철근보강클립을 적극적인 활용함으로써 현장에서 품질과 공정관리 측면에서 기여도가 매우 클 것으로 예상된다.

국내 원전 엔지니어링운영모델 활용성 향상을 위한 시스템 개발 (Development of Electronic Management System for improving the utilization of Engineering Model in Domestic Nuclear Power Plant)

  • 이상대;김정운;김문수
    • 한국안전학회지
    • /
    • 제36권5호
    • /
    • pp.79-85
    • /
    • 2021
  • A standard engineering model that reflects the current organization system and engineering operation process of domestic nuclear power plants was developed based on the Standard Nuclear Performance Model developed by the American Nuclear Energy Association. The level 0 screen, which is the main screen of the engineering model computer system, consisted of an object tree structure, which provided information that is phased down from a higher structure level to a lower structure level (i.e., level 3). The level 1 screen provided information related to the sub-process of the engineering operation, whereas the Level 2 screen provided information related to each engineering operation activity. In addition, the Level 2 screen provided additional functions, such as linking electronic procedures/guidelines, providing electronic performance forms, and connecting legacy computer systems (such as total equipment reliability monitoring system, configuration management systems, technical information systems, risk monitoring systems, regulatory information, and electronic drawing system). This screen level increased the convenience of user's engineering tasks by implementing them. The computerization of an engineering model that connects the entire engineering tasks of an establishment enables the easy understanding of information related to the engineering process before and after the operation, and builds a foundation for the enhancement of the work efficiency and employee capacity. In addition, KHNP developed an online training module, which operates as an e-learning process, on the overview and utilization of a standard engineering model to expand the understanding of standard engineering models by plant employees and to secure competitiveness.

다회용 마스크 유형에 따른 성능 비교연구 (A Comparison of Performance Evaluations of Reusable Masks)

  • 류회진;박원희;이춘영;정선옥;최희진;이정미;황인숙;신용승
    • 한국산업보건학회지
    • /
    • 제32권1호
    • /
    • pp.53-63
    • /
    • 2022
  • Objectives: This study was designed to evaluate the filtration efficiency, inhalation resistance, and liquid resistance of commercial reusable masks in comparison to the performance of KF-AD masks (reference masks). Methods: Thirty-six masks were purchased from an online market. Filtration efficiency and inhalation resistance were determined in the same manner as in MFDS certification testing, respectively using TIL/IL & Filter Test 1300S (SFP Services, UK) and Breathing Resistance Analyzer DA2001 (Lambda Ray, South Korea). Results: Most of the filtration efficiencies found for the 19 masks were far lower than the test standard for KF-certified masks. Four masks met KF94 and three masks even met KF80. Most inhalation resistances were also much lower than the standard, with many almost one-half of the standard. In addition, all the masks except KF-AD masks did not pass the liquid resistance test. Conclusions: Although most of the filtration efficiency performance results found in this study for the reusable masks, which emerged as an alternative, were lower than the standard for health masks, multi-use masks can be used with a replacement filter inserted.

Comparison of the Operational Speed of Hard-wired and IEC 61850 Standard-based Implementations of a Reverse Blocking Protection Scheme

  • Mnguni, Mkhululi Elvis Siyanda;Tzoneva, Raynitchka
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.740-754
    • /
    • 2015
  • This paper focuses on the reverse blocking busbar protection scheme with aim to improve the speed of its operation and at the same time to increase operational reliability, flexibility and stability of the protection during external and internal faults by implementation of the extended functionality provided by the IEC61850 standard-based protective Intelligent Electronic Devices (IEDs). The practical implementation of the scheme by the use of IEC 61850 standard communication protocol is investigated. The proposed scheme is designed for a radial type of a distribution network and is modeled and simulated in the DigSILENT software environment for various faults on the busbar and its outgoing feeders. A laboratory test bench is built using three ABB IEDs 670 series that are compliant with the IEC 61850 standard, CMC 356 Omicron test injection device, PC, MOXA switch, and a DC power supplier. Two types of the reverse blocking signals between the IEDs in the test bench are considered: hard wired and Ethernet communication by using IEC 61850 standard GOOSE messages. Comparative experimental study of the operational trip response speeds of the two implementations for various traffic conditions of the communication network shows that the performance of the protection scheme for the case of Ethernet IEC 61850 standard-based communication is better.