• Title/Summary/Keyword: Penetration Ratio

Search Result 678, Processing Time 0.037 seconds

Analysis of Failure Behavior of FRP Rebar Reinforced Concrete Slab based on FRP Reinforced Ratio (FRP 보강근비에 따른 FRP 보강 콘크리트 슬래브의 파괴거동 분석)

  • Jang, Nag-Seop;Kim, Young-Hwan;Oh, Hong-Seob
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.5
    • /
    • pp.173-181
    • /
    • 2021
  • Reinforced concrete structures are exposed to various environments, resulting in reinforcement corrosion due to moisture and ions penetration. Reinforced concrete corrosion causes a decrease in the durability performance of reinforced concrete structures. One solution to mitigate such issues is using FRP rebars, which offer several advantages such as high tensile strength, corrosion resistance, and light-weight than conventional rebars, in reinforced concrete instead of conventional steel rebars. The FRP rebar used should be examined at the limit state because FRP reinforced concrete has linear behavior until its fracture and can generate excessive deflection due to the low elastic modulus. It should be considered while designing FRP reinforced concrete for flexure. In the ultimate limit state, the flexural strength of FRP reinforced concrete as per ACI 440.1R is significantly lower than the flexural strength by applying both the environmental reduction and strength reduction factors accounting for the material uncertainty of FRP rebar. Therefore, in this study, the experimental results were compared with the deflection of the proposed effective moment of inertia referring to the local and international standards. The experimental results of GFRP and BFRP reinforced concrete were compared with the flexural strength as determined by ACI 440.1R and Fib bulletin 40. The flexural strength obtained by the experimental results was more similar to that obtained by Fib bulletin 40 than ACI 440.1R. The flexural strength of ACI 440.1R was conservatively evaluated in the tension-controlled section.

Durability Evaluation of Cement Concrete Using Ferrosilicon Industrial Byproduct (페로실리콘 산업부산물 활용 시멘트 콘크리트의 내구성능 평가)

  • Chang-Young Kim;Ki Yong Ann
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.1
    • /
    • pp.89-96
    • /
    • 2023
  • In this paper, a ferrosilicon by-product was evaluated to confirm the feasibility of recycling it as supplementary cementitious material of ordinary Portland cement in concrete. Three different levels of replacement ratio (10 %, 20 % and 30 % of total binder) were applied to find which is the most beneficial to be used as a binder. Ferrosilicon concrete was initially assessed at setting time and compressive strength. Durability was evaluated by the resistance to chloride penetration test(RCPT) and alkali-silica reaction(ASR) with a comparison to silica fume concrete due to their similarity in chemical composition. The porosimetry and X-ray diffraction analysis along with energy dispersive X-ray spectroscopy give information on the microstructural characteristics of the ferrosilicon concrete. It was found that 10 % ferrosilicon concrete has higher strength while 20 %, 30 % have lower strength than OPC concrete. However, chemical resistance to chloride attack is higher when replacement is increased. Compared to silica fume, the durability of ferrosilicon might be less efficient however, it is obviously beneficial than OPC. High SiO2 content in ferrosilicon results in producing more C-S-H gel which could make denser pore structure. Most of the risk of alkali silica reaction to silicate binders through length change tests was less than 0.2 %, and both mortar using ferrosilicon and silica fume showed better resistance to alkali silica reaction as the substitution rate increased.Reuse of industrial waste rather than producing highly refined additives might reduce environmental load during manufacture and save costs.

Material Discrimination Using X-Ray and Neutron

  • Jaehyun Lee;Jinhyung Park;Jae Yeon Park;Moonsik Chae;Jungho Mun;Jong Hyun Jung
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.4
    • /
    • pp.167-174
    • /
    • 2023
  • Background: A nondestructive test is commonly used to inspect the surface defects and internal structure of an object without any physical damage. X-rays generated from an electron accelerator or a tube are one of the methods used for nondestructive testing. The high penetration of X-rays through materials with low atomic numbers makes it difficult to discriminate between these materials using X-ray imaging. The interaction characteristics of neutrons with materials can supplement the limitations of X-ray imaging in material discrimination. Materials and Methods: The radiation image acquisition process for air-cargo security inspection equipment using X-rays and neutrons was simulated using a GEometry ANd Tracking (Geant4) simulation toolkit. Radiation images of phantoms composed of 13 materials were obtained, and the R-value, representing the attenuation ratio of neutrons and gamma rays in a material, was calculated from these images. Results and Discussion: The R-values were calculated from the simulated X-ray and neutron images for each phantom and compared with those obtained in the experiments. The R-values obtained from the experiments were higher than those obtained from the simulations. The difference can be due to the following two causes. The first reason is that there are various facilities or equipment in the experimental environment that scatter neutrons, unlike the simulation. The other is the difference in the neutron signal processing. In the simulation, the neutron signal is the sum of the number of neutrons entering the detector. However, in the experiment, the neutron signal was obtained by superimposing the intensities of the neutron signals. Neutron detectors also detect gamma rays, and the neutron signal cannot be clearly distinguished in the process of separating the two types of radiation. Despite these differences, the two results showed similar trends and the viability of using simulation-based radiation images, particularly in the field of security screening. With further research, the simulation-based radiation images can replace ones from experiments and be used in the related fields. Conclusion: The Korea Atomic Energy Research Institute has developed air-cargo security inspection equipment using neutrons and X-rays. Using this equipment, radiation images and R-values for various materials were obtained. The equipment was reconstructed, and the R-values were obtained for 13 materials using the Geant4 simulation toolkit. The R-values calculated by experiment and simulation show similar trends. Therefore, we confirmed the feasibility of using the simulation-based radiation image.

A Study on the Strategy of Korean Logistics Companies to Enter the Cambodia E-Commerce Market (한국 물류기업의 캄보디아 전자상거래 시장 진출 전략에 관한 연구)

  • Ji-Won Lee;Hyang-Sook Lee
    • Korea Trade Review
    • /
    • v.48 no.2
    • /
    • pp.111-127
    • /
    • 2023
  • While the e-commerce market in Southeast Asia is growing, this study aims to derive factors for establishing an entry strategy for the Cambodian e-commerce market where Korean logistics companies can strategically enter in the future. Cambodia is a country where growth and growth potential in the e-commerce market is steadily increasing based on the high youth population ratio, high smartphone penetration rate, the introduction of convenient payment systems, and government-level e-commerce promotion policies. In this study, Korean logistics companies established detailed promotion strategies by deriving factors necessary for Cambodia's entry into the e-commerce market and analyzing their relative importance. The AHP analysis technique derived three top factors for the entry strategy, and each presented four sub-factors. As a result, the importance was shown in the order of 'Market Factor' (0.556), 'Policy and Institutional Factor' (0.295), and 'Corporate Competency Factor' (0.149). As a result of the sub-factors analysis, the importance was found in the order of "Characteristics and Growth Potential of Distribution Channel" (0.230), "Purchasing Power and Awareness Level of Consumers" (0.176), "Cambodia Government's E-commerce Policy and Institutional Support" (0.122), and "Cambodia Government's Logistics Infrastructure Plan" (0.108). In both the upper and lower factors, the characteristics and growth potential of the Cambodian e-commerce market were important, indicating that Korean logistics companies value market size and growth potential to enter the Cambodian e-commerce market. The results of this study can be used as a guideline to help Korean logistics companies make successful inroads into Cambodia, where the e-commerce market is expected to grow in the future.

Large Firms and M&A Trends in the Digital Transformation Era: Implications for Productivity (디지털 전환 시대의 지배적 기업과 인수합병: 생산성에 미치는 영향)

  • Young Bong Chang;YoungOk Kwon;Wooje Cho
    • Information Systems Review
    • /
    • v.24 no.4
    • /
    • pp.41-54
    • /
    • 2022
  • Despite the recent rapid advancement of science and technology, we have been experiencing the decline in productivity since the 2000s. This study aims to investigate the decline at both industry and firm levels, by looking at the emergence and growth of large firms such as Amazon, Alphabet, and Apple and M&A trends. Following the results of previous studies, our results show that productivity at industry level has decreased since the 2000s. Particularly, in the period after 2011, the deterioration of allocative efficiency due to the large firms and the decline in the growth rate of surviving firms in the industry with low ratio of large firms contributed to the productivity decline. On the other hand, our analysis at firm level demonstrates that the productivity of firms that acquired IT firms improved over the entire period. While M&As have a positive impact on productivity, M&As with a demand-side motive such as market penetration and expansion of channels have a relatively larger impact than the ones for production or operation efficiency. Our results also suggest that the higher the proportion of large firms in a specific industry, the lower the productivity of individual firms in the same industry. Overall, given that the industry's structural changes for digital transformation tends to strengthen the growth of large firms, our findings have significant implications by empirically identifying the relationships of the emergence of large firms, the acquisition of IT/Non-IT firms, and motivations for M&As to firm/industry productivity.

Experimental Study to Evaluate the Durability of 100 MPa Class Ultra-high Strength Centrifugal Molding Concrete (100MPa급 초고강도 원심성형 콘크리트의 내구성 평가를 위한 실험연구)

  • Jeong-Hoi Kim;Sung-Jin Kim;Doo-Sung Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.1
    • /
    • pp.12-23
    • /
    • 2024
  • In this study, a structural concrete square beam was developed using the centrifugal molding technique. In order to secure the bending stiffness of the cross section, the hollow rate of the cross section was set to 10% or less. Instead of using the current poor mixture of concrete and a concrete mixing ratio with a high slump (150-200) and a design strength of 100 MPa or more was developed and applied. In order to investigate the durability of centrifugally formed PSC square beams to be used as the superstructure of the avalanch tunnel or ramen bridge, the durability performance of ultra-high-strength centrifugally formed concrete with a compressive strength of 100 MPa was evaluated in terms of deterioration and chemical resistance properties.Concrete durability tests, including chloride penetration resistance, accelerated carbonation, sulfate erosion resistance, freeze-thaw resistance, and scaling resistance, were performed on centrifugally formed square beam test specimens produced in 2022 and 2023. Considering the information verified in this study, the durability of centrifugally molded concrete, which has increased watertightness in the later manufacturing stage, was found to be superior to that of general concrete.

The Early-Stage Changes of Water Qualities after the Saemangeum Sea-dike Construction (새만금 방조제 체절 이후 초기의 수질변화에 관한 연구)

  • Yang, Jae-Sam;Jeong, Yong-Hoon;Ji, Kwang-Hee;Kim, Hyun-Soo;Choi, Joeng-Hoon;Kim, Won-Jang
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.11 no.4
    • /
    • pp.199-213
    • /
    • 2008
  • Saemangeum salt-water Lake has been created by the completion of the sea-dike in April 2006. To monitor the water qualities of the lake during the sea-dike construction, salinity, SS, nutrients(DIN, DIP, DISi), and chlorophyll-$\alpha$ was analyzed for the surface water from 1999 to 2007. Due to the dike construction, weaker tidal current and lesser resuspension of bottom sediment resulted in the marked decrease of the concentrations of SS in the lake water. Consequently the clearer lake water has provided better condition for primary production with deeper penetration of sunlight into the water column and sufficient nutrient content in the water. Finally the chlorophyll-$\alpha$ content became approximately double in the concentration after the dike construction. Highly stimulated algal production with the marked decrease of the concentrations of SS was decreased the concentration of DIP in the surface water. On the other hand the concentration of DIN and DISi in surface water was increased after dike construction due to the expansion of the freshwater and the supply from bottom layer. As a result, the lake revealed an extremely high NIP ratio and a DIP-limited ecosystem. The lake has been transformed from a typical coastal ecosystem to a brackish one. Since the dike completion, the lake has shown a similar change pattern to the Geum River estuary. Due to the salt-wedge intrusion of seawater, it is highly probable to expect the formation of low-oxygen zone at the bottom layer near the river-mouth area of the lake during the summer. Therefore we need a continuous sentinel monitoring of bottom water qualities in the near future.

  • PDF

Comparison of Collimator Choice on Image Quality of I-131 in SPECT/CT (I-131 SPECT/CT 검사의 에서 조준기 종류에 따른 영상 비교 평가)

  • Kim, Jung Yul;Kim, Joo Yeon;Nam-Koong, Hyuk;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.33-42
    • /
    • 2014
  • Purpose: I-131 scan using High Energy (HE) collimator is generally used. While, Medium Energy (ME) collimator is not suggested to use in result of an excessive septal penetration effects, it is used to improve the sensitivities of count rate on lower dose of I-131. This research aims to evaluate I-131 SPECT/CT image quality using by HE and ME collimator and also find out the possibility of ME collimator clinical application. Materials and Methods: ME and HE collimator are substituted as Siemens symbia T16 SPECT/CT, using I-131 point source and NEMA NU-2 IQ phantom. Single Energy Window (SEW) and Triple Energy Windows (TEW) are applied for image acquisition and images with CTAC and Scatter correction application or not, applied different number of iteration and sub set are reconstructed by IR method, flash 3D. By analysis of acquired image, the comparison on sensitivities, contrast, noise and aspect ratio of two collimators are able to be evaluated. Results: ME Collimator is ahead of HE collimator in terms of sensitivity (ME collimator: 188.18 cps/MBq, HE collimator: 46.31 cps/MBq). For contrast, reconstruction image used by HE collimator with TEW, 16 subset 8 iteration applied CTAC is shown the highest contrast (TCQI=190.64). In same condition, ME collimator has lower contrast than HE collimator (TCQI=66.05). The lowest aspect ratio for ME collimator and HE collimator are 1.065 with SEW, CTAC (+) and 1.024 with TEW, CTAC (+) respectively. Conclusion: Selecting a proper collimator is important factor for image quality. This research finding tells that HE collimator, which is generally used for I-131 scan emitted high energy ${\gamma}$-ray is the most recommendable collimator for image quality. However, ME collimator is also applicable in condition of lower dose, lower sensitive if utilizing energy window, matrix size, IR parameter, CTAC and scatter correction appropriately.

  • PDF

Preparation of Liquid Crystal Emulsion for Transdermal Delivery of Glycyrrhizic Acid and Physical Characteristics and In Vitro Skin Permeation Studies (글리시리직애씨드의 경피 전달을 위한 액정 에멀젼의 제조와 물리적 특성 및 In Vitro 피부투과 연구)

  • Jung, Jin Woo;Yoo, Cha Young;Park, Soo Nam
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.4
    • /
    • pp.315-324
    • /
    • 2015
  • In this study, we prepared liquid crystal emulsion composed of amphiphilic substance $C_{14-22}$ alcohol, $C_{12-20}$ alkyl glucoside, behenyl alcohol and studied liquid crystal emulsion of properties and in vitro skin permeation. The results of formulation experiments, the clear liquid crystalline structure was observed in the ratio of $C_{14-22}$ alcohol 0.8%, $C_{12-20}$ alkyl glucoside 3.2%, behenyl alcohol 4% in the formulation. The results of physical property measurements, the viscosity of liquid crystal emulsion and O/W emulsion applied as a control group was respectively $1871.26{\sim}1.15Pa{\cdot}s$, $1768.69{\sim}1.14Pa{\cdot}s$ and the shear stress of O/W emulsion was 178.68 ~ 909.18 Pa, that of liquid crystal emulsion was 190.45 ~ 919.38 Pa. The storage modulus of O/W emulsion was 3428.53 ~ 9157.45 Pa, that of liquid crystal emulsion was 4487.82 ~ 8195.59 Pa. The tan (delta) value of O/W emulsion which means a ratio of viscosity to elasticity was 0.43 ~ 0.19, and that of liquid crystal emulsion was 0.23 ~ 0.25. The water content value on the skin for liquid crystal emulsion was significantly higher from 1 h to 6 h compared with that of O/W emulsion and the transepidermal water loss on the skin was significantly superior in skin moisture loss suppression from 30 min to 4 h compared with that of O/W emulsion. The results of skin permeation using glycyrrhizic acid, the result of skin permeation amount of liquid crystal emulsion for 24 h was $64.58{\mu}g/cm^2$, that of O/W emulsion was $37.07{\mu}g/cm^2$, that of butylene glycol solution was $41.05{\mu}g/cm^2$. Hourly permeability results, it is showed that skin penetration effect of the liquid crystal emulsion increases after 8 h. These results suggest that liquid crystal emulsions are effective for skin moisturizing effect and function as potential efficacy ingredient delivery system for the transdermal delivery.

In vitro study of microleakage of endodontically treated teeth restored with different adhesive systems and fiber-reinforced posts (다양한 접착시스템을 이용하여 섬유 강화형 포스트로 수복한 치아에서의 미세누출에 관한 연구)

  • Park, Joon-Ho;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.74-81
    • /
    • 2014
  • Purpose: While studies have examined microleakage in endodontically treated teeth restored with posts, microleakage among post and adhesive systems remains a concern. This study compared the sealing properties of 3 adhesively luted post systems. Materials and methods: Thirty-six endodontically treated permanent maxillary central incisors were divided into 3 groups: Zirconia-glass fiber, Quartz-glass fiber, Polyethylene fiber posts. Post space was prepared and each post was adhesively luted with 3 systems. The specimens were separately immersed in freshly prepared 2% methylene blue solution for 1 week. The cleaned specimens were then embedded in autopolymerizing acrylic resin. The root portion of tooth were horizontally sectioned into three pieces (apical, middle, and coronal portions). An occlusal view of each section was digitally photographed with a stereomicroscope. The methylene blue-infiltrated surface for each specimen was measured. Dye penetration was estimated as the ratio of the methylene blue-infiltrated surface to the total dentin surface. Results: No significant differences were found among post types. The variables of middle section and 3-stage adhesive produced significant differences in microleakage between the following post pairs: zirconia-glass fiber versus quartz-glass fiber, zirconia-glass fiber versus polyethylene fiber, and quartz-glass fiber versus polyethylene fiber (P<.05). There were significant differences between the apical and coronal sections of each post type, and between apical versus middle sections of quarze-glass fiber and polyethylene fiber posts (P<.05). Conclusion: No significant differences were found among post types. The 3-stage adhesive produced significant differences in microleakage between the following post pairs.