• 제목/요약/키워드: Peak power density

검색결과 201건 처리시간 0.027초

저밀도 폴리에틸렌에서 부시형 전기트리에 수반되는 부분방전 펄스의 특성 (Properties of PD Pulses Accompanying with Bush-type Tree in LDPE)

  • 강성화;박영국;정수현;이광우;임기조
    • 한국전기전자재료학회논문지
    • /
    • 제11권12호
    • /
    • pp.1055-1059
    • /
    • 1998
  • The correlation between the propagation of electrical tree and distributions of partial discharge(PD) pulses accompanying with electrical tree of bush type in low density polyethylene were discussed. We measured the growth of electrical tree by using optical microscope and PD data simultaneously. The PD data detected and analyzed were PD magnitude, repetition rate, average discharge power, average phase angle, and $\psi$-q-n distribution pattern. The average discharge power and repetition rate of PD had good linear relation with area of tree. Repetition rate and peak discharge magnitude and width of discharge phase angle increased with the tree.

  • PDF

PAPR reduction of OFDM systems using H-SLM method with a multiplierless IFFT/FFT technique

  • Sivadas, Namitha A.
    • ETRI Journal
    • /
    • 제44권3호
    • /
    • pp.379-388
    • /
    • 2022
  • This study proposes a novel low-complexity algorithm for computing inverse fast Fourier transform (IFFT)/fast Fourier transform (FFT) operations in binary phase shift keying-modulated orthogonal frequency division multiplexing (OFDM) communication systems without requiring any twiddle factor multiplications. The peak-to-average power ratio (PAPR) reduction capacity of an efficient PAPR reduction technique, that is, H-SLM method, is evaluated using the proposed IFFT algorithm without any complex multiplications, and the impact of oversampling factor for the accurate calculation of PAPR is analyzed. The power spectral density of an OFDM signal generated using the proposed multiplierless IFFT algorithm is also examined. Moreover, the bit-error-rate performance of the H-SLM technique with the proposed IFFT/FFT algorithm is compared with the classical methods. Simulation results show that the proposed IFFT/FFT algorithm used in the H-SLM method requires no complex multiplications, thereby minimizing power consumption as well as the area of IFFT/FFT processors used in OFDM communication systems.

Effect of Kinetic Parameters on Simultaneous Ramp Reactivity Insertion Plus Beam Tube Flooding Accident in a Typical Low Enriched U3Si2-Al Fuel-Based Material Testing Reactor-Type Research Reactor

  • Nasir, Rubina;Mirza, Sikander M.;Mirza, Nasir M.
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.700-709
    • /
    • 2017
  • This work looks at the effect of changes in kinetic parameters on simultaneous reactivity insertions and beam tube flooding in a typical material testing reactor-type research reactor with low enriched high density ($U_3Si_2-Al$) fuel. Using a modified PARET code, various ramp reactivity insertions (from $0.1/0.5 s to $1.3/0.5 s) plus beam tube flooding ($0.5/0.25 s) accidents under uncontrolled conditions were analyzed to find their effects on peak power, net reactivity, and temperature. Then, the effects of changes in kinetic parameters including the Doppler coefficient, prompt neutron lifetime, and delayed neutron fractions on simultaneous reactivity insertion and beam tube flooding accidents were analyzed. Results show that the power peak values are significantly sensitive to the Doppler coefficient of the system in coupled accidents. The material testing reactor-type system under such a coupled accident is not very sensitive to changes in the prompt neutron life time; the core under such a coupled transient is not very sensitive to changes in the effective delayed neutron fraction.

Non-gaseous Plasma Immersion Ion Implantation and Its Applications

  • Han, Seung-Hee;Kim, En-Kyeom;Park, Won-Woong;Moon, Sun-Woo;Kim, Kyung-Hun;Kim, Sung-Min
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.151-151
    • /
    • 2012
  • A new plasma process, i.e., the combination of PIII&D and HIPIMS, was developed to implant non-gaseous ions into materials surface. HIPIMS is a special mode of operation of pulsed-DC magnetron sputtering, in which high pulsed DC power exceeding ~1 kW/$cm^2$ of its peak power density is applied to the magnetron sputtering target while the average power density remains manageable to the cooling capacity of the equipment by using a very small duty ratio of operation. Due to the high peak power density applied to the sputtering target, a large fraction of sputtered atoms is ionized. If the negative high voltage pulse applied to the sample stage in PIII&D system is synchronized with the pulsed plasma of sputtered target material by HIPIMS operation, the implantation of non-gaseous ions can be successfully accomplished. The new process has great advantage that thin film deposition and non-gaseous ion implantation along with in-situ film modification can be achieved in a single plasma chamber. Even broader application areas of PIII&D technology are believed to be envisaged by this newly developed process. In one application of non-gaseous plasma immersion ion implantation, Ge ions were implanted into SiO2 thin film at 60 keV to form Ge quantum dots embedded in SiO2 dielectric material. The crystalline Ge quantum dots were shown to be 5~10 nm in size and well dispersed in SiO2 matrix. In another application, Ag ions were implanted into SS-304 substrate to endow the anti-microbial property of the surface. Yet another bio-application was Mg ion implantation into Ti to improve its osteointegration property for bone implants. Catalyst is another promising application field of nongaseous plasma immersion ion implantation because ion implantation results in atomically dispersed catalytic agents with high surface to volume ratio. Pt ions were implanted into the surface of Al2O3 catalytic supporter and its H2 generation property was measured for DME reforming catalyst. In this talk, a newly developed, non-gaseous plasma immersion ion implantation technique and its applications would be shown and discussed.

  • PDF

Compact Wireless IPT System Using a Modified Voltage-fed Multi-resonant Class EF2 Inverter

  • Uddin, Mohammad Kamar;Mekhilef, Saad;Ramasamy, Gobbi
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.277-288
    • /
    • 2018
  • Wireless inductive power transfer (IPT) technology is used in many applications today. A compact and high-frequency primary side inverter is one of the most important parts of a WPT system. In this study, a modified class EF-type voltage-fed multi-resonant inverter has been proposed for WPT application at a frequency range of 85-100 kHz. Instead of an infinite input choke inductor, a resonant inductor is used to reduce loss and power density. The peak voltage stress across the MOSFET has been reduced to almost 60% from a class-E inverter using a passive clamping circuit. A simple yet effective design procedure has been presented to calculate the various component values of the proposed inverter. The overall system is simulated using MATLAB/SimPowerSystem to verify the theoretical concepts. A 500-W prototype was built and tested to validate the simulated results. The inverter exhibited 90% efficiency at nearly perfect alignment condition, and efficiency reduced gradually with the misalignment of WPT coils. The proposed inverter maintains zero-voltage switching (ZVS) during considerable load changes and possesses all the inherent advantages of class E-type inverters.

감염 조절용 차단막의 두께가 광중합기의 중합광에 미치는 영향 (Effect of infection control barrier thickness on light curing units)

  • 장훈상;이석련;홍성옥;류현욱;송창규;민경산
    • Restorative Dentistry and Endodontics
    • /
    • 제35권5호
    • /
    • pp.368-373
    • /
    • 2010
  • 연구목적: 본 연구는 감염 조절용 차단막을 여러 겹으로 사용했을 때 광중합기의 광강도와 파장, light diffusion 등에 미치는 영향에 대해 조사하였다. 연구 재료 및 방법: 감염 조절용 차단막은 투명 랩 (크린랩)을 사용하였고 광중합기는 할로겐 광중합기 (Optilux 360)와 LED 광중합기 (Elipar FreeLight 2)를 사용하였다. 차단막을 1겹, 2겹, 4겹, 8겹으로 광중합기의 광섬유말단을 감싸고 휴대용 광강도 측정기 (Cure Rite)로 광중합기의 광강도를 측정하였다. 광중합기를 주문제작한 optical breadboard에 고정시킨 후 휴대용 spectroradiometer (CS-1000)를 이용하여 광중합기의 파장을 측정하였고, DSLR (Nikon D70s)을 이용하여 광중합기의 light diffusion을 사진 촬영하였다. 결과: 광강도 측정 결과는 차단막의 두께가 증가할수록 광강도가 유의하게 감소하였으나 할로겐 광중합기에서 1겹과 2겹 사이에는 유의차가 없었으며, 4겹 이상의 차단막을 투과할 때 광강도가 더 많이 감소하였다. 여러 겹의 차단막을 투과한 광중합기의 전체적인 파장 형태와 peak wavelength의 변화는 관찰되지 않았다. Light diffusion 사진 촬영 시, LED 광중합기에서는 차단막의 두께가 미치는 영향이 없었으나 할로겐 광중합기에서는 차단막을 4겹 사용했을 때부터 중합광이 조사되는 각도가 감소하기 시작하여 8겹 사용했을 때 통계적으로 유의하게 감소하는 것을 볼 수 있었다 (p < 0.05). 결론: 광중합형 복합레진을 광중합할 경우 감염 조절용 차단막이 찢어지는 경우를 대비하여 1겹으로 사용하기 보다는 2겹으로 사용하는 것이 환자간의 교차감염을 예방하는데 유리할 것으로 사료된다.

BLDC 전동기의 정현적 공극 자속밀도 구현에 의한 코깅 토크 저감 (Reduction of Cogging Torque of BLDC Motor by Sinusoidal Air-Gap Flux Density Distribution)

  • 김사무엘;정승호;류세현;권병일
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.57-65
    • /
    • 2007
  • Along with the development of power electronics and magnetic materials, permanent magnet (PM) brushless direct current (BLDC) motors are now widely used in many fields of modern industry BLDC motors have many advantages such as high efficiency, large peak torque, easy control of speed, and reliable working characteristics. However, Compared with the other electric motors without a PM, BLDC motors with a PM have inherent cogging torque. It is often a principle source of vibration, noise and difficulty of control in BLDC motors. Cogging torque which is produced by the interaction of the rotor magnetic flux and angular variation in the stator magnetic reluctance can be reduced by sinusoidal air-gap flux density waveform due to reduction of variation of magnetic reluctance. Therefore, this paper will present a design method of magnetizing system for reduction of cogging torque and low manufacturing cost of BLDC motor with isotropic bonded neodynium-iron-boron (Nd-Fe-B) magnets in ring type by sinusoidal air-gap flux density distribution. An analytical technique of magnetization makes use of two-dimensional finite element method (2-D FEM) and Preisach model that expresses the hysteresis phenomenon of magnetic materials in order for accurate calculation. In addition, For optimum design of magnetizing fixture, Factorial design which is one of the design of experiments (DOE) is used.

게이트 드라이버가 집적된 GaN 모듈을 이용한 48V-12V 컨버터의 설계 및 효율 분석 (Design and Efficiency Analysis 48V-12V Converter using Gate Driver Integrated GaN Module)

  • 김종완;최중묵;유세프알라브;제이슨라이
    • 전력전자학회논문지
    • /
    • 제24권3호
    • /
    • pp.201-206
    • /
    • 2019
  • This study presents the design and experimental result of a GaN-based DC-DC converter with an integrated gate driver. The GaN device is attractive to power electronic applications due to its superior device performance. However, the switching loss of a GaN-based power converter is susceptible to the common source inductance, and converter efficiency is severely degraded with a large loop inductance. The objective of this study is to achieve high-efficiency power conversion and the highest power density using a multiphase integrated half-bridge GaN solution with minimized loop inductance. Before designing the converter, several GaN and Si devices were compared and loss analysis was conducted. Moreover, the impact of common source inductance from layout parasitic inductance was carefully investigated. Experimental test was conducted in buck mode operation at 48 -12 V, and results showed a peak efficiency of 97.8%.

Probability Density Function of Samples' Amplitude of ASSS OFDM Signal

  • Wang, Lei;Yoon, Dong-Weon;Park, Sang-Kyu
    • Journal of electromagnetic engineering and science
    • /
    • 제8권2호
    • /
    • pp.59-63
    • /
    • 2008
  • The adaptive symbol selection scheme(ASSS) is popular in reducing peak to average power ratio(PAPR) for orthogonal frequency division multiplexing(OFDM) signals. The probability density function(pdf) of the samples' amplitudes of the adaptively selected OFDM signal without over-sampling has been considered to be approximately equal to the Rayleigh pdf. In this paper, we derive a more precise pdf which shows the relationship between the probability distribution of the samples' amplitudes and the number of the candidate symbols for ASSS. Using the newly derived pdf in the theoretical analysis, more accurate calculation results can be obtained.

달리기 시 신체 충격 크기와 흡수의 성차 (Gender differences in the impact magnitude and its attenuation during running)

  • 류지선
    • 한국운동역학회지
    • /
    • 제15권1호
    • /
    • pp.91-109
    • /
    • 2005
  • The goal of this research was to determine whether gender differences exist in impact force and impact shock variables at stance phase during a preferred running. Ten male and ten female subjects volunteered to participate in this study. Impact force was quantified by using a surface-mounted force plate. In addition, Axial accelerations of the tibias and mouth were measured using low-mass accelerometers. Comparison of parameters relating to impact force and impact shock which attained from time domain, and impact shock parameters which were analyzed in frequency domain were made between genders. The conclusions based on results were as follows; 1. There were no significantly differences in impact force, mouth and tibia acceleration peak in time domain between two genders. 2. The male group was greater in impact shock peak of PSD(power spectral density) at the tibia than female group(p<.05), but no differences in active impact of PSD at the tibia and the mouth between two genders. 3. Female subjects exhibited that a peak of impact shock attenuation analyzed in frequency domain moved toward a high frequency, but no difference in time domain between two genders.