• 제목/요약/키워드: Performance Demonstration

검색결과 400건 처리시간 0.026초

보육교사 대상의 영아 심폐소생술 현장교정교육의 효과 (The CPR Educational Program Effect of Infant CPR Immediate Remediation for Child Care Teachers)

  • 김일옥;신선화
    • 한국간호교육학회지
    • /
    • 제19권4호
    • /
    • pp.508-517
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the effectiveness of infant CPR (Cardiopulmonary Resuscitation) immediate remediation[LAB2]. Methods: This is a quasi-experimental study with a non-equivalent comparison group pre-post test design. Participants were 73 child care teachers in J district in Seoul. The experimental group (35) received immediate remediation with video learning [LAB3]for infant CPR education and the control group (38) received video learning only. We investigated confidence of infant CPR and tested single-rescuer infant CPR performance depending on a checklist (8 items). Data were collected before and right after to evaluate the confidence of infant CPR and before, right after and 2 weeks after the education to evaluate the skill performance and final acceptance. Results: There was a significant increase in confidence of infant CPR in the experimental group and control group. There was a statistically significant difference in the degree of skill performance between groups according to the amount time (F=10.58, p<.001). The degree of skill performance was tested two weeks after the education and immediate remediation was 5.35 times more effective compared to the video image demonstration (B=1.677, p<.001). Conclusion: The findings provide the necessity of immediate remediation education of infant CPR to increase confidence and skill performance ability.

기계적 특성이 우수한 원통형 복합재료 안테나의 설계 및 충격 실험 (Design and Impact Testing of Cylindrical Composite-Antenna-Structures having High Mechanical Performanc)

  • 김동섭;조상현;황운봉;이중희
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.35-38
    • /
    • 2005
  • The Objective of this work was to design Composite Antenna Structures (CAS) and investigate impact behavior of CAS which was various curvature. This term, CAS, indicates that structural surface becomes antenna. Constituent materials were selected considering electrical properties, dielectric constants and tangent loss as well as mechanical properties. For the antenna performance, microstrip antenna layers inserted into structural layers were designed for satellite communication at the resonant frequency of 12.5 GHz and final demonstration article was. After making five kinds of curved CAS, which radii of curvature are flat, 200, 150, 100, 50 mm. The antenna performance changed in accordance with variation of curvature. The Reflection coefficient was independent of curvature but the gain decreased with the radius of curvature. The impact test equipment was Dyna-8250 drop weight tester. The impact characteristic in accordance with curvature is maximum absorb energy is same each other. The impact energy was 8.5 J. For various Impact energy test, five energy levels 3 J, 5 J, 7 J, 10 J, 20 J were used. The performance of impact damaged antenna was estimated by measuring the return loss and the radiation pattern. It was revealed that the performance of antenna was not related to the impact damage. Because the impactor did not damage the patch directly. CAS have good impact stability for the antenna performance.

  • PDF

PVDF 중공사막을 이용한 진공 막 증류 모듈의 공급수 조건에 따른 열성능 특성에 관한 실험적 연구 (An Experimental Study on the Characteristic of Thermal Performance according to Feed Water Conditions to of Vacuum Membrane Distillation Module using PVDF Hollow Fiber)

  • 주홍진;곽희열
    • 상하수도학회지
    • /
    • 제31권4호
    • /
    • pp.339-346
    • /
    • 2017
  • In this study, thermal performance test of VMD module was performed, prior to the construction of the demonstration plant using the vacuum membrane distillation (VMD) module of the capacity of $400m^3/day$ and to the commercialization of the VMD module. For the thermal performance test, the experimental equipment of capacity of $2m^3/day$ was constructed. The permeate flux test and thermal performance test according to feed water conditions such as temperature and flow rate were conducted. The VMD module used in the study was manufactured by ECONITY Co., LTD with PVDF hollow fiber membrane. As a result, the Performance Ratio (PR) of the VMD module showed the maximum value of 0.904 under the condition of feed water temperature of $75^{\circ}C$ and flow rate of $8m^3/h$. PR value of the VMD module using PVDF hollow fiber membrane showed linearly increasing relationship with feed water temperature and flow rate. Also, The permeate flux of the VMD module was analyzed to have maximum value of 18.25 LMH and the salt rejection was 99.99%.

High-Performance Q-Band MMIC Phase Shifters Using InGaAs PIN Diodes

  • Kim, Mun-Ho;Yang, Jung-Gil;Yang, Kyoung-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • 제9권3호
    • /
    • pp.159-163
    • /
    • 2009
  • This paper presents the design and implementation of Q-band MMIC phase shifters using InGaAs PIN diodes. The topology using a thin-film microstrip line(TFMS) has been proposed to achieve the desired phase-shift as well as good loss characteristics. Five single-bit MMIC phase shifters have been implemented by using a developed BCB(benzocyclobutene)-based multi-layer fabrication technology. The developed phase shifters have less than 3.4 dB of insertion loss and better than 11 dB of input and output return loss in the frequency range of 43 to 47 GHz. To the authors' knowledge, this is the first demonstration of high-performance InGaAs PIN diode-based MMIC phase shifters operating at Q-band frequencies.

100kW급 MCFC용 계통연계형 전력변환기 개발 (The Development of Power Conditioning System for 100kw MCFC Systems)

  • 정홍주;정준모;서인영;임희천;김도형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.55-57
    • /
    • 2005
  • This paper presents the development and performance of a power conditioning system (PCS) for application to a 100kw Molten Carbonate Fuel Cell. (MCFC) generation system. The MCFC generation system is a part of a four year government funded research project that began in 2001. This paper presents the results of operation connected to an actual fuel cell stack at a field demonstration site. and this paper shows various tests and performance verification of the 100kW PCS using a simulated DC source.

  • PDF

원전 배관 초음파 비파괴검사의 신뢰도 평가 - PD-RR Test Results - (I) (Reliability Assessment of Ultrasonic Nondesturcive Inspection on Piping in NPP - The Result of PD-RR Test - (Part I))

  • 박익근;박은수;김현묵;박윤원;강석철;최영환;이진호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.246-251
    • /
    • 2001
  • The performance demonstration round robin test was conducted to quantify the capability of ultrasonic inspection for in-service and to address some aspects of reliability for nondestructive evaluation. The fifteen inspection teams who employed procedures that met or exceeded ASME Sec. XI code requirements detected the pinping of nuclear power plant with various cracks to evaluate the capability of detection. With data from PD-RR test, the performance of ultrasonic nondestructive inspection could be assessed using probability of detection and length and depth sizing of cracks.

  • PDF

다축힘센서의 노이즈신호 개선을 위한 신호처리 방법 (Signal Processing Method for Noise Reduction of Multi-Axis Force Sensors)

  • 김용찬;강철구;남현도
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1026-1029
    • /
    • 2003
  • There are always some errors in force sensing of multi-axis force sensors that aggravate sensor performance. Error sources may be classified mainly in two groups. One is structural error due to inaccuracy of sensor body, and the other is error due to noise signals existing in the sensed information. This paper presents a brief review about the principle of multi-axis force sensors, and then a method that can reduce the effect of noise signals. The method is to read digital signals in computer instead of analog voltage signals. We can eliminate the bad effect of electromagnetic waves emitted from computer and of 60 Hz noise emitted from AC source by the proposed method. The proposed method is investigated through experimental demonstration. The experimental results show the proposed method improves the sensor performance significantly.

  • PDF

Demonstration of Mobile Fronthaul Test Bed Based on RoF Technology Supporting Two Frequency Assignments and 2 × 2 MIMO Antennas

  • Cho, Seung-Hyun;Han, Changyo;Chung, Hwan Seok;Lee, Jong Hyun
    • ETRI Journal
    • /
    • 제37권6호
    • /
    • pp.1055-1064
    • /
    • 2015
  • We demonstrate a next-generation high-capacity mobile fronthaul based on radio over fiber (RoF) technology, which links between a digital unit and a radio unit supporting two frequency assignments and $2{\times}2$ multiple input, multiple output antennas. To confirm the technical feasibility of a mobile fronthaul, we experimentally investigate its down- and uplink end-to-end performances including the optical and radio frequency (RF) signal path. Frequency-dependent performance deviations, error vector magnitude variations, overall system performance variations caused by optical to electrical conversion, and intermediate frequency to RF conversions are examined. Experimental verifications on multiple LTE uplink signals are performed for the first time. We also demonstrate several commercial mobile Internet services, YouTube video streaming, and file transfers using off-the-shelf mobile devices, through a mobile fronthaul based on RoF.

신재생에너지를 이용한 철도역사용 복합형 가로등 설계 (Design of Hybrid Type Streetlight for Railway Station with Renewable Energy)

  • 윤용호;김재문
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2103-2108
    • /
    • 2016
  • Energy saving is as important as developments of green energy and alternative energy. This paper describes design of hybrid type streetlight for railway station with renewable energy as photovoltaic, wind, secondary battery. In designing hybrid type streetlight for railway station, generation energy with renewable energy and reliability is strongly needed to meet the demand of railway station. In order to achieve the high performance of a streetlight, photovoltaic, wind and secondary battery system, PV tracker, monitoring and GUI system with logging function are designed. To verify of performance of hybrid type streetlight for railway station, we have demonstration test to get of generation energy and flow of energy and the results are present in this paper.

M&S 기반 어뢰방어전 모의실험 기술 구현 (The Development of Torpedo Defense Experimental Technique based on M&S)

  • 나영인;이심용;윤한샘
    • 한국군사과학기술학회지
    • /
    • 제13권5호
    • /
    • pp.818-823
    • /
    • 2010
  • Exploiting models and simulations are encouraged among the defense acquisition society, as now enforced by the Defense Aquisition Program Administration's regulations. They are useful and, sometimes, inevitable especially in an earlier phase of system development. Computer-simulation-based experimentation technique for the system operational performance analysis for a torpedo defense system is introduced in this paper. Problem definition for the torpedo defense system analysis and engineering efforts for models and simulations development are presented here, including defining measures of performance and effectiveness for the torpedo defense system, conceptual modeling for torpedo engagement and defense simulation, design of experimentation, design of simulator and experimentor, and hardware and software implementation of an analysis support tool - a system operations demonstration and experimentation simulator.