Bending characteristics of Prestressed High Strength Concrete (PHC) spun pile measured using distributed optical fibre strain sensor |
Mohamad, Hisham
(Civil & Environmental Engineering Department, Universiti Teknologi PETRONAS)
Tee, Bun Pin (Smart Sensing Technology Sdn. Bhd.) Chong, Mun Fai (Dynamic Pile Testing Sdn. Bhd.) Lee, Siew Cheng (Smart Sensing Technology Sdn. Bhd.) Chaiyasarn, Krisada (Thammasat School of Engineering, Thammasat University Rangsit) |
1 | Lu, Y., Shi, B., Wei, G.Q., Chen, S.E. and Zhang, D. (2012), "Application of a distributed optical fiber sensing technique in monitoring the stress of precast piles", Smart Mater. Struct., 21(11), 115011. https://doi.org/10.1088/0964-1726/21/11/115011 DOI |
2 | Mohamad, H., Soga, K. and Amatya, B. (2014), "Thermal strain sensing of concrete piles using Brillouin optical time domain reflectometry", Geotech. Test. J., 37(2), ASTM, 333-346. https://doi.org/10.1520/GTJ20120176 DOI |
3 | Mohamad, H., Tee, B.P., Chong, M.F. and Ang, K.A. (2017), "Investigation of shaft friction mechanisms of bored piles through distributed optical fibre strain sensing", Proceedings of the 19th International Conference on Soil Mechanics and Geotechnical Engineering, ISMGE, pp. 2829-2832. |
4 | Mohamad, H., Tee, B.P., Chong, M.F., Ang, K.A., Rashid, A.S.A. and Abdullah, R.A. (2019), "Instrumented laterally loaded pile test using distributed fibre optic sensor", Geotech. Eng., 50(2), 36-42. |
5 | Ni, P., Mangalathu, S., Mei, G. and Zhao, Y. (2017), "Compressive and flexural behaviour of reinforced concrete permeable piles", Eng. Struct., 147, 316-327. https://doi.org/10.1016/j.engstruct.2017.06.007 DOI |
6 | Avent, R.R. and Mukai, D.J. (1998), "Investigation of Cracks in Cylindrical Spun-Cast Concrete Piles in a Marine Environment", Louisiana Transportation Research Center, LA-98/320. |
7 | Joint ACI-ASCE Committee 423 (2016), ACI PRC-423.10-16 Guide to Estimating Prestress Losses, American Concrete Institute, Farmington Hills, MI, USA. |
8 | Vitharana, N. (1997), "Rational prediction of lateral behaviour of concrete piles incorporating pile (concrete) non-linearity", Proceedings of the 14th International Conference on Soil Mechanics and Foundation Engineering, Recent developments in foundation techniques, pp. 915-920. |
9 | Abu-Farsakh, M.Y., Haque, M.N. and Tsai, C. (2017), "A full-scale field study for performance evaluation of axially loaded large-diameter cylinder piles with pipe piles and PSC piles", Acta Geotech., 12(4), 753-772. https://doi.org/10.1007/s11440-016-0498-9 DOI |
10 | Aso, T., Miura, F., Inoue, T. and Yamamoto, M. (2004), "Non-linear bending characteristics of PHC piles under varying axial load", Proceedings of the 13th World Conference on Earthquake Engineering, WCEE, in CD-ROM, 1-9. |
11 | Bao, Y., Tang, F., Chen, Y., Meng, W., Huang, Y. and Chen, G. (2016), "Concrete pavement monitoring with PPP-BOTDA distributed strain and crack sensors", Smart Struct. Syst., Int. J., 18(3), 405-423. http://doi.org/10.12989/sss.2016.18.3.405 DOI |
12 | Chow, C.C. and Tan, Y.C. (2010), "Performance of jack-in pile foundation in weathered granite", Proceedings of the 17th SEA Geotechnical Conference, Taipei, Taiwan, pp. 1-4. |
13 | Feng, X., Wu, W., Li, X., Zhang, X. and Zhou, J. (2015), "Experimental investigations on detecting lateral buckling for subsea pipelines with distributed fiber optic sensors", Smart Struct. Syst., Int. J., 15(2), 245-258. http://doi.org/10.12989/sss.2015.15.2.245 DOI |
14 | Goldfeld, Y. and Klar, A. (2013), "Damage identification in reinforced concrete beams using spatially distributed strain measurements", J. Struct. Eng., 139(12), 04013013. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000795 DOI |
15 | Rausche, F. and Webster, S. (2007), "Behavior of cylinder piles during pile installation", In: Contemporary Issues in Deep Foundations, (in W. Camp, R. Castelli, D.F. Laefer and S. Paikowsky eds.), American Society of Civil Engineers. |
16 | Liu, H.B., Zhang, Q. and Zhang, B.H. (2017), "Structural health monitoring of a newly built high-piled wharf in a harbor with fiber Bragg grating sensor technology: design and deployment", Smart Struct. Syst., Int. J., 20(2), 163-173. https://doi.org/10.12989/sss.2017.20.2.163 DOI |
17 | Mohamad, H., Tee, B.P., Ang, K.A. and Chong, M.F. (2016), "Characterizing anomalies in distributed strain measurements of cast-in-situ bored piles", Jurnal Teknologi, 78(8-5), 75-82. https://doi.org/10.11113/jt.v78.9626 DOI |
18 | MS1314: Part 2 (2004), Precast Concrete Piles: Part 2: Method for Determination of Bending Strength of Precast Concrete Piles (Bend Test), Malaysian Standard, Department of Standards Malaysia. |
19 | Whiting, W.A. (1952), "Reinforced concrete pipe", U.S. Patent, No. 2,602,469, 8 Jul. 1952. |
20 | Volgyi, I., Farkas, G. and Nehme, S.G. (2010), "Concrete strength tendency in the wall of cylindrical spun-cast concrete elements", Period Polytech.-Civil, 54(1), 23-30. http://dx.doi.org/10.3311/pp.ci.2010-1.03 DOI |
21 | Abendroth, R.E., Greimann, L.F. and LaViolett, M.D. (2007), "An Integral Abutment Bridge with Precast Concrete Piles", IHRB Project TR-438, Iowa Highway Research Board & Iowa Department of Transportation, USA. |
22 | Zou, L., Bao, X., Yang, S., Chen, L. and Ravet, F. (2006), "Effect of Brillouin slow light on distributed Brillouin fiber sensors", Opt. Lett., 31(18), 2698-2700. http://dx.doi.org/10.1364/OL.31.002698 DOI |
23 | Kim, S.T., Park, Y., Park, S.Y., Cho, K. and Cho, J.R. (2015), "A sensor-type PC strand with an embedded FBG sensor for monitoring prestress forces", Sensors, 15(1), 1060-1070. https://doi.org/10.3390/s150101060 DOI |
24 | Liew, S.S., Lee, S.T. and Koo, K.S. (2010), "Failure Investigation of Piled Reinforcement Soil Wall & Excessive Movements of Piled Embankment at Soft Ground, Malaysia", Proceedings of the 17th Southeast Asian Geotechnical Conference, Taipei, Taiwan, 3P-191. |
25 | Pelecanos, L., Soga, K., Elshafie, M.Z.E.B., Battista, N., Kechavarzi, C., Gue, C.Y., Ouyang, Y. and Seo, H.J. (2018), "Distributed fiber optic sensing of axially loaded bored piles", J. Geotech. Geoenviron. Eng., 144(3), 04017122. https://doi.org/10.1061/(ASCE)GT.1943-5606.0001843 DOI |
26 | Hartman, J.J., Castelli, R.J. and Malhotra, S. (2007), "Design and Installation of Concrete Cylinder Piles", In: Contemporary Issues in Deep Foundations, (in W. Camp, R. Castelli, D.F. Laefer and S. Paikowsky eds.), American Society of Civil Engineers. |
27 | Hong, W.P., Kim, J.H. and Hong, S. (2019), "Role of piles in mitigating the movement of pipes in soft grounds during embankment loading", Mar. Georesources Geotechnol., 37(9), 1019-1031. https://doi.org/10.1080/1064119X.2018.1523973 DOI |
28 | Huang, X., Yang, M., Feng, L., Gu, H., Su, H., Cui, X. and Cao, W. (2017), "Crack detection study for hydraulic concrete using PPP-BOTDA", Smart Struct. Syst., Int. J., 20(1), 75-83. https://doi.org/10.12989/sss.2017.20.1.075 DOI |
29 | Joen, P.H. and Park, R. (1990), "Flexural strength and ductility analysis of spirally reinforced prestressed concrete piles", PCI J., 35(4), 64-83. https://doi.org/10.15554/pcij.07011990.54.83 DOI |
30 | Kesavan, K., Ravisankar, K., Parivallal, S. and Sreeshylam, P. (2005), "Applications of fiber optic sensors for structural health monitoring", Smart Struct. Syst., Int. J., 1(4), 355-368. https://doi.org/10.12989/sss.2005.1.4.355 DOI |