• Title/Summary/Keyword: Peak voltage

Search Result 1,056, Processing Time 0.023 seconds

Development of a 3 kW Grid-tied PV Inverter With GaN HEMT Considering Thermal Considerations (GaN HEMT를 적용한 3kW급 계통연계 태양광 인버터의 방열 설계 및 개발)

  • Han, Seok-Gyu;Noh, Yong-Su;Hyon, Byong-Jo;Park, Joon-Sung;Joo, Dongmyoung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.5
    • /
    • pp.325-333
    • /
    • 2021
  • A 3 kW grid-tied PV inverter with Gallium nitride high-electron mobility transistor (GaN HEMT) for domestic commercialization was developed using boost converter and full-bridge inverter with LCL filter topology. Recently, many GaN HEMTs are manufactured as surface mount packages because of their lower parasitic inductance characteristic than standard TO (transistor outline) packages. A surface mount packaged GaN HEMT releases heat through either top or bottom cooling method. IGOT60R070D1 is selected as a key power semiconductor because it has a top cooling method and fairly low thermal resistances from junction to ambient. Its characteristics allow the design of a 3 kW inverter without forced convection, thereby providing great advantages in terms of easy maintenance and high reliability. 1EDF5673K is selected as a gate driver because its driving current and negative voltage output characteristics are highly optimized for IGOT60R070D1. An LCL filter with passive damping resistor is applied to attenuate the switching frequency harmonics to the grid-tied operation. The designed LCL filter parameters are validated with PSIM simulation. A prototype of 3 kW PV inverter with GaN HEMT is constructed to verify the performance of the power conversion system. It achieved high power density of 614 W/L and peak power efficiency of 99% for the boost converter and inverter.

Development of a Portable Potentiostat with Wireless Communications for Measuring Dissolved Oxygen (용존산소 측정을 위한 무선통신 기반 휴대형 포텐쇼스탯 개발)

  • Lee, Hyun-Seok;Han, Ji-Hoon;Pak, Jungho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1641-1647
    • /
    • 2018
  • In this paper, we describe a portable potentiostat which is capable of cyclic voltammetry(CV) and amperometry for electrochemical dissolved oxygen sensor. In addition, this portable potentiostat can also transmit the measured data wirelessly to android devices such as smart phone, tablet, etc. through Bluetooth. The potentiostat system consists of three parts; a voltage generator circuit which is controlled by Arduino nano and 12-bit DAC(digital to analog converter) to generate necessary electric potential for operating the electrochemical sensor, an oxidation/reduction current measurement circuit, and a Bluetooth module to transmit data wirelessly to an android device. Once measurements are carried out with the android application, the measured data is transmitted to the android device via Bluetooth and displayed using the android app. in real time. In this paper, we report the measured reduction current with a fabricated dissolved oxygen sensor in both saturated-oxygen state and zero-oxygen states. The results of the developed portable potentiostat system are in good agreement with those of the commercial portable potentiostat (${\mu}stat200$, Dropsens inc.). The measured peak reduction currents using the developed potentiostat and the commercial ${\mu}stat200$ potentiostat were $-0.755{\mu}A$ and $-0.724{\mu}A$, respectively. The reduction currents measured at zero-oxygen state were $-0.005{\mu}A$ and $-0.004{\mu}A$. The discrepancy between those two systems seems very small, which implies successful development of a portable and wireless potentionstat.

Effects of 3,3',4,4',5-pentachlorobiphenyl on human Kv1.3 and Kv1.5 channels

  • Kim, Jong-Hui;Hwang, Soobeen;Park, Seo-in;Jo, Su-Hyun
    • International Journal of Oral Biology
    • /
    • v.44 no.3
    • /
    • pp.115-123
    • /
    • 2019
  • Among the environmental chemicals that may be able to disrupt the endocrine systems of animals and humans are polychlorinated biphenyls (PCBs), a chemical class of considerable concern. PCB consists of two six-carbon rings linked by a single carbon bond, and theoretically, 209 congeners can form, depending on the number of chlorines and their location on the biphenyl rings. Furthermore, 3,3',4,4',5-pentachlorobiphenyl (PCB126) exposure also increases nitric oxide production and nuclear factor kappa-light-chain-enhancer of activated B cells binding activity in chondrocytes, thus contributing as an initiator of chondrocyte apoptosis and resulting in thymic atrophy and immunosuppression. This study identified whether cardiac and immune abnormalities from PCB126 were caused by the Kv1.3 and Kv1.5 channels. PCB126 did not affect either the steady-state current or peak current of the Kv1.3 and Kv1.5 channels. However, PCB126 right-shifted the steady-state activation curves of human Kv1.3 channels. These results suggest that PCBs can affect the heart in a way that does not block voltage-dependent potassium channels including Kv1.3 and Kv1.5 directly.

The Performance Analysis of the Parameter Extracting Technique for the Vibration Monitoring System in High Voltage Motor (고압전동기용 진동 감시 시스템의 계수 추출기법 성능 분석)

  • Park, Jung-Cheul;Lee, Dal-Ho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.5
    • /
    • pp.529-536
    • /
    • 2019
  • In this paper, the signals of the sensor for extracting characteristic parameters of the rotor are collected and the performance of the extraction technique is analyzed. To this end, a vibration test league was developed for conducting model tests to analyze the signal characteristics under normal operation. As a result, it is judged that no change in the measured the raw data amplitude will occur in the acceleration sensor with the unbalanced mass measured from the acceleration sensor. Performing FFT showed a significant increase in amplitude of the rotational frequency of 20 Hz as the unbalanced mass increased. The analysis results according to the change in the unequal mass of the speed sensor also showed a significant increase in the 1X Harmonics component, such as the acceleration sensor. There was no change in the amplitude of the acceleration sensor data when the misalignment occurred, and for the Envelope data, the amplitude of 2X (40 Hz) was increased depending on the degree of misalignment. The velocity sensor at change of misalignment also showed similar results to the acceleration sensor, and the peak was reduced at 600 Hz as the load increased in the frequency spectrum.

Semi-active seismic control of a 9-story benchmark building using adaptive neural-fuzzy inference system and fuzzy cooperative coevolution

  • Bozorgvar, Masoud;Zahrai, Seyed Mehdi
    • Smart Structures and Systems
    • /
    • v.23 no.1
    • /
    • pp.1-14
    • /
    • 2019
  • Control algorithms are the most important aspects in successful control of structures against earthquakes. In recent years, intelligent control methods rather than classical control methods have been more considered by researchers, due to some specific capabilities such as handling nonlinear and complex systems, adaptability, and robustness to errors and uncertainties. However, due to lack of learning ability of fuzzy controller, it is used in combination with a genetic algorithm, which in turn suffers from some problems like premature convergence around an incorrect target. Therefore in this research, the introduction and design of the Fuzzy Cooperative Coevolution (Fuzzy CoCo) controller and Adaptive Neural-Fuzzy Inference System (ANFIS) have been innovatively presented for semi-active seismic control. In this research, in order to improve the seismic behavior of structures, a semi-active control of building using Magneto Rheological (MR) damper is proposed to determine input voltage of Magneto Rheological (MR) dampers using ANFIS and Fuzzy CoCo. Genetic Algorithm (GA) is used to optimize the performance of controllers. In this paper, the design of controllers is based on the reduction of the Park-Ang damage index. In order to assess the effectiveness of the designed control system, its function is numerically studied on a 9-story benchmark building, and is compared to those of a Wavelet Neural Network (WNN), fuzzy logic controller optimized by genetic algorithm (GAFLC), Linear Quadratic Gaussian (LQG) and Clipped Optimal Control (COC) systems in terms of seismic performance. The results showed desirable performance of the ANFIS and Fuzzy CoCo controllers in considerably reducing the structure responses under different earthquakes; for instance ANFIS and Fuzzy CoCo controllers showed respectively 38 and 46% reductions in peak inter-story drift ($J_1$) compared to the LQG controller; 30 and 39% reductions in $J_1$ compared to the COC controller and 3 and 16% reductions in $J_1$ compared to the GAFLC controller. When compared to other controllers, one can conclude that Fuzzy CoCo controller performs better.

Evaluation for the Usefulness of Copper Filters according to Mode Change in Digital Radiography System (DR 시스템에서 모드 변화에 따른 구리필터의 유용성 평가)

  • Kim, Jae-Kyeom;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.39-46
    • /
    • 2021
  • This study confirmed the usefulness of the copper filter according to the mode change by comparing and analyzing the energy change according to the application of the copper filter and the change in effective dose and image quality according to the distance to the subject in the DR(Digital Radiography) system. The average energy increased when the copper filter was applied and the reduction rate by 50% of mAs was increased as the thickness of the copper filter increased according to the application of the 10 kVp rule in AEC mode. The effective dose decreased as the thickness increased when the copper filter was applied in AEC(Automatic Exposure Control) mode and manual mode according to the application of the 10 kVp rule, and the decrease rate decreased with increasing 10 kVp increments. As a result of analyzing the dicom images for AEC mode and manual mode with Image J. the PSNR(Peak Signal to Noise Ratio) values were approximate values of less than 30 dB for each mode and for each copper filter thickness. When the copper filter was applied, the average energy increased, so when the 10 kVp rule was applied, the mAs for each mode could be reduced, and the effective dose could also be reduced. However, as the distance and tube voltage increased, the reduction rate of mAs decreased, and the quality of the image was found to decrease when the copper filter was applied, but there was no difference in quality of the image when the copper filter thickness increased.

Effect of poly-Si Thickness and Firing Temperature on Metal Induced Recombination and Contact Resistivity of TOPCon Solar Cells (Poly-Si 두께와 인쇄전극 소성 온도가 TOPCon 태양전지의 금속 재결합과 접촉비저항에 미치는 영향)

  • Lee, Sang Hee;Yang, Hee Jun;Lee, Uk Chul;Lee, Joon Sung;Song, Hee-eun;Kang, Min Gu;Yoon, Jae Ho;Park, Sungeun
    • Current Photovoltaic Research
    • /
    • v.9 no.4
    • /
    • pp.128-132
    • /
    • 2021
  • Advances in screen printing technology have been led to development of high efficiency silicon solar cells. As a post PERx structure, an n-type wafer-based rear side TOPCon structure has been actively researched for further open-circuit voltage (Voc) improvement. In the case of the metal contact of the TOPCon structure, the poly-Si thickness is very important because the passivation of the substrate will be degraded when the metal paste penetrates until substrate. However, the thin poly-Si layer has advantages in terms of current density due to reduction of parasitic absorption. Therefore, poly-Si thickness and firing temperature must be considered to optimize the metal contact of the TOPCon structure. In this paper, we varied poly-Si thickness and firing peak temperature to evaluate metal induced recombination (Jom) and contact resistivity. Jom was evaluated by using PL imaging technique which does not require both side metal contact. As a results, we realized that the SiNx deposition conditions can affect the metal contact of the TOPCon structure.

Fabrication and Property of Excimer Lamp Coated with Green-emitting Zn2SiO4:Mn2+ Phosphor Film (녹색발광 Zn2SiO4:Mn2+ 형광체가 코팅된 엑시머 램프의 제작 및 특성)

  • Kang, Busic;Jung, Hyunjee;Jeong, Yongseok;Son, Semo;Kim, Jongsu
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.4
    • /
    • pp.106-109
    • /
    • 2022
  • The green-emitting Zn2SiO4:Mn2+ phosphor film was evaluated in a xenon excimer lamp. The phosphor film with 2 ㎛ thick was formed of monolithic structure on the inner side of quartz through a long-time annealing process of coated ZnO solution doped with Mn2+ ion and SiO2 of quartz tube. The coated quartz was filled with 100 torr of xenon gas, and simultaneously both sides was melt and sealed. The xenon-field quartz tube was discharge by applying the voltage of 15 kV with a frequency of 26 kHz, and emitted the glow with dominant peak at 172 nm. The vacuum ultraviolet excited the inner-side coated Zn2SiO4:Mn2+ phosphor film, which emitted the pure and strong green light.

Bending characteristics of Prestressed High Strength Concrete (PHC) spun pile measured using distributed optical fibre strain sensor

  • Mohamad, Hisham;Tee, Bun Pin;Chong, Mun Fai;Lee, Siew Cheng;Chaiyasarn, Krisada
    • Smart Structures and Systems
    • /
    • v.29 no.2
    • /
    • pp.267-278
    • /
    • 2022
  • Pre-stressed concrete circular spun piles are widely used in various infrastructure projects around the world and offer an economical deep foundation system with consistent and superior quality compared to cast in-situ and other concrete piles. Conventional methods for measuring the lateral response of piles have been limited to conventional instrumentation, such as electrical based gauges and pressure transducers. The problem with existing technology is that the sensors are not able to assist in recording the lateral stiffness changes of the pile which varies along the length depending on the distribution of the flexural moments and appearance of tensile cracks. This paper describes a full-scale bending test of a 1-m diameter spun pile of 30 m long and instrumented using advanced fibre optic distributed sensor, known as Brillouin Optical Time Domain Analysis (BOTDA). Optical fibre sensors were embedded inside the concrete during the manufacturing stage and attached on the concrete surface in order to measure the pile's full-length flexural behaviour under the prescribed serviceability and ultimate limit state. The relationship between moments-deflections and bending moments-curvatures are examined with respect to the lateral forces. Tensile cracks were measured and compared with the peak strains observed from BOTDA data which corroborated very well. By analysing the moment-curvature response of the pile, the structure can be represented by two bending stiffness parameters, namely the pre-yield (EI) and post-yield (EIcr), where the cracks reduce the stiffness property by 89%. The pile deflection profile can be attained from optical fibre data through closed-form solutions, which generally matched with the displacements recorded by Linear Voltage Displacement Transducers (LVDTs).

A study of communication-based protection coordination for networked distribution system (네트워크 배전계통용 통신기반 보호협조에 관한 연구)

  • Kim, WooHyun;Chae, WooKyu;Hwang, SungWook;Lee, HakJu
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.43-48
    • /
    • 2022
  • Although the distribution system has been structured as complicated as a mesh in the past, the connection points for each line are always kept open, so that it is operated as a radial distribution system (RDS). For RDS, the line utilization rate is determined according to the maximum load on the line, and the utilization rate is usually kept low. In addition, when a fault occurs in the RDS, a power outage of about 3 to 5 minutes occurs until the fault section is separated, and the healthy section is transferred to another line. To improve the disadvantages of the RDS, research on the construction of a networked distribution system (NDS) that linking multiple lines is in progress. Compared to the RDS, the NDS has advantages such as increased facility utilization, load leveling, self-healing, increased capacity connected to distributed generator, and resolution of terminal voltage drop. However, when a fault occurs in the network distribution system, fault current can flow in from all connected lines, and the direction of fault current varies depending on the fault point, so a high-precision fault current direction determination method and high-speed communication are required. Therefore, in this paper, we propose an accurate fault current direction determination method by comparing the peak value polarity of the fault current in the event of a fault, and a communication-based protection coordination method using this method.