• 제목/요약/키워드: Penrose

검색결과 70건 처리시간 0.028초

THE GENERALIZED WEIGHTED MOORE-PENROSE INVERSE

  • Sheng, Xingping;Chen, Guoliang
    • Journal of applied mathematics & informatics
    • /
    • 제25권1_2호
    • /
    • pp.407-413
    • /
    • 2007
  • In this paper, we definite a generalized weighted Moore-Penrose inverse $A^{+}_{M,N}$ of a given matrix A, and give the necessary and sufficient conditions for its existence. We also prove its uniqueness and give a representation of it. In the end we point out this generalized inverse is also a prescribed rang T and null space S of {2}-(or outer) inverse of A.

RIGHT AND LEFT QUOTIENT OF TWO BOUNDED OPERATORS ON HILBERT SPACES

  • Benharrat, Mohammed
    • 대한수학회논문집
    • /
    • 제35권2호
    • /
    • pp.547-563
    • /
    • 2020
  • We define a left quotient as well as a right quotient of two bounded operators between Hilbert spaces, and we parametrize these two concepts using the Moore-Penrose inverse. In particular, we show that the adjoint of a left quotient is a right quotient and conversely. An explicit formulae for computing left (resp. right) quotient which correspond to adjoint, sum, and product of given left (resp. right) quotient of two bounded operators are also shown.

COMPLETIONS OF HANKEL PARTIAL CONTRACTIONS OF SIZE 5×5 NON-EXTREMAL CASE

  • Lee, Sang Hoon
    • 충청수학회지
    • /
    • 제29권1호
    • /
    • pp.137-150
    • /
    • 2016
  • We introduce a new approach that allows us to solve, algorithmically, the contractive completion problem. In this article, we provide concrete necessary and sufficient conditions for the existence of contractive completions of Hankel partial contractions of size $4{\times}4$ using a Moore-Penrose inverse of a matrix.

The Moore-Penrose Inverse for the Classificatory Models

  • Kim, Byung-Chun;Lee, Jang-Taek
    • Journal of the Korean Statistical Society
    • /
    • 제15권1호
    • /
    • pp.46-61
    • /
    • 1986
  • Many procedures for deriving the Moore-Penrose invese $X^+$ have been developed, but the explicit forms of Moore-Penerose inverses for design matrices in analysis of variance models are not known heretofore. The purpose of this paper is to find explicit forms of $X^+$ for the one-way and the two-way analysis of variance models. Consequently, the Moore-Penerose inverse $X^+$ and the shortest solutions of them can be easily obtained to the level of pocket calculator by way of our results.

  • PDF

무정보 blur 이미지 복구를 위한 DFT 변환 (A DFT Deblurring Algorithm of Blind Blur Image)

  • 문경일;김철
    • 정보교육학회논문지
    • /
    • 제15권3호
    • /
    • pp.517-524
    • /
    • 2011
  • 어떠한 현상 혹은 사물의 이미지를 학생들에게 제공하는데 있어서 여러 가지 원인에 의해 초점이 흐리거나 혹은 흔들린 이미지들이 등장하여 학생들에게 보여주기가 힘든 경우가 빈번하게 발생한다. 특히, 이미지에 대한 구체적인 정보가 없는 경우에는 그 이미지는 쓸모가 없는 것이 된다. 본 연구는 무정보 블러링 이미지를 아주 빠른 시간 내에 복구할 수 있는 2차원 DFT 기반의 하나의 블러링 제거 알고리즘을 제안하는데 있다. 제안된 방법의 빠른 처리 속도는 이산 푸리에 변환, 변환의 필터링과 회선 관계 및 Moore-Penrose 역행렬의 효과적인 계산 방식을 바탕으로 한다. 특히, 필터의 주파수 응답에 관한 처리는 유용한 회선 공식을 유도한다. 제안된 방법의 구현은 보통 크기의 블러링 이미지에 적용했을 때, 아주 빠른 시간 내에 블러링 효과를 제거시킬 수 있고, 보다 선명한 이미지를 제공할 수 있음을 보인다.

  • PDF

Flow Dynamics Near End-To-End Anastomoses - Part I. In Vitro Compliance Measurement -

  • Kim, Y.H
    • 대한의용생체공학회:의공학회지
    • /
    • 제13권2호
    • /
    • pp.165-174
    • /
    • 1992
  • Compliance mismatch across an end-to-end anastomosis was measured In the In vitro experimental setup. A 35mm camera was used and Image process was done in Gould/ DeAnza Image processor. The results showed that compliances of Penrose tubing and synthetic PTFE grafts were In good agreement with the previously reported In vivo data. PTFE grafts exhibited a nonlinear behavior with compliance decreasing with Increasing transmural pressure, whereas the compliance of the Penrose tubing remained relatively constant within the range of the pressures in which data were obtained. The lumen cross sections at the anastomosis were affected by the suture and the mismatch In compliance between the Penrose tubing and vascular grafts. The varla~lons In the lumen dtameter at the anastomosis was more pronounced with increasing transmural pressures. From the present study, it was clearly demonstrated that the compliance of prosthetic grafts Is much lower than that of the arteries. In addition to the hemodynamlc consequences, compliance mismatch across the anastomosis has been known to lead to Increased anastomotlc and suture stresses with resultant suture line dehlscence and false aneurysm formation. Thus, there are good hemodynamic reasons to suppose that Introduction of a less compliant arterial graft Into the arterial circulation wlll be damaging and that grafts should be made to match the elastic behavior of their host arteries as closely possible.

  • PDF

변위제약을 받는 평면트러스 구조물의 형태해석기법에 관한 연구 (A Study on the Shape Analysis Method of Plane Truss Structures under the Prescribed Displacement)

  • 문창훈;한상을
    • 전산구조공학
    • /
    • 제11권1호
    • /
    • pp.217-226
    • /
    • 1998
  • 본 논문은 변위제약모드를 갖는 트러스구조물의 형태해석을 목적으로 하였으며, 이를 위하여 해의 존재조건과 무어-펜로즈(Moore-Penrose) 일반역행렬을 이용하였다. 또한, 수치해석과정에서의 변위제약모드로는 호몰로지변형(homologous deformation)을 고려하여 해석하였고, 다음으로 다양한 변위제약모드와 절점에 작용하는 하중비를 만족하는 구조물의 형태를 구하였다. 본 논문에서의 형태해석문제는 지정된 변위를 만족하는 구조물의 형태를 찾는 일종의 역문제(inverse problem)로서 일반적인 구조해석과정과는 반대되는 입장에서 접근하였다. 또한, 본 논문에서는 수치해석과정에서 근사해의 정도를 향상시키기 위하여 뉴튼-랩슨법을 사용하였고, 수치해석예제로서 부재의 배열형태에 따라 3가지모델을 선택하였으며, 이들 모델을 통하여 적용한 해석기법의 정확성과 효율성을 검증하였다.

  • PDF

A Novel Mediastinal Drainage Tube for Mediastinitis

  • Yhang, Jun Ho;Jang, In-Seok;Kim, Sung Hwan;Park, Hyun Oh;Kang, Dong Hoon;Choi, Jun Young
    • Journal of Chest Surgery
    • /
    • 제48권5호
    • /
    • pp.378-379
    • /
    • 2015
  • Mediastinitis is a life-threatening disease, and effective drainage is needed to treat mediastinitis with abscess formation. We recommend an alternative drainage method using chest tube binding with a Silastic Penrose drainage tube. The use of a Silastic Penrose drainage tube may help to manage mediastinitis with abscess formation. This method facilitates effective draining and prevents tissue adhesion.