• Title/Summary/Keyword: Peak pressure

Search Result 1,458, Processing Time 0.034 seconds

Properties of High Power Flip Chip LED Package with Bonding Materials (접합 소재에 따른 고출력 플립칩 LED 패키지 특성 연구)

  • Lee, Tae-Young;Kim, Mi-Song;Ko, Eun-Soo;Choi, Jong-Hyun;Jang, Myoung-Gi;Kim, Mok-Soon;Yoo, Sehoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Flip chip bonded LED packages possess lower thermal resistance than wire bonded LED packages because of short thermal path. In this study, thermal and bonding properties of flip chip bonded high brightness LED were evaluated for Au-Sn thermo-compression bonded LEDs and Sn-Ag-Cu reflow bonded LEDs. For the Au-Sn thermo-compression bonding, bonding pressure and bonding temperature were 50 N and 300oC, respectively. For the SAC solder reflow bonding, peak temperature was $255^{\circ}C$ for 30 sec. The shear strength of the Au-Sn thermo-compression joint was $3508.5gf/mm^2$ and that of the SAC reflow joint was 5798.5 gf/mm. After the shear test, the fracture occurred at the isolation layer in the LED chip for both Au-Sn and SAC joints. Thermal resistance of Au-Sn sample was lower than that of SAC bonded sample due to the void formation in the SAC solder.

Soft Plasma Flash X-ray Generator Utilizing a Vacuum Discharge Capillary

  • Sato, Eiichi;Hayasi, Yasuomi;Usuki, Tatsumi;Sato, Koetsu;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.400-403
    • /
    • 2002
  • The fundamental experiments for measuring soft x-ray characteristics from the vacuum capillary are described. These experiments were primarily performed in order to generate line spectra such as x-ray lasers. The generator consists of a high-voltage power supply, a polarity-inversion ignitron pulse generator, a turbo-molecular pump, and a radiation tube with a capillary. A high-voltage condenser of 200 nF in the pulse generator is charged up to 20 kV by the power supply, and the electric charges in the condenser are discharged to the capillary in the tube after closing the ignitron. During the discharge, weakly ionized plasma forms on the inner and outer sides of a capillary. In the present work, the pump evacuates air from the tube with a pressure of about 1 mPa, and a demountable capillary was developed in order to measure x-ray spectra according to changes in the capillary length. In this capillary, the anode (target) and cathode elements can be changed corresponding to the objectives. The capillary diameter is 2.0 mm, and the length is adjusted from 1 to 50 mm. When a capillary with aluminum anode and cathode electrodes was employed, both the cathode voltage and the discharge current almost displayed damped oscillations. The peak values of the voltage and current increased when the charging voltage was increased, and their maximum values were -10.8 kV and 4.7 kA, respectively. The x-ray durations observed by a 1.6 ${\mu}$m aluminum filter were less than 30 ${\mu}$s, and we detected the aluminum characteristic x-ray intensity using a 6.8 ${\mu}$m aluminum filter. In the spectrum measurement, two sets of aluminum and titanium electrodes were employed, and we observed multi-line spectra. The line photon energies seldom varied according to changes in the condenser charging voltage and to changes in the electrode element. In the case where the titanium electrode was employed, the line number decreased with corresponding decreases in the capillary length. Compared with incoherent visible light, these rays from the capillary were diffracted and diffused greatly after passing through two slits.

  • PDF

The Risk Factors of Recurrent Ischemic Stroke (허혈성 뇌졸중의 재발과 연관된 위험인자)

  • Jung, Cheol;Kim, Wook-Nyneon;Kim, Min-Jeung;Choi, Soek-Mum;Eur, Kyung-Yoon;Park, Mee-Young;Hah, Jeng-Sang;Byun, Yeung-Ju
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.2
    • /
    • pp.423-431
    • /
    • 1993
  • To eveluate the risk factors which are related to recurrence of ischemic stroke, we selected subjects who were admitted to YNUH due to recurrent stroke and compared their risk factors with non-recurred group who suffered from single ischemic stroke. In the subjects, 55 of them are men and 22 were women and in the non-recurred groups, 84 of them were men and 40 were women, Subject's age ranged from 29 to 85 years(Mean 62, 5years), and non-recurred group's age ranged from 27 to 90 years(Mean 60, 7years), Peak incidence of ischemic stroke is in the 7th decade in both groups. Age and sex are not, statistically significant for recurrence of ischemic stroke. The patient's history of diabetes mellitus, myocardial infarction, atrial fibrillation, transient attack and type or site of ischemic stroke had no significant effect statistically on the recurrent ischemic stroke. However, when the patient had previous history of hypertension or systolic blood pressure more than 160mmHg and diastolic more than 95mmHg, there was substantial difference(P<0.05) between the two group in the recurrence of ischemic stroke. According to the above results, hypertension is most likely significant risk factor of the recurrence of ischemic stroke within 2years after initial one. Therefore, adequate treatment of the hypertension is important for the prevention of ischemic stroke. Further study is required for searching other risk factors.

  • PDF

A Study on Standard Ocean Lighted Buoy Type System for Real-time Ocean Meteorological Observation (실시간 해양관측을 위한 표준형 등부표용 시스템 연구)

  • Park, Sanghyun;Park, Yongpal;Bae, Dongjin;Kim, Jinsul;Park, Jongsu
    • Journal of Digital Contents Society
    • /
    • v.19 no.9
    • /
    • pp.1739-1749
    • /
    • 2018
  • We propose a marine observation system using existing light buoys to observe various marine information of marine locations. Our proposed ocean observation system is composed of the existing standard light buoy type and can be easily connected to the light buoy. The proposed marine observation system measures the mean wave height, maximum wave height, mean wave height and water temperature measured in the ocean. Besides, it can measure the air pressure, temperature, wind speed and wind speed in real time. In order to measure important peaks in marine observations, 2200 peak data are collected for 10 minutes, and the collected data are subjected to spectral analysis to extract significant wave and wave period data. The developed system removes the noise by using the filter because the marine observation system attaches to the light buoy. We compare and analyze the measurement data of the existing proven floating marine observation system and the standard equivalent system developed. Also, it is proved that the data of the standard type backbone ocean observation system developed through the comparative experiment is similar to that of the existing ocean observation system.

Study on the improvement of microdialysis method for measuring brain amino acids in systemic morphine treated rats (Morphine을 전신투여한 랫드의 뇌에서 분비되는 amino acid 성 신경전달물질 측정을 위한 미세투석법의 개선에 관한 연구)

  • Lee, Jang-hern;Beitz, Alvin J
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.3
    • /
    • pp.535-543
    • /
    • 1998
  • In the present study, we designed and constructed new microdialysis probe in order to improve the efficacy and accuracy of microdialysis method. In addition, extracellular concentrations of GABA, glutamate, aspartate and glycine were monitored with new designed probe in the lateral portion of the ventrocaudal periaqueductal gray using unanesthetized and unrestrained rats. Furthermore, the effect of opiates on release of these amino acids, especially GABA, was analyzed by measuring their concentration in PAG dialysates following veratridine administration in the presence of systemic morphine. The results were summerized as follow : 1. The damaging rates of 1.0mm or 1.5mm window probe were 12.5% or 42.8%, respectively. In the group using 1.5mm window probe, the damaging area was extended into mesencephalic aqueduct because of microdialyzing pressure. 2. Because of the unique design of our probes with an opening facing one side, dialysis occurs in a hemisphere($600{\mu}m$ in mediolateral direction and $100{\mu}m$ in opposite side of the dialysis probe) around the opening rather than in a spherical shaped configuration which is typical of most commercially available probe designs. 3. Glutamate, taurine and glycine were present in the highest concentration in the dialysate sample obtained before treatment with veratridine, whereas, aspartate and GABA were present in the lowest concentration. 4. The concentration of all 5 amino acids increased significantly following $75{\mu}m$ veratridine perfusion into lateral ventrocaudal PAG. 5. There was no significant difference between basal and peak amino acid concentrations according to window sizes. 6. Morphine had no effect on baseline concentrations of amino acids in dialysates obtained from the lateral PAG as compared to saline treated controls. However, following veratridine treatment, morphine selectively affected GABA release in the lateral ventrocaudal PAG as compared to saline treated controls. These results suggest that GABAergic interneurons in the PAG are inhibited by opioids. Therefore, endogenous enkephalins or endorphins may directly inhibit intrinsic GABAergic intemeurons and block their tonic inhibition of PAG-NMR projection neurons. Moreover, new designed probes demonstrate improved efficiency and accuracy in collecting samples as compared to commercial types of microdialysis probes.

  • PDF

Endothelin-1 Levels in Patients with Heart Disease Associated with Pulmonary Hypertension ; Potential role of Endothelin-1 in genesis of pulmonary artery vasospasm (개심술 환자에서 술전및 술후의 폐동맥 고혈압및 혈역학적 변수들과 ET-1치와의 관계에 대한 연구)

  • 박형주
    • Journal of Chest Surgery
    • /
    • v.25 no.6
    • /
    • pp.650-660
    • /
    • 1992
  • To elucidate a potential contribution of endotheline-1[ET-1] to the genesis of pulmonary hypertension and postoperative pulmonary hypertensive crisis in the patients with heart disease, we measured plasma levels of the ET-1 during perioperative period of open heart surgery. In addition, we examined changes of ET-1 during perioperative period and correlations between ET-1 levels and hemodynamic variables. 12 patients including 5 acquired heart disease and 7 congenital heart disease patients were selected randomly as a study group, Group A and B, respectively. 6 patients proved not having heart or hemodynamic problem were selected as a control, Group C. 110 blood samples from pulmonary artery[ET-P] and radial artery[ET-S] were taken and assayed by Sep-pak extraction and RIA. ET-1 levels of Group A were ET-P, 3.94$\pm$5.31pg /ml, ET-S, 3.10$\pm$2.90pg/ml[p>0.05], Group B were ET-P, 1.63$\pm$0.62pg/ml, ET-S, 1.99$\pm$2.45pg/ml[p>0.05], Group C were ET-P, 1.97$\pm$2.02pg/ml, ET-S, 1.72$\pm$0.77pg/ml[p>0.05]. There were no statistically significant differences of ET-1 levels among the Group A, B, C[p>0.05]. There was no correlation between pulmonary artery pressure[PAP] and ET-1 level[p>0.05], and ET-1 levels were not increased even in the cases of pulmonary hypertensive criwis or low cardiac output syndrome, whereas significant correlation between ET-S and pulmonary vascular res-istance[Rp] [r=0.36, p<0.05], and negative correlation between ET-S and OS saturation of pulmonary artery[OS-P][r= -0.49, p<0.01] were identified. Another significant finding was peak increase of ET-1 levels in the postoperative period 1 hour[p<0.05] and then gra-dualy decrease through the postoperative period. In conclusion, ET-1 has no correlation with PAP, whereas correlation with Rp, and inverse correlation with OS-P. It is suggested that ET-1 is neither the direct causative substance of pulmonary hypertension nor pulmonary vasospasm but there must be increased production of ET-1 in chronic pulmonary hypertensive state. Counter-regulatory mechanism to ET-1 is speculated during the pulmonary vasospasm.

  • PDF

Effects of Storage Conditions on Rancidity of Perilla and Sesame Seed Oils (저장조건(貯藏條件)이 들깨유(油) 및 참깨유(油)의 산패도(酸敗度)에 미치는 영향(影響))

  • Kim, Hye-Kyung;Lee, Yang-Cha;Lee, Ki-Yull
    • Journal of Nutrition and Health
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 1979
  • It is a general trend everywhere that the uses of vegetable oils are increasing due to the fact that they are effective in curing and preventing symptoms of high blood pressure and various heart failure conditions. At the same time the concept that oxidative rancidity is caused by the oxidation of unsaturated fatty acid moieties whose subsequent decomposition gives rise to various undesirable, sometimes toxic compounds is now well accepted. Linolenic acid (C, 18:3) is one of highly unsaturated and readily oxidizable fatty acid. The content of this essential polyunsaturated fatty acid in perilla seed oil (PSO) was found to be as high as 48% while only 1.5% in sesame seed oil (SSO). In this experiment the oxidative stability of PSO was compared with that of SSO. The experimental test group were as follows: A) Stored at different temperatures, namely $4^{\circ}C,\;30^{\circ}C,$ and $60^{\circ}C,$ B) Stored at room temperature $(20{\pm}5^{\circ}C)$ ; a. protected from sunlight and air, b. exposed to air without sunlight c. exposed to sunlight but protected front air, d. completely exposed to both air and sunlight. The following results were obtained; 1) It was found to be most stable against oxidation to store both PSO and SSO under the low temperature $(4^{\circ}C)$ condition. According to P.V. measurements it was found to be safe to keep both oils up to $30^{\circ}C$ for at least 8 weeks. When exposed to air, sunlight and high temperature $(60^{\circ}C)$, P.V. of PSO reached there peak values, which were much higher than those of SSO. This explains much of its instability as compared to SSO against oxidation. 2) The effect of high temperature $(60^{\circ}C)$ on A.V. was found to be more striking than those of all the other storage conditions. The condition of refrigeration was most effective in keeping A.V. low for both oils as was the case in P.V. 3) For both oils, I.V. decreased throughout the experimental period (8 weeks). The range of decrement was larger for PSO than SSO. 4) There was no significant change in the compositions of fatty acids of SSO caused by various experimental storage conditions. But for PSO the compositions of stearic, oleic and linoleic acid were decreased, whereas linolenic acid was increased proportionally.

  • PDF

Effect of fuel injection timing on the combustion and NOx emission characteristics in a single cylinder diesel engine applied with diesel fuel for naval vessel and biodiesel (함정용 디젤 연료와 바이오디젤 연료를 적용한 단기통 디젤엔진에서 연료분사시기가 연소 및 질소산화물 배출특성에 미치는 영향)

  • Lee, Hyungmin
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.681-687
    • /
    • 2014
  • The objective of this work presented here was focused on analysis of in-cylinder combustion characteristic, engine performance, and nitrogen oxides emission characteristic from marine gas oil for propulsion diesel engine of naval vessels and biodiesel with fuel injection timing in a single cylinder diesel engine. In addition, combustion process was analyzed with a high speed camera of marine gas oil and biodiesel fuel. Retarding the fuel injection timing from $BTDC25^{\circ}CA$ to $BTDC5^{\circ}CA$, in cylinder peak combustion pressure was gradually decreased, however, engine torque showed a tendency to increase. The highest nitrogen oxides level was measured at $BTDC15^{\circ}CA$, they were reduced at retarded and advanced condition on the basis of $BTDC15^{\circ}CA$. Comparing with combustion process of marine gas oil and biodiesel fuel at $BTDC5^{\circ}CA$, self-ignition timing of biodiesel fuel included oxygen content was faster than marine gas oil, however, a cautious observation indicates a slightly higher flame intensity for marin gas oil than biodiesel as a diffusion flame is developing.

Structural and optical properties of Si nanowires grown by Au-Si island-catalyzed chemical vapor deposition (Au-Si 나노점을 촉매로 성장한 Si 나노선의 구조 및 광학적 특성 연구)

  • Lee, Y.H.;Kwak, D.W.;Yang, W.C.;Cho, H.Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.1
    • /
    • pp.51-57
    • /
    • 2008
  • we have demonstrated structural evolution and optical properties of Si-nanowires (NWs) synthesized on Si (111) substrates with nanoscale Au-Si islands by rapid thermal chemical vapor deposition (RTCVD). The Au-Si nano-islands (10-50nm in diameter) were employed as a liquid-droplet catalysis to grow Si-NWs via vapor-liquid-solid mechanism. The Si-NWs were grown by a mixture gas of SiH4 and H2 at a pressure of 1.0 Torr and temperatures of $500{\sim}600^{\circ}C$. Scanning electron microscopy measurements showed that the Si-NWs are uniformly sized and vertically well-aligned along <111> direction on Si (111) surfaces. The resulting NWs are ${\sim}60nm$ in average diameter and ${\sim}5um$ in average length. High resolution transmission microscopy measurements indicated that the NWs are single crystals covered with amorphous SiOx layers of ${\sim}3nm$ thickness. In addition, the optical properties of the NWs were investigated by micro-Raman spectroscopy. The downshift and asymmetric broadening of the Si main optical phonon peak were observed in Raman spectra of Si-NWs, which indicates a minute stress effects on Raman spectra due to a slight lattice distortion led by lattice expansion of Si-NW structures.

Tc-99m-DAPA Pulmonary Clearance in Normals (정상성인에서의 Tc-99m-DTPA 폐제거율)

  • Chung, Soo-Kyo;Yang, Woo-Jin;Sohn, Hyung-Sun;Shinn, Kyung-Sub;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.338-342
    • /
    • 1994
  • Pulmonary clearance of Tc-99m-DTPA(PCD) has been used for the measurement of polmonary epithelial permeability. It has been reported to be increased not only in variety of polmonary diseases including ARDS, interstitial fibrosis, and smokers, but also in normal subjects on positive end expiratory pressure respirator, or after exercise. It was also noted that decrease of pulmonary blood flow due to pulmonary arterial obstruction results in delayed PCD. Normal range of PCD varies with institutes. We prospectively measured PCD in 17 normals (5 males and 12 females) consisted of staffs and trainees in the department of radiology of Kangnam St. Mary's hospital using original Bark Nebulizer (India). Age ranged from 32 to 43 years. 370 MBq of Tc-99m-DTPA was inhaled in supine position and supine posterior images were subsequently obtained with 1 min/frame, $64{\times}64$ matrix and word mode for 30min. Regions of interest were set on each lung, whole lungs, and upper, middle and lower thirds of right lung, respectively. Best fit regression curve was obtained by least square method from initial 7min after peak activity on each curve and time for half clearance of maximum activity (t1/2) was calculated. Mean t1/2 was $51{\pm}11.2min$ for whole lung. There was no significant difference between t1/ 2 of right and left lungs. Initial uptake was higher in the lower third and t1/2 was shorter in the lower third than in the upper third(P<0.05). We reviewed several reports on PCD and compared our data with the others. In this study, faster clearance in the lower third may be due to the position imaged with or the environment the subjects belong to, and further investigation is under way.

  • PDF