• 제목/요약/키워드: Performance Standard

검색결과 6,942건 처리시간 0.033초

건물 냉난방수배관의 단열성능 향상을 위한 기준 연구 (A Standard Study for Improving Thermal Performance of the Hot and Cold Water Pipe Insulation in Buildings)

  • 최승혁;김유승;윤희원;류형규
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권4호
    • /
    • pp.21-30
    • /
    • 2017
  • Recently, It has increased the importance of building energy saving. Pipe insulation as well as building envelope insulation is to improve energy efficiency and reduce the energy loss. However, there continues to use the old standard for pipe insulation that is one of the most important elements in energy savings in buildings. The purpose of this study is to propose suitable pipe insulation thickness for reducing building energy use. The study also reviews pipe insulation thickness standard in accordance to Korea standard, ASHRAE 90.1 and BS5422 and analyzed through thermal simulation. As a result, it is necessary to apply the performance design method of the pipe insulation thickness to reduce the energy loss of the piping.

IMPROVEMENT OF I-PICTURE CODING USING INTER-PICTURE PROCESSING

  • Arizumi, Masao;Sagara, Naoya;Sugiyama, Kenji
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2009년도 IWAIT
    • /
    • pp.618-622
    • /
    • 2009
  • An improvement of standard encoder has been saturated recently. However, new coding method does not have a compatibility with conventional standard. To solve this problem, new concept coding method that has a semicompatibility with standard may be discussed. On the other hand, cyclic Intra-picture coding is used for access and refreshment. However, I-picture spend large amount of bits. An enhancement of I-picture is desired with keeping its refreshment performance. Further, it's a problem that quality change at the border of GOP because of its independency. To respond these, we propose the coding which is applied an inter-frame processing at the border of GOP. Applied method is the reduction of quantization error using the motion compensated inter-picture processing. In this report, we check the improvement of the efficiency and the compatibility of proposed method. As a result of examination, we recognize that the total gain is maximally 1.2dB in PSNR. Generally, the degradation of performance in standard decoding is smaller than its gain. Also the refreshment performance is tested.

  • PDF

BIM 기반 에너지성능평가를 위한 국내 표준 매개변수 설정 방안에 대한 연구 - 공공청사 업무시설의 재실자 1인당 점유면적을 중심으로 - (A Study on Domestic Standard Parameter Setting for BIM-based Energy Performance Evaluation - Focused on Possession Area per Person of Occupants in Government Offices -)

  • 이윤정;이권형;김인한;추승연
    • 한국CDE학회논문집
    • /
    • 제20권1호
    • /
    • pp.11-21
    • /
    • 2015
  • Currently, the United States, the United Kingdom, Australia etc. are actively utilizing energy simulation for efficiency evaluation of building energy. However, domestic energy efficiency assessment system doesn't use energy simulation system properly at present: parameters based architecture plans and Ashrae Standard are inputted for the evaluation, because the input parameters for the simulation haven't been established yet. This fact causes poor reliability during energy simulation, as the values of the two standards are different from each other. Therefore, the aim of the study is to set domestic standard parameter for BIM-based energy performance evaluation, focusing on possession area per person of occupants at government office in Korea. We found that the difference among the result values occurred approximately 3% in the energy simulation. As a result of the analysis, possession area per person of occupants in Government office is $31.87m^2$. Other input parameters may be set based on this. This will increase the reliability of energy simulation through a domestic standard parameter.

Harmony Matters in Alarm Design: Investigating the Impact of Consonance on Alarm System

  • Ilgang Mukko Lee;Yunsun Alice Hong;Juhyun Jay Lee;Kwanghee Han
    • International Journal of Advanced Culture Technology
    • /
    • 제11권4호
    • /
    • pp.406-416
    • /
    • 2023
  • Alarm system performance is a critical aspect of safety. While existing research has extensively examined the influence of acoustic attributes on alarm performance, consonance's impact remains largely uncharted territory. This study bridges this research gap by investigating the effect of consonance on alarm systems. We extend our investigation to encompass not only the sound characteristics of the alarm but also the acoustic qualities of the surrounding environment, recognizing their potential impact on alarm efficacy. Prior studies consistently link consonance to annoyance levels, resulting in a negative user experience. Thus, we explore the relationship between consonance and alarm system performance, with a particular focus on modulating annoyance as an explanatory factor. Utilizing an oddball paradigm, we categorized standard and oddball sounds into consonant and dissonant types, creating four sound combinations. Participants were asked to respond to the irregularly presented oddball sounds while ignoring the constantly presented standard sounds. Our results reveal significant differences between groups, with the Standard Consonant/Oddball Dissonant (SC/OD) group displaying notably slower response times than the Standard Dissonant/Oddball Consonant (SD/OC) group. This reaction time variation aligns with differences in annoyance levels, as the SC/OD group reports higher annoyance, suggesting that reaction time discrepancies may be linked to increased arousal due to heightened annoyance.

재사용 V4 강재 파이프 서포트의 성능향상 요인에 관한 실험적 연구 (A Experimental Study on Performance Improvement Factors of Used V4 Steel Pipe Support)

  • 최명기;박종근
    • 한국안전학회지
    • /
    • 제35권3호
    • /
    • pp.43-48
    • /
    • 2020
  • It is considered that most of reusable pipe supports, which are used as formwork support posting at construction sites, do not meet the performance standard. Due to the use of reusable pipe supports that do not meet such performance standard the potential risk of collapse accident is increasing. Therefore, this study identifies the status of compliance with performance standard, and presents the requirements for improving quality control to prevent the collapse of pipe supports reused at the construction site. First, if the female thread of the product with no clearance and new support pin with the diameter of 12mm are replaced at the same time for use, it is considered that the performance will be improved. Second, as the quality performance during use can be improved in the case of larger thickness of inner diameter compared to the case of larger thickness of outer diameter, it is necessary to increase the inner pipe thickness greatly than the current thickness. Based on the results of this study, it is expected that the performance the reusable pipe support (V4) can be improved, if the diameter of the support pin is 12mm, the female thread has a small clearance, and the inner tube thickness is 2.3 ~ 2.7mm. In addition, it is considered that other performance improvement factors included in the study results could be used as important data for improving the performance of reusable pipe support.

A Study on Performance Assessment Methods by Using Fuzzy Logic

  • Kim, Kwang-Baek;Kim, Cheol-Ki;Moon, Jung-Wook
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제3권2호
    • /
    • pp.138-145
    • /
    • 2003
  • Performance assessment was introduced to improvement of self-directed learning and method of assessment for differenced learning as the seventh educational curriculum is enforced. Performance assessment is overcoming limitation about problem solving ability and higher thinking abilities assessment that is problem of a written examination and get into the spotlight by way for quality of class and school normalization. But, performance assessment has problems about possibilities of assessment fault by appraisal, fairness, reliability, and validity of grading, ambiguity of grading standard, difficulty about objectivity security etc. This study proposes fuzzy performance assessment system to solve problem of the conventional performance assessment. This paper presented an objective and reliable performance assessment method through fuzzy reasoning, design fuzzy membership function and define fuzzy rule analyzing factor that influence in each sacred ground of performance assessment to account principle subject. Also, performance assessment item divides by formation estimation and subject estimation and designed membership function in proposed performance assessment method. Performance assessment result that is worked through fuzzy performance assessment system can pare down burden about appraisal's fault and provide fair and reliable assessment result through grading that have correct standard and consistency to students.

A Study on Performance Assessment Methods by Using Fuzzy Membership Function and Fuzzy Reasoning

  • Je, Sung-kwan;Jang, Hye-Won;Shin, Bok-Suk;Kim, Cheol-Ki;Jaehyun Cho;Kim, Kwang-Baek
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2003년도 ISIS 2003
    • /
    • pp.608-611
    • /
    • 2003
  • Performance assessment was introduced to improvement of self-directed learning and method of assessment for differenced learning as the seventh educational curriculum is enforced. Performance assessment is overcoming limitation about problem solving ability and higher thinking abilities assessment that is problem of a written examination and get into the spotlight by way for quality of class and school normalization. But performance assessment has problems about possibilities of assessment fault by appraisal, fairness, reliability, and validity of grading, ambiguity of grading standard, difficulty about objectivity security etc. This study proposes fuzzy performance assessment system to solve problem of the conventional performance assessment. This paper presented an objective and reliable performance assessment method through fuzzy reasoning, design fuzzy membership function and define fuzzy rule analyzing factor that influence in each sacred ground of performance assessment to account principle subject. Also, performance assessment item divides by formation estimation and subject estimation and designed membership function in proposed performance assessment method. Performance assessment result that is worked through fuzzy performance assessment system can pare down burden about appraisal's fault and provide fair and reliable assessment result through grading that have correct standard and consistency to students.

  • PDF

Analysis of Energy Performance and Green Strategies in the Foreign High-Performance Buildings

  • Park, Doo-Yong;Kim, Chul-Ho;Lee, Seung-Eon;Yu, Ki-Hyung;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • 제15권3호
    • /
    • pp.21-28
    • /
    • 2015
  • Purpose: In this study, we analyzed the energy performance levels and high-performance technology trends through the case studies of foreign high-performance buildings. Method: Buildings built within 10 years were selected for the analysis of recent trends. we analyzed the buildings of U.S.A, Germany and Japan using LEED certified buildings, Passive House certified buildings and CASBEE certified buildings database for the case study of foreign high-performance buildings. A total of 20 high-performance buildings including 14 cases in U.S.A, 4 cases in Germany and 4 cases in Japan were selected. Annual energy consumption levels for 20 high-performance buildings were collected with the actual energy consumption data or data from simulation programs officially recognized by DOE. Annual energy consumption were compared with the energy performance standard of the office buildings in the CBECS database, ASHRAE Standard 90.1-2004 and Building Energy Efficiency Rating System in Korea. Result: The order of the green strategies applied in the main categories are Renewable Energy(63%), Indoor Environment Control(51%), Envelope Improvement(44%) and HVAC System & Control(28%). Specified strategies most widely used in the sub-categories are high-performance Insulation (70%), High Efficiency Heating, Cooling Source Equipment(85%), Photovoltaic&Solar Thermal(80%) and Daylighting(80%).

경영시스템 도입 중소기업의 품질이행율 향상을 위한 품질기록 관리운영의 표준화 사례연구 (Introduction of Management System Case Study on Standardization of Quality Record Management to Improve Quality Performance Rate of SMEs)

  • 조철희;박병화;박진이
    • 품질경영학회지
    • /
    • 제47권4호
    • /
    • pp.911-926
    • /
    • 2019
  • Purpose: In an infinite market competition, companies are adopting management systems to gain a competitive advantage. The expectancy effect of the management system is management performance improvement and accurate measurements. These can be made through quality records with integrity and maintainability. This paper examines the operation of records management standards, which are records, storage and management standards for quality records to understand the needs of records management standards and empathize with their needs. Methods: This paper examines PEC's (Pields Engineering Co., Ltd.) specific processes and standards for integrating individual management systems and establishing records management standards. We also look at the specific features of the Search Tool and Document Storage Management Standards that support records management standards. Results: The integration process of PEC's individual management system consists of five steps. A PDCA-based process was established to erode the confusion and inefficiencies caused by overlap between individual management systems. Also, by accurately grasping corporate competence, PEC established a record management standard suitable for the characteristics of the company. PEC's records management standards are used as a useful standard for organizing quality records, and have an impact on management performance improvement. Conclusion: PEC's records management standards enable the verification of quality performance rates and performance measures. Companies can implement appropriate quality improvement strategies based on the numbers identified by introducing records management standards. Companies can succeed in improving management performance when operating quality management that combines performance measurement techniques and records management standards.

Influence of Service Characteristics on High Priority Performance Indicators and Standards in the BreastScreen Australia Program

  • Roder, David Murray;Ward, Gail Heather;Farshid, Gelareh;Gill, Peter Grantley
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권14호
    • /
    • pp.5901-5908
    • /
    • 2014
  • Background: Data from BreastScreen Australia Screening and Assessment Services (SAS) for 2002-2010 were analysed to determine whether some SAS characteristics were more conducive that others to high screening performance, as indicated by high priority performance indicators and standards. Materials And Methods: Indicators investigated related to: numbers of benign open biopsies, screen-detected invasive cancers, and interval cancers, and wait times between screening and assessment. Multivariate Poisson regression was undertaken using as candidate predictors of performance, SAS size (screening volume), urban or rural location, year of screening, accreditation status, and percentages of clients from culturally and linguistically diverse backgrounds, rural and remote areas, and socio-economically disadvantaged areas. Results: Performance standards for benign biopsies and invasive cancer detection were uniformly met irrespective of SAS location and size. The interval cancer standard was also met, except in 2003 when the 95% confidence interval of the rate still incorporated the national standard. Performance indicators improved over time for: benign open biopsy for second or subsequent screening rounds; rates of invasive breast cancer detection for second or subsequent screening rounds; and rates of small cancer detection. No differences were found over time in interval cancer rates. Interval cancer rates did not differ between non-metropolitan and metropolitan SAS, although state-wide SAS had lower rates. The standard for wait time between screening and assessment (being assessed ${\leq}28$ days) was mostly unmet and this applied in particular to SAS with high percentages of culturally and linguistically diverse women in their screening populations. Conclusions: Gains in performance were observed, and all performance standards were met irrespective of SAS characteristics, except wait times to assessment. Additional descriptive data should be collected on SAS characteristics, and their associations with favourable screening performance, as these may be important when deciding on SAS design