• 제목/요약/키워드: Peak performance

검색결과 2,238건 처리시간 0.022초

Seismic isolation performance sensitivity to potential deviations from design values

  • Alhan, Cenk;Hisman, Kemal
    • Smart Structures and Systems
    • /
    • 제18권2호
    • /
    • pp.293-315
    • /
    • 2016
  • Seismic isolation is often used in protecting mission-critical structures including hospitals, data centers, telecommunication buildings, etc. Such structures typically house vibration-sensitive equipment which has to provide continued service but may fail in case sustained accelerations during earthquakes exceed threshold limit values. Thus, peak floor acceleration is one of the two main parameters that control the design of such structures while the other one is peak base displacement since the overall safety of the structure depends on the safety of the isolation system. And in case peak base displacement exceeds the design base displacement during an earthquake, rupture and/or buckling of isolators as well as bumping against stops around the seismic gap may occur. Therefore, obtaining accurate peak floor accelerations and peak base displacement is vital. However, although nominal design values for isolation system and superstructure parameters are calculated in order to meet target peak design base displacement and peak floor accelerations, their actual values may potentially deviate from these nominal design values. In this study, the sensitivity of the seismic performance of structures equipped with linear and nonlinear seismic isolation systems to the aforementioned potential deviations is assessed in the context of a benchmark shear building under different earthquake records with near-fault and far-fault characteristics. The results put forth the degree of sensitivity of peak top floor acceleration and peak base displacement to superstructure parameters including mass, stiffness, and damping and isolation system parameters including stiffness, damping, yield strength, yield displacement, and post-yield to pre-yield stiffness ratio.

몇 개의 불규칙한 LDPC 부호의 Maximum Likelihood(ML) 복호에 대한 성능의 상향 한계와 정점 성능 감쇠 분석 (Upper Bounds of Maximum Likelihood (ML) Decoding Performance of a few Irregular LDPC Codes)

  • 정규혁
    • 한국통신학회논문지
    • /
    • 제34권11C호
    • /
    • pp.1025-1028
    • /
    • 2009
  • 본 논문에서는 기존의 단순 한계와 Maximum Likelihood (ML) 추정 입력 출력 무게 분포를 사용하여 몇 개의 불규칙한 LDPC 부호의 ML 복호에 대한 성능의 상향 한계를 구하고 부호의 길이가 길어지면 Belief-Propagation (BP) 복호의 성능이 ML 복호 성능에 단순하게 근접해 간다는 일반적인 견해와는 상반되게 정점 성능 감쇠(Peak Degradation)에 다다르기 이전에는 부호의 길이가 길어지면 오히려 BP 복호의 성능이 ML 복호 성능으로부터 성능 감쇠 폭이 증가하고 정점 성능 감쇠를 지난 후에 일반적인 견해가 적용되는 것을 보인다.

압축 및 내압을 받는 고무 오링의 기밀 성능 평가 (An evaluation on sealing performance of elastomeric O-ring compressed and highly pressurized)

  • 박성한;김재훈;김원훈
    • 한국정밀공학회지
    • /
    • 제26권2호
    • /
    • pp.86-93
    • /
    • 2009
  • Elastomeric O-rings have been the most common seals due to their excellent sealing capacity, and availability in costs and sizes. One of the critical applications of O-ring seals is solid rocket motor joint seal where the operating hot gas must be sealed during the combustion. This has long been a design issue to avoid the system failure. For laterally constrained, squeezed and pressurized condition, deformed shape of O-ring was measured by computed tomography method and CCD laser sensor, compared with numerical calculations. As clearance gap changes, sealing performance had been evaluated on peak contact stresses at top, bottom and side contact surfaces. As clearance gap increases, peak contact stresses and contact widths in top and side contact surfaces increase, and the asymmetry of stress distributions is promoted due to pressure increase. It is suggested that peak stress of bottom contact surface can be approximated by simple superposition of peak ones due to squeeze and pressure. Under pressurized condition, sealing performance is dependent on not peak stresses of bottom and side contact surfaces but that of top.

민감도 함수의 최대치 제어를 통한 강인제어 (Robust Control via Peak Control of Sensitivity Function)

  • 서상민
    • 제어로봇시스템학회논문지
    • /
    • 제15권11호
    • /
    • pp.1071-1075
    • /
    • 2009
  • This article describes a robust control method by using peak control of a sensitivity function in the state-feedback control systems. This method apparently reduces the peak, and as a result makes closed loop systems more stable. The designed closed loop systems also make the response to an external step disturbance more fast with a lower undershoot. At the conclusion, it is verified that the proposed method enhances robust stability and robust performance to parametric uncertainties through $\mu$-plot.

수소연료를 이용하는 원자층증착 박막전해질 세라믹연료전지의 초기성능 저하에 관한 연구 (A Study on the Initial Performance Degradation of Hydrogen-Fueled Ceramic Fuel Cell with Atomic Layer-Deposited Thin-Film Electrolyte)

  • 지상훈
    • 한국수소및신에너지학회논문집
    • /
    • 제32권5호
    • /
    • pp.410-416
    • /
    • 2021
  • The initial electrochemical performance of ceramic fuel cell with thin-film electrolyte was evaluated in terms of peak power density ratio, open circuit voltage ratio, and activation/ohmic resistance ratios at 500℃. Hydrogen and air were used as anode fuel and cathode fuel, respectively. The peak power density ratio reduced as ~17% for 40 minutes, which rapidly decreased in the early stage of the performance evaluation but gradually decreased. The open circuit voltage ratio decreased with respect time; however, its time behavior was remarkably different with the reduction behavior of the peak power density ratio. The activation resistance ratio increased as ~15% for 40 minutes, which was almost similar with the time behavior of the peak power density ratio.

Performance Evaluation of MTF Peak Detection Methods by a Statistical Analysis for Phone Camera Modules

  • Kwon, Jong-Hoon;Rhee, Hyug-Gyo;Ghim, Young-Sik;Lee, Yun-Woo
    • Journal of the Optical Society of Korea
    • /
    • 제20권1호
    • /
    • pp.150-155
    • /
    • 2016
  • To evaluate the autofocusing performance of recent mobile phone cameras, it is necessary to determine the peak position of the center field MTF (Modulation Transfer Function), -known as the through focus MTF- of the module. However, the MTF peak position found by conventional methods deviates from the ideal position due to the focus scanning resolution of mobile phone cameras. This inaccurate peak position results in false judgements of the optical performance, leading to yield losses or customer complaints. An increase in the focus scanning resolution can address this problem, but the manufacturing UPH (Unit per Hour) level will also unfortunately increase as well, resulting in a loss of manufacturing capabilities. In this paper, several fitting models are studied to find an accurate MTF peak position within a short period of time. With an analysis of a large amount of manufacturing data, it is demonstrated that the fitting methods can reduce false judgements and simultaneously increase the capabilities of the manufacturing system.

낸드 플래시 기반 저장장치의 피크 전류 모델링을 이용한 전력 최적화 기법 연구 (Power Optimization Method Using Peak Current Modeling for NAND Flash-based Storage Devices)

  • 원삼규;정의영
    • 전자공학회논문지
    • /
    • 제53권1호
    • /
    • pp.43-50
    • /
    • 2016
  • 낸드플래시 기반 저장장치는 성능 향상을 위해 다중 채널, 다중 웨이 구조를 통해 다수의 낸드 디바이스를 병렬 동작시키고 있다. 하지만 동시 동작하는 낸드 디바이스의 수가 늘어나면서 전력 소모 문제가 가시화되었으며, 특히 디바이스 간 복수의 피크 전류가 서로 중첩되면서 높은 전력소모로 인해 데이터 신뢰성과 시스템 안정성에 큰 영향을 미치고 있다. 본 논문에서는 낸드 디바이스에서 지우기, 쓰기, 읽기 동작에 대한 전류 파형을 측정, 이를 프로파일링하여 피크 전류에 대한 정의와 모델링을 진행하였고, 나아가 다수의 낸드에서 피크 전류 중첩 확률을 계산한다. 또한 시스템 수준의 TLM 시뮬레이터를 개발하여 다양한 시뮬레이션 시나리오를 주입하여 피크 전류 중첩 현상을 분석 한다. 본 실험 결과에서는 낸드간 피크 중첩 현상을 차단할 수 있는 간단한 전력 관리 기법을 적용하여 피크 전류 중첩과 시스템 성능 간의 관계를 살펴보고 이를 통해 성능 저하 최소화를 위한 피크 중첩 비율을 제시하였다.

피크위치오차 사전 보정을 통한 질량 스펙트럼 검출 성능 개선 (Improvement of Mass Spectral Detection Performance by Pre-correction of Peak Position Error)

  • 이영학;허경용;최훈
    • 한국정보통신학회논문지
    • /
    • 제23권6호
    • /
    • pp.666-674
    • /
    • 2019
  • 질량 분석기의 질량 스펙트럼에서 높은 피크값을 갖는 스펙트럼에 인접한 낮은 피크값의 스펙트럼은 서로 연결되어 분리가 어렵다. 이러한 스펙트럼간 겹칩은 질량 스펙트럼의 검출 성능과 해상도를 저하시키는 원인이 된다. 본 논문에서는 잔류 가스 분석기의 질량 스펙트럼 검출 성능과 피크값의 정확도를 향상시키는 방법을 제안한다. 이온 신호블록의 특성에 따른 유형 판별과 피크위치오차에 대한 사전 보정은 인접한 스펙트럼에 연결된 낮은 피크값의 스펙트럼 분리 및 검출할 수 있다. 제안된 방법의 성능을 확인하기 위해 질량분석기에서 얻은 실제 이온 신호를 사용하여 제안한 방법과 기존 방법을 비교하였다.

다단 맥류 스위칭을 이용한 교류-직류 변환의 성능분석 (Performance Analysis of the AC-DC Transformation Method using Multi-level Pulsating Current and Selection Switch)

  • 이재생
    • 한국군사과학기술학회지
    • /
    • 제13권4호
    • /
    • pp.586-593
    • /
    • 2010
  • In this paper, I have proposed that the 1st and 2nd AC-DC transformation methods using multi-level pulsating currents and selection switches. Through making the rectified voltage of the proposed AC-DC translation which is similar to reference voltage by selecting from multi-level pulsating currents, the proposed translation has dramatically reduced the ripple voltage. I have compared the performance of the DC voltage, the ripple voltage and the peak to peak voltage of the proposed method with the conventional method. The simulation results show that the proposed 2nd method has the better performance than the 1st method in the point of average DC voltage drop and peak to peak voltage increase.

플라즈마 원자층증착 초박막전해질 수소 세라믹연료전지의 초기성능 저하 (Initial Performance Degradation of Hydrogen-Fueled Ceramic Fuel Cell with Plasma-Enhanced Atomic Layer-Deposited Ultra-Thin Electrolyte)

  • 지상훈
    • 한국수소및신에너지학회논문집
    • /
    • 제32권5호
    • /
    • pp.340-346
    • /
    • 2021
  • The initial electrochemical performance of ceramic fuel cell with thin-film electrolyte fabricated by plasma-enhanced atomic layer deposition method was evaluated in terms of peak power density ratio, open circuit voltage ratio, and activation/ohmic resistance ratios at 500℃. Hydrogen and air were used as anode fuel and cathode fuel, respectively. The peak power density ratio reduced as ~52% for 30 min, which continually decreased as time increased but degradation rate gradually decreased. The open circuit voltage ratio decreased with respect time; however, its behavior was evidently different from the reduction behavior of the peak power density. The activation resistance ratio increased as ~127% for 30 min, which was almost similar with the reduction behavior of the peak power density ratio.